1. Product Overview
The EPEVER IPower series is a pure sine wave inverter designed to convert DC power (12V/24V) into stable AC power (110V/120V or 220V/230V). Its industrial design ensures a wider operating temperature range, easy installation, and user-friendly operation, making it suitable for various applications such as household emergency lighting systems, vehicle-mounted systems, and small field power supplies. The wide input voltage range is ideal for solar system applications.
Key Features:
- Safe design with input and output electrical isolation.
- Adoption of advanced SPWM technology for pure sine wave output.
- Optional output voltage (220/230VAC or 110/120VAC), configurable via DIP switches.
- Output frequency (50/60Hz), configurable via DIP switches.
- LED indicators for clear working and fault status display.
- Lower no-load consumption for improved efficiency.
- Maximum efficiency up to 95%.
- Comprehensive input protection: Over voltage protection, low voltage protection.
- Robust output protection: Overload protection, short circuit protection.
- Advanced over-temperature protection: Temperature-controlled fan ventilation; inverter automatically turns off when over temperature is detected.
- Operational USB output: 5VDC/1A for charging devices.
Product Contents:
Unboxing Video:
2. Setup and Installation
Component Identification:
| No. | Component | No. | Component |
|---|---|---|---|
| ① | DC Input Terminal Positive | ⑥ | Mode switch |
| ② | DC Input Terminal Negative | ⑦ | Fault indicator (red) |
| ③ | DC input voltage range* | ⑧ | Working indicator (green) |
| ④ | Ventilation Fan* | ⑨ | USB output port (5VDC/1A) |
| ⑤ | AC output switch | ⑩ | AC Outlet* |
DC Input Connection:
Ensure proper polarity when connecting the inverter to your battery system. Incorrect connections can damage the unit.
- For a 12V system, the input voltage range is 10.8V to 16V.
- For a 24V system, the input voltage range is 21.6V to 32V.
- Always connect the positive (+) terminal to the positive battery terminal and the negative (-) terminal to the negative battery terminal.
- Ensure appropriate fuses are installed in the DC input line for safety.
AC Output Connection:
Connect your AC loads to the inverter's AC outlet. The inverter also provides a USB output for charging compatible devices.
AC Outlet Types:
The IPower series inverters may come with different AC outlet types depending on the model and region:
Output Voltage and Frequency Setting (DIP Switches):
The output voltage and frequency can be configured using the DIP switches located on the inverter. Refer to the diagrams below for specific settings:
- When switch No.1 is in the ON position, the output frequency is 60Hz. Otherwise, it is 50Hz.
- When switch No.2 is in the ON position, the output voltage is 230VAC (or 120VAC). Otherwise, it is 220VAC (or 110VAC).
NOTE: Turn off the inverter to reset the output frequency or output voltage. Then, restart the inverter when the setting is complete.
WARNING: DO NOT turn ON/OFF the mode switch when the inverter is working.
3. Operating Instructions
Powering On/Off:
- Ensure all DC input connections are secure and correct.
- Verify that the DIP switches are set to your desired output voltage and frequency.
- Turn on the AC output switch (⑤ in the component identification diagram) to power on the inverter.
- To power off, turn off the AC output switch.
LED Indicators and Buzzer:
The inverter provides visual (LEDs) and audible (buzzer) feedback to indicate its operational status and any detected faults. Refer to the table below for interpretation:
| Working indicator | Fault indicator | Buzzer | Status |
|---|---|---|---|
| Green On Solid | Red OFF | No Sounding | Output is normal |
| Green Slowly Flashing (1/4Hz) | Red OFF | Sounding | Input under-voltage |
| Green Fast Flashing (1Hz) | Red OFF | Sounding | Input overvoltage |
| Green On Solid | Red ON Solid | Sounding | Over-temperature |
| Green OFF | Red Fast Flashing (1Hz) | Sounding | Load short circuit |
| Green On Solid | Red Slowly Flashing (1/4Hz) | Sounding | Overload |
| Green OFF | Red OFF | Sounding | Output voltage abnormal |
USB Output Port:
The inverter includes a USB output port (5VDC/1A) for convenient charging of small electronic devices such as smartphones and tablets.
