MiLESEEY TR10, TR160i, TR256i

MILESEEY TR Series Infrared Thermal Camera User Manual

Models: TR10, TR160i, TR256i

Brand: MiLESEEY

1. Introduction

The MILESEEY TR Series Infrared Thermal Cameras (TR10, TR160i, TR256i) are advanced thermal imaging devices designed for accurate temperature measurement and efficient anomaly detection across various applications. These cameras provide clear thermal images, enabling users to easily identify hot spots, cold spots, and other temperature-related issues in industrial, electrical, building, and HVAC inspections. This manual provides essential information for the safe and effective operation of your thermal camera.

Video: Overview of MILESEEY TR Series Thermal Imager features and applications.

2. Safety Information

  • Do not point the camera directly at the sun or other high-intensity energy sources. This can damage the detector.
  • Avoid exposing the device to extreme temperatures, humidity, or corrosive environments.
  • Do not attempt to open or modify the device. Refer all servicing to qualified personnel.
  • Keep the device away from water and other liquids.
  • Use only the specified charging accessories.

3. Package Contents

Please check the package contents upon receipt. If any items are missing or damaged, contact your vendor.

  • MILESEEY TR Series Thermal Camera (TR10 or TR256i)
  • USB-C Charging/Data Cable
  • User Manual (this document)

4. Product Overview

4.1 TR10 Handheld Thermal Camera

TR10 Handheld Thermal Camera (Front and Back View)

Image: TR10 Handheld Thermal Camera (Front and Back View)

The TR10 is a handheld thermal camera featuring a robust design with a built-in display, intuitive buttons, and a trigger for capturing images. It is designed for ease of use in various inspection scenarios.

4.2 TR256i Compact Thermal Imager

TR256i Compact Thermal Imager (Full Metal Body)

Image: TR256i Compact Thermal Imager (Full Metal Body)

The TR256i is a compact, full-metal body thermal imager designed to connect to Android phones and tablets via its USB-C connector. It leverages your smart device's screen for thermal imaging display and control.

5. Setup

5.1 Initial Charging (TR10)

Before first use, fully charge your TR10 thermal camera using the provided USB-C cable and a compatible charger. The device features a 3000mAh battery, providing up to 8 hours of continuous operation on a full charge.

5.2 Powering On/Off (TR10)

  • To power on: Press and hold the red power button until the screen illuminates.
  • To power off: Press and hold the red power button until the device shuts down.

5.3 Connecting to Smart Devices (TR256i)

  • Download the MILESEEY Thermal App: Access your device's browser and navigate to the official MILESEEY website or follow instructions provided with the TR256i to download the dedicated thermal imaging application.
  • Connect the TR256i: Plug the TR256i directly into the USB-C port of your Android phone or tablet.
  • Launch the App: Open the MILESEEY Thermal App. The app should automatically detect the connected imager and display the thermal feed.
TR256i Compatibility with Android Phones and Tablets

Image: TR256i works with Android phones and tablets via the MILESEEY Thermal App.

6. Operating Instructions

6.1 Basic Temperature Measurement

Point the thermal camera at the object or area you wish to inspect. The screen will display a thermal image, with different colors representing different temperatures. The device automatically locks and displays the maximum, minimum, and center-point temperatures within the scanned area.

TR10 Accurate Temperature Measurement Display

Image: TR10 displaying accurate temperature measurements with hot/cold spot indicators.

6.2 Auto Hot & Cold Spot Tracking

The TR series cameras feature automatic tracking of the hottest (High Point) and coldest (Low Point) temperatures within the field of view, enhancing efficiency in identifying anomalies.

TR10 Auto Hot & Cold Spot Tracking Display

Image: TR10 showing auto hot and cold spot tracking with High/Low Temperature Alarm.

6.3 High/Low Temperature Alarm

Set custom high and low temperature thresholds. The device will alert users to areas exceeding or falling below these preset temperatures, highlighting potential issues such as overheating components or structural abnormalities.

6.4 Saving Images (TR10)

To save a thermal image, pull the trigger on the TR10 handheld camera. The image will be stored in the internal 8GB memory, which can hold over 30,000 pictures.

TR10 USB-C Connection for Picture Transfer

Image: TR10 connected via USB-C for real-time picture transfer to a PC.

6.5 Color Palettes

Both TR10 and TR256i offer multiple color palettes to visualize thermal data. You can select the ideal color scale for your specific inspection needs. Common palettes include White Hot, Black Hot, Iron, Rainbow, and Red Hot.

TR256i Multiple Color Palettes on Mobile App

Image: TR256i displaying multiple color palettes through the mobile application.

6.6 Adjustable Emissivity

The TR series cameras allow you to adjust emissivity settings. This is crucial for accurate temperature readings as different materials emit infrared energy differently. Consult an emissivity table for common materials and adjust the setting in the camera's menu (TR10) or app (TR256i) accordingly.

