Ilogo ye-Logicbus

tGW-700
I-Modbus/TCP encane eya ku-RTU/ASCII Gateway
Ukuqala Ngokushesha

Yini esebhokisini?

Ngaphezu kwalo mhlahlandlela, iphakheji ihlanganisa izinto ezilandelayo:

I-Logicbus TGW 700 Tiny Modbus TCP to RTU ASCII Gateway - Yini esebhokisini

I-Logicbus TGW 700 Tiny Modbus TCP to RTU ASCII Gateway

Umkhiqizo Webindawo: https://www.icpdas-usa.com/tgw_700_modbus_tcp_to_rtu_ascii_device_servers.html

Ixhuma i-PC yamandla ne-Host

  1. Qiniseka ukuthi i-PC yakho inezilungiselelo zenethiwekhi ezisebenzayo.
    Khubaza noma ulungiselele kahle i-Windows firewall yakho kanye ne-Anti-Virus firewall kuqala, kungenjalo "Amaseva Wokusesha" eSahlukweni 5 angase angasebenzi. (Sicela uthinte Umlawuli wesistimu yakho)
  2. Xhuma kokubili i-SGW-700 ne-PC yakho kunethiwekhi engaphansi efanayo noma kuswishi ye-Ethernet efanayo.
  3. Faka amandla (i-PoE noma +12~+48 VDC) ku-SGW-700.

I-Logicbus TGW 700 Tiny Modbus TCP to RTU ASCII Gateway - Ixhuma I-PC Yamandla ne-Host

Ifaka iSoftware ku-PC yakho

Faka i-eSearch Utility, engatholwa kufayela le webindawo: I-Logicbus TGW 700 Tiny Modbus TCP to RTU ASCII Gateway - PC

http://ftp.icpdas.com/pub/cd/tinymodules/napdos/software/esearch/

Izintambo Amanothi

Amanothi Okufakwa Kwezintambo Ze-RS-232/485/422 Interfaces:

I-Logicbus TGW 700 Tiny Modbus TCP to RTU ASCII Gateway - Wiring Notes

Ukuxhuma Amadivayisi e-Modbus

  1. Xhuma idivayisi ye-Modbus (isb, i-M-7022, ozikhethela yona) ku-COM1 ku-tGW-700.
  2. Faka amandla kudivayisi ye-Modbus (isb, i-M-7022, i-ID yedivayisi:1).

isixwayiso Qaphela: Indlela yokufaka izintambo kanye nokuphakela amandla incike kudivayisi yakho ye-Modbus.

I-Logicbus TGW 700 Tiny Modbus TCP to RTU ASCII Gateway - Ixhuma Amadivayisi e-Modbus

Ilungiselela Izilungiselelo Zenethiwekhi

  1. Chofoza kabili isinqamuleli se-eSearch Utility kudeskithophu.
  2. Chofoza okuthi “Sesha amaseva” ukuze useshe i-tGW-700 yakho.
  3. Chofoza kabili igama le-tGW-700 ukuze uvule ibhokisi lengxoxo elithi “Lungisa Iseva (UDP)”.
    I-Logicbus TGW 700 Tiny Modbus TCP to RTU ASCII Gateway - Ilungiselela Izilungiselelo ZenethiwekhiIzilungiselelo Ezizenzakalelayo Zasefekthri ze-tGW-700:
    Ikheli le-IP 192.168.255.1
    Imaski ye-Subnet 255.255.0.0
    Isango 192.168.0.1

     

  4.  Xhumana Nomlawuli Wenethiwekhi yakho ukuze uthole ukucushwa kwenethiwekhi okulungile (okufana ne-IP/Mask/Gateway). Faka izilungiselelo zenethiwekhi bese uchofoza "Kulungile".
    isixwayiso Qaphela: I-tGW-700 izosebenzisa izilungiselelo ezintsha kumasekhondi angu-2 kamuva.I-Logicbus TGW 700 Tiny Modbus TCP to RTU ASCII Gateway - Gateway

     

