1. Introduction
The EPEVER UPower Series Inverter/Charger is an all-in-one unit combining an MPPT solar charge controller, a pure sine wave inverter, and an AC/DC charger. Designed for residential applications, schools, cottages, and areas with unstable electricity, it provides uninterruptible power. This manual will guide you through the installation, operation, and maintenance of your UP5000-M10342.

The EPEVER UPower Inverter/Charger integrated into a solar power system.
2. Features
The EPEVER UPower Series Inverter/Charger offers a comprehensive set of features for efficient power management:
- A new type of all-digital intelligent energy storage and management Inverter/charger.
- MPPT technology, with a maximum tracking efficiency of 99.5% and a maximum DC-DC conversion efficiency of 98.5%.
- Advanced all-digital control technology for AC-DC charging modules.
- SPWM technology, with high efficiency up to 95%.
- Functionality for Utility & Solar charging ratio selection, and total charging current setting.
- Four charging modes and two output modes.
- Rich set of configurable options.
- RS485 isolated communication interface with standard Modbus protocol.
- Extensive electronic protections for safe operation.
- Variety of accessories can be selected according to user's requirements.

Key features of the UPower Inverter/Charger.

Additional characteristics including pure sine wave output, MPPT technology, and comprehensive protections.

Further characteristics highlighting high efficiency, multiple operating modes, and communication capabilities.

Characteristics emphasizing high reliability, intelligent control, and wide application scenarios.
3. Package Contents
Upon unpacking your EPEVER UPower Inverter/Charger, please verify that all the following items are included:
- EPEVER UPower Inverter/Charger Unit
- User Manual
- Certificate
- Installation Accessories (screws, wrenches, cable lugs, etc.)

The EPEVER UPower Inverter/Charger unit along with its accessories.

Detailed view of the included installation accessories.

Additional view of the installation accessories.
4. Product Overview and Components
Familiarize yourself with the various parts and interfaces of your EPEVER UPower Inverter/Charger:

Front and rear views of the inverter/charger with numbered components.
- Ventilation
- Captive screw (2 pcs)
- AC output terminals
- Utility input terminals
- Battery input terminals
- RTS* interface (Remote Temperature Sensor)
- Relay interface
- Remote interface
- RS485 interface (5VDC/200mA)
- Inverter/charger switch
- PV input terminals
- Terminals cover
*Note: If the temperature sensor is short-circuited or damaged, the controller will charge or discharge at the default temperature of 25°C.
5. Setup and Installation
WARNING: Power on the inverter/charger operation must be performed by professional personnel only!
5.1 System Diagram
The following diagrams illustrate the typical connections for the EPEVER UPower Inverter/Charger in a solar power system.

Simplified system diagram for the UPower Inverter/Charger.
WARNING: Confirm the AC load power is compatible with the power of the inverter/charger. Selecting an AC load exceeding the maximum output power of the inverter/charger is prohibited.

