SEALEY-logo

SEALEY SDH102.V2 Dehumidifier with Laundry Mode

SEALEY-SDH102-V2-Dehumidifier-with-Laundry-ProductSpecifications

  • Model Number: SDH102.V2
  • Capacity: 10 liters
  • Special Mode: Laundry Mode

Product Usage Instructions

Safety Precautions
It is important to follow these safety precautions to ensure safe operation of the dehumidifier:

  • Check all electrical connections for wear and damage before use.
  • Keep the dehumidifier at least 30cm away from objects on all sides and 50cm above it.
  • Avoid obstructing air intakes or outlets and do not cover the dehumidifier with clothes.
  • Do not touch the outlets as the fan inside runs at high speed.
  • Operate the dehumidifier only when fully alert and not under the influence of substances.
  • Always switch the dehumidifier off using the OFF position before disconnecting it.
  • Avoid placing near heat sources, radiators, or tipping the unit to prevent damage.

Product Usage

  1. Place the dehumidifier in a well-ventilated area with sufficient space around it.
  2. Ensure the water collection tank is properly inserted and the float lever is in place.
  3. Plug the dehumidifier into a suitable power outlet matching the voltage rating.
  4. Turn on the dehumidifier using the designated power switch.
  5. Select the desired mode, including the Laundry Mode if applicable.
  6. Monitor the water level in the collection tank and empty it as needed.
  7. Maintain regular cleaning of air intakes and outlets to ensure optimal performance.

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble-free performance.

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

SEALEY-SDH102-V2-Dehumidifier-with-Laundry-fig-1

This appliance contains approximately 45g of R290 refrigerant gas.
The appliance shall be installed, operated, and stored in a room with a floor area larger than 4m².

SAFETY

WARNING! It is the user’s responsibility to check the following:

Check all electrical equipment and appliances to ensure that they are safe before use. Inspect power supply leads, plugs, and all electrical connections for wear and damage. Sealey recommended that an RCD (Residual Current Device) is used with all electrical products.

Electrical safety informatioThe following information must be read and understood: Ensure that the insulation on all cables and the appliance is safe before connecting it to the power supply. Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

Important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the correct fuse.

  • DO NOT pull or carry the appliance by the power cable.
  • DO NOT pull the plug from the socket by the cable.
  • DO NOT use worn or damaged cables, plugs, or connectors. Ensure that any faulty item is repaired or replaced immediately by a qualified electrician.
  • If the cable or plug is damaged during use, switch off the electricity supply and remove it from use.
  • Ensure that repairs are carried out by a qualified electrician
  • DO NOT stand or place any object less than 30cm from the front of the unit, 30cm from the rear and sides of the unit, and 50cm above the unit.
  • DO NOT obstruct the air intake or outlets of the dehumidifier, and DO NOT cover it with washed clothes.
  • DO NOT place any object into the outlets – the unit has a fan running at high speed, contact with this will cause injury.
  • DO NOT operate the dehumidifier when you are tired or under the influence of alcohol, drugs, or intoxicating medication.
  • DO NOT switch the dehumidifier off by disconnecting it from the mains. ALWAYS switch to the “OFF” position first.
  • DO NOT remove the float lever from the water collection tank.
  • DO NOT connect or disconnect the plug from the mains with wet hands.
  • DO NOT use the dehumidifier outside.
  • DO NOT place the dehumidifier near to radiators or other heating appliances.
  • DO NOT tip to any side as escaping water could damage the appliance
  • ALWAYS discard the water from the collection tank, DO NOT use it for any other purpose.
  • Only operate the dehumidifier on a level and stable surface.
  • To prevent water from freezing, DO NOT use the dehumidifier at ambient temperatures below 5°C.
  • Ensure that heating appliances are not exposed to the flow of air from the dehumidifier.
  • Before attempting to move the dehumidifier, empty the contents of the collection tank.
  • Use the top carrying handle when moving the unit.
  • Switch off and disconnect it from the mains before attempting any cleaning or other maintenance work.
  • Ensure that the dehumidifier is correctly turned off when not in use, and stored in a safe, dry area, out of reach of children.
    NOTE: This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

SAFETY PRECAUTIONS ON SERVICING

WARNING: Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely by an industry-recognized assessment specification.

WARNING: Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.

WARNING: If you don’t understand something or need help, please contact Sealey.

CHECKS TO THE AREA
Before beginning working on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with before conducting work on the system.

WORK PROCEDURE
Work shall be undertaken under a controlled procedure to minimize the risk of flammable gas or vapor being present while the work is being performed.

GENERAL WORK AREA
All maintenance staff and others working in the local area shall be instructed on the nature of wthe work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.

CHECKING FOR THE PRESENCE OF REFRIGERANT
The area shall be checked with an appropriate refrigerant detector before and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable
refrigerants, i.e. no sparking, adequately sealed, or intrinsically safe.

PRESENCE OF FIRE EXTINGUISHER
If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.

NO IGNITION SOURCES
No person carrying out work about a refrigeration system that involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repair, removal, and disposal, during which flammable refrigerant can be released into the surrounding space. Before work takes place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed.

