The SmartFusion Microcontroller Subsystem (MSS) provides one Ethernet MAC hard peripheral.
The actual behavior of the Ethernet MAC must be defined at the application level using the SmartFusion
MSS MAC Driver provided by Actel.
In this document, we describe how you can enable the MSS MAC instance and select whether the
Ethernet MAC interface is connected to dedicated MSS I/Os or the FPGA fabric.
For more details about the MSS MAC hard peripheral, please refer to the Actel SmartFusion
Microcontroller Subsystem User’s Guide.

Configuration Options

Enabling/Disabling the MAC Instance. On the MSS canvas, you need to enable (default) or disable the MAC instance based on whether it is being used into your current application. If disabled, the MAC instance is held in reset (lowest power state) after the Actel system boot code is executed.

Actel SmartFusion Microcontroller Subsystem -

Connectivity Options. When using the A2F200M3F device, the Ethernet MAC, when enabled, can only be connected to dedicated MSS I/Os. When using the A2F500M3G device, you can choose to connect the MAC peripheral to dedicated MSS I/Os or the FPGA fabric. In all cases, the MAC connectivity is automatically configured by the Actel system boot code. Note that MSS I/Os allocated to the MAC instance are available to connect to the FPGA fabric if the MAC instance is disabled. Refer to the MSS I/O Configuration document for more details. To use the MAC FPGA ports (if that option is selected), you need to manually promote to the top level the FABRIC group port present on the MSS MAC instance. You can then use the FABRIC MAC ports in the next level of hierarchy.

Actel SmartFusion Microcontroller Subsystem - Options

Ethernet MAC Clock Selection. If you enable the MAC peripheral on the MSS configurator canvas the MAC clock is automatically selected (read-only) in the Clock configurator. Using the MSS Clock configurator you need to select one of the following MAC clock sources.

  • The external 10/100 clock (MAC_CLK pin) on the SmartFusion device.
  • A clock generated in the MSS Clock Conditioning Circuit (MSS_CCC).

Port Description

Table 1: MSS I/O Connectivity Options

Port Name Port Group Direction PAD? Description
RXER PADs In Yes Receive error.
If RX_ER is asserted during Ethernet MAC reception, the frame is received and status of the frame is updated with RX_ER.
CRSDV PADs In Yes Carrier sense and receive data valid.
This signal must be asserted by the PHY when either a receive or transmit medium is non-idle. The PHY device should assert MAC_CRSDV when valid data is provided on the RXD signal.
MDIO PADs Inout Yes RMII management data input and output.
The state of the input signal can be checked by reading the CSR9.19 bit. The output signal is driven by the CSR9.18 bit.
RXD[1:0] PADs In Yes Receive data recovered and decoded by PHY.
The RXD[0] signal is the least significant bit.
TXEN PADs Out Yes Transmit enable.
When asserted, indicates valid data for the PHY on the TXD port.
MDC PADs Out Yes RMII management clock = 25 MHz.
This signal is driven by the CSR9.16 bit.
TXD[1:0] PADs Out Yes Transmit data.
The TXD[0] signal is the least significant bit.

Table 2: FPGA Fabric Connectivity Options

Port Name Port Group Direction PAD? Description
F2M_RXER FABRIC In No Receive error.
If RX_ER is asserted during Ethernet MAC reception, the frame is received and status of the frame is updated with RX_ER.
F2M_CRSDV FABRIC In No Carrier sense and receive data valid.
This signal must be asserted by the PHY when either a receive or transmit medium is non-idle. The PHY device should assert MAC_CRSDV when valid data is provided on the RXD signal.
F2M_MDI FABRIC In No RMII management data input.
The state of the input signal can be checked by reading the CSR9.19 bit
Port Name Port Group Direction PAD? Description
M2F_MDIO FABRIC Out No RMII management data output.
The output signal is driven by the CSR9.18 bit.
M2F_MDEN FABRIC Out No RMII management data output enable.
F2M_RXD[1:0] FABRIC In No Receive data recovered and decoded by PHY.
The RXD[0] signal is the least significant bit.
M2F_TXEN FABRIC Out No Transmit enable.
When asserted, indicates valid data for the PHY on the TXD port.
M2F_MDC FABRIC Out No RMII management clock = 25 MHz.
This signal is driven by the CSR9.16 bit.
M2F_TXD[1:0] FABRIC Out No Transmit data.
The TXD[0] signal is the least significant bit.

Notes:

  • PAD ports are automatically promoted to top throughout the design hierarchy.
  • Non-PAD ports must be promoted manually to the top level from the MSS configurator canvas to be available as the next level of hierarchy.

Actel is the leader in low-power and mixed-signal FPGAs and offers the most comprehensive portfolio of system and power management solutions. Power Matters. Learn more at 5H http://www.actel.com .

Actel - logo

Actel Corporation
2061 Stierlin Court
Mountain View, CA
94043-4655 USA
Phone 650.318.4200
Fax 650.318.4600
Actel Europe Ltd.
River Court, Meadows Business Park
Station Approach, Blackwater
Camberley Surrey GU17 9AB
United Kingdom
Phone +44 (0) 1276 609 300
Fax +44 (0) 1276 607 540
Actel Japan
EXOS Ebisu Building 4F
1-24-14 Ebisu Shibuya-ku
Tokyo 150, Japan
Phone +81.03.3445.7671
Fax +81.03.3445.7668
6H http://jp.actel.com 
Actel Hong Kong
Room 2107, China Resources Building
26 Harbour Road
Wanchai, Hong Kong
Phone +852 2185 6460
Fax +852 2185 6488
www.actel.com.cn 

© 2009 Actel Corporation. All rights reserved. Actel and the Actel logo are trademarks of Actel Corporation. All other brand or product names are the property of their respective owners.
5-02-00238-0

Doc Version 1.0

Documents / Resources

Actel SmartFusion Microcontroller Subsystem (MSS) [pdf] User Guide
SmartFusion Microcontroller Subsystem MSS, SmartFusion, Microcontroller Subsystem MSS, Subsystem MSS
Actel SmartFusion Microcontroller Subsystem (MSS) [pdf] User Guide
SmartFusion Microcontroller Subsystem MSS

References

Leave a comment

Your email address will not be published. Required fields are marked *