1. Overview
IPower Plus is a new series of pure sine wave inverters compatible with lithium battery systems. This inverter features input surge current suppression technology, which effectively prevents damage to lithium battery cells and Battery Management Systems (BMS) from surge currents. Its smart voltage and current double closed-loop control algorithm provide faster response and better resistance to load impact. The inverter uses high-quality, high-power density components to ensure stable, reliable, and sufficient power output for long-term use. Optional communication solutions allow for real-time operational status monitoring and parameter changes from any location.
This equipment is suitable for various DC to AC applications, including solar AC power systems, vehicle systems, RV power supplies, security monitoring systems, emergency lighting systems, field power systems, and household power systems. The inverter also possesses EMC (Electro Magnetic Compatibility) characteristics, making it suitable for applications requiring higher power quality.

Figure 1: EPEVER IPower Plus Inverter (IP1500-12-Plus) front view.
2. Key Features
- The input and output adopt completely isolated design.
- Smart voltage and current double closed-loop control bring a faster response and better reliability.
- EMC characteristic which widely applied to higher quality requirement power system.
- Adoption of advanced SPWM technology and pure sine wave output.
- Input surge current suppression technology to support the lithium battery system.
- Resistance to load impact supports impact loads (e.g., Air conditioner, Washing machine, Refrigerator, etc.).
- High power density and high-quality components to ensure reliability.
- Output power factor up to 1.
- Low loss of no-load and standby.
- Low THD (Total Harmonic Distortion).
- High conversion efficiency.
- Extensive protection: input reverse polarity, input overvoltage, input low voltage, output overload, and short circuit, overheating.
- Air cooling control by dual condition (Temperature and Load).
- 180-degree rotatable LCD design to simplify the system wiring.
- One-click control of operational status.
- Friendly LCD design to simply monitor and parameter configuration.
- Supports phone Apps and PC software remote control.
- Output voltage 220/230VAC and frequency 50/60Hz optional.
- USB ports (5VDC/Max. 1A) to power DC fans, and other electronic equipment or charge phones. (Note: USB function unavailable for 48V input inverters).
- External switch contact design to allow remote control.
- IEC62109, EN61000, RoHS approved.
3. Setup and Installation
Before installation, ensure the inverter is placed in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure sufficient clearance around the unit for proper airflow.
3.1 Component Identification

Figure 2: Inverter Component Identification (IP3000-12-Plus shown as example, similar layout for IP1500-12-Plus).
- DC input terminal positive (+)
- DC input terminal negative (-)
- Ventilation fan
- LCD
- AC output terminal
- RS485 communication port
- USB output port 5VDC/Max. 1A
- External switch connection point
- Inverter switch
- Grounding terminal
Note:
- The USB output port is not available for 48V input systems.
- Ensure all connections are secure and correctly polarized.
3.2 Wiring Diagram
A detailed wiring diagram is crucial for safe and correct installation. Please refer to the following diagram for connecting the inverter to your DC power source and AC loads.

Figure 3: Typical wiring diagram for EPEVER IPower Plus Inverter.
Important Safety Precautions:
- Always disconnect the DC power source before making or breaking any connections.
- Ensure proper grounding of the inverter.
- Use appropriate wire gauges for DC input and AC output connections to prevent overheating.
- Install fuses or circuit breakers on the DC input side as recommended by local electrical codes.
4. Operation
4.1 LCD Display and Buttons
The inverter features an LCD display and buttons for monitoring and configuration. The LCD can be rotated 180 degrees for convenience.

