1. Introduction
Thank you for selecting the VS AU series common positive solar charge controller. The VS AU controller is a PWM charge controller with a built-in LCD display that adopts the most advanced digital technique. Its multiple load control modes enable it to be widely used in solar home systems, traffic signals, solar street lights, solar garden lamps, and other applications.
2. Product Features and Components
The EPever VS AU series controller offers robust performance and user-friendly features:
- Adopts high-quality components from ST, IR, and Infineon, ensuring a long product lifespan.
- Terminals are UL and VDE certified, enhancing product safety and reliability.
- Controller can operate continuously at full load within an environment temperature range from -25 to 55 ℃.
- Features 3-Stage intelligent PWM charging: Bulk, Boost/Equalize, Float.
- Supports 3 charging options: Sealed, Gel, and Flooded batteries.
- LCD display design dynamically shows device operating data and working conditions.
- Double USB design provides power supply for electronic equipment.
- Humanized button settings make operation comfortable and convenient.
- Multiple load control modes.
- Energy statistics function.
- Battery temperature compensation function.
- Extensive electronic protection.
Controller Components

| No. | Component | No. | Component |
|---|---|---|---|
| ① | LCD | ⑤ | Battery Terminals |
| ② | MENU Button | ⑥ | Load Terminals |
| ③ | RTS Port | ⑦ | SET Button |
| ④ | PV Terminals | ⑧ | USB Output Ports |
3. Installation and Wiring
Proper installation and wiring are crucial for the safe and efficient operation of your solar charge controller. Follow these steps carefully:

- Connect components to the charge controller in the sequence shown in the diagram. Pay close attention to the “+” and “-” polarities.
- Important: Do not insert the fuse or turn on the breaker during the installation process.
- When disconnecting the system, reverse the order of connection.
- After powering on the controller, check if the LCD display is on. If not, refer to the troubleshooting section.
- Always connect the battery first to allow the controller to recognize the system voltage.
- The battery fuse should be installed as close to the battery as possible, with a suggested distance of within 150mm.
- The VS AU series is a positive ground controller. Any positive connection of solar, load, or battery can be earth grounded as required.
4. Operating Instructions
The EPever VS AU series controller is designed for intuitive operation. Here are key aspects of its functionality:
Charging Process
The controller utilizes a 3-stage intelligent PWM charging algorithm to optimize battery health and longevity:
- Bulk Charge: This is the initial stage where the battery is charged at its maximum current until its voltage rises to the Boost voltage.
- Boost/Equalize Charge: After reaching the Boost voltage, the controller maintains this voltage for a set period to ensure a full charge. An Equalize charge, if enabled, provides a higher voltage for a short duration to balance cell voltages in flooded batteries.
- Float Charge: Once the battery is fully charged, the controller reduces the voltage to a float level, maintaining the battery at full capacity and preventing overcharging.
The controller supports Sealed, Gel, and Flooded battery types. Ensure the correct battery type is selected in the settings for optimal charging.
LCD Display and Button Functions
The integrated LCD display provides real-time information about the system's operating status. Use the MENU and SET buttons to navigate through display screens and adjust parameters:
- MENU Button: Typically used to cycle through different display screens (e.g., battery voltage, PV voltage, load current, temperature, energy statistics).
- SET Button: Used to enter parameter setting mode, confirm selections, or adjust values.
Refer to the on-screen prompts for specific navigation and setting adjustments.
Load Control Modes
The controller offers various load control modes to manage the connected DC loads, such as street lights or other appliances. These modes can include:
- Manual Control: Turn the load on or off manually.
- Light Control: Load turns on at dusk and off at dawn.
- Light Control + Timer: Load turns on at dusk and stays on for a set number of hours.
- Dual-Timer Control: Allows for two separate timer periods for load operation.
Consult the display and button settings to configure your desired load control mode.
USB Output
The dual USB ports provide 5VDC/2.4A (total) output for charging small electronic devices like phones and tablets.
5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your solar charge controller and overall solar system.
- Visual Inspection: Periodically check the controller for any signs of physical damage, corrosion, or loose connections. Ensure all wiring is secure.
- Cleanliness: Keep the controller clean and free from dust, dirt, and debris. Use a dry, soft cloth for cleaning. Do not use liquids or abrasive cleaners.
- Ventilation: Ensure that the controller's ventilation openings are not obstructed to prevent overheating.
- Terminal Check: Annually, check all terminal connections for tightness. Loose connections can cause resistance, heat buildup, and potential damage.
- Battery Health: Monitor your battery's condition. For flooded batteries, check electrolyte levels and top up with distilled water if necessary.
- Environmental Conditions: Ensure the controller is installed in a dry, well-ventilated area, protected from direct sunlight, rain, and extreme temperatures, within its specified operating range (-25℃ to +55℃).
