  • Product Name: Cylindrical Lock Touchscreen and Push Button
  • Optional Accessories: Multi-Family Key Module, Door Position Sensor (DPS)
  • Dimensions: Various sizes as per installation requirements
  • Compatibility: Wood and Metal Doors
  • Battery: AA batteries
  • Model Number: 80-9150-0080-010
  • Expiry Date: 04/2024

Determine HandingACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (1)ACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (2)

Prepare DoorACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (3)

Prepare FrameACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (4)

Prepare Inside LockACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (5)

Install LatchboltACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (6)

Remove Battery CoverACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (7)

Install KeypadACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (8)ACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (9)

Install Inside SupportACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (10)

Attach Cables to the Inside LockACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (11)

Install Inside Lock
Thin door gaskets are sold separately. See Installation Options.

Installation Options
Install any spacers or DPS before securing the interior escutcheon to the door. Install the Multi-Family Key Module before installing batteries.ACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (13)ACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (14)

Test Inside Lever OperationACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (15)

Install Batteries and CoverACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (16)

Programming Instructions

ACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (17)ACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (18)

Creating a Master PIN Code
Creating a Master PIN Code must be performed upon installation or after resetting the lock to factory default. Programming and using the lock are not possible until this step has been successfully completed.ACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (19)

Creating User PIN Codes
A master PIN code must be created first. The Multi-Family Key module enables access with physical (cards and fobs) and mobile credentials ONLY. Creation and use of User PIN codes are disabled.ACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (20)

Creating User PIN Codes, continuedACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (21)

Locking and Unlocking Door with Registered Master or User PIN Code
The Multi-Family Key module enables access with physical (cards and fobs) and mobile credentials ONLY. Creation and use of User PIN codes are disabled. The master PIN code is only used for programming and configuring the lock with the ACCENTRA Multi-Family configuration app and will not unlock the door. When the lock is configured into the Multi-Family system, “#2” and “#6” will no longer be visible when in “Menu” mode.ACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (22)

Testing Outside Lever OperationACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (23)

Locking Door with Privacy ButtonACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (24)

When the hen door is in a Locked state (door closed) press the privacy button once to activate privacy mode. When the door is not in a Locked state, press the privacy button two times The first press puts the door in a Locked state, second time activates privacy mode.

Resetting Lock to Factory Default

ACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (25)

When the lock is reset to factory defaults, all PIN codes, including the Master PIN code, are deleted and all programming features are reset to the original default settings (see Factory Settings).

  1. Remove the inside lever with the supplied lever removal tool.
  2. Remove the battery cover with the supplied hex wrench and then remove all batteries.
  3. Remove the 10-32 x 3/4″ pan head screw from the center of the battery housing.
  4. Remove the interior escutcheon from the door to access the reset button on the back of the interior escutcheon. Cables should stay connected (See illustration above for the location of the reset button.)
  5. Reinstall three (3) AA batteries.
  6. Press the reset button for 3 seconds.
  7. While continuing to press the reset button, insert the remaining one (1) AA battery.
  8. Release the reset button and wait approximately 15 seconds, or until the lock announces “Factory Reset Complete.”
  9. Reassemble the interior escutcheon and lever.

Upon reset, Master PIN Code creation is the only option available and must be performed prior to any other programming of the lock.

Definitions

All Code Lockout Mode: This feature is enabled by the Master PIN code. When enabled, it restricts all user (except Master) PIN code access. When attempting to enter a code while the unit is in Lockout, there will be an audible lock response. The touchscreen keypad will display a RED locked padlock. (Main Menu selection #6)

Automatic Re-lock Time: After a successful unlock, the unit will re-lock automatically after 3 seconds or for a duration selected in Advanced Lock Settings. (Main Menu selection #3 then #1) Eco Mode: When enabled, Eco Mode puts the unit in low power mode extending the life of the battery.

Language Setting Mode: Choose English (1), Spanish (2), or French (3) for the lock’s voice prompts. (Main Menu selection #5)

Low Battery: When battery power is low, the Low Battery Warning indicator is a flashing red battery icon on the touchscreen keypad and the ACCENTRA logo will flash red on the push button keypad. If battery power is completely lost, use 9 9-volt battery override. To use a 9V battery override apply a 9V battery, in either direction, to terminals on the keypad for a backup power option. Activate the lock and enter your PIN code to unlock the door.

Master PIN Code: The Master PIN code is used for programming and feature settings. It must be created before programming the lock. The Master PIN code will also unlock/lock the lock except when configured to the Multi-Family system.