Detailed wiring diagram including solar panels, generator/utility, AC loads, and battery bank with breakers and SPD.
5.2 Installation Steps (General Guidelines)
This is a general guide. Always refer to the detailed instructions in the full user manual for specific wiring and safety procedures.
- Mounting: Securely mount the inverter/charger in a well-ventilated area, ensuring adequate clearance around the ventilation openings (1) for proper airflow.
- Battery Connection: Connect the battery input terminals (5) to your 48V battery bank. Ensure correct polarity (positive to positive, negative to negative) and use appropriate cable gauges.
- PV Array Connection: Connect the PV input terminals (11) to your solar panel array. Verify that the total PV open circuit voltage and input power do not exceed the specified limits (refer to Specifications section).
- Utility Input Connection: Connect the utility input terminals (4) to your AC grid or generator.
- AC Output Connection: Connect the AC output terminals (3) to your AC loads. Ensure the total connected load does not exceed the inverter's continuous output power.
- Optional Connections: If desired, connect the Remote Temperature Sensor (RTS) (6), Relay interface (7), Remote interface (8), and RS485 interface (9) for enhanced monitoring and control.
- Power On: After all connections are securely made and verified, turn on the inverter/charger using the Inverter/charger switch (10).
6. Operating Instructions
Once installed and powered on, the EPEVER UPower Inverter/Charger operates largely automatically, managing power flow between your solar array, utility grid, battery bank, and AC loads.
- System Monitoring: The integrated display panel provides real-time information on system status, battery voltage, charging current, output power, and more.
- Charging Modes: The unit supports four charging modes and two output modes. These can be configured to prioritize solar charging, utility charging, or a combination, depending on your energy management strategy. Refer to the comprehensive user manual for detailed parameter settings and configuration options.
- Pure Sine Wave Output: The inverter provides a pure sine wave AC output, suitable for all types of electronic devices and appliances.
7. Maintenance
Regular maintenance helps ensure the longevity and optimal performance of your inverter/charger:
- Ventilation: Periodically check and clear any obstructions from the ventilation openings to ensure proper heat dissipation.
- Connections: Annually inspect all wiring connections (battery, PV, utility, AC output) for tightness, corrosion, and damage. Tighten any loose connections.
- Cleanliness: Keep the unit clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
- Battery Inspection: Follow the manufacturer's maintenance guidelines for your specific battery bank.
8. Troubleshooting
Here are some common issues and basic troubleshooting steps. For more complex problems or error codes, consult the full user manual.
- No Power Output:
- Check if the inverter/charger switch (10) is in the 'ON' position.
- Verify battery connections (5) are secure and the battery bank has sufficient charge.
- Ensure PV input (11) and Utility input (4) sources are active and connected correctly.
- Overload Warning:
- The total AC load connected to the output terminals (3) exceeds the inverter's capacity. Reduce the number of active appliances.
- Check for any short circuits in the AC load wiring.
- Charging Issues:
- For solar charging, ensure PV array connections (11) are correct and there is sufficient sunlight.
- For utility charging, verify the utility input (4) is active and within the specified voltage range.
- If the Remote Temperature Sensor (RTS) (6) is damaged or short-circuited, charging will default to 25°C, which might affect charging performance in extreme temperatures.
- Display Not Working:
- Check the main power supply to the unit.
- Ensure the battery is connected and charged.
9. Specifications
The technical specifications for the EPEVER UPower Series Inverter/Charger UP5000-M10342 are detailed below:
| Parameter | Value (UP5000-M10342) |
|---|---|
| Model Number | UP5000-M10342 |
| Nominal Battery Voltage | 48VDC |
| Battery Input Voltage Range | 41.2 - 64VDC |
| Inverter Output | |
| Continuous Output Power | 4000W |
| Output Power (15 min.) | 5000W |
| Overload Power (5s) | 8000W |
| Max. Surge Power | 10000W |
| Output Voltage | 220V/230V (±5%) |
| Output Frequency | 50/60Hz (±0.1Hz) |
| Output Mode | Single-phase |
| Output Wave | Pure Sine Wave |
| Distortion THD | ≤3% (24V or 48V resistive load) |
| Max. Efficiency | 95% |
| Utility Charging | |
| Utility Input Voltage Range | 185VAC - 265VAC (Working); 170VAC - 270VAC (Starting) |
| Max. Utility Charge Current | 30A |
| Solar Charging | |
| Max. PV Open Circuit Voltage | 200V (min. operating temp); 180V (25°C operating temp) |
| Max. PV Input Power | 5000W |
| Max. PV Charging Current | 100A |
| Tracking Efficiency | ≥99.5% |
| Charging Conversion Efficiency | ≥98% |
| Other | |
| No Load Consumption | ≤0.2A |
| Enclosure | IP30 |
| Operating Temperature Range | -20°C ~ 55°C (full input and output with no derating) |
| Dimensions (H×W×L) | 605*315*178mm |
| Net Weight | 17.8kg |
| Certification | CE, RoHS |
Technical specifications for the EPEVER UPower Series Inverter/Charger UP5000-M10342.
10. Warranty and Support
For detailed warranty information, technical assistance, and after-sales service, please refer to the official EPEVER documentation included with your product or visit the EPEVER website.
You may also contact the seller, SHANGHAI TINGEN ELECTRIC CO., LTD., for support:
- Telephone: 0086-21-55596836
- Fax: 0086-21-51685686
- MSN: shtepower@hotmail.com
- Email: sales@shtepower.com
- Facebook: shtepower@hotmail.com
- Skype: SHTEPOWER
- WhatsApp: +8618930085899
They offer 24-hour customer service and a 12/24 month warranty, along with life-long maintenance service for the product.