1. Introduction
The UNI-T UTI120S Thermal Imaging Camera is a robust and cost-effective infrared imager designed for a wide range of applications, including construction, electrical system inspection, and mechanical equipment testing. It provides a clear thermal view of temperature distribution, helping to identify anomalies and potential issues.
Key features include:
- Infrared resolution: 120x90 pixels
- Temperature measurement range: -20℃ to 400℃
- 2.4-inch TFT display with 320x240 resolution
- Adjustable emissivity (0.01-0.99)
- Six selectable color palettes
- Built-in laser pointer and LED lighting
- USB image quick export and PC software analysis
- Durable design with IP54 dustproof and waterproof rating, and 2m drop resistance

2. Setup
2.1 Package Contents
Before using the device, ensure all items are present:
- UNI-T UTI120S Thermal Imaging Camera
- USB Type-C Cable
- User Manual (this document)
- Protective Pouch (may be included as a gift)
2.2 Charging the Battery
The UTI120S is equipped with a built-in 3.7V 2600mAH rechargeable lithium battery. Before first use, fully charge the device.
- Connect the provided USB Type-C cable to the camera's USB port.
- Connect the other end of the USB cable to a standard USB power adapter (not included) or a computer's USB port.
- The charging indicator on the device will show the charging status. Ensure the device is fully charged for optimal performance.
2.3 Inserting/Removing TF Card
The device supports a TF card for photo storage (16GB TF card is typically included). The TF card slot is located on the side of the device.
- To insert: Gently push the TF card into the slot until it clicks into place.
- To remove: Gently push the TF card again; it will spring out slightly, allowing you to pull it out.

3. Operating Instructions
3.1 Power On/Off
- To power on: Press and hold the power button (
) until the screen illuminates. - To power off: Press and hold the power button until the device shuts down.
3.2 Basic Operation
The device features a 2.4-inch TFT display and intuitive buttons for navigation:
- OK Button: Confirms selections or captures images.
- Up/Down Buttons: Navigate through menus or adjust settings.
- Power Button: Powers the device on/off.

3.3 Thermal Imaging Modes
The UTI120S offers various display modes, including thermal, digital camera, thermal blending, and Picture-in-Picture (PiP) on selected models. It automatically tracks hot and cold spots and displays the central point temperature.
3.4 Color Palettes
The device offers six color palettes to visualize temperature differences. You can select the most suitable palette for your application to enhance contrast and detail.

3.5 Laser Pointer and LED Lighting
- Laser Pointer: Use the built-in laser pointer to precisely identify the target area for temperature measurement.
- LED Lighting: The integrated LED light helps illuminate dim scenes, allowing for better visual inspection alongside thermal imaging.


3.6 Image Export and Analysis
Saved thermal images can be easily exported to a computer for further analysis using the provided USB Type-C cable and PC software.

3.7 Applications
The UTI120S is suitable for a wide range of applications, including:
- Pipeline inspection
- Power system inspection
- Window tightness testing
- Motor inspection
- Power distribution cabinet inspection
- Air conditioning air outlet detection

4. Maintenance
4.1 Cleaning
- Wipe the device body with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- For the lens, use a specialized lens cleaning cloth and solution to avoid scratching.
4.2 Storage
- Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.
- If storing for an extended period, ensure the battery is partially charged (around 50%) and recharge it every few months to maintain battery health.
4.3 Battery Care
- Avoid fully discharging the battery frequently.
- Do not expose the battery to high temperatures.
- If the battery shows signs of damage or swelling, discontinue use immediately and contact support.
5. Troubleshooting
5.1 Device Not Turning On
- Ensure the battery is sufficiently charged. Connect the device to a charger and wait for a few minutes before attempting to power on again.
- If the device still does not turn on, try a different USB cable and power source.
5.2 Unclear or Distorted Thermal Images
- Check if the lens is clean. Dust or smudges can affect image quality.
- Ensure the target object is within the optimal measurement distance (e.g., best measuring distance is 50cm).
- Verify that the emissivity setting is appropriate for the material being inspected.
5.3 Inaccurate Temperature Readings
- Confirm the emissivity setting matches the material of the object being measured. Different materials have different emissivities.
- Ensure there are no obstructions or reflective surfaces between the camera and the target.
- Allow the camera to stabilize to the ambient temperature if it has been moved from a significantly different environment.
6. Specifications
| Feature | Specification |
|---|---|
| Sensor | Uncooled infrared focal plane thermal imaging sensor |
| Infrared Resolution | 120x90 pixels (10800 pixels) |
| Pixel Size | 17μm |
| Temperature Range | -20℃ to 400℃ |
| Temperature Measurement Accuracy | ±2℃ or ±2% (whichever is larger) |
| Temperature Measurement Response Time | ≤500ms |
| Emissivity | Adjustable (0.01-0.99), default 0.95 |
| Field of View (FOV) | 50°(H)*38°(V) |
| Thermal Imaging Sensitivity | ≤60mK |
| Frame Rate | ≤25Hz |
| Temperature Measurement Display | Central point temperature, high and low temperature tracking |
| Image Format | BMP |
| Temperature Alarm | Image alarm, LED alarm, buzzer alarm |
| Laser Pointer | Yes |
| PC Analysis Software | Yes |
| Data Communication | Type-C USB |
| Display Type | 2.4" TFT LCD |
| Display Resolution | 320*240 |
| Battery | Li-ion 3.7V/2600mAH 18650 single cell |
| Automatic Shut-down | Optional (5min, 10min, 30min off) default 30min |
| Charging Voltage/Current | 5V/2A |
| Image Storage | TF card |
| Drop Requirement | 2 meters |
| IP Rating | IP54 |


7. User Tips
- Detecting Water Leaks and Floor Heating Pipes: While the UTI120S is not a direct water leak detector, it excels at identifying temperature anomalies. Water leaks or active floor heating pipes will create distinct temperature patterns on surfaces. By observing these thermal differences, you can infer the presence and location of such elements. Look for colder spots where water might be seeping or warmer lines indicating heating pipes beneath the surface.
- Emissivity Adjustment: For the most accurate temperature readings, always adjust the emissivity setting to match the material you are inspecting. Highly reflective surfaces (like polished metals) have low emissivity, while matte, non-metallic surfaces have high emissivity. Refer to common emissivity tables for guidance.
- Optimal Distance: For precise measurements, maintain an optimal distance from the target, typically around 50cm, as indicated in the specifications.
8. Warranty and Support
8.1 Warranty Information
This product typically carries a 12-month warranty from the date of purchase. Please retain your proof of purchase for warranty claims. The warranty covers manufacturing defects and malfunctions under normal use. It does not cover damage caused by misuse, accidents, unauthorized modifications, or improper maintenance.
8.2 Customer Support
For technical assistance, troubleshooting, or warranty inquiries, please contact the seller or UNI-T customer support. Provide your product model (UTI120S) and a detailed description of the issue to facilitate a quicker resolution.