EPever Tracer5415AN, Tracer5420AN

Contents

EPEVER 50A MPPT Solar Charge Controller User Manual

Models: Tracer5415AN, Tracer5420AN

1. General Information

The Tracer-AN series MPPT solar charge controllers are designed with multiphase synchronous rectification technology (MSRT) and an advanced MPPT control algorithm. Featuring a dual-core processor and co-negative design, these controllers offer fast response, high reliability, and industrial-standard performance. MSRT ensures high conversion efficiency across all charging power levels, significantly enhancing the solar system's energy efficiency. The optimized MPPT tracking technology quickly identifies the PV array's maximum power point, maximizing energy harvest in real-time.

The automatic power reduction function ensures safe operation with excess PV modules and prevents overheating. The Tracer-AN series controllers utilize a self-adaptive three-stage charging mode, extending battery lifespan and improving system performance. They include load/utility/generator dry contacts for easy integration into hybrid power systems and comprehensive electronic protections against overcharging, over-discharging, and PV reverse polarity, ensuring reliable and durable operation.

The isolated RS485 port with standard MODBUS communication protocol and 5V power supply allows for easy application expansion, supporting up to 6 controllers in parallel. These controllers are suitable for various applications, including solar RVs, household systems, and field monitoring.

Key Features:

  • Complies with IEC62109-1 and EN61000-6-1/3 standards.
  • High-quality components for extended service life.
  • MPPT tracking efficiency of no less than 99.5%.
  • Maximum DC/DC transfer efficiency up to 98.6%; full load efficiency up to 98%.
  • Accurate multi-peak maximum power point tracking.
  • Wider MPP running voltage for increased PV module utilization.
  • Supports lead-acid and lithium batteries.
  • Program temperature compensation for batteries.
  • Real-time energy statistics function.
  • High-temperature charging automatic power reduction.
  • 100% charging and discharging within the working environment temperature range.
  • Up to 6 controllers can be connected in parallel.
  • Load dry contact to control external load switch.
  • Auto-control of utility and generator dry contact for hybrid power systems.
  • Remote temperature and voltage sensor design for accurate battery data.
  • Isolated RS485 communication ports (Modbus protocol) with 5V/200mA short circuit protection.
  • Supports remote monitoring and parameter setting via APP or PC software.

2. Important Safety Instructions

Please read and retain this manual for future reference. It contains essential safety, installation, and operation instructions for your Tracer-AN series MPPT solar controller.

  • Read all instructions and warnings carefully before installation.
  • The controller contains no user-serviceable parts; do not attempt to disassemble or repair it.
  • Mount the controller indoors, avoiding exposure to components and water ingress.
  • Install the controller in a well-ventilated area; the heat sink may become hot during operation.
  • It is recommended to install appropriate external fuses/breakers.
  • Disconnect all PV array connections and battery fuse/breakers before any installation or adjustment.
  • Ensure all power connections are tight to prevent excessive heating from loose connections.
  • Installation should be performed by professional and technical personnel.

Explanation of Symbols:

SymbolDefinition
TIPIndicates practical advice for reference.
! IMPORTANTIndicates a critical tip during operation; ignoring it may cause device error.
⚠ CAUTIONIndicates potential hazards that may damage the device if not avoided.
⚠ WARNINGIndicates danger of electric shock; if not avoided, would cause casualties.
⚠ WARNING HOT SURFACEIndicates risk of high temperature; if not avoided, would cause scalds.
ⓘRead the user manual carefully before any operation.

3. Setup (Installation)

3.1 Installation Attentions:

  • Exercise extreme caution when installing batteries. Wear eye protection and rinse with clean water immediately if battery acid contacts skin or eyes.
  • Keep batteries away from metal objects to prevent short circuits.
  • Ensure the installation environment is well-ventilated, as acid gas may be generated during battery charging.
  • Avoid direct sunlight and rain infiltration if installing outdoors.
  • Tighten all power connections and ensure cables are secure with clamps to prevent movement, which can cause overheating, wire insulation melting, or fire.
  • Only charge lead-acid and lithium-ion batteries within the controller's control range.
  • The battery connector can be wired to a single battery or a bank of batteries.
  • Select system cables with a current density of 5A/mm² or less.

