LS GSL-D22C Programmable Logic Controller Installation Guide
LS GSL-D22C Programmable Logic Controller

This installation guide provides simple function information or PLC control. Please read carefully this data sheet and manuals before using products. Especially read precautions then handle the products properly.

Safety Precautions

  • Meaning of warning and caution label

Warning Icon WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury

Warning Icon CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
It may also be used to alert against unsafe practices

Warning Icon WARNING

  1. Do not contact the terminals while the power is applied.
  2. Be sure there are no foreign metallic matters.
  3. Do not manipulate the battery(charge, disassemble, hitting, short, soldering).

Warning Icon CAUTION

  1. Be sure to check the rated voltage and terminal arrangement before wiring
  2. When wiring, tighten the screw of terminal block with the specified torque range
  3. Do not install the flammable things on surroundings
  4. Do not use the PLC in the environment of direct vibration
  5. Except expert A/S staff, do not disassemble or fix or modify the product
  6. Use the PLC in an environment that meets the general specifications contained in this datasheet.
  7. Be sure that external load does not exceed the rating of output module.
  8. When disposing of PLC and battery, treat it as industrial waste.
  9. I/O signal or communication line shall be wired at least 100mm away from a highvoltage cable or power line.

Operating Environment

  • To install, observe the below conditions.
No Item Specification Standard
1 Ambient temp. 0 ~ 55℃
2 Storage temp. -25 ~ 70℃
3 Ambient humidity 5 ~ 95%RH,  non-condensing
4 Storage humidity 5 ~ 95%RH,  non-condensing
5 Vibration Resistance Occasional vibration
Frequency Acceleration IEC 61131-2
5≤f<8.4㎐ 3.5mm 10 times in each direction for X, Y, Z
8.4≤f≤150㎐ 9.8㎨(1g)
Continuous vibration
Frequency Frequency Frequency
5≤f<8.4㎐ 1.75mm
8.4≤f≤150㎐ 4.9㎨(0.5g)

Accessories and Cable Specifications

  • Check Modbus connector contained in the box
    1. Usage: Modbus Communication Connector
    2. Item: GSL-CON
  • When using RS-422 or RS-485 communication channel, twisted pair cable shall be used with consideration of communication distance and speed.
    1. Item: Low Capacitance LAN Interface Cable
    2. Type: LIREV-AMESB
    3. Size: 2P X 22AWG(D/0.254 TA)
    4. Manufacturer: LS Cable Co., Ltd
    5. Electrical characteristics
Items Unit Characteristics Condition
Conductor Resistance Ω/km 59 or less 25℃
Withstanding Voltage (DC) V/1min 500V, 1Min. In air
Insulation Resistance MΩ-km 1,000 or more 25℃
Capacity Pf/M 45 or less 1kHz
Characteristic Impedance 120±12 10MHz

Dimension (mm)

  • This is front part of the product. For more information, refer to user’s manual.
    Dimension
    Dimension
    Dimension
    Dimension

Performance Specifications

  • This is performance specifications of the product. For more information, refer to user manual.
Item GSL-D2xC GSL-DT4C/C1 GSL- TRxC/C1 GSL-RY2C
Baud rate 2,400 ~ 38,400 bps
Protocol Modbus RTU
Rated Input Current 5mA
Rated load voltage DC24V DC24V/AC220V,2A/Point, 5A/COM
Max load 0.5A/Point, 3A/COM DC 110V, AC 250V1,200times/hour
ON Voltage DC 19V or above Minimum load voltage/current DC 5V/1mA
OFF Voltage DC 6V or less

Terminal Block Layout for I/O Wiring

  • This is terminal block layout for I/O wiring. Refer to each name when driving the system.
    For more information, refer to user manual.

<GSL-D22C>
Terminal Block Wiring

<GSL-TR2C>
Terminal Block Wiring

<GSL-TR2C1>
Terminal Block Wiring

<GSL-D24C>
Terminal Block Wiring

<GSL-TR4C>
Terminal Block Wiring

<GSL-TR4C1>
Terminal Block Wiring

<GSL-DT4C (Output)>
Terminal Block Wiring

<GSL-DT4C1 (Output)>
Terminal Block Wiring

<GSL-DT4C/C1 (Input)>
Terminal Block Wiring

<GSL-RY2C>
Terminal Block Wiring

Wiring

  • Wiring for Communication
    <RS-422 Connection>
    Wiring
    <RS-485 Connection>
    Wiring
    1. For more information about wiring, refer to user manual.

Warranty

  • The warranty period is 36 months from the date of manufacture.
  • The initial diagnosis of faults should be conducted by the user. However, upon request, LS ELECTRIC or its representative(s) can undertake this task for a fee. If the cause of the fault is found to be the responsibility of LS ELECTRIC, this service will be free of charge.
  • Exclusions from warranty
    1. Replacement of consumable and life-limited parts (e.g. relays, fuses, capacitors, batteries, LCDs, etc.)
    2. Failures or damages caused by improper conditions or handling outside those specified in the user manual
    3. Failures caused by external factors unrelated to the product
    4. Failures caused by modifications without LS ELECTRIC’s consent
    5. Use of the product in unintended ways
    6. Failures that cannot be predicted/solved by current scientific technology at the time of manufacture
    7. Failures due to external factors such as fire, abnormal voltage, or natural disasters
    8. Other cases for which LS ELECTRIC is not responsible
  • For detailed warranty information, please refer to the user’s manual.
  • The content of the installation guide is subject to change without notice for product performance improvement.

Symbols
Symbols

QR Code
QR Code

LS ELECTRIC Co., Ltd.
www.ls-electric.com
10310000311 V4.2 (2024.6)

  • E-mail: automation@ls-electric.com
  • Headquarter/Seoul Office
  • LS ELECTRIC Shanghai Office (China)
  • LS ELECTRIC (Wuxi) Co., Ltd. (Wuxi, China)
  • LS-ELECTRIC Vietnam Co., Ltd. (Hanoi, Vietnam)
  • LS ELECTRIC Middle East FZE (Dubai, U.A.E.)
  • LS ELECTRIC Europe B.V. (Hoofddorf, Netherlands)
  • LS ELECTRIC Japan Co., Ltd. (Tokyo, Japan)
  • LS ELECTRIC America Inc. (Chicago, USA)
  • Tel: 1-800-891-2941
  • Tel: 82-2-2034-4033,4888,4703
  • Tel: 86-21-5237-9977
  • Tel: 86-510-6851-6666
  • Tel: 84-93-631-4099
  • Tel: 971-4-886-5360
  • Tel: 31-20-654-1424
  • Tel: 81-3-6268-8241

Company Logo

Documents / Resources

LS GSL-D22C Programmable Logic Controller [pdf] Installation Guide
GSL-D22C Programmable Logic Controller, GSL-D22C, Programmable Logic Controller, Logic Controller, Controller

References

Leave a comment

Your email address will not be published. Required fields are marked *