Zigbee SR-ZG9042MP Three Phase Power Meter
Specifications
- Product Name: ZigBee Three-Phase Power Meter
- Power Input: 100-240Vac
- Dimensions: 18mm x 66mm
- Reset Key: Allows for factory reset of the device
Product Usage Instructions
Installation
- Ensure that the power meter is compatible with your power input range (100-240Vac).
- Locate a suitable location to install the power meter, ensuring it is easily accessible.
- Connect the power meter to the power source using the appropriate cables.
- Secure the power meter in place using screws or mounting brackets.
Functionality
- The ZigBee Three-Phase Power Meter allows you to monitor and track power consumption across three phases (A, B, C).
Resetting the Device
- To perform a factory reset of the device, press and hold the Reset Key for 10 seconds. This will restore the power meter to its default settings.
Important:
- Read All Instructions Before Installation
Function introduction
Product Data
Input Voltage | Power Consumption | Ammeters | Voltmeters accuracy | Ammeters accuracy | Size(LxWxH) |
100-240VAC | <3W | 0-200A | ±1 % | ±1 % (2 – 200 A),
±2 % (1 – 2 A), ±5 % (0 – 1 A) |
90x66x18mm |
- Precise 3-phase energy metering based on the latest ZigBee 3.0 protocol
- 4 Quadrant measurement
- Up to 200A per phase
- Solar and Wind power compatible
- Factory calibrated with over 99% accuracy
- Multiple connection types
- Current transformer connection
- DIN mountable
Power and energy meters:
- Active and apparent power
- Active and apparent energy
- Power factor
- Fundamental active and fundamental reactive energy
Safety & Warnings
- DO NOT install with power applied to the device.
- DO NOT expose the device to moisture.
Operation
Join Zigbee Network
Step 1:
- Operate your ZigBee Controller (Gateway) to add a device.
Step 2:
- Press the button on the device 5 times continuously.
- If the device is not connected to a network, it will directly enter network paring mode, the LED will flash quickly;
- If connected to a network, it will automatically exit the network, the LED will flash 3 times to indicate a successful network exit. After a few seconds, the device will automatically enter network pairing mode, the LED will flash quickly.
Step 3:
- Wait for this process to finish. If the connection is successful, the LED will flash 3 times, otherwise the LED will go off.
- Re-powering the device: if the LED flashes quickly, the device isn’t connected to a network; Otherwise, it has been connected to a network.
- When the device is working properly, the LED flashes slowly with a frequency of 1s. When EEPROM reading is abnormal, the LED flashes once within 1.5s.
Exit ZigBee Network
Method 1:
- Operate your gateway to delete the device, the LED will flash 3 times to indicate a successful network exit. Method 2: Press the button on the device 5 times continuously, the LED will flash 3 times to indicate a successful network exit.
Factory Reset
- Long press the button for over 10s, the LED will flash slowly then stay on for 3s to indicate a successful reset.
Note:
- After the device exits the Zigbee network, the device’s bind table will be cleared. Electrical consumption data will not be cleared unless the device is restored to factory settings or receives a “Reset to Factory Defaults Command” after being added to the network.
Zigbee Interface
Zigbee application endpoints:
Endpoint | Profile | Application |
0(0x00) | 0x0000(ZDP) | ZigBee Device Object (ZDO) – standard management features |
1(0x01) | 0x0104(HA) | Simple sensor, DeviceID = 0x000C |
242 | 0x0104(HA) | Green power, DeviceID = 0x0301 |
- Application Endpoint #0-ZDO Device standard management features.
