Instructions for aap models including: NANO-Z1 Single Zone Expander Module, NANO-Z1, Single Zone Expander Module, Zone Expander Module, Expander Module, Module
NANO-Z1 - Accessories - Alarm Systems - Arrowhead Alarm Products
NANO-Z1 - Keypad Systems - Access Control - Arrowhead Alarm Products
File Info : application/pdf, 2 Pages, 156.29KB
DocumentDocumentNANO-Z1 I NSTRUCTI ONS Single zone expander module for ESL and ESX systems. This device allows you to add detectors directly onto the Elite systems keypad bus. Each device takes up 1 radio zone slot. Multiple devices can be connected on one system. I ts small size allows it to be installed inside a PI R. PI N COLOUR FUNCTI ON 16.5mm NANO Z1 1 Red + 12VDC I n 2 Black -0VDC 41mm 3 Yellow 4 Blue Clock Dat a 5 White I nput POS NEG CLK DAT Elite Panel 100m Max. Ø0.2mm NC Normally Closed Contacts No EOL POS NEG CLK DAT Elite Panel POS NEG CLK DAT Elite Panel POS NEG CLK DAT Elite Panel 100m Max. Ø0.2mm Normally Open/ Closed Contacts 2K2 EOL NO 2 K2 100m Max. Ø0.2mm NC 2 K2 Normally Closed Contacts + Tamper 4K7 + 2K2 EOL 100m Max. Ø0.2mm Relay NC 4 K7 Tamper NC 2 K2 Normally Open Contacts + Tamper 4K7 + 2K2 EOL Relay NO 2 K2 4 K7 page 1/2 Tamper NC Programming: For ESL & Elite- S follow < ?> ( in Green) . For ESX follow < ?> ( in Red) . Zone Assignment For a NANO-Z1 to work on the Elite system, you need to select a spare zone slot, Enable it and tell it to be a Radio Zone. This is done at address 122. I n I nstaller mode press < PROGRAM> < 122> < ENTER> then choose the zone < 1- 16> < 1- 64> and < ENTER> , now turn ON options < 1> and < 5> then < ENTER> . i.e. P 122 E 7 E 5 E (zone 7 is now ready to be Enrolling). option to be turned On zone number address Note. Zones < 9- 16> on an ESL are already configured for a NANO-Z1 to be enrolled. Zone Protocol The NANO-Z1 communicates in the Freelink/ Freewave Protocol. Before you Enroll the device, make sure the protocol is set correctly. This is done at address 127. I n I nstaller mode press < PROGRAM> < 127> < ENTER> then select the zone < 1- 16> < 1- 64> and < ENTER> , now choose either type < 3> or < 4> and < ENTER> . i.e. P 127 E 7 E 3 E (zone 7 is now on the Supervised Freelink protocol). protocol Type zone number Type 3 = Freelink with Supervised (monitors device) recommended address Type 4 = Freelink Non Supervised default on ESL & ESX Zone Enrolling With the NANO-Z1 connected to the Keypad bus, you can now Enroll it into the Zone you have setup. This is done at address 164. I n I nstaller mode press < PROGRAM> < 164> < ENTER> then select the zone < 1- 16> < 1- 64> and < ENTER> < ENTER> Now turn Dipswitch 4 On (this should stop the KP beeping) i.e. P 164 E 7 E E (the device should now be learnt into zone 7). zone number address Note. After device is learnt in turn Off Dipswitch 4. Dip 4 On to Learn/ Find Dip 4 Off to Use Recommended Example: POS NEG CLK DAT Elite Panel Normally Closed Contacts + Tamper 4K7 + 2K2 EOL 4 K7 2 K2 Specif ica t ions. Operating voltage: 9-16 VDC Current Draw: 15mA (plus detector) Cable Run: 100m max. (.2mm 4C) Communication Protocol: Freelink Dimensions: 43 x 16.5 x 10mm 0 v 12v EOL TAMPER EOL RELAY Swan Quad PI R page 2/2 ARROWHEAD ALARM PRODUCTS Ltd. 1A Emirali Road, Silverdale 0932, Auckland, NZ Ph. 09 414 0085 www.aap.co.nz v1.01