Introduction
This manual provides detailed instructions for the proper assembly, operation, and maintenance of your Svbony SM201 Binocular Compound Microscope. Please read this manual thoroughly before using the microscope to ensure optimal performance and longevity.

Figure 1: Svbony SM201 Binocular Compound Microscope
Package Contents
Verify that all items listed below are included in your package:

Figure 2: Package Contents
- 1x SM201 Microscope
- 1x Pair of WF10X Eyepieces
- 1x Pair of WF25X Eyepieces
- 1x Cell Phone Adapter
- 4x Dust Covers
- 1x User Manual (this document)
- 1x Microscope Slides Set and Cleaning Kit
- Objective Lenses: 4X, 10X, 40X, 100X (Oil Immersion)
Setup
- Unpacking: Carefully remove all components from the packaging.
- Power Supply:
- Battery Power: Open the battery compartment at the base of the microscope and insert 3 AA batteries (not included).
- AC Power: Connect the 5V1A power adapter (included) to the power interface on the side of the microscope and plug it into a suitable power outlet.

Figure 3: Battery and 5V1A Power Interface
- Eyepiece Installation: Insert your desired pair of wide-field eyepieces (WF10X or WF25X) into the binocular head.

Figure 4: Inserting Eyepieces
- Objective Lens Selection: Rotate the revolving nosepiece to select the lowest power objective lens (e.g., 4X) for initial observation.

Figure 5: Objective Lenses
- Phone Adapter Attachment (Optional): If using the phone adapter, attach it to one of the eyepieces as shown in the diagram. Secure your smartphone in the adapter.

Figure 6: Phone Adapter Attachment
Operating Instructions
- Power On and Illumination:
- Flip the power switch located at the base of the microscope.
- Adjust the LED light intensity using the dimmer control to achieve comfortable illumination.

Figure 7: LED Light Adjustment
- Placing the Specimen:
- Place a prepared specimen slide onto the mechanical stage.
- Use the stage control knobs to center the specimen under the objective lens.

Figure 8: Moving the Mechanical Stage
- Focusing:
- Using the coarse focus knob, slowly raise the stage until the specimen comes into rough focus.
- Then, use the fine focus knob for precise focusing until the image is sharp and clear.

Figure 9: Dual Focusing Knobs
- Adjusting Abbe Condenser: Adjust the NA1.25 Abbe condenser to optimize contrast and resolution for your specimen.
Video 1: Adjusting the Abbe Condenser (0:28-0:34 in product video)
- Changing Magnification: Rotate the revolving nosepiece to switch between objective lenses (4X, 10X, 40X, 100X). Re-focus with the fine adjustment knob as needed.
Video 2: Switching Objective Lenses (1:20-1:27 in product video)
Note on 100X Oil Immersion Objective:
- When using the 100X objective, a drop of cedar oil must be placed directly on the specimen slide.
- Lower the objective until it makes contact with the oil, then focus carefully. This technique greatly enhances clarity for very fine structures.

Figure 10: 100x Oil Immersion Objective Lens
- Binocular Head Adjustments:
- Interpupillary Distance: Adjust the distance between the eyepieces to match your eye spacing for comfortable viewing.
- Diopter Adjustment: The right eyepiece has a diopter adjustment ring. While looking through the left eyepiece with your left eye (right eye closed), focus the image using the coarse and fine focus knobs. Then, look through the right eyepiece with your right eye (left eye closed) and adjust only the diopter ring until the image is sharp.
Video 3: Diopter Adjustment (1:47-1:52 in product video)
- Rotation: The binocular head can be rotated 360 degrees for shared viewing or comfortable positioning.
Video 4: 360-degree Rotatable Eyepiece (1:35-1:45 in product video)
- Using Phone Adapter: Once attached, open your smartphone's camera app and align it with the eyepiece to view and capture images or videos of your specimen.
Video 5: How to use the Phone Holder (1:01-1:18 in product video)
- Electronic Eyepiece (Optional): The microscope can be used with an SV189 electronic eyepiece (sold separately) to connect to a computer for digital viewing and analysis.
Video 6: Using with SV189 Electronic Eyepiece (1:53-1:56 in product video)
Maintenance
- Cleaning Lenses: Use only specialized lens cleaning paper and solution. Gently wipe objective lenses and eyepieces. Never use abrasive materials.
- Cleaning Oil Immersion Lens: After using the 100X oil immersion objective, immediately clean off all cedar oil using lens paper and a small amount of lens cleaning solution. Failure to do so can damage the lens.
- General Cleaning: Wipe the microscope body with a soft, damp cloth. Avoid using harsh chemicals or solvents.
- Dust Protection: Always use the provided dust covers when the microscope is not in use to prevent dust accumulation on optical components.
- Storage: Store the microscope in a cool, dry place, away from direct sunlight and extreme temperatures.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No illumination | Power switch off, batteries depleted, AC adapter unplugged, LED dimmer set to minimum. | Turn on power switch, replace batteries, check AC adapter connection, increase LED brightness. |
| Image blurry/cannot focus | Incorrect focusing, objective lens not fully clicked into place, specimen upside down, dirty lens. | Use coarse and fine focus knobs, rotate nosepiece until objective clicks, ensure specimen is correctly oriented, clean lenses. |
| Dark field of view | Diaphragm closed too much, condenser too low, light intensity too low. | Open diaphragm, raise condenser, increase LED brightness. |
| Only one eye sees image (binocular) | Interpupillary distance incorrect, diopter not adjusted. | Adjust interpupillary distance, perform diopter adjustment. |
Specifications
| Feature | Detail |
|---|---|
| Model Number | SM201 |
| Theory | Biological Microscope |
| Drawtube | BINOCULAR |
| Eyepieces | WF10X, WF25X Wide Field |
| Objective Lenses | 4X, 10X, 40X, 100X (Oil Immersion) Achromatic |
| Magnification Range | 40X - 2500X (Maximum 2500x) |
| Condenser | NA1.25 Abbe Condenser with Iris Diaphragm |
| Illumination | LED Light, Adjustable Brightness |
| Stage | Double-layer Mechanical Stage |
| Focusing | Coaxial Coarse and Fine Focus Knobs |
| Head Tilt | 30 Degrees |
| Head Rotation | 360 Degrees |
| Material | Metal Body |
| Power Source | 5V1A or Battery-Powered (3 AA) |
| Item Weight | 2600g |
| Package Size | 540 x 390 x 400 mm |

Figure 12: Key Features Overview
User Tips
- Always start observation with the lowest magnification objective (4X) to locate and center your specimen. Then, gradually increase magnification.
- When switching to higher power objectives, especially 40X and 100X, be very careful not to crash the objective into the slide. Use the fine focus knob for small adjustments.
- For optimal viewing with the 100X oil immersion lens, ensure there are no air bubbles in the immersion oil.
- Experiment with the condenser and diaphragm settings to achieve the best contrast and resolution for different types of specimens.
Warranty and Support
For detailed warranty information, please refer to the documentation provided with your purchase or visit the official Svbony website. A digital version of this manual may also be available online:
View Official SM201 Manual PDF
For further assistance or technical support, please contact Svbony customer service through their official channels.