1. Introduction
Thank you for choosing the EPEVER iTracer-ND series MPPT solar charge controller. This series is designed with multiphase synchronous rectification technology (MSRT) and a common negative design, featuring a dual-core processor architecture and an advanced MPPT control algorithm. These products offer high response speed, reliability, and adherence to industrial standards.
The MPPT control algorithm ensures fast and accurate tracking of the maximum power point (MPP) of your PV array, maximizing solar energy harvest. MSRT guarantees high conversion efficiency across various charge power levels, significantly improving the solar system's energy efficiency. With a Modbus communication protocol interface, the controller facilitates expanded applications and monitoring in diverse settings such as telecommunication base stations, household systems, and wilderness monitoring. Comprehensive electronic fault self-test functions and enhanced electronic protection features are integrated to prevent damage from installation errors or system failures.

2. Safety Information
Please read all instructions and warnings in this manual carefully before installation and operation. Keep this manual for future reference.
- Ensure all wiring is correctly polarized and securely connected to prevent damage.
- Always connect the battery first, then the solar panel, and finally the load. Disconnect in the reverse order.
- Do not exceed the maximum PV open circuit voltage or maximum input power ratings.
- Install the controller in a well-ventilated area, away from flammable materials and direct sunlight.
- Ensure proper grounding as specified.
- Only qualified personnel should perform installation and maintenance.
3. Product Features
- Advanced Maximum Power Point Tracking (MPPT) technology with efficiency no less than 99.5%.
- High quality components ensuring system performance, with maximum conversion efficiency of 98% and full load efficiency of 97%.
- Multiphase Synchronous Rectification Technology (MSRT) for high conversion efficiency even at low charge power.
- Ultra-fast tracking speed and guaranteed tracking efficiency.
- Accurate recognition and tracking of multiple power points.
- Reliable automatic limit function for maximum PV input power, preventing overload.
- Wide MPP operating voltage range.
- High-speed and high-powered dual-core processor architecture for improved system response and optimized performance.
- Die-cast aluminum case for excellent heat dissipation.
- Automatic identification of 12/24/36/48VDC system voltage or user-defined working voltage.
- Concise human-computer interactive interface with convenient multiple combination keys, dynamically displaying system operating data and working conditions.
- Multiple load control modes: manual control, light ON/OFF, light on + timer, and time control.
- Supports 4 charging options: Sealed, Gel, Flooded, and User-defined battery types.
- Battery temperature compensation function.
- Real-time energy statistics function.
- RS-485 and RS-232 communication bus interfaces with Modbus protocol for various communication requirements.
- Available for PC monitoring and external display unit connection (e.g., MT50) for real-time data checking and parameter setting.
- Supports software upgrades.



4. Specifications
4.1. Electrical Parameters
| Parameter | IT4415ND | IT6415ND |
|---|---|---|
| Nominal System Voltage | 12/24/36/48VDC | |
| Nominal Battery Current | 45A | 60A |
| Battery Input Voltage Range | 8V-68V | |
| Max. PV Open Circuit Voltage | 150V (at minimum operating environment temperature) 138V (at 25°C environment temperature)① | |
| MPP Voltage Range | Battery voltage + 2V ~ 108V | |
| Maximum Input Power | 600W/12V; 1200W/24V; 1800W/36V; 2400W/48V | 800W/12V; 1600W/24V; 2400W/36V; 3200W/48V |
| Self Consumption | 1.4W-2.6W | |
| Discharge Circuit Voltage Drop | <0.3V | |
| Grounding | Common Negative | |
4.2. Environmental Parameters
| Parameter | Value |
|---|---|
| LCD Temperature Range | -20°C ~ +70°C |
| Ambient Temperature Range② | -25°C ~ +55°C |
| Storage Temperature Range | -30°C ~ +85°C |
| Humidity Range | ≤95%, N.C. |
| Enclosure | IP20 |
| Altitude | < 5000 m (Derating to operate according to IEC60146 at a height exceeding 1000 m) |
①Max. PV open circuit voltage must never exceed 138V under 25℃ conditions.
②Please operate controller at permitted ambient temperature. If over permissible range, please derate capacity in service.
4.3. Physical Dimensions and Weight
| Parameter | IT4415ND | IT6415ND |
|---|---|---|
| Dimension (L*W*H) | 382*231*107mm | 440*231*110mm |
| Mounting Hole | Φ10 | |
| Terminal Size | 2AWG (35mm2) | |
| Weight | 4.6kg | 5.9kg |

5. Installation and Wiring
Proper installation is crucial for the safe and efficient operation of your solar charge controller. Follow these steps carefully:
- Mounting: Choose a suitable location for mounting the controller. It should be indoors, protected from direct sunlight, high temperatures, and water. Ensure adequate airflow around the controller for heat dissipation. Use the mounting holes (Φ10) and appropriate fasteners to secure the controller to a vertical surface.
- Wiring Order: Always connect components in the following order: Battery → Solar Panel → Load. Disconnect in the reverse order.
- Battery Connection: Connect the battery to the BATT+ and BATT- terminals. Ensure correct polarity. The controller will automatically detect the system voltage.
- Solar Panel Connection: Connect the solar panel array to the PV+ and PV- terminals. Ensure correct polarity and that the PV open circuit voltage does not exceed the controller's maximum rating.
- Load Connection: Connect the DC load to the LOAD+ and LOAD- terminals. Ensure correct polarity.
- Grounding: Ensure the controller is properly grounded according to local electrical codes. The iTracer series features common negative grounding.

