1. Introduction
The EPEVER MT75 is a next-generation remote meter designed for comprehensive monitoring of EPEVER solar charge controllers and inverters. It provides real-time system data on a single screen, offering versatile solutions for various off-grid power system requirements.

Figure 1: EPEVER MT75 Remote Meter
Key Features:
- Dual RJ45 communication ports for versatile connectivity.
- 4.7-inch LCD screen for dynamic, real-time display of system data.
- Visual error codes for timely notification of warnings and faults.
- Direct load ON/OFF button to control load output.
- Dry contact output and enable switch design.
- Remote control functionality for inverter ON/OFF.
- Seamless compatibility with various EPEVER devices.
2. Setup and Connection
The MT75 remote meter offers several application configurations to suit different system needs. Ensure all connections are secure and follow the diagrams carefully.
2.1 Standard Application
In this setup, the MT75 monitors the operational status and error codes of both the solar controller and the inverter. The load ON/OFF button directly controls the inverter's operation, helping to reduce inverter wear and extend system lifespan.

Figure 2: Standard Application Connection Diagram. This diagram illustrates the connection of a PV array to a solar controller, which charges a battery. A DC load is connected to the controller. An inverter is connected to the battery, and an AC load is connected to the inverter. The MT75 remote meter is connected to the solar controller via an RS485 cable. A relay interface is connected between the solar controller and the inverter, with its enable switch set to ON, and also connected to the MT75 via an RS485 cable.
2.2 Upgrade Application
Similar to the standard application, the MT75 monitors the solar controller and inverter. The load ON/OFF button controls the inverter's start or stop function. This configuration typically involves the relay interface enable switch being set to OFF, indicating a different control logic for the inverter.

Figure 3: Upgrade Application Connection Diagram. This diagram shows a similar setup to the standard application, but the relay interface enable switch is set to OFF. The MT75 is connected to the solar controller via an RS485 cable, and the relay interface is connected to the solar controller and the inverter, with its enable switch set to OFF.
2.3 Advanced Application
This application utilizes an RS485-1M2S module, allowing the MT75 to not only monitor the solar controller and inverter but also connect to external Wi-Fi, Bluetooth modules, or a PC. This enables parameter settings and operational status monitoring via a phone app or PC software. The MT75 can control both AC and DC loads with a single button in this setup.

Figure 4: Advanced Application Connection Diagram. This diagram shows a PV array, solar controller, battery, DC load, inverter, and AC load. An RS485-1M2S module is connected to the solar controller via an RS485 cable. The MT75 is connected to the RS485-1M2S module. The RS485-1M2S module also connects to eBox-BLE-01, eBox-WIFI-01, and a PC for extended monitoring and control. A relay interface is connected to the RS485-1M2S module and the inverter, with its enable switch set to ON.
2.4 Pro. Application
Similar to the Advanced Application, the Pro. Application also uses the RS485-1M2S module for extended connectivity to external Wi-Fi, Bluetooth, or PC for monitoring and parameter adjustments. In this configuration, the MT75 can remotely control the inverter's start or stop function, further extending the system's operational lifetime.