3.2 Component Identification:

EPEVER MPPT Solar Charge Controller with labeled components
Figure 1: MPPT Solar Charge Controller Components
1. Charging LED indicator, 2. SELECT button, 3. Fuse, 4. Grounding Terminal, 5. Cover screw holes M4, 6. PV reverse polarity alarm indicator, 7. Generator/Load dry contact enable switch, 8. RTS Port, 9. RS485 port (5VDC/200mA), 10. Utility/Generator relay ON interface, 11. RBVS interface, 12. Load dry contact interface, 13. Utility/Generator dry contact OFF interface, 14. PV Terminals, 15. Battery Terminals, 16. ENTER button, 17. LCD, 18. Fault LED indicator.

3.3 PV Array Requirements:

The controller needs to match various PV modules to maximize solar energy conversion. The serial connection (string) of PV modules depends on the open-circuit voltage (VOC) and maximum power point voltage (VMPP) of the MPPT controller. Refer to the full PDF manual for detailed tables on PV array sizing for different controller models and system voltages.

⚠ CAUTION: The total voltage must not exceed the maximum PV open circuit voltage (e.g., 138V for Tracer**15AN at 25°C, 180V for Tracer**20AN at 25°C).

3.4 Wire Size:

The wiring and installation must comply with national and local electrical codes.

PV Wire Size:

The PV array's output current varies. The minimum wire size is calculated using the short circuit current (ISC) from the PV module's specifications. The total ISC of series-connected modules equals any single module's ISC. For parallel-connected modules, the total ISC is the sum of all modules' ISC. The PV array's ISC must not exceed the controller's maximum PV input current. Refer to the full PDF manual for detailed tables on maximum PV input current and corresponding wire sizes for different controller models.

Battery Wire Size:

The battery wire size must conform to the rated current. Refer to the full PDF manual for detailed tables on rated charging current and corresponding battery wire sizes for different controller models.

⚠ CAUTION: Wire size is for reference only. For long distances between the PV array and controller, or controller and battery, use larger wires to reduce voltage drop and improve system performance. The recommended wire for the battery should not be connected to any additional inverter.

3.5 Dry Contact Instruction:

The dry contacts have a rated value of 5A/30VDC and a maximum value of 0.5A/60VDC.

Control Utility/Generator ON/OFF:

The Utility/Generator dry contact controls external devices. Set the switch to the ON position to enable. The start-up voltage (VON) and stop voltage (VOFF) can be configured via PC software. The utility/generator starts when battery voltage (VBAT) is less than VON and stops when VBAT is greater than VOFF.

⚠ CAUTION: If the temperature sensor is short-circuited or damaged, the controller will charge/discharge at a default 25°C (no temperature compensation).

Control Load Disconnection:

The controller manages load disconnection based on battery voltage thresholds (Under Voltage Warning Voltage (VUVW), Under Voltage Warning Recover Voltage (VUVWR), Low Voltage Disconnect Voltage (VLVD), Low Voltage Reconnect Voltage (VLVR)). The Utility/Generator dry contact OFF interface controls the first disconnection, and the Load dry contact controls the second disconnection.

3.6 Mounting:

⚠ WARNING: Risk of explosion! Never install the controller in a sealed enclosure with flooded batteries or in a confined area where battery gas can accumulate.

⚠ WARNING: Risk of electric shock! Disconnect the breaker before wiring solar modules, as the PV array can produce high open-circuit voltage. Tracer-AN series controllers have no battery reverse protection; do not reverse battery wiring, or the controller may be damaged.

⚠ CAUTION: The controller requires at least 150mm clearance above and below for proper airflow. Ventilation is highly recommended if mounted in an enclosure.

