  • The indoor unit should be installed in a location that meets the following requirements:
  • There is enough room for installation and maintenance.
  • The ceiling is horizontal and can endure the weight of the indoor unit.
  • The outlet and inlet are unobstructed with minimal external air influence.
  • The airflow can reach throughout the room.
  • The connecting pipe and drain pipe can be easily extracted.
  • Avoid direct radiation from heaters.
  • Brand-new panel design for uniform, simple appearance suitable for various settings.
  • Ultra-thin body design with a minimum height of 230mm to save installation space.
  • Round-way air flow for even cooling throughout the room.
  • Intelligent auto-swing function with three modes to choose from.
  • 3-speed fan motor to meet different requirements.
  • Energy-saving with hydrophilic aluminum fins for increased heat exchange efficiency.

General information

Model Names

Indoor units

Model name Dimension (W×H×D) (mm) Net/Gross weight (kg) Power supply
Round-flow Cassette
standard
BCC36B13R 840×230×840 28/32 208~230V/1Ph/60Hz
BCC60B13R 840×285×840 31/35 208~230V/1Ph/60Hz

External Appearance

Indoor Units

ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-1

Features

  1. High-quality coils
    The coil is constructed of advanced inner grooved copper tube and aluminum fins.ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-2
  2. Low operation sound level: Well-known stable and quiet running fan motor.
  3. Well-known compressor, Sanyo & Hitachi.
  4. Compact design: Smaller dimension and larger staffing capacity.
  5. Universal outdoor unit design.

Features

  1. Brand-new panel design. Indoor units use uniform panels, simple and convenient.
    Simple, featly and voguish appearance suit for different requirements, it’s mostly used for office, shopping center, restaurant, meeting room, etc.ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-3
  2. Ultra-thin body design, the min. height is only 230mm, save installation space.ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-4
  3. Roundway air flow, cool air can reach each corner of the room, providing a comfortable environment.
  4. Intelligentauto-swing function, three modes for choice.ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-5
  5. 3The-speed fan motor meets different requirements.ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-6
  6. Energy saving and healthy, adopting hydrophilic aluminum fins increasing heat-exchange efficiency.ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-7
  7. Easy and convenient installation and maintenance, washable filter design.ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-8
  8. Built-in water pump, water head up to 1200mm (Compact type, 700mm).ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-9
  9. Fire resistance design, the E-box with galvanized steel built-in body is easy for maintenance.ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-10
  10. Add 4 interfaces in the body, which can be connected with a duct to another room. Fresh air makes air quality healthier and more comfortable.ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-11
  11. Multi-protection and auto-restart function.
  12. The standard for the wireless controller; option for the wired controller.

ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-12

Specifications

Model BCC36B13R BCC60B13R
Code 821028900052 821030100026
Indoor power supply V/Ph/Hz 208~230/1/60 208~230/1/60
Cooling  

Capacity

Btu/h 36000 60000
W 10548 17580
Input W 4125 6912
Rated current A 17.5 29.23
Input(Indoor unit) W 150 180
Rated current(Indoor unit) A 0.7 0.8
EER W/W 2.56 2.54
Indoor fan motor Brand Kaibang Kaibang
Model YDK-45Q-8P2 YDK-80Q-8P2
Input W 102 160
Capacitor μF 2.5 4
Speed(Hi/Me/Lo) r/min 850/730/580 800/750/650
Indoor coil Number of rows 2 2
Tube pitch(a)xrow pitch(b) mm 21×13.37 21×13.37
Fin spacing mm 1.45 1.45
Fin type Hydrophilic Hydrophilic
 

Tube outside dia. and type

 

mm

Ф7 Ф7
inner grooved inner grooved
Number of circuits 8 12
Indoor air flow(High speed) m3/h 1200 1900
Indoor noise level dB(A) 45~52 51~57
Indoor unit Dimension(W*D*H) Body (mm) 840×840×230 840×840×285
Panel

(mm)

950×950×50 950×950×50
Packing(W*D*H) Body (mm) 920×920×310 920×920×375
Panel

(mm)