  5. Linda imizuzwana emi-2 bese uchofoza inkinobho ethi “Sesha amaseva” futhi ukuze uqinisekise ukuthi i-tGW-700 isebenza kahle ngokucushwa okusha. 
  6. Chofoza igama le-tGW-700 ukuze uyikhethe. 
  7. Chofoza u-“Web” inkinobho yokungena ku- web amakhasi okumisa.
    (Noma faka i URL ikheli le-tGW-700 kubha yekheli lesiphequluli.)I-Logicbus TGW 700 Tiny Modbus TCP to RTU ASCII Gateway - ukucushwa

Ilungiselela i-Serial Port

Qaphela ukuthi uma uhlose ukusebenzisa i-Internet Explorer, qinisekisa ukuthi umsebenzi wenqolobane uvaliwe ukuze uvimbele amaphutha okufinyelela isiphequluli, sicela uvale inqolobane yakho ye-Internet Explorer ngale ndlela elandelayo: (Uma ungasebenzisi isiphequluli se-IE, sicela weqe lesi sinyathelo.)

Isinyathelo: Chofoza “Amathuluzi” >> “Izinketho ze-inthanethi…” ezintweni zemenyu.
Isinyathelo 2: Chofoza u- "General" ithebhu bese uchofoza inkinobho “Izilungiselelo…” inkinobho ku-Inthanethi Yesikhashana files uhlaka.
Isinyathelo3: Chofoza “Konke ukuvakashela ikhasi” bese uchofoza ku "KULUNGILE" ebhokisini elithi Izilungiselelo kanye nebhokisi lezinketho ze-inthanethi.

Ukuze uthole imininingwane eyengeziwe, bheka “I-FAQ: Ungaligwema kanjani iphutha lokufinyelela isiphequluli elidala a  ikhasi elingenalutho elizoboniswa uma usebenzisa i-Internet Explorer”

  1. Faka iphasiwedi endaweni yokungena ngemvume bese uchofoza "Thumela".
    I-Logicbus TGW 700 Tiny Modbus TCP to RTU ASCII Gateway - admin
  2. Chofoza ithebhu ethi “Port1” ukuze ubonise ikhasi elithi “Port1 Settings”.
  3. Khetha i-Baud Rate efanele, i-Data Format, ne-Modbus Protocol (isb, 19200, 8N2, ne-Modbus RTU) kokukhethwa kukho okudonsela phansi okuhlobene.
    isixwayiso Qaphela: Izinga le-Baud Rate, Ifomethi Yedatha, kanye nezilungiselelo zephrothokholi ye-Modbus zincike kudivayisi yakho ye-Modbus.
  4. Chofoza okuthi “Hambisa” ukuze ulondoloze izilungiselelo zakho.
    I-Logicbus TGW 700 Tiny Modbus TCP to RTU ASCII Gateway - izilungiselelo

Ukuzihlola

  1. Ku-eSearch Utility, khetha into ethi “Modbus TCP Master” kumenyu ethi “Amathuluzi” ukuze uvule I-Modbus TCP Master Utility.
    I-Logicbus TGW 700 Tiny Modbus TCP to RTU ASCII Gateway - Ukuzihlola2) Esisetshenziswa se-Modbus TCP Modbus Utility, faka ikheli le-IP le-tGW-700 bese uchofoza okuthi “Xhuma” ukuze uxhume i-tGW-700.3) Bhekisela esigabeni esithi “Incazelo Yephrothokholi” bese uthayipha umyalo we-Modbus kunkambu ethi “Command” bese uchofoza. "Thumela umyalo".
    4) Uma idatha yempendulo ilungile, kusho ukuthi ukuhlolwa kuphumelele.
    isixwayiso Qaphela: Izilungiselelo zomyalo we-Modbus zincike kudivayisi yakho ye-Modbus.

    I-Logicbus TGW 700 Tiny Modbus TCP to RTU ASCII Gateway - impumelelo

Amadokhumenti / Izinsiza

I-Logicbus TGW-700 Tiny Modbus TCP to RTU ASCII Gateway [pdf] Umhlahlandlela Womsebenzisi
TGW-700, Tiny Modbus TCP to RTU ASCII Gateway

Izithenjwa

Shiya amazwana

Ikheli lakho le-imeyili ngeke lishicilelwe. Izinkambu ezidingekayo zimakiwe *