Application endpoint #1-Thermostat
Cluster | Supported | Description |
0x0000 |
Server |
Basic
Provides basic information about the device, such as the manufacturer ID, vendor and model name, stack profile, ZCL version, production date, hardware revision etc. Allows a factory reset of attributes, without the device leaving the network. |
0x0003 |
Server |
Identify
Allows to put the endpoint into identify mode. Useful for identifying/locating devices and required for Finding & Binding. |
0x0004 |
Server |
Groups
Allows adding this endpoint to one or more groups. Afterwards the endpoint can be addressed using the group address. This is also a prerequisite for scenes. You may also query group membership and delete group associations. |
0x0005 |
Server |
Scenes
Allows storing one or more scenes per group, where each scene consists of a pre-set on/off state value. You may either store the current values as a scene, or provide scene settings when adding a scene, or delete scenes. |
0x0B04 | Server | Electrical Measurement |
0x0702 | Server | Simple Meter |
0x0019 |
Client |
OTA Upgrade
Pull-oriented firmware upgrade. Searches the network for mating servers and allows the server to control all stages of the upgrade process, including which image to download, when to download, at what rate and when to install the downloaded image. |
Basic – 0x0000(Server) Attributes supported:
Attribute | Type | Description |
0x0000 | INT8U, read-only | ZCLVersion |
0x0001 | INT8U, read-only | ApplicationVersion |
0x0002 | INT8U, read-only | StackVersion |
0x0003 | INT8U, read-only | HWVersion |
0x0004 | string, read-only | ManufacturerName |
0x0005 | string, read-only | ModelIdentifier |
0x0006 | string, read-only | DateCode NULL |
0x0007 | ENUM8, read-only | PowerSource
The type of power source for the device. Fixed value: 0x01 Mains (single phase) |
0x0008 | ENUM8, read-only | GenericDevice-Class 0XFF |
0x0009 | ENUM8, read-only | GenericDevice-Type 0XFF |
0x000A | octstr, read-only | ProductCode 00 |
0x000B | string, read-only | ProductURL NULL |
0x4000 | string, read-only | Sw build id 6.10.3.0 |
Command supported:
Command | Description |
0x00 |
Reset to Factory Defaults Command
On receipt of this command, the device resets all the attributes of all its clusters to their factory defaults. Note that networking functionality, bindings, groups, or other persistent data are not affected by this command. |
Identify – 0x0003(Server)
Attributes supported:
Attribute | Type | Description |
0x0000 | Int16U | Identify time |
Receive command supported:
Command | Description |
0x0000 | Identify |
0x0001 | IdentifyQuery |
Generate command supported:
Command | Description |
0x0000 | IdentifyQueryResponse |
Simple Meter – 0x0702(Server) Attributes supported:
Attribute | Type | Description |
0x0000 | unsigned48, read-only, reportable | CurrentSummationDelivered
Indicates the current amount of electrical energy delivered to the load. |
0x0006 | Int8, read-only | PowerFactor |
0x0200 | bitmap8, read-only | Status
Flags indicating current device status, always is 0x00 |
0x0300 | enum8, read-only | UnitOfMeasure
The unit of measurement data. This is always kWh(0x00) |
0x0301 | Int24U, read-only | Multiplier 1 |
0x0303 | map8, read-only | SummationFormatting 0xF1 |
0x0306 | bitmap8, read-only | MeteringDeviceType
The type of measurement data. This is always Electric Metering (0x00) |
0x0302 | Int24U, read-only | Divisor |
Electrical Measurement – 0x0b04(Server) Attributes supported:
AC: Non – Phase Specific or common attributes supported | ||
Attribute | Type | Description |
0x0000 |
bitmap32, read-only |
MeasurementType
Indicates the physical entities that this device is able to measure. Supports: bit0: Active measurement(AC) bit1: Reactive measurement(AC) bit2: Apparent measurement(AC) bit3~bit5: Phase A, B, C measurement |
0x0300 | int16U,
read-only, reportable |
ACFrequency
Unit is Hz, 0xffff means invalid. |
0x0303 | int16U,
read-only, reportable |
NeutralCurrent Unsigned, unit is A. |
0x0304 | int32S,
read-only, reportable |
Total Active Power Signed, unit is kW. |
0x0305 | int32S,
read-only, reportable |
Total Reactive Power Signed, unit is kVAr. |
0x0306 | int32U,
read-only, reportable |
Total Apparent Power Unsigned, unit is kVA. |
0x0400 | int16U,
read-only, reportable |
ACFrequencyMultiplier 0x01 |
0x0401 |
int16U, read-only, reportable |
ACFrequencyDivisor 0x64 (100)
used together with the above attribute, the actual displayed frequency = ACFrequency* ACFrequencyMultiplier/ ACFrequencyDivisor |
0x0402 | uint32,
read-only, reportable |
PowerMultiplier 0x01 |
0x0403 |
uint32, read-only, reportable |
PowerDivisor 1000
used together with the above attribute, the actual displayed power = [total XX Power]* PowerMultiplier/ PowerDivisor |
0x0600 | int16U,
read-only, reportable |
ACVoltageMultiplier 0x01 |
