1. General Information
The EPEVER MT52 Remote Meter is designed to monitor the real-time working status and program parameters of EPEVER solar charge controllers equipped with RS485 communication. It provides an intuitive LCD interface for system data monitoring, parameter modification, and restoring factory defaults.
1.1 Features
- Easy to install and operate.
- Real-time display of fault alarms.
- Locally reading of real-time parameters.
- Powered directly by the controller.
- Equipped with an RJ45 communication port.
1.2 Applicable Models and Recommendations
The MT52 is compatible with various EPEVER controller series. When connected to different devices, the configurable battery types may vary. Refer to the table below for compatibility and interface types.
| Product Series | Battery Type | Interface Type | Communication |
|---|---|---|---|
| LS-B, GM-N, VS-BN, Tracer-BN | Lead-acid battery, user define | RJ45 | RS485 |
| iTracer-AD/ND | Lead-acid battery, user define | 3.81-4P | |
| Tracer-BP, Tracer-CPN | Lead-acid battery, lithium battery, user define | RS485 waterproof port | |
| Tracer-AN (10A~40A), Tracer-AN(50A~100A), Tracer-AN G3, TRIRON, XTRA-N, XTRA-N G3 | Lead-acid battery, lithium battery, user define | RJ45 |
Note: The MT52 comes standard with an RS485 communication cable (CC-RS485-RS485-200U). If connecting to a controller with a non-standard RJ45 interface, an appropriate communication cable must be purchased in advance. Avoid installing the MT52 in environments with strong electromagnetic interference.
2. Important Safety Instructions
SAVE THESE INSTRUCTIONS
- Inspect the MT52 thoroughly upon delivery. Report any damage to the shipping company or manufacturer immediately.
- Read all instructions and cautions in this manual before installation.
- Keep the MT52 away from rain, direct exposure, severe dust, vibrations, corrosive gases, and intense electromagnetic interference.
- Prevent water from entering the remote meter.
- The remote meter contains no user-serviceable parts. Do not disassemble or attempt repairs.
Do not install this product in humid, salt spray, corrosive, greasy, flammable, explosive, or dust accumulative environments.
3. Installation
3.1 Frame Mount Dimensions
The following diagram and table provide the dimensions for frame mounting.

Figure: MT52 Remote Meter with mounting frame dimensions.
| Mechanical Parameter | Parameter |
|---|---|
| Overall dimension | 114mm x 114mm x 48.2mm |
| Mounting dimension | 84mm x 84mm |
| Screw hole dimension | Φ5 |
3.2 Mounting on the Wall
- Step 1: Locate and drill screw holes based on the frame mounting dimension of the base, and install the plastic expansion bolts.
- Step 2: Fix the frame with four ST4.2×3 self-tapping cross recessed pan head screws.
- Step 3: Use four M4×8 pan head screws to mount the MT52 panel on the frame.
- Step 4: Mount the four associated screw plugs into the screw holes.

Figure: Wall mounting steps for MT52 Remote Meter.
3.3 Mounting on the Panel Surface
- Step 1: Locate and drill screw holes based on the installation size of the surface.
- Step 2: Use four M4×8 cross recessed pan head screws with M4 nuts to mount the MT52 panel onto the surface.
- Step 3: Mount the four associated white screw plugs into the screw holes.
Note: Take full consideration of the plugging/unplugging space and the length of the communication cable during installation.
4. Product Features and Components
4.1 Front View
The front panel of the MT52 features a display screen, operational buttons, and indicators.

Figure: MT52 Remote Meter Front View with labeled components.
- Failure Indicator: Flashes when a fault occurs. Refer to the controller's user manual for detailed fault information.
- Communication Indicator (COM): Indicates the communication status between the MT52 and the connected controller.
- Display Screen: Man-machine interface for monitoring and programming.
- Buttons: Used for navigation and operation.
4.2 Rear View
The rear panel includes the communication and power interface.