Installation Procedures:

  1. Determine Installation Location and Heat-Dissipation Space: Ensure sufficient airflow around the controller's heat sink. Maintain at least 150mm clearance from upper and lower edges.
  2. Remove Terminal Protective Cover: Carefully remove the protective cover before wiring.
  3. Connect the Battery (Left) and PV (Right):
    • Disconnect the system in reverse order.
    • Do not connect the circuit breaker or fuse during wiring. Ensure correct electrode polarity.
    • Install a fuse (1.25 to 2 times the controller's rated current) on the battery side, no more than 150mm from the battery.
    • Connect the inverter directly to the battery, not the controller's load side.
    • If using a lithium battery and inverter, connect the controller's (Load) dry contact to the inverter's start-stop dry contact to prevent damage from overcurrent.
  4. Grounding: Tracer-AN series controllers are common-negative. Negative terminals of the PV array and battery can be grounded simultaneously, or any terminal can be grounded. The grounding terminal on the shell must be grounded to shield electromagnetic interference and prevent electric shock.
  5. Connect Accessories:
    • Remote Temperature Sensor Cable (RTS300R47K3.81A): Connect to the RTS interface and place the other end near the battery (sampling distance no longer than 20m). If not connected, the controller charges/discharges at a default 25°C.
    • Remote Battery Voltage Sensor Cable (RVBS300B3.81): Connect to the RBVS interface and the other end to the battery terminals for accurate voltage detection (sampling distance no longer than 20m).
    • RS485 Communication: Refer to the accessories list for connecting RS485 communication accessories.
  6. Power on the Controller: Connect the battery fuse to power the controller. Once the LCD displays normally, connect the PV array's circuit breaker. The charging indicator will flash slowly during PV charging.

⚠ CAUTION: If the controller does not work properly or the fault indicator shows an abnormality, refer to the Troubleshooting section.

3.7 Wiring Diagrams:

Single Controller Wiring Diagram
Figure 2: Single Controller Wiring Diagram
This diagram illustrates the connection of a single MPPT solar charge controller to a solar panel, battery, inverter, and various household loads. It shows connections for utility/generator relay, AC/DC charger, and load relay.
Parallel Connection and Protections Diagram
Figure 3: Parallel Connection and Extensive Protections
This diagram shows how multiple controllers (up to 6 units) can be connected in parallel using an RS485 communication port and parallel adapter. It also highlights the extensive protections offered by the system, including Low Voltage, Over Temperature, Over Discharge Protection, Over Voltage, Overcurrent Protection, and PV current/power-limiting.
House Wiring Diagram
Figure 4: Typical House Wiring Diagram with Solar Controller
This diagram illustrates a complete solar power system integration within a household, showing the flow of direct current (DC) from solar panels to the controller and battery, and then converted to alternating current (AC) for household appliances via an inverter.

4. Operation

4.1 Indicators:

IndicatorColorStatusInstruction
Charging LEDGreenON solidPV charges the battery with a low current.
GreenOFF1. No sunlight
2. Connection error
3. Low PV voltage
GreenSlowly flashing (1Hz)Normal charging
GreenFast flashing (4Hz)PV over voltage

IMPORTANT: The fault indicator refers to the LCD Display section.

4.2 Buttons:

ModesNote
(Load) dry contactIn manual mode, short-press the "ENTER" button to turn on/off the (Load) dry contact.
Clear faultPress the "ENTER" button.
Browsing modeShort-press the "SELECT" button.
Setting modeLong-press the "ENTER" button to enter Setting mode. Short-press "SELECT" to modify parameters. Short-press "ENTER" to confirm or exit automatically after 10s.

4.3 LCD Display:

The LCD provides real-time status information. The display screen is best viewed when the angle between the user's horizontal sight and the screen is within 90°.

Status Description:

NameSymbolStatus
PV array☀️Day
🌙Night
No charge
Charging
PVPV array's voltage, current, and generated energy
BatteryBattery capacity, In Charging
BATT.Battery Voltage, Current, Temperature
BATT. TYPEBattery type
Load💡(Load) dry contact connected
W(Load) dry contact disconnected

Browse Interface:

When there is no operation, the display interface will automatically cycle through various screens, except for load time 1 and load time 2 interfaces.

