EPEVER LS1024B PWM Solar Charge Controller User Manual
Model: LS1024B | Brand: EPever
1. Product Overview
The EPEVER LS-B series PWM Solar Charge Controller is designed for efficient and reliable management of solar power systems. Featuring a common positive PWM charging mode and an RS485 interface, this controller allows for flexible parameter configuration via communication ports, mobile applications, and PC software. It is ideal for various applications including solar home systems and surveillance systems.
Figure 1: EPEVER LS1024B PWM Solar Charge Controller
Key Features:
Series PWM charging mode for optimal battery charging.
Multiple load control modes: Manual, Light ON/OFF, Light ON + Timer, Time Control.
Full load operation within the specified working temperature range.
Extensive electronic protection features for safety and durability.
Variety of optional accessories for enhanced functionality.
Standard Modbus communication protocol with RS485 interface for monitoring and control.
Figure 2: Product Feature Highlights
2. Components and Indicators
Familiarize yourself with the various components and indicators on your LS1024B controller.
Figure 3: Controller Components and Indicators
Remote Temperature (RTS) Port: For connecting an optional remote temperature sensor.
PV Terminals: Connect to the solar panel array.
Battery Terminals: Connect to the battery bank.
Load Terminals: Connect to the DC load.
RS485 Communication Port: For connecting to PC software or remote meter.
Mounting Hole: For securing the controller.
Load ON/OFF Button: Manually controls the load output.
Load Status Indicator: Shows the status of the connected load.
Battery Status Indicator: Shows the battery charge level.
Charge Status Indicator: Shows the charging status from the PV array.
Note: If the temperature sensor is short-circuited or damaged, the controller will charge or discharge at the default temperature setting of 25 °C (no temperature compensation).
3. Setup and Installation
Proper installation is crucial for the safe and efficient operation of your solar charge controller. Please follow these steps carefully.
Wiring Instructions:
Figure 4: Basic Wiring Diagram
Connect the Battery (1): Connect the battery to the controller's battery terminals. Ensure correct polarity (+ to + and - to -).
Connect the Load (2): Connect the DC load to the controller's load terminals. Ensure correct polarity.
Connect the PV Array (3): Connect the solar panel array to the controller's PV terminals. Ensure correct polarity.
IMPORTANT: Connect the system in the order of ① Battery → ② Load → ③ PV Array. Disconnect the system in the reverse order: ③ PV Array → ② Load → ① Battery.
Note: A fast-blowing fuse or circuit breaker (1.25 to 2 times the rated current) must be installed on the battery side with a distance from the battery not more than 150mm.
Optional Accessories:
Enhance your controller's functionality with these optional accessories:
Remote Temperature Sensor (RTS300R47K3.81A): Figure 5: Remote Temperature Sensor Connects to the RTS port to acquire battery temperature for accurate temperature compensation of control parameters. Standard cable length is 3m. If unplugged, the battery temperature defaults to 25°C.
Remote Meter (MT50): Figure 6: Remote Meter MT50 A wide LED screen that displays real-time operational data and working status in digital, graphic, and textual forms. Used for monitoring and setting controller parameters, it automatically identifies the controller type and model.
USB to RS-485 Converter (CC-USB-RS485-150U): Figure 7: USB to RS-485 Converter Used to monitor the controller on a network using Solar Station PC software and to update firmware. Cable length is 1.5m.
4. Operating Instructions
Load Control Modes:
The controller supports various load control modes, configurable via the Load ON/OFF button or through optional accessories like the MT50 remote meter or PC software:
Manual Control: Turn the load ON/OFF using the button on the controller.
Light ON/OFF: The load turns on at dusk and off at dawn.
Light ON + Timer: The load turns on at dusk and stays on for a set duration.
Time Control: The load operates according to a real-time clock schedule.
Battery Type Selection:
The controller supports different battery types. Ensure you select the correct battery type for optimal charging and discharge management. Options include:
Sealed (Default)
Gel
Flooded
User-defined (customizable parameters)
Monitoring and Parameter Configuration:
For advanced monitoring and parameter adjustments, use the optional MT50 remote meter or the Solar Station PC software connected via the USB to RS-485 converter.
Figure 8: Solar Station PC Software Interface
These tools allow for:
Real-time monitoring of system status (PV voltage/current, battery voltage/current, load status, temperature).
Programming of various parameters, including charge/discharge voltages, load control modes, and battery type.
LVD (Low Voltage Disconnect) or SOC (State of Charge) based load disconnect function.
Energy statistics function to track power generation and consumption.
This section provides solutions to common issues you might encounter with your solar charge controller.
Problem
Possible Cause
Solution
PV array is not charging
PV array is disconnected or reverse connected.
Confirm that PV and battery wire connections are correct and tight.
Battery voltage is lower than 5V.
Battery voltage is too low for the controller to recognize.
Check the battery voltage. If it's below 5V, the controller will not work.
The green indicator light is flashing.
PV open circuit voltage is too low.
Check the PV array connection and ensure sufficient sunlight.
The red battery indicator is solid.
Battery over-discharge.
Waiting for the battery voltage to rise above the Low Voltage Reconnect Voltage (LVR). The load will automatically turn on when the battery voltage recovers.
The red battery indicator is slowly flashing.
Battery over-temperature.
The controller will resume when the battery temperature drops to below 50°C.
Charge, Load, and Discharge indicator flashing.
Controller over-temperature.
Reduce the heat sink of the controller exceeds 65°C. The controller will automatically reduce the input and output current. When the temperature drops to 55°C, the controller will resume work.
Load red indicator slowly flashing.
Overload.
1. Reduce the load power or remove some electrical equipment. 2. Press the Load ON/OFF button. 3. Wait for one night-day cycle.
Load red indicator fast flashing.
Load short circuit.
1. Check carefully for load short circuit. 2. Restart the controller or press the Load ON/OFF button. 3. Wait for one night-day cycle.
For more detailed troubleshooting, refer to the full user manual (if available).
6. Specifications
Detailed technical specifications for the EPEVER LS1024B PWM Solar Charge Controller.
Regular maintenance ensures the longevity and optimal performance of your solar charge controller.
Cleanliness: Keep the controller clean and free from dust and debris. Use a dry cloth for cleaning.
Connections: Periodically check all wiring connections for tightness and corrosion. Loose connections can lead to power loss or overheating.
Ventilation: Ensure adequate airflow around the controller to prevent overheating. Do not block ventilation openings.
Environmental Conditions: Ensure the controller is installed in an environment within its specified operating temperature and humidity ranges.
8. User Tips
Always ensure the battery is connected first and disconnected last to prevent damage to the controller.
For accurate temperature compensation, ensure the remote temperature sensor (if used) is properly connected and placed near the battery.
Utilize the PC software or remote meter for detailed monitoring and fine-tuning of parameters to optimize your solar system's performance.
9. Warranty and Support
This product comes with a warranty provided by SHANGHAI TINGEN ELECTRIC CO., LTD.
Warranty: 12/24 months Warranty (specific terms may vary, please refer to your purchase documentation).
Life-long maintenance service for the product.
Terrific after-sales service: 24 hours around the clock.
Contact Information:
SHANGHAI TINGEN ELECTRIC CO., LTD TEL: 0086-21-55596836 FAX: 0086-21-51685686 MSN: shtepower@hotmail.com SKYPE: SHTEPOWER Email: sales@shtepower.com WhatsApp: +8618930085899 Facebook: shtepower@hotmail.com ADD: NO. 6066, Songze Road, Qingpu Dist. SHANGHAI, 201706 CHINAFigure 9: Global Presence and Contact Information
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.