Figure 5: Pro Application Connection Diagram. This diagram is similar to the Advanced Application, showing the RS485-1M2S module connecting to the solar controller, MT75, and external communication modules. The key difference is the relay interface enable switch is set to OFF, allowing remote control of the inverter's start/stop function.
2.5 General Installation
The MT75 remote meter is designed for wall or surface mounting. Ensure the mounting location is dry, well-ventilated, and away from direct sunlight or extreme temperatures. Use appropriate fasteners for secure installation.
3. Operating Instructions
The MT75 remote meter provides an intuitive interface for monitoring and controlling your solar power system.
3.1 LCD Display
The 4.7-inch LCD screen dynamically displays various system parameters, including:
- PV array voltage and current
- Battery voltage and charge/discharge current
- Load status (ON/OFF) and current
- Inverter status
- Energy statistics (VAh, kWh)
- System warnings and error codes
- Clock and temperature (°C/°F)
3.2 Navigation and Control Buttons
The MT75 features several buttons for navigation and control:
- PV/+ Button: Used to navigate upwards or increase values.
- BATT/- Button: Used to navigate downwards or decrease values.
- LOAD/- Button: Used to navigate downwards or decrease values, and also to control the load output directly.
- Power Button: Used to turn the device ON/OFF or confirm selections.
- Load ON/OFF Button: Directly controls the connected load or inverter (depending on application setup).
Refer to the specific manual of your connected EPEVER solar controller or inverter for detailed menu navigation and parameter adjustment instructions via the MT75.
4. Maintenance
To ensure optimal performance and longevity of your MT75 remote meter, follow these maintenance guidelines:
- Cleaning: Regularly wipe the screen and casing with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the display or finish.
- Environmental Conditions: Ensure the device operates within its specified working temperature range (-20°C to +65°C) and is stored within its storage temperature range (-20°C to +80°C). Protect it from excessive dust, moisture, and direct sunlight.
- Cable Connections: Periodically check all RJ45 communication cables for secure connections and signs of wear or damage. Loose connections can lead to intermittent communication or data errors.
- Firmware Updates: If available, keep the firmware of your MT75 and connected EPEVER devices updated to benefit from performance improvements and new features.
5. Troubleshooting
This section provides general guidance for common issues. For specific error codes, consult the manual of your connected EPEVER solar charge controller or inverter.
Common Issues and Solutions:
- Display is blank or not turning on:
- Check the power supply to the connected solar controller or inverter.
- Ensure the RJ45 communication cable is securely connected to both the MT75 and the main device.
- Verify the backlight setting; it might be turned off or set to a very low brightness.
- No data displayed or incorrect readings:
- Confirm that the MT75 is properly connected to the solar controller via the RJ45 port.
- Check the integrity of the RJ45 cable for any damage.
- Ensure the connected solar controller and inverter are powered on and functioning correctly.
- Load ON/OFF button not responding:
- Verify the connection to the relay interface (if used) and ensure its enable switch is set correctly for your application.
- Check the settings on the main solar controller or inverter to ensure remote control is enabled.
- Error codes displayed:
- Note down the specific error code.
- Refer to the user manual of your EPEVER solar charge controller or inverter for detailed explanations and troubleshooting steps related to that code.
6. Technical Specifications
The following table outlines the technical specifications for the EPEVER MT75 remote meter:

Figure 6: Technical Specifications
| Item | MT75 |
|---|---|
| Compatible products | Controller: XTRA-N series/TRIRON series/Tracer-AN series/Tracer-BN series (Required cables shipped with MT75). iTracer-AD series/iTracer-ND series (Required cables need additional purchase). Inverter: IPower series (1kW or above, suitable for application), IPower-Plus series/NPower series/SHI series. |
| Voltage supply | 5VDC |
| Power supply methods | Solar controller communication port, Inverter communication port |
| LCD visual angle | 12' clock |
| LCD backlight | Yes |
| Installation methods | Wall/surface mounting installation |
| Self-consumption | 14mA/5V (no backlight), 26mA/5V (backlight) |
| Working temperature | -20°C ~ +65°C |
| Storage temperature | -20°C ~ +80°C |
| Dimension | 193x94.6x48mm (base), 193x85.2x23mm (no base) |
| Mounting size | 175x50mm (base), 176mm (no base) |
| Mounting hole size | φ5mm (base), φ4.3mm (no base) |
| Net Weight | 0.29Kg (base), 0.22Kg (no base) |
7. User Tips
- Compatibility Check: Always ensure your solar charge controller and inverter are compatible with the MT75 remote meter. The MT75 is designed for EPEVER XTRA-N, TRIRON, Tracer-AN, Tracer-BN series controllers and IPower/IPower-Plus/NPower/SHI series inverters.
- Inverter Control: Utilize the remote ON/OFF feature for your inverter via the MT75. This can help manage power consumption and potentially extend the lifespan of your inverter by reducing unnecessary operation.
- Advanced Monitoring: For enhanced monitoring capabilities, consider integrating the RS485-1M2S module. This allows connection to external Wi-Fi or Bluetooth modules, enabling system monitoring and parameter adjustments through a smartphone app or PC software.
- Cable Management: Use high-quality RJ45 communication cables and ensure they are properly routed and secured to prevent accidental disconnections or damage.
8. Warranty and Support
For detailed information regarding the product warranty, please refer to the official warranty policy provided by EPEVER or your authorized dealer. This policy outlines the terms, conditions, and duration of the warranty coverage.
Should you encounter any technical issues or require assistance with your EPEVER MT75 remote meter, please contact EPEVER customer support or your local distributor. Have your product model and any relevant error codes ready to facilitate a quicker resolution.