1. Introduction
Thank you for choosing the EPever RTS300R47K3.81A TS-R Remote Temperature Sensor. This sensor is designed to provide accurate battery temperature readings to compatible EPever/EPsolar solar charge controllers, enabling precise temperature compensation for optimal battery charging and extended battery life in various solar working station applications.
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your temperature sensor. Please read it thoroughly before use.
2. Key Features
- Accurate temperature measurement for battery temperature compensation.
- Optimizes charging parameters to prolong battery lifespan.
- Compatible with a wide range of EPever/EPsolar controllers, including:
- Tracer-AN Series (50-100A, 10-40A)
- XTRA Series
- Triron Series
- VS-BN Series
- VS-AU Series
- LS-B Series
- DuoRacer Series
- MSC-N Series
- Tracer-BN Series
- UPower Series
- UPower-Hi Series
- GoMate Series
- Cable length: 3 meters.
- CE Certified.
3. Specifications
| Parameter | Value |
|---|---|
| Model | RTS300R47K3.81A TS-R |
| Application | Solar Working Station |
| Cable Length | 3 meters (3m) |
| Certification | CE |
| High-concerned chemical | None |
| Customization | Yes (is_customized) |
Note: Package dimensions (Length: 19cm, Width: 9cm, Height: 3cm, Weight: 0.058kg) are for shipping purposes and do not reflect the product's operational size.
4. Package Contents
Depending on your order, the package may include:
- EPever RTS300R47K3.81A TS-R Remote Temperature Sensor Cable (3m)
- (Optional) EPever USB-RS485 Communication Cable (CC-USB-RS485-150U)



5. Setup and Installation
Follow these steps to properly install your EPever Remote Temperature Sensor:
- Identify the Temperature Sensor Port: Locate the dedicated temperature sensor port on your compatible EPever/EPsolar solar charge controller. This port is typically labeled "RTS" or "Temp Sensor". Refer to your controller's manual for its exact location.
- Connect the Sensor: Carefully insert the connector of the RTS300R47K3.81A sensor cable into the temperature sensor port on the controller. Ensure a firm and secure connection.
- Position the Sensor: Place the metal tip of the temperature sensor in close proximity to or directly on the battery bank whose temperature you wish to monitor. For optimal accuracy, the sensor should be placed on the side of the battery, away from direct sunlight or heat sources that could skew readings.
- Secure the Cable: Route the sensor cable neatly and securely, avoiding sharp edges, moving parts, or areas where it could be pinched or damaged. Use cable ties if necessary.
- Verify Connection: After connecting, check your solar charge controller's display or monitoring software (if applicable) to confirm that a temperature reading is being displayed. This indicates a successful connection.
Important: Always ensure your solar charge controller is powered off before connecting or disconnecting any accessories to prevent potential damage.
6. Operation
Once correctly installed, the EPever RTS300R47K3.81A TS-R Remote Temperature Sensor operates automatically. It continuously monitors the battery temperature and transmits this data to the connected EPever/EPsolar solar charge controller.
- Automatic Temperature Compensation: The solar charge controller uses the temperature data from the sensor to adjust its charging voltage parameters. This compensation ensures that the battery is charged at the correct voltage regardless of ambient temperature fluctuations, which is crucial for battery health and longevity.
- Monitoring: You can typically view the real-time battery temperature on your solar charge controller's LCD display or through its associated PC/mobile monitoring software (if a communication cable like the USB-RS485 is used).
7. Care and Maintenance
The EPever Remote Temperature Sensor is designed for durability, but proper care will ensure its long-term performance:
- Regular Inspection: Periodically check the sensor cable and its connections for any signs of wear, damage, or corrosion.
- Cleanliness: Keep the sensor tip clean and free from dirt, dust, or debris, which could affect its accuracy. Use a soft, dry cloth for cleaning.
- Environmental Protection: While designed for outdoor use, protect the sensor and cable from extreme physical stress, prolonged immersion in water (unless specified as waterproof), or direct exposure to harsh chemicals.
- Cable Management: Ensure the cable remains securely routed and is not subjected to tension or sharp bends.
8. Troubleshooting
If you encounter issues with your temperature sensor, consider the following:
| Problem | Possible Cause | Solution |
|---|---|---|
| No temperature reading on controller. | Sensor not properly connected or faulty cable. | Ensure the sensor is firmly plugged into the controller's RTS port. Inspect the cable for visible damage. Try reconnecting. |
| Inaccurate temperature readings. | Sensor tip not properly placed or dirty. | Ensure the sensor tip is in good contact with the battery and is clean. Avoid placing it in direct sunlight or near other heat sources. |
| Controller not compensating for temperature. | Sensor not recognized or controller settings. | Verify the sensor is connected and providing a reading. Check your controller's settings to ensure temperature compensation is enabled. Consult your controller's manual. |
9. User Tips
- The 3-meter cable length provides flexibility for sensor placement. Utilize this to position the sensor optimally on your battery bank for the most accurate readings.
- For systems with multiple batteries, place the sensor on the battery that best represents the average temperature of the entire bank.
10. Frequently Asked Questions (FAQ)
- Q: What is the length of the sensor cable?
- A: The EPever RTS300R47K3.81A TS-R Remote Temperature Sensor cable is 3 meters long.
- Q: Is this sensor compatible with my EPever solar charge controller?
- A: This sensor is compatible with a wide range of EPever/EPsolar controllers, including Tracer-AN, XTRA, Triron, VS-BN, VS-AU, LS-B, DuoRacer, MSC-N, Tracer-BN, UPower, UPower-Hi, and GoMate series. Always refer to your specific controller's manual for confirmation.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your original point of purchase or the official EPever customer service. Keep your purchase receipt as proof of purchase.
A detailed user manual in PDF format may be available for download from the manufacturer's website or through the provided link: User Manual (PDF). This document may contain additional detailed instructions and diagrams.