EPEVER UP5000-M10342

Contents
EPEVER UPower Inverter/Charger logo and key specifications

EPEVER UPower Series Inverter/Charger UP5000-M10342 User Manual

Model: UP5000-M10342

5000W Pure Sine Wave Inverter with 100A MPPT Solar Charge Controller and 30A Utility Charger

1. Introduction

The EPEVER UPower Series Inverter/Charger is an all-in-one unit combining an MPPT solar charge controller, a pure sine wave inverter, and an AC/DC charger. Designed for residential applications, schools, cottages, and areas with unstable electricity, it provides uninterruptible power. This manual will guide you through the installation, operation, and maintenance of your UP5000-M10342.

EPEVER UPower Inverter/Charger in a solar power setup

The EPEVER UPower Inverter/Charger integrated into a solar power system.

2. Features

The EPEVER UPower Series Inverter/Charger offers a comprehensive set of features for efficient power management:

  • A new type of all-digital intelligent energy storage and management Inverter/charger.
  • MPPT technology, with a maximum tracking efficiency of 99.5% and a maximum DC-DC conversion efficiency of 98.5%.
  • Advanced all-digital control technology for AC-DC charging modules.
  • SPWM technology, with high efficiency up to 95%.
  • Functionality for Utility & Solar charging ratio selection, and total charging current setting.
  • Four charging modes and two output modes.
  • Rich set of configurable options.
  • RS485 isolated communication interface with standard Modbus protocol.
  • Extensive electronic protections for safe operation.
  • Variety of accessories can be selected according to user's requirements.
Graphic illustrating key features with icons

Key features of the UPower Inverter/Charger.

Graphic illustrating characteristics like pure sine wave, MPPT, and multiple protections

Additional characteristics including pure sine wave output, MPPT technology, and comprehensive protections.

Graphic illustrating characteristics like high efficiency, multiple modes, and communication ports

Further characteristics highlighting high efficiency, multiple operating modes, and communication capabilities.

Graphic illustrating characteristics like high reliability, intelligent control, and wide application

Characteristics emphasizing high reliability, intelligent control, and wide application scenarios.

3. Package Contents

Upon unpacking your EPEVER UPower Inverter/Charger, please verify that all the following items are included:

  • EPEVER UPower Inverter/Charger Unit
  • User Manual
  • Certificate
  • Installation Accessories (screws, wrenches, cable lugs, etc.)
EPEVER UPower Inverter/Charger and included accessories

The EPEVER UPower Inverter/Charger unit along with its accessories.

Close-up view of various installation accessories

Detailed view of the included installation accessories.

Another close-up view of installation accessories

Additional view of the installation accessories.

4. Product Overview and Components

Familiarize yourself with the various parts and interfaces of your EPEVER UPower Inverter/Charger:

Front and rear view of the EPEVER UPower Inverter/Charger with labeled components

Front and rear views of the inverter/charger with numbered components.

  1. Ventilation
  2. Captive screw (2 pcs)
  3. AC output terminals
  4. Utility input terminals
  5. Battery input terminals
  6. RTS* interface (Remote Temperature Sensor)
  7. Relay interface
  8. Remote interface
  9. RS485 interface (5VDC/200mA)
  10. Inverter/charger switch
  11. PV input terminals
  12. Terminals cover

*Note: If the temperature sensor is short-circuited or damaged, the controller will charge or discharge at the default temperature of 25°C.

5. Setup and Installation

WARNING: Power on the inverter/charger operation must be performed by professional personnel only!

5.1 System Diagram

The following diagrams illustrate the typical connections for the EPEVER UPower Inverter/Charger in a solar power system.

Simplified system diagram showing PV array, utility, inverter/charger, battery, and AC loads

Simplified system diagram for the UPower Inverter/Charger.

WARNING: Confirm the AC load power is compatible with the power of the inverter/charger. Selecting an AC load exceeding the maximum output power of the inverter/charger is prohibited.

Detailed wiring diagram for EPEVER UPower Inverter/Charger with solar panels, generator, utility, batteries, and AC loads

Detailed wiring diagram including solar panels, generator/utility, AC loads, and battery bank with breakers and SPD.

5.2 Installation Steps (General Guidelines)

This is a general guide. Always refer to the detailed instructions in the full user manual for specific wiring and safety procedures.