Figure 4: LCD Display and Button Functions.
- LCD: Displays operational status and parameters.
- UP/Setting button: Used to navigate menus and adjust settings.
- Fault indicator (red): Illuminates to indicate a fault condition.
- Working status indicator (Blue):
- Blue ON solid: Inverter is operating normally.
- Blue slowly flashing (1/4Hz): Standby mode.
- Blue fast flashing (1Hz): Warning condition.
- Blue OFF: Inverter is off or no power.
- DOWN/Enter button: Used to navigate menus, confirm settings, and toggle output ON/OFF.
4.2 Starting and Stopping the Inverter
- Starting: Ensure all connections are secure. Turn on the DC power source. Press and hold the DOWN/Enter button (5) for a few seconds until the inverter powers on and the working status indicator (4) turns solid blue.
- Stopping: Press and hold the DOWN/Enter button (5) for a few seconds until the inverter powers off and the working status indicator (4) turns off. Disconnect the DC power source.
4.3 Monitoring and Configuration
Parameters can be monitored via the inverter LCD, remote LCD (if connected), phone Apps, and PC software. Refer to the specific software manual for detailed instructions on remote monitoring and configuration.
5. Maintenance
Regular maintenance ensures optimal performance and longevity of your EPEVER IPower Plus Inverter.
- Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris.
- Fan Operation: The cooling fan operates based on temperature and load.
- The fan will automatically turn on if:
- Heat sink temperature is higher than 50°C.
- Internal temperature is higher than 50°C.
- Output power is higher than 50% of the rated power.
- The fan will automatically turn off if:
- Heat sink temperature is lower than 40°C.
- Internal temperature is lower than 40°C.
- Output power is lower than 40% of the rated power.
- The fan will automatically turn on if:
- Connection Checks: Regularly inspect all DC and AC connections for tightness and corrosion. Tighten any loose connections.
- Environment: Ensure the inverter remains in a well-ventilated, dry environment, free from excessive dust or corrosive gases.
6. Troubleshooting
This section provides guidance on common issues. For more complex problems, contact customer support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter does not turn on. | No DC input power; DC input reverse polarity; Low DC input voltage. | Check DC power source and connections; Verify correct polarity; Ensure DC input voltage is within specified range. |
| No AC output. | Inverter off; Overload; Short circuit; Overheating. | Turn on inverter; Reduce load; Check for short circuits in AC wiring; Allow inverter to cool down. |
| Fault indicator (red) is on. | Internal fault; Overvoltage/Undervoltage; Overload; Short circuit; Overheating. | Check LCD for specific error code; Address the underlying issue (e.g., reduce load, check voltage); If fault persists, contact support. |
| Blue working status indicator is fast flashing (1Hz). | Warning condition (e.g., input voltage near limits, high temperature). | Check input voltage and ambient temperature; Ensure proper ventilation. |
7. Technical Specifications
The following table details the technical specifications for the IPower Plus series, including the IP1500-12-Plus model.

Figure 5: Technical Specifications for IPower Plus Series Inverters.
| Item | IP1500-12-Plus(T) | IP2000-12-Plus(T) | IP2000-22-Plus(T) | IP2000-42-Plus(T) | IP3000-12-Plus(T) |
|---|---|---|---|---|---|
| Output continuous power | 1500W@35℃ @ Rated input voltage | 2000W@35℃ @ Rated input voltage | 2000W@35℃ @ Rated input voltage | 2000W@35℃ @ Rated input voltage | 3000W@35℃ @ Rated input voltage |
| Surge power | 3000W@5S | 4000W@5S | 4000W@5S | 4000W@5S | 6000W@5S |
| Output voltage | 220VAC(±3%); 230VAC(-7%~+3%) | 220VAC(±3%); 230VAC(-7%~+3%) | 220VAC(±3%); 230VAC(-7%~+3%) | 220VAC(±3%); 230VAC(-7%~+3%) | 220VAC(±3%); 230VAC(-7%~+3%) |
| Output frequency | 50/60Hz±0.2% | 50/60Hz±0.2% | 50/60Hz±0.2% | 50/60Hz±0.2% | 50/60Hz±0.2% |
| Output wave | Pure Sine Wave | ||||
| Output distortion THD | THD≤3% (Resistive load) | ||||
| Load power factor | 0.2~1 (VAsContinuous output power) | ||||
| Rated input voltage | 12VDC | 12VDC | 24VDC | 48VDC | 12VDC |
| Input voltage range | 10.8~16VDC | 10.8~16VDC | 21.6~32VDC | 43.2~64VDC | 10.8~16VDC |
| Max. efficiency① | >93% (30% load) | >94% (30% load) | >93% (30% load) | >94.5% (30% load) | >94% (30% load) |
| Self-consumption No-load current | <1.4A@12V | <1.2A | <1.0A | <0.5A | <1.6A |
| RS485 com. port | 5VDC/200mA | ||||
| Overall dimension (L*W*H) | 387×231.5×123mm | 421×213.5×123mm | 557×231.5×123mm | ||
| Weight | 8kg | 6.5kg | 6.5kg | 6.5kg | 10.5kg |
| Working Temperature | −20℃ ~ +50℃ (Refer to the Reduced capacity curve) | ||||
| Humidity | ≤95% (N.C.) | ||||
| Enclosure | IP20 | ||||
① When the DC input voltage is equal to system rated voltage, and connected with 30% power of load, the max conversion efficiency is 93%.
8. User Tips
- For optimal performance, ensure your battery bank is adequately sized for your inverter's power output and your expected load.
- Regularly check the inverter's LCD for any warning or fault indicators to address potential issues proactively.
- When connecting sensitive electronics, always ensure the inverter is providing a stable pure sine wave output.
- Utilize the remote monitoring features (phone app or PC software) to keep track of the inverter's status and adjust settings as needed, especially in off-grid or remote installations.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your authorized EPEVER dealer or visit the official EPEVER website. Keep your purchase receipt and product serial number handy when contacting support.
The product is certified with CE, IEC62109, EN61000, and RoHS standards.