A-OK AC125-01/AC126-01

A-OK AC125-01/AC126-01 Wireless Wall Switch Instruction Manual

Model: AC125-01 / AC126-01 | Brand: A-OK

1. Introduction

This manual provides instructions for the A-OK AC125-01 and AC126-01 RF433 Wireless Wall Switches. These switches are designed to wirelessly control A-OK RF433 compatible curtain motors and tubular motors. The AC125-01 is a single-channel switch for one motor, while the AC126-01 is a dual-channel switch capable of controlling two motors separately.

A-OK AC125-01 and AC126-01 Wireless Wall Switches
Figure 1: A-OK AC125-01 (left) and AC126-01 (right) Wireless Wall Switches.

2. Product Overview

The A-OK wireless wall switches offer a modern and convenient way to control your motorized curtains or blinds without complex wiring. They feature a sleek design with a scratch-resistant acrylic panel and moisture-proof treatment, ensuring durability and aesthetic appeal.

2.1 Models

  • AC125-01: Single Controller Sticker Switch. Designed to control one RF433 motor.
  • AC126-01: Dual Controller Sticker Switch. Designed to control two RF433 motors separately.
A-OK AC125-01 Single Controller Sticker Switch
Figure 2: A-OK AC125-01 Single Controller.
A-OK AC126-01 Dual Controller Sticker Switch
Figure 3: A-OK AC126-01 Dual Controller.

3. Specifications

FeatureSpecification
Model NumbersA-OK AC125-01 / AC126-01
FrequencyRF433.92MHz
Battery Type27A 12V (not included)
Working Temperature-20°C to +55°C
Transmitting Power≤10mW
Dimensions (L x W x H)86mm x 86mm x 10.5mm
Installation Hole Spacing60mm
CertificationCE
OriginMainland China
CompatibilityA-OK RF433 curtain/tubular motors
Specifications table for A-OK AC125-01 and AC126-01
Figure 4: Detailed product specifications.
Dimensions and installation points of the A-OK wall switch
Figure 5: Physical dimensions and installation hole spacing.

4. Setup

4.1 Battery Installation

  1. Gently pry open the front panel of the switch to reveal the battery compartment.
  2. Insert one 27A 12V battery into the designated slot, ensuring correct polarity (+/-). Note: Battery is not included in the package.
  3. Snap the front panel back into place.
Battery installation for A-OK wall switch
Figure 6: Battery compartment showing 27A 12V battery slot.

4.2 Mounting the Switch

The switch can be easily fixed to a wall using the pre-applied 3M double-sided adhesive or by screwing it into place using the installation positioning holes.

  1. Adhesive Mounting: Peel off the protective film from the 3M adhesive pads on the back of the switch. Press firmly onto a clean, dry, flat wall surface.
  2. Screw Mounting: Use appropriate screws (not included) through the designated installation positioning holes (60mm apart) to secure the switch to the wall.
Back of A-OK wall switch with 3M adhesive
Figure 7: Rear view of the switch showing 3M adhesive pads and screw holes.

4.3 Pairing with A-OK RF433 Motor

To control your curtain or tubular motor, the wall switch must be paired with the motor. The specific pairing procedure is typically detailed in the instruction manual provided with your A-OK RF433 motor. Please refer to your motor's manual for precise pairing steps. Generally, this involves putting the motor into a pairing mode and then pressing a button on the wall switch.

A-OK wall switch compatible with curtain motor systems
Figure 8: The wall switch integrates with A-OK RF433 curtain motor systems.

5. Operation

Once paired, the wall switch provides intuitive control over your motorized curtains or blinds.

5.1 Button Functions (AC125-01 Single Controller)

A-OK AC125-01 button functions: Open, Pause, Close
Figure 9: AC125-01 button layout and functions.
  • Up Arrow Button: Press to open the curtain/blind.
  • Middle Bar Button: Press to pause the curtain/blind movement.
  • Down Arrow Button: Press to close the curtain/blind.

5.2 Button Functions (AC126-01 Dual Controller)

The AC126-01 features two sets of control buttons, allowing independent control of two separate motors.

A-OK AC126-01 controlling two motors separately
Figure 10: AC126-01 dual control functionality.
  • Each column of buttons (Up Arrow, Middle Bar, Down Arrow) controls one motor.
  • Use the left column for Motor 1 and the right column for Motor 2 (after successful pairing).

5.3 Demonstration Video

Video 1: Demonstration of battery installation and basic button functionality.

6. Maintenance

6.1 Battery Replacement

When the switch's indicator light no longer illuminates or the motor response becomes inconsistent, it may be time to replace the battery. Follow the battery installation steps (Section 4.1) to replace the 27A 12V battery.

6.2 Cleaning

To clean the switch, gently wipe the acrylic panel with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the surface.

7. Troubleshooting

ProblemPossible CauseSolution
Switch not responding / Indicator light offDead or incorrectly installed battery.Check battery polarity and replace with a new 27A 12V battery if necessary.
Switch not controlling motorSwitch not paired with the motor, or pairing lost.Refer to your A-OK RF433 motor's instruction manual to re-pair the switch with the motor.
Motor responds intermittentlyLow battery or interference.Replace battery. Ensure no strong RF interference sources are nearby.

8. User Tips

  • Always ensure the correct battery type (27A 12V) is used for optimal performance.
  • Keep the switch within the recommended operating range of your A-OK RF433 motor for reliable control.
  • If you encounter issues with programming or pairing, consult the specific manual for your A-OK RF433 motor, as the pairing process can vary slightly between motor models.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your original retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Related Documents - AC125-01/AC126-01

Preview A-OK DC Tubular Motor: Features and Operation Guide
Learn about the features and operation of A-OK DC Tubular Motors, including installation, programming, and limit setting. This guide covers model AM35-6/18-ES-E-Z and AM45-20/12-R-ES-EZ.
Preview AC127 Remote Control User Manual and Specifications
Detailed user manual for the AC127 remote control, including features, parameters, installation instructions, operations, troubleshooting, and FCC/ISED compliance information.
Preview A-OK AM35 120VAC RF Motor Programming Instructions | AVOutlet.com
Detailed programming guide for A-OK AM35 120VAC mechanical limit RF motors. Covers remote pairing, limit setting, direction changes, and troubleshooting for automated shades.
Preview User Guide for A-OK Energy Saving Tuya Zigbee Motor
This user guide provides instructions and features for the A-OK Energy Saving Tuya Zigbee Motor, including installation, operation, programming, and troubleshooting. It covers features like built-in rechargeable battery, electronic limit setting, and APP intelligent control.
Preview AOK RF Motor Programming & AM25/AM28 User Manual | AVOutlet
Detailed instructions for programming AOK RF motors, including setup, limit setting, remote control pairing, and troubleshooting. Covers general RF motor programming and specific operations for the AOK AM25 and AM28 DC motors.
Preview AOK AM25/28 RF Motor Programming Instructions and User Guide
Comprehensive guide to programming AOK AM25/28 RF motors for motorized shades, including setup, limit setting, remote pairing, and troubleshooting. Features detailed steps for motor operation, limit adjustment, and remote management.