Zigbee SR-ZG9042MP Three Phase Power Meter

Zigbee-SR-ZG9042MP-Three-Phase-Power-Meter-product

Specifications

  • Product Name: ZigBee Three-Phase Power Meter
  • Power Input: 100-240Vac
  • Dimensions: 18mm x 66mm
  • Reset Key: Allows for factory reset of the device

Product Usage Instructions

Installation

  1. Ensure that the power meter is compatible with your power input range (100-240Vac).
  2. Locate a suitable location to install the power meter, ensuring it is easily accessible.
  3. Connect the power meter to the power source using the appropriate cables.
  4. Secure the power meter in place using screws or mounting brackets.

Functionality

  • The ZigBee Three-Phase Power Meter allows you to monitor and track power consumption across three phases (A, B, C).

Resetting the Device

  • To perform a factory reset of the device, press and hold the Reset Key for 10 seconds. This will restore the power meter to its default settings.

Important:

  • Read All Instructions Before Installation

Function introduction

Zigbee-SR-ZG9042MP-Three-Phase-Power-Meter-fig-1

Product Data

Input Voltage Power Consumption Ammeters Voltmeters accuracy Ammeters accuracy Size(LxWxH)
100-240VAC <3W 0-200A ±1 % ±1 % (2 – 200 A),

±2 % (1 – 2 A), ±5 % (0 – 1 A)

90x66x18mm
  • Precise 3-phase energy metering based on the latest ZigBee 3.0 protocol
  • 4 Quadrant measurement
  • Up to 200A per phase
  • Solar and Wind power compatible
  • Factory calibrated with over 99% accuracy
  • Multiple connection types
  • Current transformer connection
  • DIN mountable

Power and energy meters:

  1. Active and apparent power
  2. Active and apparent energy
  3. Power factor
  4. Fundamental active and fundamental reactive energy

Safety & Warnings

  • DO NOT install with power applied to the device.
  • DO NOT expose the device to moisture.

Operation

Join Zigbee Network

Step 1:

  • Operate your ZigBee Controller (Gateway) to add a device.

Step 2:

  • Press the button on the device 5 times continuously.
  • If the device is not connected to a network, it will directly enter network paring mode, the LED will flash quickly;
  • If connected to a network, it will automatically exit the network, the LED will flash 3 times to indicate a successful network exit. After a few seconds, the device will automatically enter network pairing mode, the LED will flash quickly.

Step 3:

  • Wait for this process to finish. If the connection is successful, the LED will flash 3 times, otherwise the LED will go off.
  • Re-powering the device: if the LED flashes quickly, the device isn’t connected to a network; Otherwise, it has been connected to a network.
  • When the device is working properly, the LED flashes slowly with a frequency of 1s. When EEPROM reading is abnormal, the LED flashes once within 1.5s.

Exit ZigBee Network

Method 1:

  • Operate your gateway to delete the device, the LED will flash 3 times to indicate a successful network exit. Method 2: Press the button on the device 5 times continuously, the LED will flash 3 times to indicate a successful network exit.

Factory Reset

  • Long press the button for over 10s, the LED will flash slowly then stay on for 3s to indicate a successful reset.

Note:

  • After the device exits the Zigbee network, the device’s bind table will be cleared. Electrical consumption data will not be cleared unless the device is restored to factory settings or receives a “Reset to Factory Defaults Command” after being added to the network.

Zigbee Interface

Zigbee application endpoints:

Endpoint Profile Application
0(0x00) 0x0000(ZDP) ZigBee Device Object (ZDO) – standard management features
1(0x01) 0x0104(HA) Simple sensor, DeviceID = 0x000C
242 0x0104(HA) Green power, DeviceID = 0x0301
  • Application Endpoint #0-ZDO Device standard management features.

Application endpoint #1-Thermostat

Cluster Supported Description
 

0x0000

 

Server

Basic

Provides basic information about the device, such as the manufacturer ID, vendor and model name, stack profile, ZCL version, production date, hardware revision etc. Allows a factory reset of attributes, without the device leaving the network.

 

0x0003

 

Server

Identify

Allows to put the endpoint into identify mode. Useful for identifying/locating devices and required for Finding & Binding.

 

0x0004

 

Server

Groups

Allows adding this endpoint to one or more groups. Afterwards the endpoint can be addressed using the group address. This is also a prerequisite for scenes. You may also query group membership and delete group associations.

 

0x0005

 

Server

Scenes

Allows storing one or more scenes per group, where each scene consists of a pre-set on/off state value. You may either store the current values as a scene, or provide scene settings when adding a scene, or delete scenes.

