1. Overview
The EPever 51.2V 100Ah Lithium Battery is a high-performance energy storage solution designed for various applications, including solar systems. Built with premium prismatic LiFePO4 cells, this battery offers enduring reliability and a long cycle life. It features intelligent cell balancing and a robust safeguard suite to ensure safe and efficient operation.
Key Features:
- A-grade brand new prismatic LiFePO4 cells for superior performance and longevity.
- Exceptional cycle life of ≥5000 cycles at 80% Depth of Discharge (DOD) under 25°C and 0.5C.
- Integrated cell balance function for optimized battery health and performance.
- Supports RS485, CAN, and RS232 communication protocols for versatile system integration.
- Comprehensive protection against overcharge, over-discharge, over-temperature, low-temperature, overcurrent, and short circuits.
- Scalable design allowing up to 8 battery packs to be connected in parallel for increased capacity.
Versatile Applications:
This battery is suitable for a wide range of uses, including:
- Electric vehicles
- Golf carts
- Lighting systems
- Electric tools
- Electric cleaning vehicles
- PV (Photovoltaic) storage systems
- Electric toy vehicles

2. Safety Instructions
WARNING: Failure to follow these safety instructions may result in fire, electric shock, serious injury, or property damage.
- Do not charge the battery in a sealed container. Ensure adequate ventilation during charging.
- Do not short circuit the battery terminals. This can cause severe damage to the battery and pose a fire hazard.
- Do not incinerate, crush, puncture, or disassemble the battery.
- Do not discard the battery in fire or expose it to excess heat.
- Do not overcharge or over-discharge the battery beyond its specified voltage limits.
- Only use an approved battery charger that is compatible with LiFePO4 batteries and the specified voltage.
- Keep the battery away from children and pets.
- In case of fire, use a Class D fire extinguisher (for metal fires) or a CO2 extinguisher. Do not use water.
- If the battery is damaged or leaking, avoid contact with the electrolyte. Wear protective gloves and eye protection.


3. Product Components
The EPever LiFePO4 battery is engineered with high-quality components for optimal performance and safety.
Internal Components:
- LFP Battery Cells: A-grade brand new prismatic LiFePO4 cells provide the core energy storage.
- BMS (Battery Management System): An advanced BMS monitors and manages battery parameters, ensuring safety and extending lifespan through features like cell balancing and protection against various faults.
- Metal Case: A durable metal enclosure protects the internal components from physical damage and environmental factors.
External Features:
- BATT+ and BATT- Terminals: Robust M6 terminals for secure power connections.
- ON/OFF Switch: Main power control for the battery.
- LED Indicators: Provide visual feedback on battery status, charge level, and fault conditions.
- Communication Ports (RS485, CAN, RS232): Allow for external monitoring, control, and integration with other system components.


4. Setup and Installation
Proper setup is crucial for the safe and efficient operation of your EPever LiFePO4 battery. Always ensure all connections are secure and correctly polarized.
Initial Inspection:
- Unpack the battery and inspect it for any visible damage.
- Verify that all accessories are present.
Connecting the Battery:
- Placement: Place the battery in a well-ventilated area, away from direct sunlight, heat sources, and flammable materials. Ensure the ambient temperature is within the recommended operating range.
- Single Battery Connection:
- Connect the positive (+) terminal of the battery to the positive (+) input of your charge controller/inverter using appropriate gauge cables.
- Connect the negative (-) terminal of the battery to the negative (-) input of your charge controller/inverter.
- Ensure all connections are tight and secure. The terminals are M6 type.
- Parallel Connection (for increased capacity):
- Up to 8 battery packs can be connected in parallel.
- Ensure all batteries are of the same model and have similar states of charge before connecting them in parallel.
- Connect the positive (+) terminals of all batteries together.
- Connect the negative (-) terminals of all batteries together.
- Then, connect the combined positive and negative terminals to your charge controller/inverter.
- Use appropriate busbars and cables for parallel connections to handle the increased current.
- Communication Connections: If integrating with a compatible charge controller or inverter, connect the RS485, CAN, or RS232 communication cables as per your system's requirements and the respective device manuals.

