NANO-Z1
NANO-Z1 I NSTRUCTI ONS

Single zone expander module for ESL and ESX systems. This device allows you to add detectors directly onto the Elite systems keypad bus. Each device takes up 1 radio zone slot. Multiple devices can be connected on one system. I ts small size allows it to be installed inside a PI R.
PI N COLOUR FUNCTI ON

16.5mm

NANO Z1

1

Red + 12VDC I n

2 Black

-0VDC

41mm

3 Yellow

4

Blue

Clock Dat a

5 White

I nput

POS NEG CLK DAT
Elite Panel

100m Max. Ø0.2mm
NC

Normally Closed Contacts No EOL

POS NEG CLK DAT Elite Panel
POS NEG CLK DAT Elite Panel
POS NEG CLK DAT Elite Panel

100m Max. Ø0.2mm

Normally Open/ Closed Contacts 2K2 EOL

NO 2 K2
100m Max. Ø0.2mm

NC

2 K2

Normally Closed Contacts + Tamper 4K7 + 2K2 EOL

100m Max. Ø0.2mm

Relay NC
4 K7

Tamper NC
2 K2

Normally Open Contacts + Tamper 4K7 + 2K2 EOL

Relay NO
2 K2 4 K7
page 1/2

Tamper NC

Programming:
For ESL & Elite- S follow < ?> ( in Green) . For ESX follow < ?> ( in Red) .

Zone Assignment
For a NANO-Z1 to work on the Elite system, you need to select a spare zone slot, Enable it and tell it to be a Radio Zone. This is done at address 122. I n I nstaller mode press < PROGRAM> < 122> < ENTER> then choose the zone < 1- 16> < 1- 64> and < ENTER> , now turn ON options < 1> and < 5> then < ENTER> . i.e. P 122 E 7 E 5 E (zone 7 is now ready to be Enrolling).
option to be turned On zone number address
Note. Zones < 9- 16> on an ESL are already configured for a NANO-Z1 to be enrolled.

Zone Protocol

The NANO-Z1 communicates in the Freelink/ Freewave Protocol. Before you Enroll the device, make sure the protocol is

set correctly. This is done at address 127. I n I nstaller mode press < PROGRAM> < 127> < ENTER> then select the

zone < 1- 16> < 1- 64> and < ENTER> , now choose either type < 3> or < 4> and < ENTER> .

i.e. P 127 E 7 E 3 E (zone 7 is now on the Supervised Freelink protocol).

protocol Type zone number

Type 3 = Freelink with Supervised (monitors device) recommended

address

Type 4 = Freelink Non Supervised default on ESL & ESX

Zone Enrolling

With the NANO-Z1 connected to the Keypad bus, you can now Enroll it into the Zone you have setup. This is done at address 164. I n I nstaller mode press < PROGRAM> < 164> < ENTER> then select the zone < 1- 16> < 1- 64> and < ENTER> < ENTER> Now turn Dipswitch 4 On (this should stop the KP beeping) i.e. P 164 E 7 E E (the device should now be learnt into zone 7).
zone number address
Note. After device is learnt in turn Off Dipswitch 4.

Dip 4 On to Learn/ Find

Dip 4 Off to Use

Recommended Example:

POS NEG CLK DAT
Elite Panel

Normally Closed Contacts + Tamper 4K7 + 2K2 EOL
4 K7 2 K2

Specif ica t ions. Operating voltage:
9-16 VDC Current Draw:
15mA (plus detector) Cable Run:
100m max. (.2mm 4C) Communication Protocol:
Freelink Dimensions:
43 x 16.5 x 10mm

0 v 12v

EOL TAMPER EOL RELAY
Swan Quad PI R page 2/2

ARROWHEAD ALARM PRODUCTS Ltd.
1A Emirali Road, Silverdale 0932, Auckland, NZ
Ph. 09 414 0085 www.aap.co.nz v1.01