Network Module Setting: With the optional Multi-Family Key Module installed, this setting becomes available (Main Menu selection #0) and allows the lock to be configured into the ACCENTRA Multi-Family system.

One Touch Locking: When the unit is unlocked, activating the lock will lock the unit (during Automatic Re-lock duration or when Automatic Re-lock is disabled). When One-Touch Re-lock is not in use (disabled), any valid PIN code will re-lock the lock. (Main Menu selection #3 then #3)

Passage PIN Code: When used to unlock, the lock will remain unlocked/open. The lock cannot be locked/secured until the Passage code is entered again.

Privacy Button to Lock Door: Press this button will lock the door if the door is not locked.

Privacy Mode: With an optional Door Position Sensor installed, Privacy Mode enabled through Menu Mode and the door closed, all keypad functions can be disabled with a press of the Privacy Button. Privacy Mode is disabled by default. Enable Privacy Mode through Main Menu selection #3 then #4. With the door closed, press and hold the privacy button until the voice prompt indicates Privacy Mode enabled. Privacy Mode duration ends when the door is opened and the voice prompt indicates Privacy Mode is disabled.

Shut Down Time: The unit will shut down for sixty (60) seconds and not allow operation after the wrong code entry limit (5 attempts) has been met. When the unit is Shut down, the keypad will flash. Tamper Alert: An audible alarm sounds if attempting to forcibly remove the outside lock from the door.

User PIN Code: The User PIN code operates the lock when the Multi-Family Key module is not installed. Maximum number of user codes is 500.

Volume Setting Mode: The volume setting for PIN code verification is set to HIGH (1) by default; otherwise it can be set to Low (2) or Silent (3) for quiet areas. (Main Menu selection #4)

Wrong Code Entry Limit: After five (5) unsuccessful attempts at entering a valid PIN code, the lock will not accept a PIN code for the duration of the shutdown time. The touchscreen keypad will flash, and a red padlock symbol will be at the bottom of the keypad. The push button keypad will flash and the ACCENTRA icon will flash blue for the shutdown period. The keypad will be available after the shutdown time is complete.

Feature Programming Through Menu Mode Using Master PIN Code

  1. Activate the lock.
  2. Enter 4-8 digit Master PIN code* followed by the key. Lock Response: “Menu mode, enter a number (the entered digit corresponding to the function to be performed med), press the key to continue”.
  3. Follow the voice commands.
  4. Press the key to complete the process and conclude the programming session. *The Master PIN code must be created before any other programming of the lock.ACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (26)

Programming Troubleshooting

ACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (27)

NOTE: When batteries are replaced, Multi-Family Key module locks have a real-time clock that will be set through the Cloud Software User Interface. It is recommended to update the lock using the ACCENTRA Configuration app to verify the correct date and time, particularly for those locks operating under Daylight Saving Time (DST).

Hardware TroubleshootingACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (28)

Factory SettingsACCENTRA-NTB600TSACC-Cylindrical-Lock-Touchscreen-and-Push-Button-fig- (29)

FCC:
This equipment has been tested and found to comply with the limits for a Class B digital device, under Part 15 of the FCC Rules. These limits are designed to protect reasonably against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used by the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and the receiver. Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.

Contact Us

U.S.A.
ASSA ABLOY ACCENTRA
Address: 225 Episcopal Road Berlin, CT 06037-4004
Tel: 1-800-438-1951
Fax: 1-800-338-0965
accentra-assaabloy.com

Canada:
ASSA ABLOY Door Security Solutions Canada
Address: 160 Four Valley Drive Vaughan, Ontario L4K 4T9
Tel: 1-800-461-3007
Fax: 1-800-461-8989
assaabloydss.ca

International:
ASSA ABLOY Americas International
Tel: 1-905-821-7775
Fax: 1-905-821-1429
assaabloyai.com

Phone 1-800-810-9473
Customer Service Email: customerservice.accentra@assaabloy.com
Technical Product Support Email:techsupport.accentra@assaabloy.com
Order Entry Email: orders.accentra@assaabloy.com
Fax: 1-800-338-0965
Website : www.accentra-assaabloy.com

FAQs

Q: Can I retrofit or modify the product?
A: Retrofitting or modifying the product may impact fire rating, safety features, and warranty. Consult with code specifications to ensure compliance with all codes and ratings.

Q: How do I determine the handling of the door?
A: The hand of a door is determined from the secure side of the door. Follow the provided guidelines for left-hand, right-hand, hinges direction, and inward or outward opening.

Q: What batteries does the product use?
A: The product uses AA batteries for operation.