Figure: MT52 Remote Meter Rear View with labeled RJ45 interface.
- RJ45 Interface (RS485 Communication and Power Interface): Connects to the controller for communication and power supply.
RJ45 Pin Definition
| Pin No. | Definition |
|---|---|
| 1 | +5~12V Power input |
| 2 | +5~12V Power input |
| 3 | RS485-B |
| 4 | RS485-B |
| 5 | RS485-A |
| 6 | RS485-A |
| 7 | GND |
| 8 | GND |
5. Operation
5.1 Buttons
The MT52 features six buttons: "ESC", "Left", "Up", "Down", "Right", and "OK". These buttons are used for navigation and parameter modification.
The default entry page is the browse mode. To enter modification mode, press the "OK" button and input the correct password. The "Left" and "Right" buttons move the cursor, while "Up" and "Down" buttons modify parameter values. "OK" confirms changes, and "ESC" cancels them.
5.2 Main Menu
Enter the Main Menu by pressing "ESC". Use "Up" and "Down" to select menu items, and "OK" or "ESC" to enter or exit pages.
- Monitoring
- Device Info.
- Test Operation
- Control Para.
- Load Set
- Device Para
- Device PSW.
- Factory Reset
- Failure Info.
- Meter Para.
5.3 Real-time Monitoring
The real-time monitoring screen displays various system data. The display screen can be viewed clearly when the angle between the user's horizontal sight and the screen is within 90°.
Monitoring Screen Icons and Instructions
| Name | LCD Display | Instruction |
|---|---|---|
| Day and night icons | Night / Day | Indicates night or day. Day is indicated when PV input voltage is higher than 1V. |
| Charge current icon | >>> | Dynamically running when there is a charge current. |
| Battery icon | Battery symbol | Dynamically displays battery capacity. Shows 'X' when battery is over-discharged. |
| Battery status icons | Smiley faces | Indicates Normal battery voltage, Battery under voltage, Battery over-discharge. |
| Load current icon | >>>>> | Dynamically running when there is a discharge current. |
| Load status icon | Light bulb / Plug | Indicates Load On / Load Off. In Manual Mode, press "OK" to switch load on/off. |
| PV vol. and cur. values | e.g., 17.5V 15.2A | Displays PV voltage and current. |
| Battery vol. and cur. values | e.g., 13.8V 5.2A | Displays battery voltage and current. |
| Load vol. and cur. values | e.g., 13.8V 10.0A | Displays load voltage and current. |
5.4 Device Information
This section displays the controller's parameters such as Rated Voltage, Charging Current, and Discharging Current.
- Rate.Vol: 12V
- Char.Cur: 10.0A
- Disc.Cur: 2.6A
Use the "Up" and "Down" buttons to navigate through the browse page.
5.5 Test Operation
A load switch test can be performed to check if the load output is normal. This test does not affect the working settings under actual load. The solar controller will exit test mode upon exiting this page.
To perform a test: Enter the page and input the correct password. Use the navigation buttons to modify the On/Off status. Press "OK" to confirm and "ESC" to cancel.
5.6 Control Parameters
This section allows browsing and modification of the solar controller's control parameters, including battery type, voltage settings, and temperature compensation.
Battery Type Settings
Supported battery types include Sealed, Gel, Flooded, LiFePO4, Li(NiCoMn)O2, and User-defined. The availability of LiFePO4 15S/16S and Li(NiCoMn)O2 13S/14S options depends on the controller supporting 48V system voltage.
When "User define" is selected, the default voltage point is the corresponding voltage before modification.
Note: For lithium battery types (LiFePO4 and Li(NiCoMn)O2), "Temp Comp. Coeff" and "Rated Voltage" cannot be set, and the "Low temperature prohibits charge and discharge" protection function is automatically enabled.
Battery Charging Parameters (12V/25°C)
| Parameter | Sealed | Gel | Flooded | User |
|---|---|---|---|---|
| Over voltage disconnect voltage | 16.0V | 16.0V | 16.0V | 9~17V |
| Charging limit voltage | 15.0V | 15.0V | 15.0V | 9~17V |
| Over voltage reconnect voltage | 15.0V | 15.0V | 15.0V | 9~17V |
| Equalize charging voltage | 14.6V | — | 14.8V | 9~17V |
| Boost charging voltage | 14.4V | 14.2V | 14.6V | 9~17V |
| Float charging voltage | 13.8V | 13.8V | 13.8V | 9~17V |
| Boost reconnect charging Voltage | 13.2V | 13.2V | 13.2V | 9~17V |
| Low voltage reconnect voltage | 12.6V | 12.6V | 12.6V | 9~17V |
| Under voltage warning reconnect voltage | 12.2V | 12.2V | 12.2V | 9~17V |
| Under voltage warning voltage | 12.0V | 12.0V | 12.0V | 9~17V |
| Low voltage disconnect voltage | 11.1V | 11.1V | 11.1V | 9~17V |
| Discharging limit voltage | 10.6V | 10.6V | 10.6V | 9~17V |
| Equalize duration | 120min | — | 120min | 0~180min |
| Boost duration | 120min | 120min | 120min | 10~180min |
Note: Double the values for 24V systems and multiply by 4 for 48V systems.
When the battery type is "USE", specific voltage parameter logic applies. Refer to the controller manual for detailed logic.
5.7 Load Setting
The load setting page allows configuration of four load working modes for the connected solar controller: Manual, Light On/off, Light On + Timer, and Time Control.
Load Working Modes
| Mode | Description |
|---|---|
| Manual Control | Load is ON if battery capacity is sufficient and no abnormal conditions exist. Load is OFF all the time. |
| Light On/Off | Load output turns ON automatically when PV input voltage is lower than Light On voltage, battery capacity is sufficient, and no abnormal conditions exist. Load output turns OFF automatically when PV input voltage is higher than Light Off voltage. |
| Light On + Timer | Load turns on after light control, then operates for a set working period (T1). An optional second working period (T2) can be set before the load turns off. Night-time is calculated (≥3h). |
| Time Control | Controls load on/off times through a real-time clock. Working time 1 is compulsory, working time 2 is optional. |
For detailed instructions on load settings, please refer to the relevant solar controller manual.
5.8 Device Parameter
This page allows checking and modifying the solar controller's software version, device ID, LCD backlight time, and device clock.
| Type | Notes |
|---|---|
| Ver | Indicates the Solar controller's software and hardware version numbers. |
| ID | Indicates the Solar controller's communication ID numbers. |
| Bklight | Indicates the Solar controller's LCD backlight time. |
| Month-Day-Year H: M: S | Indicates the Solar controller's internal clock. |
Note: A larger connection device ID value results in a longer communication identification interval (maximum <6 minutes).
5.9 Device Password
The solar controller's password can be modified via this page. A 6-digit figure is required to enter modification mode for "Control parameter," "Load setting," "Device parameter," "Device password," and "Factory reset" pages. The default password is "000000".
5.10 Factory Reset
This page allows restoring the solar charger controller's default parameters. This includes "Control parameter," "Load setting," "Charge mode," and "Device password." The factory default password is "000000".
5.11 Meter Parameter
This section allows checking the meter's model, software, and hardware version. Parameters like "Switch pages" (Sw-Pages) and "Backlight" (Bklight) can also be browsed and modified.
| Parameters | Default | Range | Remark |
|---|---|---|---|
| Sw-Pages | 0 | 0~120S | Set the automatic switching interval for the real-time monitoring pages. |
| BKlight | 20 | 0~999S | Set the LCD backlight time. |
| LangSel. | Cn | Cn/En | Switch the display language between Chinese and English. |
To enter the language selection page, long-press the "Left", "Up", "Down", and "Right" buttons simultaneously on any page.
6. Troubleshooting: Failure Information
The MT52 can display up to 15 failure messages. These messages are automatically cleared once the underlying fault in the solar controller is resolved.
Common Failure Information
| Failure Type | LCD Display | Instructions |
|---|---|---|
| Charging device failures | Load MOS-Short | The MOSFET of the load driver is short-circuited. |
| Load Circuit | The load circuit is short-circuited. | |
| Load O. cur. | The load circuit is over current. | |
| Controller failure | Input O. cur. | The PV input current exceeds the rated current. |
| RPP Short | The MOSFET of the reverse polarity protection (RPP) is short-circuited. | |
| RPP Break | The MOSFET of the reverse polarity protection (RPP) breaks. | |
| Char. MOS-Short | The MOSFET of the charge driver is short-circuited. | |
| No Input Power | The input power is not connected successfully. | |
| Input vol. High/Low | The input voltage is very high/low. | |
| Communication failure | Comm. Timeout | The communication is timeout. |
| Battery failures | Batt. O. Hi. Temp. | The battery is over high temperature. |
| Batt. O. Lo. Temp. | The battery is over low temperature. | |
| Batt. I. R. Eorr | The internal resistance of the battery is in error. | |
| Rated Vol Err. | The rated voltage is in error. | |
| Batt. OVD | The battery voltage exceeds the over voltage disconnect (OVD) voltage value. | |
| Batt. UVW / Batt. LVD | The battery voltage is lower than the under voltage warning (UVW) or low voltage disconnect (LVD) voltage value. | |
| General | Batt. Err | The battery type is in error. |
7. Technical Specifications
| Electrical Parameter | |
|---|---|
| Self-consumption | Backlight ON < 23mA |
| Backlight OFF < 15mA | |
| Mechanical Parameter | |
|---|---|
| Faceplate dimension | 98mm × 98mm |
| Frame dimension | 114mm × 114mm |
| Communication port | RJ45 |
| Communication cable (m) | Standard: 2m, Longest: 50m |
| Net weight | Simple package: 0.23 Kg |
| Standard package: 0.32kg | |
| Environmental Parameter | |
|---|---|
| Environment temperature | -20°C ~ +70°C |
Dimensions
Detailed dimensions of the MT52 Remote Meter are provided in the diagrams below (Unit: mm).