VENTILATED AREA
Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.

CHECKS TO THE REFRIGERATION EQUIPMENT
Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the 1.3.7. VENTILATED AREA Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.

CHECKS TO THE REFRIGERATION EQUIPMENT
Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance.

The following checks shall be applied to installations using flammable refrigerants:

  • The charge size is the room size within which the refrigerant-containing parts are installed.
  • The ventilation machinery and outlets are operating adequately and are not obstructed.
  • If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant.
  • Marking the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected.
  • Refrigeration pipes or components are installed in a position where they are unlikely to be exposed to any substance which may corroderefrigerant-containingg components unless the components are constructed of materials that are inherently resistant to being corroded or are suitably protected against being so corroded.

CHECKS TO ELECTRICAL DEVICES
Repair and maintenance of electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.

Initial safety checks shall include

  • Those capacitors are discharged: this shall be done safely to avoid the possibility of sparking.
  • That no live electrical components and wiring are exposed while charging, recovering, or purging the system.
  • That there is continuity of earth bonding.

INTRODUCTION

Compact, efficient, low-noise portable unit that extracts up to 10L of water per day. Removes excess moisture from the air to prevent the build-up of mildew and mold. Features adjustable 224-hour timer, water-full indicator, and auto-defrosting. Digital control panel, LED display,y, and 3-colour indicator to show different RH% levels. Continuous/Laundry mode function accelerates the drying cycle allowing you to dry clothes quicker and eliminate odors. The refrigerant is environmentally friendly R290. Supplied with drain hose for continuous operation.

SPECIFICATION

  • Model No:……………………………………………..SDH102.V2
  • CO2 Equivalent:……………………………………………………..0
  • Condensate Tank:……………………2L (with Auto-Shut-Off)
  • Dehumidifying Capacity:……..10L/Day @ 30oC, 80% RH
  • Freezing Pressure (Max):……………………………….3.2MPa
  • Fuse Rating:……………………………………………………..10A
  • Global Warming Potential (Rating):…………………………..3
  • IP Rating:………………………………………………………..IPX1
  • Mass:……………………………………………………………….45g
  • Maximum Airflow:………………………………………..120m³/hr
  • Plug Type:……………………………………………………….3-Pin
  • Power:……………………………………………………………195W
  • Power Supply Cable Length:…………………………………2m
  • Refrigerant:…………………………………………………….R290
  • Steaming Pressure (Max):……………………………..3.2MPa
  • Supply:……………………………………………………………230V
  • Working Space:………………………………………………..15m³
  • Working Temperature:…………………………………….5-35°C

OPERATION

  • NOTE: Empty the water tank before every use.
  • NOTE: During operation keep doors and windows closed.
  • NOTE: Place the unit in the area to be dehumidified ensuring that inlet and outlet grilles are unobstructed and that the unit is positioned as stated in section 1.2. Close all doors and windows.

POWER    SEALEY-SDH102-V2-Dehumidifier-with-Laundry-fig (2)

SEALEY-SDH102-V2-Dehumidifier-with-Laundry-fig (3)

  • After switching on the power, all indicators and the LED screen will be on for 1 second and then off. After a buzzer, the power indicator will be on and the machine will be in standby mode.
  • Press the power button and the machine starts to run. Initially, the machine’s settings are 60%RH humidity, automatic mode, and high-speed operation.
  • Press this key againand, and the machine will stop running, and the fan will stop. The power light will remain lit.

MODE   SEALEY-SDH102-V2-Dehumidifier-with-Laundry-fig (4)

  • To select mode press the mode button to switch between modes. The corresponding code indicator will light up on the LED screen.

Auto Mode

  • The corresponding code indicator A will light up on the LED screen.
  • When the environmental humidity is greater than or equal to the set humidity by +3%, the fan and compressor start working after 3 seconds.
  • When the environmental humidity is less than or equal to the set humidity by -3%, the compressor stops working and the fan will shut down.
    NOTE: Both fan speed and humidity can be adjusted while running in auto mode.

Continuous Drying/Laundry Mode
The corresponding code indicator (Cnt) will light up on the LED screen. The machine continues to run, but the humidity cannot be adjusted.

Sleep mode
The corresponding code indicator ( SEALEY-SDH102-V2-Dehumidifier-with-Laundry-fig (5)) will light up on the LED screen. After 10 seconds of idling, all indicators gradually fade and the fan speed is automatically switched from high to low. Press the timer button to set the required sleep period. Touch any button to wake up the indicator. Press the mode button again to exit the sleep mode.
NOTE: In sleep mode, fault codes are not displayed, and fan speed is not adjustable but the humidity is adjustable.

HUMIDITY SETTING   SEALEY-SDH102-V2-Dehumidifier-with-Laundry-fig (6)

  • In automatic mode or sleep mode press the button to adjust the set humidity. Each press increments the setting by 5%. Once 80% is reached the value set cycles back to 30%.
  • If the button is held down continuously the unit will display the current ambient temperature.