6. Troubleshooting
If you encounter issues with your EPever VS AU series solar charge controller, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Controller LCD is off / No power | Battery not connected or reverse polarity; Battery voltage too low; Loose battery connection. | Check battery connections and polarity. Ensure battery voltage is above the minimum operating threshold. Tighten all battery terminal connections. |
| Battery not charging | PV panels not connected or reverse polarity; PV voltage too low; Loose PV connection; PV input short-circuited; Controller fault. | Check PV connections and polarity. Ensure PV voltage is sufficient (above battery voltage). Tighten PV terminal connections. Inspect PV wiring for shorts. If problem persists, contact support. |
| Load not working | Load not connected or reverse polarity; Load current exceeds rating; Load short-circuited; Battery voltage too low (LVD); Load control mode setting. | Check load connections and polarity. Ensure load current is within controller limits. Inspect load wiring for shorts. Check battery voltage; if below LVD, charge battery. Verify load control mode settings. |
| USB output not working | USB device not compatible; USB port overloaded; Controller fault. | Try a different USB device. Ensure total USB current draw does not exceed 2.4A. If problem persists, contact support. |
| Inaccurate voltage/current readings | Loose connections; Faulty sensor; Controller fault. | Check and tighten all wiring connections. If equipped with an external temperature sensor (RTS), ensure it is properly connected. If problem persists, contact support. |
For issues not covered here or if troubleshooting steps do not resolve the problem, please contact customer support.
7. Technical Specifications
The following table details the technical specifications for the VS AU series solar charge controllers, with specific focus on the VS1024AU model:
| Item | VS1024AU | VS2024AU | VS3024AU | VS3048AU | VS4524AU | VS4548AU | VS6024AU | VS6048AU |
|---|---|---|---|---|---|---|---|---|
| Nominal system voltage | 12/24VDC Auto | 12/24/36/48VDC Auto | 12/24VDC Auto | 12/24/36/48VDC Auto | 12/24VDC Auto | 12/24/36/48VDC Auto | ||
| Battery input voltage range | 9V~32V | 9V~64V | 9V~32V | 9V~64V | 9V~32V | 9V~64V | ||
| Rated charge/discharge current | 10A@55℃ | 20A@55℃ | 30A@55℃ | 45A@55℃ | 60A@55℃ | |||
| Max. PV open circuit voltage | 50V | 96V | 50V | 96V | 50V | 96V | ||
| Battery type | Sealed(Default) / Gel / Flooded | |||||||
| Equalize Charging Voltage※ | Sealed:14.6V/ Gel: No/ Flooded:14.8V | |||||||
| Boost Charging Voltage※ | Sealed:14.4V/ Gel:14.2V/ Flooded:14.6V | |||||||
| Float Charging Voltage※ | Sealed/Gel/Flooded:13.8V | |||||||
| Low Voltage Reconnect Voltage※ | Sealed/Gel/Flooded:12.6V | |||||||
| Low Voltage Disconnect Voltage※ | Sealed/Gel/Flooded:11.1V | |||||||
| Self-consumption | ≤9.2mA/12V;≤11.7mA/24V; ≤14.5mA/36V;≤17mA/48V | |||||||
| Temperature compensation coefficient | -3mV/℃/2V(25℃) | |||||||
| Charge circuit voltage drop | ≤0.29V | |||||||
| Discharge circuit voltage drop | ≤0.16V | |||||||
| LCD temperature range | -20℃~+70℃ | |||||||
| Working environment temperature | -25℃~+55℃(Product can work continuously at full load) | |||||||
| Relative humidity | ≤95%, N.C. | |||||||
| Enclosure | IP30 | |||||||
| Grounding | Common Positive | |||||||
| USB output | 5VDC/2.4A(Total) | |||||||
| Overall dimension | 142x85x41.5mm | 160x94.9x49.3mm | 181x100.9x59.8mm | 194x118.4x63.8mm | 214x128.7x72.2mm | |||
| Mounting dimension | 130x60mm | 148x70mm | 172x80mm | 185x90mm | 205x100mm | |||
| Mounting hole size | Φ4.5mm | Φ5mm | Φ5mm | Φ5mm | ||||
| Terminals | 4mm2/12AWG | 10mm2/8AWG | 16mm2/6AWG | 16mm2/6AWG | 25mm2/4AWG | |||
| Net weight | 0.22kg | 0.35kg | 0.55kg | 0.58kg | 0.76kg | 0.88kg | 1.02kg | 1.04kg |
| ※Above the parameters are in 12V system at 25℃, twice in 24V system, triple in 36V system and quadruple in 48V system. | ||||||||
Note: This manual specifically refers to the 12V/24V PV50V models, such as the VS1024AU.
8. User Tips
This section would typically include helpful tips and insights gathered from user experiences and frequently asked questions. As no specific user reviews or Q&A were provided, general advice for solar charge controller users is offered:
- Battery Type Selection: Always ensure the correct battery type (Sealed, Gel, or Flooded) is selected in the controller settings to prevent damage and ensure efficient charging.
- System Sizing: Ensure your solar panel array and battery bank are appropriately sized for your load requirements and the controller's capacity. An undersized system may not meet your energy needs, while an oversized one could lead to inefficiencies.
- Cable Sizing: Use appropriately sized cables for all connections (PV to controller, controller to battery, controller to load) to minimize voltage drop and maximize efficiency. Refer to the specifications for recommended terminal sizes.
- Environmental Protection: While the controller has an IP30 enclosure, protecting it from direct moisture, excessive dust, and extreme temperatures will extend its lifespan.
- Monitoring: Regularly check the LCD display for system status, battery voltage, and charging current to ensure everything is operating as expected.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt and product model number handy when seeking support.
The manufacturer is committed to providing high-quality products and customer satisfaction. Should you encounter any issues or require assistance, do not hesitate to reach out to the authorized support channels.