Initial Charging:
It is recommended to fully charge the battery before its first use. Use a compatible LiFePO4 charger set to the correct voltage and current parameters (refer to the Specifications section for Charge Cut-off Voltage and Max. Charge Current).
5. Operating Instructions
Follow these guidelines for optimal performance and longevity of your EPever LiFePO4 battery.
Turning On/Off:
- To Turn On: Press the ON/OFF switch. The LED indicators will illuminate, showing the battery status.
- To Turn Off: Press the ON/OFF switch again. The LED indicators will turn off.
Charging:
- Connect a compatible LiFePO4 charger to the battery terminals.
- Ensure the charger's output voltage does not exceed the battery's Charge Cut-off Voltage (57.6V).
- The maximum recommended charge current is 50A. Exceeding this can damage the battery.
- Monitor the LED indicators for charging status.
Discharging:
- The battery can provide a continuous discharge current of up to 50A.
- The maximum discharge current is 100A, with a peak discharge current of 130A for 10 seconds.
- Avoid discharging the battery below its Discharge Cut-off Voltage (41.6V) to prevent damage and prolong lifespan.
- The recommended discharge depth (DOD) is 80% for optimal cycle life.
Monitoring:
The built-in LED display provides basic status information. For detailed monitoring and control, utilize the RS485, CAN, or RS232 communication interfaces with compatible external devices.
6. Maintenance
Regular maintenance helps ensure the long-term performance and safety of your battery.
- Cleaning: Keep the battery clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use solvents or abrasive cleaners.
- Terminal Inspection: Periodically check the battery terminals and cable connections for tightness and corrosion. Clean any corrosion with a wire brush and apply a thin layer of dielectric grease if necessary.
- Environmental Conditions: Ensure the battery operates and is stored within the recommended temperature and humidity ranges.
- Charge & Discharge Temperature: Charge: 0°C~+55°C | Discharge: -20°C~+60°C
- Optimal Storage Temperature: 5°C ~ +35°C
- Recommend Storage Humidity: 20%~80%
- Long-Term Storage: If storing the battery for an extended period, ensure it is charged to approximately 50-70% of its capacity and stored in a cool, dry place. Periodically check the charge level and recharge if necessary.
7. Troubleshooting
This section addresses common issues you might encounter with your EPever LiFePO4 battery. The battery's integrated BMS provides multiple protections, which may cause the battery to shut down or not operate if certain conditions are met.
Common Issues & Solutions:
- Battery Not Turning On:
- Ensure the ON/OFF switch is in the 'ON' position.
- Check all cable connections for tightness and correct polarity.
- Verify that the battery has sufficient charge. If deeply discharged, it might require a specific charging sequence from a compatible charger.
- Battery Not Charging:
- Confirm the charger is compatible with LiFePO4 batteries and is functioning correctly.
- Check the charger's output voltage and current settings against the battery's specifications.
- Ensure the charging temperature is within the acceptable range (0°C~+55°C). The BMS may prevent charging outside this range.
- Inspect charging cables for damage.
- Battery Not Discharging / Sudden Shutdown:
- The BMS may have activated a protection feature (e.g., over-discharge, overcurrent, over-temperature, low-temperature, short-circuit).
- Check the battery's state of charge. If it's too low, the BMS will prevent further discharge.
- Reduce the load if an overcurrent protection was triggered.
- Ensure the operating temperature is within the acceptable range (-20°C~+60°C).
- If a short circuit occurred, disconnect the load immediately and inspect for faults before reconnecting.
- Communication Issues:
- Verify communication cable connections are secure and correctly wired.
- Ensure the external device (e.g., inverter, charge controller) is configured for the correct communication protocol (RS485, CAN, or RS232).
- Consult the manuals for both the battery and the external device for specific communication setup procedures.
If the issue persists after attempting these troubleshooting steps, please contact EPever customer support or your local dealer for assistance.
8. Technical Specifications
| Parameter | Value |
|---|---|
| Model | LFP5.12KWH51.2V-P20R1 |
| Battery Type | LiFePO4 |
| Nominal Voltage (V) | 51.2 |
| Nominal Capacity (AH) | 100 |
| Energy (WH) | 5120 |
| Pack Mode | 16S1P |
| Continuous Discharge Current (A) | 50 |
| Charge Cut-off Voltage (V) | 57.6 |
| Discharge Cut-off Voltage (V) | 41.6 |
| Max. Charge Current (A) | 50 |
| Max. Discharge Current (A) | 100 |
| Peak Discharge Current (A) | 130@10S |
| Recommend Discharge Current (A) | 50 |
| Recommend Discharge Depth (%) | 80 |
| Cycle Life | ≥5000 cycles (25°C, 0.5C) 80% DOD |
| Communication | RS485 CAN RS232 |
| Display | LED |
| Charge & Discharge Temperature (°C) | Charge: 0°C~+55°C | Discharge: -20°C~+60°C |
| Optimal Storage Temperature (°C) | 5°C ~ +35°C |
| Recommend Storage Humidity | 20%~80% |
| Terminal | M6 |
| Dimensions (W*H*D) (mm) | 502*482*176 |
| Weight (Kg) | 49±1 |
| Transportation | UN38.3 MSDS |
| IP Class | IP20 |
9. User Tips
- Charging Voltage: When setting up your charge controller or inverter, ensure the floating voltage and bulk charge voltage are configured correctly for LiFePO4 batteries. The battery's Charge Cut-off Voltage is 57.6V, which is a critical parameter for your charging source. Always refer to your charger's manual for specific settings for 51.2V LiFePO4 batteries.
- Parallel Connection Best Practice: When connecting multiple batteries in parallel, ensure all batteries are at a similar state of charge before making the final connections. This prevents large current surges between batteries.
- Cable Sizing: Use appropriately sized cables for all connections to prevent overheating and ensure efficient power transfer, especially when operating at maximum discharge currents or with multiple batteries in parallel.
10. Warranty and Support
For warranty information, technical support, or service inquiries regarding your EPever LiFePO4 battery, please contact the manufacturer, EPever, or your authorized dealer. Keep your purchase receipt and product model number (LFP5.12KWH51.2V-P20R1) readily available when seeking support.