INSTRUCTIONS
- Single zone expander module for ESL and ESX systems.
- This device allows you to add detectors directly onto the Elite systems keypad bus.
- Each device takes up 1 radio zone slot. Multiple devices can be connected on one system.
- Its small size allows it to be installed inside a PIR.
Programming
For ESL & Elite-S follow <?> (in Green). For ESX follow <?> (in Red)
Zone Assignment
For a NANO-Z1 to work on the Elite system, you need to select a spare zone slot, Enable it and tell it to be a Radio Zone. This is done at address 122. In Installer mode press <PROGRAM> <122> <ENTER> then choose the zone
Note. Zones <9-16> on an ESL are already configured for a NANO-Z1 to be enrolled.
Zone Protocol
The NANO-Z1 communicates in the Freelink/Freewave Protocol. Before you Enroll the device, make sure the protocol is set correctly. This is done at address 127. In Installer mode press <PROGRAM> <127> <ENTER> then select the zone <1-16><1-64> and <ENTER>, now choose either type <3> or <4> and <ENTER>
Zone Enrolling
With the NANO-Z1 connected to the Keypad bus, you can now Enroll it into the Zone you have setup.
This is done at address 164. In Installer mode press <PROGRAM> <164> <ENTER> then select the zone <1-16><1-64> and <ENTER> <ENTER> Now turn Dipswitch 4 On (this should stop the KP beeping)