TIMER  SEALEY-SDH102-V2-Dehumidifier-with-Laundry-fig (7)

  • The timer can be set from 0-24 hours in 1-hour increments. Set the value to “00” to cancel the timer function.
  • After the timer is set, the timer LED is on during the timing period. After the timing is over, the timer LED turns off.
  • To set the running time turn the unit off.
  • To set the standby time turn the unit on.

FAN SPEED  SEALEY-SDH102-V2-Dehumidifier-with-Laundry-fig (8)

  • The timer can be set from 0-24 hours in 1-hour increments. Set the value to “00” to cancel the timer function. 4.4.2. After the timer is set, the timer LED is on during the timing period. After the timing is over, the timer LED turns off.
  • To set the running time turn the unit off.
  • To set the standby time turn the unit on.

LOCK  SEALEY-SDH102-V2-Dehumidifier-with-Laundry-fig (9)

Press this button to engage the child lock function. The child lock indicator light is on when set. All other keys are locked and cannot be operated. Press this button again, the indicator light will go out, and the button will be restored.

DRAINAGE

 WATER TANK

  • When the water tank is full the warning light on the control panel will flash, the unit will stop working and a buzzer will sound.
  • To remove the water tank first remove the lower rear cover by gently pulling it from both sides using grip recesses to pull it.
  • Carefully slide the water tank forward making sure no spillage occurs.
  • Before replacing the water tank dry it off thoroughly and also remove any mildew deposits.5.2.

CONTINUOUS DRAINAGE

  • Connect a water pipe (not supplied) to the drain on the rear of the unit.
  • The water pipe requires an inner diameter of 9mm and should not be longer than 1.5 meters.
  • Ensure the connection does not leak.

WARNING! The water pipe must ALWAYS be lower along all of its length than the unit outlet drain height.

MAINTENANCE

WARNING! Switch the machine off and unplug from the mains before carrying out any maintenance or cleaning.

FILTER CLEANING

  • It is recommended that the air filter is cleaned every two weeks maximum.
  • To remove the filter, remove the air tank and gently pull down the exposed tab of the filter.
  • The filter may only be washed with water.

DO NOT use hot water. Leave to dry naturally.
DO NOT use solvent cleaners nor use heat to dry the filter.

  • Once dry, replace the filter by snapping it back into place, making sure that the lower edge fits behind the casing locations and that all the lugs are sprung gently into place thus holding the filter up inside the casing.

CLEANING THE CASING
The casing may be cleaned by rubbing over with a damp cloth.

  • DO NOT use detergents, abrasive, or solvent cleaners as these will damage the surface finish.
  • DO NOT allow the control panel to become wet.

TROUBLESHOOTING

SYMPTOM POTENTIAL CAUSE POSSIBLE REMEDY
The unit does not operate Is the power supply connected? Insert the plug into an electrical outlet fully and securely – check fuse in the plug is OK.
Check to see if the water tank is full of water i.e. is the water level warning light on? Remove front cover

Empty water out of the tank.

Check to see if the water tank is fitted properly in position. Remove the front cover and reposition the tank.
The dehumidified volume

is small

Is the filter dirty / clogged? Clean filter section
Check for any obstructions to the front and back air inlets/outlets of the unit. See section
Low ambient temp. The unit does not work below approx 5oC.
Low ambient humidity. The unit has reached the required level set.
Humidity remains too high. The room size may be too large. Room size may exceed 12m3.
Doors and windows may be opened and closed frequently. Keep doors and windows shut during operation.
The dehumidifier is used together with a kerosene heater which emits water vapor. Turn the heater off.
E2 Humidity sensor problem Change a sensor
LO Environmental humidity is below 20% The unit shuts down.
HI Environmental humidity is above 90%
CL Low-temperature protection, the environmental temperature<50C
CH High-temperature protection, the environmental temperature>380C

  SEALEY-SDH102-V2-Dehumidifier-with-Laundry-fig 10WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid waste authority for recycling information.

SEALEY-SDH102-V2-Dehumidifier-with-Laundry-fig-11ENVIRONMENT PROTECTION

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories, and packaging should be sorted, taken to a recycling center, and disposed of in a mannerthath is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids according to local regulations.

SEALEY-SDH102-V2-Dehumidifier-with-Laundry-fig-12

Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications, and parts without prior notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call our technical team at technical@sealey.co.uk or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: The guarantee is 12 months from the purchase date, proof of which is required for any claim.

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR

FAQS

  • Q: Can the dehumidifier be used outdoors?
    A: No, it is recommended to use the dehumidifier indoors only.
  • Q: What should I do if the power cable or plug is damaged?
    A: Switch off the electricity supply, remove the dehumidifier from use, and have repairs done by a qualified electrician.
  • Q: How often should I clean the air intake and outlets?
    A: Regularly inspect and clean the air intakes and outlets to prevent blockages, especially if operating in dusty environments.

Documents / Resources

SEALEY SDH102.V2 Dehumidifier with Laundry Mode [pdf] User Manual
SDH102.V2 Dehumidifier with Laundry Mode, SDH102.V2, Dehumidifier with Laundry Mode, Laundry Mode, Mode, Dehumidifier

References

Leave a comment

Your email address will not be published. Required fields are marked *