7. Maintenance

  • Cleaning the Lens: Gently wipe the lens with a soft, lint-free cloth. For stubborn dirt, use a lens cleaning solution designed for optics. Do not use abrasive materials or harsh chemicals.
  • Cleaning the Device Body: Use a soft, damp cloth to clean the exterior of the camera. Avoid getting moisture into any openings.
  • Storage: Store the camera in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, ensure the battery is partially charged (around 50%) to prolong its lifespan.
  • Battery Care (TR10): Avoid fully discharging the battery frequently. Recharge the battery regularly, even if the camera is not in use, to maintain battery health.

8. Troubleshooting

  • Device not powering on (TR10): Ensure the battery is charged. Connect the camera to a power source and try again.
  • No thermal image (TR256i): Check if the TR256i is securely connected to your Android device's USB-C port. Ensure the MILESEEY Thermal App is installed and running. Verify that your phone/tablet supports USB OTG (On-The-Go) functionality.
  • Inaccurate temperature readings: Verify that the emissivity setting is correctly adjusted for the material being measured. Ensure the measurement distance is appropriate (e.g., for TR10, optimal distance is around 0.6m).
  • Image appears blurry or distorted: Clean the camera lens. Ensure the object is within the camera's focus range.
  • Device unresponsive: For TR10, try a soft reset by holding the power button for an extended period (e.g., 10-15 seconds) until it restarts. For TR256i, restart the app or reconnect the device.

9. Specifications

FeatureTR10TR256i
Brand NameMiLESEEY
ModelTR10, TR160iTR256i
StyleHandheldCompact (Phone Attachment)
Thermal Pixels / Resolution240 x 240256 x 192
Frame Rate25 Hz
Thermal Sensitivity (NETD)<50mk
Minimum Temperature-15 °C (-4°F)-15 °C
Maximum Temperature550 °C (1022°F)600 °C
Accuracy±2°CUp to ±2°C
Display Size2.8 Inches LCDUses connected smart device display
Battery IncludedYes (3.7V 3000mAh)No (Powered by smart device)
Power TypeCharger (USB-C)USB-C (from smart device)
Storage Capacity8GB (30,000 pictures)Uses connected smart device storage
Drop Test6.6ftN/A (Compact, full metal body)
Hign-concerned ChemicalNone
Is Smart DeviceNoNo (Connects to smart devices)
OriginMainland China

10. User Tips

  • Building Inspections: The TR series cameras are highly effective for checking private homes for heat loss, identifying insulation gaps, and detecting moisture issues.
  • Optimal Measurement Distance: For the TR10, an optimal measurement distance of approximately 0.6 meters (2 feet) is recommended for the most accurate readings. While the camera can detect temperatures at greater distances, precision may decrease.
  • Emissivity Settings: Always adjust the emissivity setting based on the material you are inspecting. Incorrect emissivity is a common cause of inaccurate temperature readings.
  • TR256i App: Ensure your Android device's operating system is up-to-date for optimal performance with the MILESEEY Thermal App.

11. Warranty and Support

MILESEEY products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please refer to the official MILESEEY website or contact your local distributor. Keep your proof of purchase for warranty claims.

Related Documents - TR10, TR160i, TR256i

Preview MILESEEY TR256i Mobile Phone Infrared Thermal Imager User Guide
User guide for the MILESEEY TR256i, a portable mobile phone infrared thermal imager. Learn about its features, functions, and operation for professional thermal imaging analysis.
Preview MILESEEY TR256i/TR1601 Mobile Phone Infrared Thermal Imager User Guide
Comprehensive user guide for the MILESEEY TR256i and TR1601 mobile phone infrared thermal imagers, detailing product overview, features, app functions, specifications, and precautions.
Preview Manual de Usuario MILESEEY TR10: Cámara Térmica Infrarroja Portátil
Guía completa para el uso y configuración de la cámara térmica infrarroja portátil MILESEEY TR10. Aprenda sobre sus características, instrucciones de seguridad y ajustes para mediciones precisas de temperatura.
Preview MiLESEEY TR10 Handheld Infrared Thermal Imager User Manual
Comprehensive user manual for the MiLESEEY TR10 Handheld Infrared Thermal Imager. Includes setup instructions, safety guidelines, and operational features for accurate temperature measurement.
Preview TR10 User Manual: Mileseey Handheld Infrared Thermal Imager Guide
Comprehensive user manual for the Mileseey TR10 handheld infrared thermal imager. Details features, operation, safety, and maintenance for accurate thermal inspections.
Preview MILESEEY TR10 Handheld Infrared Thermal Imager User Manual
User manual for the MILESEEY TR10 Handheld Infrared Thermal Imager, detailing its features, safety instructions, and operational settings for accurate temperature measurement.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.