Zigbee 1CH Switch Module-L Instruction Manual

Zigbee 1CH Switch Module L - Featured Image

Zigbee logoINSTRUCTION MANUAL
Zigbee Switch Module-L
1CH,2CH,3CH,4CH
(No Neutral Wire Required)

1CH Switch Module-L

Zigbee 1CH Switch Module L - PartsZigbee 1CH Switch Module L - Symbol 1

TECHNICAL SPECIFICATIONS

Product type Zigbee Switch Module-L
Voltage AC200-240V 50/60Hz
Max. load 1CH: 10-100W
2CH: 2x (10-100W)
3CH: 3x (10-100W)
4CH: 4x (10-100W)
Operation frequency 2.405GHz-2.480GHz
Operation temp. -10℃ + 40℃
Protocol IEEE802.15.4
Operation range <100m
Dims (WxDxH) 39.2×39.2×18 mm
IP rating IP20
Warranty 2years
Certificates CE ROHS

with a mounting clip

Zigbee 1CH Switch Module L - with mounting clip

INSTALLATION

Zigbee 1CH Switch Module L - Symbol 2 Warnings:

  1. Installation must be carried out by a qualified electrician in accordance with local regulations.
  2. Keep the device out of reach of children.
  3. Keep the device away from water, damp or hot environments.
  4. Install the device away from strong signal sources such as microwave ovens that may cause signal interruption, resulting to abnormal operation of the device.
  5. Obstruction by a concrete wall or metallic materials may reduce the effective operation range of the device and should be avoided.
  6. Do NOT attempt to disassemble, repair, or modify the device.

FAQ

Q1: What should I do if I can’t configure the switch module?

a. Please check whether the device is powered on. b. Make sure the Zigbee Gateway is available. c. Whether it’s in good internet conditions. d. Make sure the password entered in App is correct. e. Make sure the wiring is correct.

Q2: What device can be connected to this Zigbee switch module?

such as a ceiling lamp, panel light, etc.

Q3: What happens if the WIFI goes off?

You can still control the device connected to the switch module with your traditional switch, and once WIFI is active again, the device connected to the module will connect automatically to your WIFI network.

Q4: What should I do if I change the WIFI network or change the password?

You have to reconnect our Zigbee switch module to the new Wi-Fi network accordingly, as per the App User

Q5: How do I reset the device?

1. Switch on/off the traditional switch 5 times until the indicator light flashes. 2. Press the reset key for about 10 seconds until the indicator light flashes.

Wiring Instructions and Diagrams

  1. Turn off the power supply before carrying out any electrical installation work.
  2. Connect wires according to the wiring diagram.
  3. Insert the module into the junction box.
    Turn on the power supply and follow the switch module configuration instructions.
  4. Flash after the lights are off. Please attach accessories.

Zigbee 1CH Switch Module L - Symbol 2 Warnings: Do not connect the neutral line; otherwise, it will be permanently damaged.

Zigbee 1CH Switch Module L - Wiring diagram of fittings

1CH Zigbee Switch Module-L

Zigbee 1CH Switch Module L - 1CH Zigbee Switch Module-L

2CH Zigbee Switch Module-L

Zigbee 1CH Switch Module L - 2CH Zigbee Switch Module-L

Wiring diagram of fittings(L1 L2 One of them)

Zigbee 1CH Switch Module L - Wiring diagram of fittings 2

3CH Zigbee Switch Module-L

Zigbee 1CH Switch Module L - 3CH Zigbee Switch Module-L

Wiring diagram of fittings (L1 L2 L3 One of them)

Zigbee 1CH Switch Module L - Wiring diagram of fittings 3

4CH Zigbee Switch Module-L

Zigbee 1CH Switch Module L - 4CH Zigbee Switch Module-L

APP USER MANUALZigbee 1CH Switch Module L - QR Codehttp://smart.tuya.com/download

IOS APP / Android APP
Scan the QR code to download the Tuya Smart App, or you can also search the keyword “Tuya Smart” on App Store or Google Play to download the App.
Log in or register your account with your mobile number or e-mail address. Type in the verification code sent to your mobile or email, then set your login password. Click “Create Family” to enter the APP.

Zigbee 1CH Switch Module L - Open the control panelOpen the control panel of the ZigBee gateway on the App
Before making the reset operation, pls make sure the Zigbee Gateway is added and installed to the WIFI network. Ensure that the product is within the range of the Zigbee Gateway Network.

Zigbee 1CH Switch Module L - Zigbee Gateway

After the wiring of the switch module is done, press the reset key for about 10 seconds or turn on/off the traditional switch 5 times until the indicator light inside the module is flashing quickly for pairing.

Zigbee 1CH Switch Module L - Add sub-device

Click “+” (Add sub-device) to select the suitable product gateway and follow the on-screen instructions for pairing.

Zigbee 1CH Switch Module L - connecting will take about

The connection will take about 10-120 seconds to complete, depending on your network conditions.
Finally, you can control the device via your mobile phone.

SYSTEM REQUIREMENTS
WIFI® Router
ZigBee gateway
iPhone, iPad (iOS 7.0 or higher)
Android 4.0 or higher

Zigbee 1CH Switch Module L - SYSTEM REQUIREMENTS

Zigbee logo

Documents / Resources

PDF thumbnail1CH Switch Module-L
Instruction Manual · 1CH Switch Module-L, Switch Module-L, Module-L

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.