4. Maintenance
Fan Ventilation:
- The internal cooling fan operates automatically based on temperature.
- The fan will turn on when the heat sink temperature or internal temperature exceeds 50℃.
- The fan will turn off when both the heat sink temperature and internal temperature drop below 40℃.
- Ensure the ventilation fan (④ in the component identification diagram) is not obstructed to allow for proper airflow and cooling.
General Maintenance:
- Regularly inspect all wiring connections to ensure they are tight and free from corrosion.
- Keep the inverter clean and free from dust and debris. Use a dry cloth for cleaning.
- Ensure the inverter is installed in a well-ventilated area, away from direct sunlight, heat sources, and moisture.
5. Troubleshooting
If the inverter is not functioning as expected, refer to the LED Indicator and Buzzer Status Table in Section 3 to diagnose the issue. Common problems and their solutions are listed below:
- No Output / Inverter Not Turning On:
- Check DC input connections for proper polarity and secure contact.
- Verify battery voltage is within the specified input range (10.8-16V for 12V systems, 21.6-32V for 24V systems).
- Check for blown fuses in the DC input line.
- Ensure the AC output switch is in the 'ON' position.
- Fault Indicator (Red LED) On / Buzzer Sounding:
- Input Under-voltage/Overvoltage: Check battery voltage. Recharge or replace batteries if necessary.
- Over-temperature: Ensure adequate ventilation. Clear any obstructions from the fan. Allow the inverter to cool down.
- Load Short Circuit: Disconnect all AC loads and check for short circuits in the connected appliances or wiring.
- Overload: Reduce the total power consumption of connected AC loads. The inverter's continuous power is 400W, with a 15-minute power of 500W and surge power of 1000W. Do not exceed these limits.
- Output Voltage Abnormal: This may indicate an internal fault. Contact customer support if the issue persists after checking other conditions.
- No USB Output:
- Ensure the inverter is powered on.
- Check the USB cable and the device being charged.
If the problem persists after attempting these troubleshooting steps, please contact EPEVER customer support.
6. Technical Specifications
| Item | IP500-12 | IP500-22 | IP500-11 | IP500-21 |
|---|---|---|---|---|
| Rated Input Voltage | 12VDC | 24VDC | 12VDC | 24VDC |
| Input Voltage Range | 10.8~16VDC | 21.6~32VDC | 10.8~16VDC | 21.6~32VDC |
| Input Surge Voltage | <32VDC | <44VDC | <32VDC | <44VDC |
| Output Voltage | 220VAC(±5%) 230VAC(-10%~+5%) |
110VAC(±5%) 120VAC(-10%~+5%) |
||
| Output Frequency | 50/60±0.1Hz | |||
| Output Continuous Power | 400W | |||
| Output Power 15min. | 500W | |||
| Surge power | 1000W | |||
| Power factor | 0.2-1 (VA lower than output continuous power) | |||
| Output Wave | Pure Sine Wave | |||
| Distortion THD | THD≤3% | THD≤5% | ||
| Max. Efficiency | 92% | 91% | ||
| No-load Current | <0.9A | <0.5A | <0.9A | <0.5A |
| USB Output Port | 5VDC/Max.1A | |||
| Binding Post | φ6mm | |||
| Dimension | 232.2 x 132 x 74.5mm | |||
| Mounting size | 205 x 102mm | |||
| Mounting hole size | φ5.2mm | |||
| Net weight | 1.7kg | |||
| Operating temperature range | -20℃~+45℃ | |||
| Relative humidity | ≤95%(N.C.) | |||
| Enclosure | IP20 | |||
7. Warranty and Support
EPEVER products are designed for reliability and performance. For any technical assistance, warranty claims, or product support, please contact the authorized EPEVER dealer or the EPEVER customer service directly. Please have your product model (IP500) and purchase information ready when contacting support.