4.4 Settings:

  1. Clear Generated Energy: In the PV power interface, long-press the "ENTER" button until the value flashes. Press "ENTER" again to confirm and reset.
  2. Switch Battery Temperature Unit: In the battery temperature interface, long-press the "ENTER" button to switch the unit.
  3. Battery Type:
    • Supported Battery Types: Lead-acid (Sealed, Gel, Flooded, User-defined) and Lithium (LiFePO4, Li(NiCoMn)O2, User-defined).
    • Set via LCD: On the battery voltage interface, long-press "ENTER" until the battery type flashes. Use "SELECT" to change the type and "ENTER" to confirm. Note: Only lead-acid battery types can be set via LCD; lithium battery types must be set via PC or APP software.
    • Set via PC Software or APP Software: Connect the controller to a PC via USB-RS485 converter or to a mobile phone via WIFI/Bluetooth module. Refer to the cloud platform manual for specific settings.
  4. Battery Voltage Control Parameters: Detailed parameters for lead-acid and lithium batteries (Over voltage disconnect, Charging limit, Boost, Float, Low voltage reconnect, etc.) are available in the full PDF manual. These parameters are measured at 12V/25°C; double values for 24V systems and quadruple for 48V systems.

5. Maintenance

The following inspections and maintenance tasks are recommended at least twice yearly for optimal performance:

  • Ensure no obstructions block airflow around the controller. Clean any dirt or fragments from the radiator.
  • Check all exposed wires for insulation damage (sun exposure, friction, wear, dryness, insects, rats, etc.). Repair or replace damaged wires as necessary.
  • Verify that the LED indicators are consistent with expected behavior. Address any troubleshooting or error indications promptly.
  • Confirm that all terminals are free of corrosion, insulation damage, high temperature, or burnt/discolored signs. Tighten terminal screws to the suggested torque.
  • Clean any dirt, nesting insects, or corrosion in time.
  • Check and confirm that the lightning arrester is in good condition. Replace it if necessary to prevent damage to the controller and other equipment.

⚠ WARNING: Risk of electric shock! Ensure all power is turned off before performing any maintenance operations.

6. Troubleshooting

6.1 Error Codes and Indicators:

StatusFaults IndicatorCharging IndicatorSymbolInstruction
Battery over dischargedRed ON solid--Battery level empty, battery frame blink, fault icon blink.
Battery over voltageRed Slow flashing--Battery level full, battery frame blink, fault icon blink.
Battery over heatingRed slowly flashing--Battery level shows current value, battery frame blink, and fault icon blink.
Controller over temperatureRed slowly flashingGreen slowly flashingBattery level shows current value, battery frame blink, and fault icon blink.
System voltage errorRed slowly flashingFast flashing in greenBattery level shows current value, battery frame blink, and fault icon blink.

6.2 Common Faults and Solutions:

FaultsSolutions
Charging LED is OFF during daytime when sunshine falls on PV array properly.Confirm whether the connection of the PV array is correct and tight.
The wire connection is correct; the controller is not working.The battery voltage is lower than 8V. Check the battery's voltage (at least 8V to activate the controller).
Battery frame blink, fault icon blink (Battery over voltage).Check whether the battery voltage is higher than OVD (over voltage disconnect voltage) and disconnect the PV array connection.
Battery frame blink, fault icon blink (Battery over discharged).1. When the battery voltage is restored to or above LVR (low voltage reconnect voltage), the load recovers.
2. Use other ways to recharge the battery.
Battery frame blink, fault icon blink (Battery over heating).While the battery temperature declines to 55°C or below, the controller resumes work.