Figure: MT52 Remote Meter Appendix Dimensions.
8. User Tips
- Always ensure your solar charge controller model is compatible with the MT52 Remote Meter by checking the "Applicable Models" section before installation.
- When setting battery parameters, especially for "User define" types, carefully review the voltage parameter logic in your main controller's manual to prevent misconfiguration.
- The default password for accessing modification modes is "000000". It is recommended to change this password after initial setup for security.
- If you encounter communication issues, verify the RJ45 cable connection and ensure the MT52 is not in an environment with strong electromagnetic interference.
9. Warranty and Maintenance
Maintenance Procedure
Before seeking maintenance, consult this user manual or contact after-sales personnel to troubleshoot any faults. If factory maintenance is required, send the product to the company via express delivery, prepaying shipping costs. Include the purchase invoice as proof of warranty.
To facilitate quick warranty service, provide the model number, usage environment data, and a detailed description of the fault with the returned product.
The manufacturer is not responsible for damages resulting from improper use or failure to follow this user manual. Maintenance costs will be incurred if the device is damaged due to customer misuse.
10. Support
For further assistance or to view the full user manual in PDF format, please refer to the official EPEVER website or contact their customer support. The PDF manual can be found at EPEVER MT52 User Manual (PDF).
Any changes to the product specifications are subject to change without prior notice. Version number: V1.0.
Manufactured by HUIZHOU EPEVER TECHNOLOGY CO., LTD.