AcraDyne LIT MAN177 Gen IV Controller Modbus TCP - LogoGen IV Controller
Ethernet IP Instructions 

From the main menu, select Controller. AcraDyne LIT MAN177 Gen IV Controller Ethernet

Select IO.AcraDyne LIT MAN177 Gen IV Controller Ethernet - Fig

Following are the Ethernet IP optionsAcraDyne LIT MAN177 Gen IV Controller Ethernet - Fig 3

NOTE: It is recommended that the request packed interval is configured for 100 ms.

Controller Inputs Addressing

The controller’s assignable inputs are mapped to the client’s EtherNet/IP outputs. The EtherNet/IP outputs start at assembly instance 112 and use block sizes that can be located for 8, 16, or 32 bits. These values must match the assignments made on the controller. For most applications, it is helpful to create assignments with a size of INT16.  his example is configured for a block size of 4 with a 16-bit data type. Controller Outputs Addressing AcraDyne LIT MAN177 Gen IV Controller Ethernet - Fig 1

Controller Outputs Addressing

The controller’s assignable outputs are mapped to the client’s Ethernet/IP inputs. The Ethernet/IP inputs start at assembly instance 100 and use block sizes that can be llocated for 8, 16, or 32 bits. These values must match the assignments made on the controller. For most applications, it is helpful to create assignments with a size of INT16.  his example is configured for a block size of 4 with a 16-bit data type.AcraDyne LIT MAN177 Gen IV Controller Ethernet - Fig 2

 

Ethernet IP Inputs
These types of communication are useful for data communication between controller and PLCs. It is an effective, quick way for the data transfer of short data packages.AcraDyne LIT MAN177 Gen IV Controller Ethernet - Fig 4

Example of the Ethernet IP Input screen with five Inputs set up.AcraDyne LIT MAN177 Gen IV Controller Ethernet - Fig 5

Click on AcraDyne LIT MAN177 Gen IV Controller Modbus TCP - Fig 8 to change an
individual Element or return to Input
Configuration screen.
AcraDyne LIT MAN177 Gen IV Controller Modbus TCP - Fig 9 Will delete individual Elements.
Element Type: Choose from Byte,
Int16, Int32, or ASCII.
Element: Shows element # being configured
Bit (not shown): Enter Bit #.
Bits: # of bits the assignment will read.
Start at: Starting bit location.
Polarity (not shown): Select Normally Open (N.O.) or Normally Closed Outputs (N.C.).
Length (not shown, available in
ASCII ID function): Number of characters desired to send.
Torque (not shown, available in Click Wrench function): Torque value to be reported when using Click Wrench input. Value input is what will be sent from the controller
when Input Signal is received
from a Click Wrench. Value is NOT calculated by the controller rather it is solely what the Click Wrench is calibrated to by outside means.
Torque Units (not shown, available with Click Wrench function): Choose from Nm, Kgm, Kgcm, Ftlb, and Inlb.
Function: See the Gen IV Controller User Manual for more details. Select desired Input Function(s).
Click onAcraDyne LIT MAN177 Gen IV Controller Modbus TCP - Fig 10  it after appropriate selections are made.

These types of communication are useful for data communication between controllers and PLCs. It is an effective, quick way for the data transfer of short data packages.AcraDyne LIT MAN177 Gen IV Controller Ethernet - Fig 6

Example of the Ethernet IP Input screen with five Inputs set up.

AcraDyne LIT MAN177 Gen IV Controller Ethernet - Fig 7

Click on AcraDyne LIT MAN177 Gen IV Controller Modbus TCP - Fig 8 to change an
individual Element or return to Input
Configuration screen.
AcraDyne LIT MAN177 Gen IV Controller Modbus TCP - Fig 9 Will delete individual Elements.

Element Type: Choose from Byte, Int16, Int32, or ASCII.
Element: Shows element # being configured
Bit: Enter Bit #.
Bits (not shown): # of bits the assignment will read.
Start at: Starting bit location.
Polarity: Select Normally Open or Normally Closed Outputs.
Mode:

  • Normal: Output signal sent.
  • Timed Signal Sent: Time entered in seconds
  • Flash Signal Sent: Time entered in seconds

Function: See the Gen IV Controller User Manual for more details on assignable functions.
Click on AcraDyne LIT MAN177 Gen IV Controller Modbus TCP - Fig 10 it after appropriate selections are made.

AcraDyne LIT MAN177 Gen IV Controller Ethernet - logoCORPORATE HEADQUARTERS
10000 SE Pine Street
Portland, Oregon 97216
Phone: (503) 254–6600
Toll-Free: 1-800-852-1368 LIT
AIMCO CORPORATION DE MEXICO SA DE CV
Ave. Cristobal Colon 14529
Chihuahua, Chihuahua. 31125
Mexico
Phone: (01-614) 380-1010
LIT-MAN177_ETHERNETIP
07-07-22
©2022 AIMCO