6.3 Protections:

  • PV Current/Power-Limiting Protection: When the PV array's actual charging current or power exceeds the controller's rated limits, the controller charges the battery at the rated current or power.
  • PV Short-Circuit Protection: The controller will not be damaged if the PV array short-circuits when not in charging state. WARNING: Do not short-circuit the PV array during charging, as it may damage the controller.
  • PV Reverse Polarity Protection: The controller will not be damaged if the PV array's polarity is reversed and will resume work after correction. CAUTION: If the PV array is reversed and its actual power is 1.5 times the rated power, the controller may be damaged.
  • Night Reverse Charging Protection: Prevents the battery from discharging to the PV module at night.
  • Battery Over Voltage Protection: The PV array automatically stops charging when battery voltage reaches the over voltage disconnect voltage.
  • Battery Over Discharging Protection: Battery discharging automatically stops when battery voltage reaches the low voltage disconnect voltage. CAUTION: This protection takes effect when the battery connects with a load via the controller's (Load) dry contact.
  • Battery Over Heating Protection: The controller detects battery temperature via an external sensor. Charging stops if temperature exceeds 65°C and resumes below 55°C.
  • Lithium Battery Low Temperature Protection: Charging/discharging stops if temperature is below the Low Temperature Protection Threshold (LTPT) and resumes when above. LTPT is 0°C by default (adjustable -10°C to -40°C).
  • Controller Overheating Protection: An internal sensor detects controller temperature. Operation stops if temperature exceeds 85°C and resumes below 75°C. Charging power is reduced if internal temperature is 81°C or higher.
  • TVS High Voltage Transients Protection: Internal circuitry provides protection against high-voltage surge pulses with less energy. For areas with frequent lightning strikes, an external surge arrester is recommended.

7. Specifications

The Tracer-AN series MPPT solar charge controllers are available in various models, including Tracer5415AN and Tracer5420AN. Below are the general specifications for these models. For detailed specifications of other models (Tracer6210AN, Tracer6415AN/6420AN, Tracer8415AN/8420AN, Tracer10415AN/10420AN), please refer to the full PDF user manual.

ParameterTracer5415ANTracer5420AN
Nominal System Voltage12/24/36/48VDC Auto
Controller Working Voltage Range8V ~ 68V
Battery TypeLead-acid (Sealed/Gel/Flooded/User), Lithium (LiFePO4/Li(NiCoMn)O2/User)
Rated Charging Current50A
Rated Charging Power625W/12V, 1250W/24V, 1875W/36V, 2500W/48V625W/12V, 1250W/24V, 1875W/36V, 2500W/48V
Max. PV Open-Circuit Voltage150V (lowest temp), 138V (25°C)200V (lowest temp), 180V (25°C)
MPPT Voltage Range(Battery voltage +2V) ~ 108V (25°C)(Battery voltage +2V) ~ 144V (25°C)
MPPT Tracking Efficiency≥99.5%
Max. Conversion Efficiency98.3%
Full Load Efficiency97.8%97.1%
Self-Consumption98mA/12V, 60mA/24V, 50mA/36V, 46mA/48V
GroundingCommon Negative Grounding
Communication MethodRS485 (5VDC/200mA, Two RJ45 ports in parallel)
Dimensions (L x W x H)261 x 216 x 119 mm
Net Weight3.5 kg
EnclosureIP20
Operating Temperature Range-25°C ~ +60°C (derating above 45°C)
CertificationCE, FCC, RoHS

8. User Tips

  • Charging Current Limiting: The controller automatically manages charging current based on PV input and battery state. While direct user-set current limiting (e.g., to 20A) is not explicitly mentioned as a standard feature for all battery types via the LCD, advanced settings via PC software or APP might offer more granular control for specific battery types (especially user-defined lithium profiles). Consult the full PDF manual or EPEVER support for detailed information on advanced current limiting capabilities.
  • Battery Type Configuration: Always ensure the correct battery type (Sealed, Gel, Flooded, LiFePO4, Li(NiCoMn)O2) is selected in the controller settings. Incorrect settings can lead to improper charging and reduced battery lifespan. For lithium batteries, use the PC or APP software for precise configuration.
  • Temperature Compensation: Utilize the remote temperature sensor for accurate battery temperature compensation, especially in environments with significant temperature fluctuations. This optimizes charging and prolongs battery life.

9. Warranty and Support

For detailed warranty information, technical support, and service inquiries, please refer to the official EPEVER website or contact your authorized dealer. The comprehensive user manual in PDF format provides additional in-depth information on installation, operation, and advanced settings.

Download Full User Manual (PDF): Click here to view the PDF manual

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.