0x0601 |
int16U, read-only, reportable |
ACVolatgeDivisor 0x0a
used together with the above attribute, the actual displayed voltage = RMSVoltage* ACVoltageMultiplier/ ACVoltageDivisor |
0x0602 | int16U,
read-only, reportable |
ACCurrentMultiplier 0x01 |
0x0603 |
int16U, read-only, reportable |
ACCurrentDivisor (100)
used together with the above attribute, the actual displayed current = RMSCurrent* ACCurrentMultiplier/ ACCurrentDivisor |
0x0604 | int16U,
read-only, reportable |
ACPowerMultiplier 0x01 |
0x0605 |
int16U, read-only, reportable |
ACPowerDivisor 1
used together with the above attribute, the actual displayed power = ActivePower* ACPowerMultiplier/ ACPowerDivisor |
0x0800 |
map16 |
ACAlarmsMask, supports: bit0: Voltage Overload bit1: Current Overload
bit3: Active Power Overload |
0x0801 | int16S,
read-only, reportable |
ACVoltageOverload |
0x0802 | int16S,
read-only, reportable |
ACCurrentOverload |
0x0803 | int16S,
read-only, reportable |
ACActivePowerOverload |
AC: Single Phase or Phase A Attributes supported
Attribute | Type | Description |
0x0505 | int16U,
read-only, reportable |
RMSVoltage
Valid voltage of single phase or phase A, unit is V |
0x0508 | int16U,
read-only, reportable |
RMSCurrent
Valid current of single phase or phase A, unit is A. |
0x050B | int16S,
read-only, reportable |
Active Power
Active power of single phase or phase A, unit is W. |
0x050E | int16,
read-only, reportable |
Reactive Power
Reactive power of single phase or phase A, unit is VAr. |
0x050F | int16U,
read-only, reportable |
Apparent Power
Apparent power of single phase or phase A, unit is VA. |
0x0510 | int8s,
read-only, reportable |
PowerFactor
Power factor of single phase or phase A, unit is 1/100(0.01). |
AC: Phase B Attributes supported
Attribute | Type | Description |
0x0905 | int16U,
read-only, reportable |
RMSVoltagePhB
Valid voltage of phase B, unit is V |
0x0908 | int16U,
read-only, reportable |
RMSCurrentPhB
Valid current of phase B, unit is A. |
0x090B | int16S,
read-only, reportable |
Active PowerPhB
Active power of phase B, unit is W. |
0x090E | int16,
read-only, reportable |
Reactive PowerPhB
Reactive power of phase B, unit is VAr. |
0x090F | int16U,
read-only, reportable |
Apparent PowerPhB
Apparent power of phase B, unit is VA. |
0x0910 | int8s,
read-only, reportable |
PowerFactorPhB
Power factor of phase B, unit is 1/100. |
AC: Phase C Attributes supported
Attribute | Type | Description |
0x0A05 | int16U,
read-only, reportable |
RMSVoltagePhC
Valid voltage of phase C, unit is V |
0x0A08 | int16U,
read-only, reportable |
RMSCurrentPhC
Valid current of phase C, unit is A. |
0x0A0B | int16S,
read-only, reportable |
Active PowerPhC
Active power of phase C, unit is W. |
0x0A0E | int16,
read-only, reportable |
Reactive PowerPhC
Reactive power of phase C, unit is VAr. |
0x0A0F | int16U,
read-only, reportable |
Apparent PowerPhC
Apparent power of phase C, unit is VA. |
0x0A10 | int8s,
read-only, reportable |
PowerFactorPhC
Power factor of phase C, unit is 1/100. |
- OTA Upgrade – 0x0019 (Client) OTA follows the standard Zigbee protocol.
Other private attributes
Cluster | Attributes | Data Type | Data Description | Data Default |
0x0b04 |
0x3e00 |
0x20 |
Metering calibration enable
0: Delete internal calibration value and do not calibrate 1: Enable automatic calibration |
0 |
0x0b04 | 0x3e01 | 0x21 | Measure voltage calibration value | 0 |
0x0b04 | 0x3e02 | 0x21 | Measure current calibration value | 0 |
0x0b04 | 0x3e03 | 0x21 | Measure power calibration value | 0 |
Application Endpoint #242 – GreenPower
Wiring
- Three-phase wiring way
- Mono-phase wiring way
Terminals Introduction
- A: Phase A and power supply input B: Phase B input
- C: Phase C input
- N: Neutral terminal
- IA: Phase A current transformer input
- IB: Phase B current transformer input
- IC: Phase C current transformer input
- IN: Neutral current transformer input
- LA: Phase A live (110-240 V) wire
- LB: Phase B live (110-240 V) wire
- LC: Phase C live (110-240 V) wire
- N: Neutral terminal
- L: Mono-phase live (110-240 V) wire
- N: Neutral wire
Note:
- To obtain a value for the combined phase power, one of the phases A, B, or C must be connected.
- The direction of the combined phase current transformer can be ignored, but the A, B, and C phase current transformers have a specific direction when clamped to the lines.
- If the direction is reversed, the active power and power factor will be negative. The current direction for wiring should pass through the current transformer in the S1->S2 direction, as shown in the following figure:
FAQs
Q: What is the power consumption range of the power meter?
A: The power meter is designed for a power input range of 100-240Vac.
Q: How do I reset the device to factory settings?
A: Press and hold the Reset Key on the device for 10 seconds to perform a factory reset.