1. Introduction
This manual provides detailed instructions for the operation and installation of the YR-E20 Wired Controller LCD panel, designed for use with York DUCT TYPE INDOOR UNIT Central Air-Conditioning systems. Please read this manual thoroughly before installation and operation to ensure correct usage and optimal performance.
Important Compatibility Note: This controller is a functional replacement for the models listed. While the specific model number on the unit may differ from your original, it is guaranteed to be compatible. Due to continuous manufacturer updates, minor variations in button layout may occur between production batches, but functionality remains consistent.

Figure 1: YR-E20 Wired Controller with its Operation & Installation Manual.
2. Package Contents
Upon opening the package, verify that all items are present and undamaged:
- YR-E20 Wired Controller LCD Panel
- Operation & Installation Manual (this document)
- Mounting Screws
- Wire Nuts
Note: The connecting cable for the controller needs to be purchased separately, as its required length may vary depending on your installation. Batteries are not included with this product.

Figure 2: YR-E20 Wired Controller, manual, and installation accessories.
3. Specifications
| Feature | Detail |
|---|---|
| Model Number | 0150401567A (YR-E20) |
| Use | Air Conditioner, Universal (DUCT TYPE INDOOR UNIT Central Air-Conditioning) |
| Wireless Communication | IR (Infrared) |
| Frequency | 433 MHz |
| Channel | 1 |
| Support APP | No |
| Package | Yes |
| Origin | Mainland China |
| Certification | NONE |
| Color | White |
| Battery Type | Without included |
| Condition | New |
| Product Dimensions (approx.) | Length: 18cm, Width: 10cm, Height: 4cm |
| Product Weight (approx.) | 0.1 kg |
4. Installation and Setup
This section outlines the steps for installing and setting up your YR-E20 Wired Controller. Professional installation is recommended for electrical components.
4.1 Mounting the Controller
- Choose a suitable location on an interior wall, away from direct sunlight, drafts, or heat sources, which could affect temperature readings.
- Carefully open the controller casing. The rear of the unit typically has a "PRESS TO OPEN" indicator (see Figure 3).
- Secure the back plate of the controller to the wall using the provided mounting screws. Ensure it is level.

Figure 3: Rear view of the YR-E20 Wired Controller, indicating mounting points and opening mechanism.
4.2 Wiring Connection
WARNING: Ensure power to the air conditioning unit is turned OFF at the circuit breaker before performing any wiring connections to prevent electrical shock.
- Route the connecting cable (purchased separately) from your central air-conditioning unit to the controller's mounting location.
- Connect the wires from the air conditioning unit to the appropriate terminals on the controller's circuit board. Refer to the wiring diagram provided with your specific air conditioning unit for correct terminal identification.
- Use the provided wire nuts to secure any necessary wire connections.
- Once wiring is complete, carefully reattach the front panel of the controller to its back plate.

Figure 4: Internal circuit board of the YR-E20 Wired Controller, showing connection points. Consult your AC unit's manual for specific wiring diagrams.
After installation, restore power to the air conditioning unit. The controller should power on and display information on its LCD screen.
5. Operating Instructions
The YR-E20 Wired Controller features an intuitive LCD touch panel for easy control of your central air-conditioning system.

Figure 5: Front view of the YR-E20 Wired Controller LCD panel with touch buttons.
5.1 Button Functions (Inferred from image)
- Power/Mode Button (Leftmost icon): Typically used to turn the unit ON/OFF or cycle through operating modes (e.g., Cool, Heat, Fan, Dry, Auto).
- Up/Down Arrows (Triangle icons): Used to adjust temperature settings, fan speed, or navigate menu options.
- Fan Speed/Swing Button (Fan icon): Adjusts fan speed or activates/deactivates swing function.
- Timer/Clock Button (Clock icon): Sets timers for automatic operation or adjusts the current time.
- Function/Settings Button (Grid icon): Accesses advanced settings or additional functions.
Specific icons and their exact functions may vary slightly. Refer to the on-screen prompts or your air conditioning unit's manual for detailed mode descriptions.
5.2 Basic Operation
- Power On/Off: Press the Power/Mode button to turn the unit on or off.
- Select Mode: Repeatedly press the Power/Mode button to cycle through available operating modes until your desired mode is displayed.
- Adjust Temperature: Use the Up/Down arrow buttons to set your desired room temperature.
- Adjust Fan Speed: Press the Fan Speed/Swing button to cycle through fan speed options (e.g., Low, Medium, High, Auto).
6. Maintenance
The YR-E20 Wired Controller requires minimal maintenance to ensure long-term performance.
- Cleaning: Wipe the LCD panel and casing with a soft, dry, or slightly damp cloth. Do not use abrasive cleaners, solvents, or chemical sprays, as these can damage the surface and internal components.
- Avoid Obstructions: Ensure the controller is not obstructed by furniture, curtains, or other objects that could block its sensors or interfere with its operation.
- Environmental Conditions: Keep the controller in a stable environment, avoiding extreme temperatures or high humidity.
7. Troubleshooting
If you encounter issues with your YR-E20 Wired Controller, try the following steps before contacting support:
- Controller Not Responding:
- Check if the air conditioning unit has power.
- Ensure the wiring connections are secure and correct (refer to Section 4.2).
- Temporarily disconnect and reconnect power to the air conditioning unit (at the circuit breaker) to reset the controller.
- Incorrect Temperature Readings:
- Verify that the controller is not exposed to direct sunlight, drafts, or heat sources.
- Ensure proper air circulation around the controller.
- Buttons Not Responding:
- Clean the touch panel surface to remove any dirt or residue.
- Perform a power cycle (turn off and on the AC unit's power).
If problems persist after attempting these troubleshooting steps, please contact customer support.
8. User Tips
Based on common user experiences, here are some tips for getting the most out of your controller:
- Cable Length: When purchasing the connecting cable, measure the exact distance required to avoid excess slack or tension.
- Gentle Touch: The LCD panel is touch-sensitive; a light touch is sufficient for button activation.
- Consult AC Manual: For advanced functions or specific error codes, always refer to the operation manual of your York central air-conditioning unit.
9. Warranty and Support
This product comes with a 3-month warranty from the date of purchase. This warranty covers manufacturing defects and malfunctions under normal use.
For any questions regarding product compatibility, technical support, or warranty claims, please contact the seller or manufacturer directly. When contacting support, please provide your model number (YR-E20 or 0150401567A) and a detailed description of the issue.