  1. Mounting: Securely mount the inverter/charger in a well-ventilated area, ensuring adequate clearance around the ventilation openings (1) for proper airflow.
  2. Battery Connection: Connect the battery input terminals (5) to your 48V battery bank. Ensure correct polarity (positive to positive, negative to negative) and use appropriate cable gauges.
  3. PV Array Connection: Connect the PV input terminals (11) to your solar panel array. Verify that the total PV open circuit voltage and input power do not exceed the specified limits (refer to Specifications section).
  4. Utility Input Connection: Connect the utility input terminals (4) to your AC grid or generator.
  5. AC Output Connection: Connect the AC output terminals (3) to your AC loads. Ensure the total connected load does not exceed the inverter's continuous output power.
  6. Optional Connections: If desired, connect the Remote Temperature Sensor (RTS) (6), Relay interface (7), Remote interface (8), and RS485 interface (9) for enhanced monitoring and control.
  7. Power On: After all connections are securely made and verified, turn on the inverter/charger using the Inverter/charger switch (10).

6. Operating Instructions

Once installed and powered on, the EPEVER UPower Inverter/Charger operates largely automatically, managing power flow between your solar array, utility grid, battery bank, and AC loads.

  • System Monitoring: The integrated display panel provides real-time information on system status, battery voltage, charging current, output power, and more.
  • Charging Modes: The unit supports four charging modes and two output modes. These can be configured to prioritize solar charging, utility charging, or a combination, depending on your energy management strategy. Refer to the comprehensive user manual for detailed parameter settings and configuration options.
  • Pure Sine Wave Output: The inverter provides a pure sine wave AC output, suitable for all types of electronic devices and appliances.

7. Maintenance

Regular maintenance helps ensure the longevity and optimal performance of your inverter/charger:

  • Ventilation: Periodically check and clear any obstructions from the ventilation openings to ensure proper heat dissipation.
  • Connections: Annually inspect all wiring connections (battery, PV, utility, AC output) for tightness, corrosion, and damage. Tighten any loose connections.
  • Cleanliness: Keep the unit clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
  • Battery Inspection: Follow the manufacturer's maintenance guidelines for your specific battery bank.

8. Troubleshooting

Here are some common issues and basic troubleshooting steps. For more complex problems or error codes, consult the full user manual.

  • No Power Output:
    • Check if the inverter/charger switch (10) is in the 'ON' position.
    • Verify battery connections (5) are secure and the battery bank has sufficient charge.
    • Ensure PV input (11) and Utility input (4) sources are active and connected correctly.
  • Overload Warning:
    • The total AC load connected to the output terminals (3) exceeds the inverter's capacity. Reduce the number of active appliances.
    • Check for any short circuits in the AC load wiring.
  • Charging Issues:
    • For solar charging, ensure PV array connections (11) are correct and there is sufficient sunlight.
    • For utility charging, verify the utility input (4) is active and within the specified voltage range.
    • If the Remote Temperature Sensor (RTS) (6) is damaged or short-circuited, charging will default to 25°C, which might affect charging performance in extreme temperatures.
  • Display Not Working:
    • Check the main power supply to the unit.
    • Ensure the battery is connected and charged.

9. Specifications

The technical specifications for the EPEVER UPower Series Inverter/Charger UP5000-M10342 are detailed below:

ParameterValue (UP5000-M10342)
Model NumberUP5000-M10342
Nominal Battery Voltage48VDC
Battery Input Voltage Range41.2 - 64VDC
Inverter Output
Continuous Output Power4000W
Output Power (15 min.)5000W
Overload Power (5s)8000W
Max. Surge Power10000W
Output Voltage220V/230V (±5%)
Output Frequency50/60Hz (±0.1Hz)
Output ModeSingle-phase
Output WavePure Sine Wave
Distortion THD≤3% (24V or 48V resistive load)
Max. Efficiency95%
Utility Charging
Utility Input Voltage Range185VAC - 265VAC (Working); 170VAC - 270VAC (Starting)
Max. Utility Charge Current30A
Solar Charging
Max. PV Open Circuit Voltage200V (min. operating temp); 180V (25°C operating temp)
Max. PV Input Power5000W
Max. PV Charging Current100A
Tracking Efficiency≥99.5%
Charging Conversion Efficiency≥98%
Other
No Load Consumption≤0.2A
EnclosureIP30
Operating Temperature Range-20°C ~ 55°C (full input and output with no derating)
Dimensions (H×W×L)605*315*178mm
Net Weight17.8kg
CertificationCE, RoHS

Technical specifications for the EPEVER UPower Series Inverter/Charger UP5000-M10342.

10. Warranty and Support

For detailed warranty information, technical assistance, and after-sales service, please refer to the official EPEVER documentation included with your product or visit the EPEVER website.

You may also contact the seller, SHANGHAI TINGEN ELECTRIC CO., LTD., for support:

  • Telephone: 0086-21-55596836
  • Fax: 0086-21-51685686
  • MSN: shtepower@hotmail.com
  • Email: sales@shtepower.com
  • Facebook: shtepower@hotmail.com
  • Skype: SHTEPOWER
  • WhatsApp: +8618930085899

They offer 24-hour customer service and a 12/24 month warranty, along with life-long maintenance service for the product.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.