Note: Use appropriate cable sizes (Terminal size: 2AWG / 35mm2) for all connections to minimize voltage drop and ensure safety.
6. Operation
Once installed, the controller will automatically begin operation. The LCD screen provides real-time system data, and the buttons allow for parameter configuration.
6.1. Display and Navigation
The LCD screen displays various operating parameters such as battery voltage, PV voltage, charging current, load current, and energy statistics. Use the navigation buttons (ESC, UP, DOWN, OK) to browse through menus and adjust settings.
6.2. Battery Type Selection
The controller supports Sealed, Gel, Flooded, and User-defined battery types. It is critical to select the correct battery type in the settings to ensure optimal charging and prolong battery life. Refer to the battery manufacturer's specifications for recommended charging parameters if using the 'User' option.
6.3. Load Control Modes
The controller offers multiple load control modes:
- Manual Control: Turn the load ON or OFF manually via the controller interface.
- Light ON/OFF: The load turns ON at dusk and OFF at dawn.
- Light ON + Timer: The load turns ON at dusk and stays ON for a set duration (e.g., 4 hours), then turns OFF.
- Time Control: The load operates during specific programmed time periods.
6.4. Communication and Monitoring
The controller features RS-485 and RS-232 communication ports, supporting the Modbus protocol. This allows for connection to a PC for detailed monitoring and parameter configuration using EPEVER's software, or to external display units like the MT50.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your solar charge controller.
- Visual Inspection: Periodically check for any loose connections, damaged wiring, or signs of corrosion.
- Cleaning: Keep the controller's casing and heat sink fins clean and free from dust and debris to ensure efficient heat dissipation. Use a dry cloth for cleaning.
- Ventilation: Ensure that the installation area remains well-ventilated and free from obstructions that could impede airflow.
- Firmware Updates: Check the manufacturer's website for any available firmware updates to ensure your controller has the latest features and bug fixes.
8. Troubleshooting
If you encounter issues with your iTracer controller, consider the following common troubleshooting steps:
- No Display/Power: Check battery connections and voltage. Ensure the battery is charged above the minimum operating voltage.
- No Charging: Verify solar panel connections and ensure there is sufficient sunlight. Check PV open circuit voltage and current. Ensure the battery type is correctly set.
- Load Not Working: Check load connections and ensure the load control mode is correctly configured. Verify that the battery voltage is above the low voltage disconnect (LVD) setting.
- Overheating: Ensure adequate ventilation around the controller. Clean any dust or debris from the heat sink. Reduce the load or PV input if consistently overheating.
- Communication Issues: Verify RS-485/RS-232 cable connections. Ensure correct baud rate and protocol settings in monitoring software.
For persistent issues, consult the full product manual (if available) or contact EPEVER technical support.
9. User Tips
- System Sizing: Always ensure your solar panel array and battery bank are appropriately sized for your energy needs and compatible with the controller's specifications.
- Battery Health: Regularly monitor your battery's state of charge and health. Proper battery maintenance is key to system longevity.
- Monitoring: Utilize the communication features (PC software or external display) to gain deeper insights into your system's performance and optimize settings.
- Environmental Considerations: While robust, protecting the controller from extreme temperatures, humidity, and direct weather exposure will extend its lifespan.
10. Accessories: eBox-WIFI-01 Serial Server
The eBox-WIFI-01 is an optional serial server designed to provide Wi-Fi communication functionality for EPEVER solar controllers and inverters. It enables wireless monitoring, parameter settings, and other functions via a mobile phone application.
10.1. Features of eBox-WIFI-01
- Enables wireless monitoring of solar controller and inverter.
- Supports mobile phone APP for plug-and-play setup, simple and convenient.
- Utilizes a high-performance CPU with an M4 core.
- Offers ultra-low power consumption and high-speed data processing capability.
- Does not require an external power supply (powered directly by the RS485 port).
- Communication distance up to 50m.
- One-key restore to factory settings.


10.2. Technical Specifications of eBox-WIFI-01
| Item | eBox-WIFI-01 |
|---|---|
| Input Voltage | 5VDC (Direct powered by RS485 port) |
| Standby Power Consumption | 0.20W |
| Operation Power Consumption | 0.25W |
| Communication Distance | ≤50m |
| Port Baud Rate | 300bps~230400bps (Default 115200) |
| Communication | RS485 to WIFI |
| Interface Type | RJ45 |
| Connecting Cable | Standard network cable (Parallel cable) |
| Overall Dimension | 51*67*24.5mm |
| Mounting Dimension | 41.2mm |
| Mounting Hole Size | Φ3.2mm |
| Working Temperature | -35~75℃ |
| Enclosure | IP30 |
| Net Weight | 39g |
11. Warranty and Support
The EPEVER iTracer MPPT Solar Charge Controller comes with a 3-year warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use and service.
For technical support, warranty claims, or service inquiries, please contact your authorized EPEVER dealer or visit the official EPEVER website for contact information.