York 0150401567A

York Central Air-Conditioning Wired Controller

Model: 0150401567A

User Manual

1. Introduction

This manual provides instructions for the installation, operation, and maintenance of the York Wired Controller, model 0150401567A, designed for central air-conditioning systems. This controller allows precise management of your air conditioning unit's functions, including temperature setting, operating mode, and fan speed.

Note: Due to shipping considerations, the physical instruction manual and original packaging box are typically not included with the product. Please refer to this digital manual for all necessary information.

2. Package Contents

Upon receiving your product, please ensure all items are present:

  • 1 x York Wired Controller (Model: 0150401567A)

Screws for installation may be requested separately if needed.

3. Specifications

Feature Specification
Model Number 0150401567A (1567A)
Use Air Conditioner
Wireless Communication Wire Control
Support APP No
Channel 1
Frequency 433 MHz (Note: Primary communication is wired)
Origin Mainland China
Certification None
Product Length 18 cm
Product Width 13 cm
Product Height 2 cm
Product Weight 0.2 kg

4. Installation and Setup

Installation should ideally be performed by a qualified technician. Always ensure power is disconnected before beginning installation.

  1. Disconnect Power: Turn off the power to your central air-conditioning unit at the main circuit breaker.
  2. Open Controller Back Panel: Locate the "PRESS TO OPEN" area on the back of the controller. Gently press and separate the front display unit from the back mounting plate.
  3. Mounting Plate Installation: Secure the back mounting plate to a suitable wall location using appropriate screws. Ensure it is level and stable.
  4. Wiring Connections: Connect the control wires from your air-conditioning unit to the terminal block on the back mounting plate. Refer to the specific wiring diagram provided with your York central air-conditioning unit for correct pin assignments and voltage requirements. Incorrect wiring can damage the controller or the AC unit.
  5. Reassemble Controller: Carefully align the front display unit with the mounted back plate and press them together until they securely click into place.
  6. Restore Power: Turn the power back on at the main circuit breaker. The controller display should illuminate.
Close-up of the back of the York wired controller, highlighting the wiring terminal block and the 'PRESS TO OPEN' mechanism for installation. The model number 0150401567A is visible.
Figure 1: Back view of the controller showing the wiring terminal area and 'PRESS TO OPEN' mechanism.

5. Operating Instructions

The York Wired Controller features an intuitive interface for managing your air conditioning system. The main display shows the current temperature and operating status, while buttons allow for function adjustments.

Open manual page showing display functions and the back of the controller. The manual illustrates ON/OFF, temperature setting, fan speed, mode selection, and other functions.
Figure 2: Controller display and function overview from the manual.

Basic Functions:

  • ON/OFF Button: Press to power the air conditioning unit on or off.
  • MODE Button: Cycles through available operating modes. Common modes include:
    • Cool (Snowflake icon): For cooling the room.
    • Heat (Sun icon): For heating the room.
    • Auto (A icon): Automatically selects cooling or heating based on set temperature.
    • Dry (Water drop icon): For dehumidification.
    • Fan (Fan icon): Operates the fan without heating or cooling.
  • UP/DOWN Arrows (▲ / ▼): Adjust the desired temperature setpoint.
  • FAN Button: Cycles through fan speed settings (e.g., Low, Medium, High, Auto).
  • FUNCTION Button: Accesses additional features such as Timer settings, Sleep mode, or Key Lock, depending on the specific model's capabilities. Refer to the display icons for guidance.

Display Indicators:

The digital display provides visual feedback on the system's status:

  • Temperature: Shows the current room temperature or the set temperature.
  • Mode Icon: Indicates the active operating mode (Cool, Heat, Auto, Dry, Fan).
  • Fan Speed Icon: Displays the selected fan speed.
  • Timer Icon: Appears when a timer function is active.
  • Lock Icon: Indicates that the keypad is locked to prevent accidental changes.
  • Other Icons: May include indicators for Sleep mode, defrost, or other system statuses.

6. Maintenance

To ensure optimal performance and longevity of your York Wired Controller, follow these simple maintenance guidelines:

  • Cleaning: Gently wipe the controller's surface with a soft, dry cloth. Do not use abrasive cleaners, solvents, or spray liquids directly onto the unit.
  • Avoid Obstructions: Ensure that the controller's sensors (if any) are not blocked by furniture, curtains, or other objects, as this can affect temperature readings.
  • Environmental Conditions: Keep the controller away from direct sunlight, heat sources, and areas with high humidity to prevent damage.

7. Troubleshooting

If you encounter issues with your controller, try the following basic troubleshooting steps:

  • No Display/No Power:
    • Check if the main power to your air conditioning unit is on.
    • Verify that the controller is securely attached to its mounting plate and all wiring connections are firm.
  • Incorrect Temperature Reading:
    • Ensure the controller is not exposed to direct sunlight or drafts from windows/doors.
    • Make sure there are no heat-emitting appliances near the controller.
  • Unit Not Responding to Commands:
    • Check if the keypad lock function is active (look for a lock icon on the display). If so, unlock it according to the operating instructions.
    • Cycle the power to the air conditioning unit at the circuit breaker, wait a few minutes, and then restore power.

If problems persist after attempting these steps, it is recommended to contact a qualified HVAC technician for further assistance.

8. User Tips

  • Wiring Diagrams and Voltage: For specific wiring pinouts, connector details (e.g., number of pins), and operating voltage requirements, always refer to the installation manual provided with your specific York central air-conditioning unit. These details are crucial for safe and correct installation and operation.
  • Accessing Wiring Terminals: The controller's back panel is designed to be easily opened by pressing the indicated area to access the wiring terminals during installation or servicing.

9. Warranty and Support

For information regarding product warranty, technical support, or service, please contact the original seller or a certified York service provider. Keep your purchase records for any warranty claims.

Related Documents - 0150401567A

Preview York PG3 Series 460V 3-Phase Packaged Air Conditioner Technical Guide
This technical guide provides comprehensive information on the York PG3 Series packaged air conditioners with gas heat, featuring 13.4 SEER2 efficiency and R-454B refrigerant. It details specifications, features, installation considerations, and performance data for models designed for commercial and light commercial applications.
Preview YORK YK-EP Energy Plus Centrifugal Liquid Chillers: Engineering Guide
Comprehensive engineering guide for YORK YK-EP Energy Plus Centrifugal Liquid Chillers, detailing features, specifications, sustainability, application data, and operational guidance for efficient HVAC solutions.
Preview York Air Handler User Manual: Operation, Maintenance, and Warranty
Comprehensive user manual for York residential split air handlers, covering operation, system functions, maintenance, troubleshooting, and limited warranty information. Includes guidance on thermostat settings, filter care, and efficiency tips.
Preview York Affinity Series Central Dehumidifiers: Whole-Home Humidity Control & Air Quality
Discover the York Affinity Series Central Dehumidifiers, designed to enhance your home's indoor air quality by effectively managing humidity. Learn how these units provide whole-home comfort, protect against mold and allergens, prevent structural damage, and offer energy savings. Features include easy maintenance and a 5-year warranty. Explore sizing guidelines and installation options.
Preview YORK LX Series YC3 13.4 SEER2 Split-System Air Conditioner Technical Guide
This technical guide provides detailed specifications, installation procedures, performance data, and accessory information for YORK LX Series YC3 13.4 SEER2 single-phase split-system air conditioners.
Preview York Retail System Specific Wiring Diagrams
This document provides detailed wiring diagrams for York Retail Systems, specifically focusing on installations using Honeywell thermostats. It covers various York air handler, furnace, and heat pump models, offering essential technical information for installers and technicians.