0x0B04 Server Electrical Measurement
0x0702 Server Simple Meter
 

0x0019

 

Client

OTA Upgrade

Pull-oriented firmware upgrade. Searches the network for mating servers and allows the

server to control all stages of the upgrade process, including which image to download, when to download, at what rate and when to install the downloaded image.

Basic – 0x0000(Server) Attributes supported:

Attribute Type Description
0x0000 INT8U, read-only ZCLVersion
0x0001 INT8U, read-only ApplicationVersion
0x0002 INT8U, read-only StackVersion
0x0003 INT8U, read-only HWVersion
0x0004 string, read-only ManufacturerName
0x0005 string, read-only ModelIdentifier
0x0006 string, read-only DateCode NULL
0x0007 ENUM8, read-only PowerSource

The type of power source for the device. Fixed value: 0x01 Mains (single phase)

0x0008 ENUM8, read-only GenericDevice-Class 0XFF
0x0009 ENUM8, read-only GenericDevice-Type 0XFF
0x000A octstr, read-only ProductCode 00
0x000B string, read-only ProductURL NULL
0x4000 string, read-only Sw build id 6.10.3.0

Command supported:

Command Description
 

0x00

Reset to Factory Defaults Command

On receipt of this command, the device resets all the attributes of all its clusters to their factory defaults. Note that networking functionality, bindings, groups, or other persistent data are not affected by this command.

Identify – 0x0003(Server)

Attributes supported:

Attribute Type Description
0x0000 Int16U Identify time

Receive command supported:

Command Description
0x0000 Identify
0x0001 IdentifyQuery

Generate command supported:

Command Description
0x0000 IdentifyQueryResponse

Simple Meter – 0x0702(Server) Attributes supported:

Attribute Type Description
0x0000 unsigned48, read-only, reportable CurrentSummationDelivered

Indicates the current amount of electrical energy delivered to the load.

0x0006 Int8, read-only PowerFactor
0x0200 bitmap8, read-only Status

Flags indicating current device status, always is 0x00

0x0300 enum8, read-only UnitOfMeasure

The unit of measurement data. This is always kWh(0x00)

0x0301 Int24U, read-only Multiplier 1
0x0303 map8, read-only SummationFormatting 0xF1
0x0306 bitmap8, read-only MeteringDeviceType

The type of measurement data. This is always Electric Metering (0x00)

0x0302 Int24U, read-only Divisor

Electrical Measurement – 0x0b04(Server) Attributes supported:

AC: Non – Phase Specific or common attributes supported
Attribute Type Description
 

 

0x0000

 

 

bitmap32, read-only

MeasurementType

Indicates the physical entities that this device is able to measure. Supports: bit0: Active measurement(AC)

bit1: Reactive measurement(AC) bit2: Apparent measurement(AC)

bit3~bit5: Phase A, B, C measurement

0x0300 int16U,

read-only, reportable

ACFrequency

Unit is Hz, 0xffff means invalid.

0x0303 int16U,

read-only, reportable

NeutralCurrent Unsigned, unit is A.
0x0304 int32S,

read-only, reportable

Total Active Power Signed, unit is kW.
0x0305 int32S,

read-only, reportable

Total Reactive Power Signed, unit is kVAr.
0x0306 int32U,

read-only, reportable

Total Apparent Power Unsigned, unit is kVA.
0x0400 int16U,

read-only, reportable

ACFrequencyMultiplier 0x01
 

0x0401

 

int16U,

read-only, reportable

ACFrequencyDivisor 0x64 (100)

used together with the above attribute, the actual displayed frequency = ACFrequency* ACFrequencyMultiplier/ ACFrequencyDivisor

0x0402 uint32,

read-only, reportable

PowerMultiplier 0x01
 

0x0403

 

uint32,

read-only, reportable

PowerDivisor 1000

used together with the above attribute, the actual displayed power = [total XX Power]* PowerMultiplier/ PowerDivisor

0x0600 int16U,

read-only, reportable

ACVoltageMultiplier 0x01
 

0x0601

 

int16U,

read-only, reportable

ACVolatgeDivisor 0x0a

used together with the above attribute, the actual displayed voltage = RMSVoltage* ACVoltageMultiplier/ ACVoltageDivisor

0x0602 int16U,

read-only, reportable

ACCurrentMultiplier 0x01
 

0x0603

 

int16U,

read-only, reportable

ACCurrentDivisor (100)

used together with the above attribute, the actual displayed current = RMSCurrent* ACCurrentMultiplier/ ACCurrentDivisor

0x0604 int16U,

read-only, reportable

ACPowerMultiplier 0x01
 

0x0605

 

int16U,

read-only, reportable

ACPowerDivisor 1

used together with the above attribute, the actual displayed power = ActivePower* ACPowerMultiplier/ ACPowerDivisor

 

0x0800

 

map16

ACAlarmsMask, supports: bit0: Voltage Overload bit1: Current Overload

bit3: Active Power Overload

0x0801 int16S,

read-only, reportable

ACVoltageOverload
0x0802 int16S,

read-only, reportable

ACCurrentOverload
0x0803 int16S,

read-only, reportable

ACActivePowerOverload

AC: Single Phase or Phase A Attributes supported

Attribute Type Description
0x0505 int16U,

read-only, reportable

RMSVoltage

Valid voltage of single phase or phase A, unit is V

0x0508 int16U,

read-only, reportable

RMSCurrent

Valid current of single phase or phase A, unit is A.

0x050B int16S,

read-only, reportable

Active Power

Active power of single phase or phase A, unit is W.

0x050E int16,

read-only, reportable

Reactive Power

Reactive power of single phase or phase A, unit is VAr.

0x050F int16U,

read-only, reportable

Apparent Power

Apparent power of single phase or phase A, unit is VA.

0x0510 int8s,

read-only, reportable

PowerFactor

Power factor of single phase or phase A, unit is 1/100(0.01).

AC: Phase B Attributes supported

Attribute Type Description
0x0905 int16U,

read-only, reportable

RMSVoltagePhB

Valid voltage of phase B, unit is V

0x0908 int16U,

read-only, reportable

RMSCurrentPhB

Valid current of phase B, unit is A.

0x090B int16S,

read-only, reportable

Active PowerPhB

Active power of phase B, unit is W.

0x090E int16,

read-only, reportable

Reactive PowerPhB

Reactive power of phase B, unit is VAr.

0x090F int16U,

read-only, reportable

Apparent PowerPhB

Apparent power of phase B, unit is VA.

0x0910 int8s,

read-only, reportable

PowerFactorPhB

Power factor of phase B, unit is 1/100.

AC: Phase C Attributes supported

Attribute Type Description
0x0A05 int16U,

read-only, reportable

RMSVoltagePhC

Valid voltage of phase C, unit is V

0x0A08 int16U,

read-only, reportable

RMSCurrentPhC

Valid current of phase C, unit is A.

0x0A0B int16S,

read-only, reportable

Active PowerPhC

Active power of phase C, unit is W.

0x0A0E int16,

read-only, reportable

Reactive PowerPhC

Reactive power of phase C, unit is VAr.

0x0A0F int16U,

read-only, reportable

Apparent PowerPhC

Apparent power of phase C, unit is VA.

0x0A10 int8s,

read-only, reportable

PowerFactorPhC

Power factor of phase C, unit is 1/100.

  • OTA Upgrade – 0x0019 (Client) OTA follows the standard Zigbee protocol.

Other private attributes

Cluster Attributes Data Type Data Description Data Default
 

0x0b04

 

0x3e00

 

0x20

Metering calibration enable

0: Delete internal calibration value and do not calibrate 1: Enable automatic calibration

0
0x0b04 0x3e01 0x21 Measure voltage calibration value 0
0x0b04 0x3e02 0x21 Measure current calibration value 0
0x0b04 0x3e03 0x21 Measure power calibration value 0

Application Endpoint #242 – GreenPower

Wiring

  1. Three-phase wiring way
  2. Mono-phase wiring way

Zigbee-SR-ZG9042MP-Three-Phase-Power-Meter-fig-2

Terminals Introduction

  • A: Phase A and power supply input B: Phase B input
  • C: Phase C input
  • N: Neutral terminal
  • IA: Phase A current transformer input
  • IB: Phase B current transformer input
  • IC: Phase C current transformer input
  • IN: Neutral current transformer input
  • LA: Phase A live (110-240 V) wire
  • LB: Phase B live (110-240 V) wire
  • LC: Phase C live (110-240 V) wire
  • N: Neutral terminal
  • L: Mono-phase live (110-240 V) wire
  • N: Neutral wire

Note:

  • To obtain a value for the combined phase power, one of the phases A, B, or C must be connected.
  • The direction of the combined phase current transformer can be ignored, but the A, B, and C phase current transformers have a specific direction when clamped to the lines.
  • If the direction is reversed, the active power and power factor will be negative. The current direction for wiring should pass through the current transformer in the S1->S2 direction, as shown in the following figure:

Zigbee-SR-ZG9042MP-Three-Phase-Power-Meter-fig-3

FAQs

Q: What is the power consumption range of the power meter?
A: The power meter is designed for a power input range of 100-240Vac.

Q: How do I reset the device to factory settings?
A: Press and hold the Reset Key on the device for 10 seconds to perform a factory reset.