1030×1030×105 1030×1030×105
Net/Gross weight Body

/Kg

28/32 31/35
Panel

/Kg

5.4/8.0 5.4/8.0
Max pressure MPa 4.0 4.5
Refrigerant type R410A R410A
Refrigerant piping Liquid side/Gas side mm Φ9.52/Φ19.05 Φ9.52/Φ19.05
Drainage pipe mm 25 25
Standard controller  
Operation temp °C 16~32 16~32
Ambient temp °C 18~43 18~43
Application area m2 40-70 60~105
Stuffing Quantity(20’/40’/40’HQ) set 65/130/150 65/130/150

Notes

  1. Nominal cooling capacities are based on the following conditions:
    Indoor temp: 27°CDB, 19°CWB; Outdoor temp: 35°CDB; Equivalent ref. piping: 7.5m (horizontal)
  2. Nominal heating capacities are based on the following conditions:
    Indoor temp: 20°CDB; Outdoor temp: 7°CDB, 6°CWB; Equivalent ref. piping: 7.5m (horizontal)
  3. Actual noise levels may differ, depending on the room structure, etc, since these noise values are from an anechoic room.

Dimensions

ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-13 ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-14

Service Space

The indoor unit should be installed in a location that meets the following requirements:

  • There is enough room for installation and maintenance.
  • The ceiling is horizontal, and its structure can endure the weight of the indoor unit.
  • The outlet and the inlet are not impeded, and the influence of external air is the least.
  • The air flow can reach throughout the room.
  • The connecting pipe and drainpipe could be extracted out easily.
  • There is no direct radiation from heaters.

ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-15

Wiring Diagrams

BCC36B13R

ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-16

BCC60B13R

ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-17

Electric Characteristics

Model Indoor Unit
Hz Voltage Min. Max.
BCC36B13R 60 208-230V 187V 244V
BCC60B13R 60 208-230V 187V 244V

Remark:

  • MCA: Min. Current Amps. (A)
  • MFA: Max. Fuse Amps. (A)

Sound Levels

ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-18

Model Noise level dB(A)
H M L
BCC36B13R 52 48 45
BCC60B13R 57 54 51

Accessories

ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-19

Exploded View

BCC36B13R / BCC60B13R

ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-20

No. Part Name Quantity No. Part Name Quantity
1 Warning panel 1 8.3.4 Installation tube for probe 1
2 Circuit diagram panel 1 9 Water pump 1
3 Small wind inlet guide 1 10 Liquid-level sensor 1
4 E-parts components 1 11 Water pump fan motor holder 1
4.1 E-parts box welding assy 1 12 Underlay for water pump support 3
4.2 No.3 groove clamp 1 13 Upper foam 1
4.3 (ROHS)Transformer 1 14 Centrifugal fan 1
4.4 Fan motor capacitor 1 15 Hanger 4
4.5 Terminal (DJ-75W-3PA) 1 16 Rear brattice 1
4.6 Terminal (DJ-75W-5PA) 1 17 Fan motor for the indoor unit (YDK-55T- 6) 1
4.7 Electric control board for indoor unit 1 17.1 Fan motor foot underlay 1
4.8 E-parts box 1 18 Chassis assy 1
5 Water pan assy 1 19 Right clapboard 1
6 Auxiliary fixing board for evaporator 2 20 Front brattice 1
7 Main fixing board assy 1 21 Discharge pipe joint 1
7.1 Main fixing board for evaporator 1 22 Side maintenance board for water pump 1
8 Evaporator components 1 23 Lower clamp 1
8.1 Rubber insulating pipe 1 24 Upper clamp 1
8.2 Insulating pipe 1 25 Valve panel 1
8.3 Welding parts for evaporator 1 26 Wire board 2
8.3.1 Collecting pipe assy for evaporator 1 27 Left clapboard 1
8.3.2 Distributing pipe assy for evaporator 1 28 Water outlet pipe 1
8.3.3 Evaporator 1      

Field Wiring
BCC36B13R

ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-21

BCC60B13R

ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-22

Troubleshooting

Fault Code Table

ZenAire-BCC36B13R-4-Way-Cassette-Mini-Splits-fig-23

E0: Indoor unit and outdoor unit communication failure Solution:

  1. Check the communication cable between the indoor unit and the outdoor unit, if it is a short connection or broken;
  2. Check whether the communication cable is connected corrected or not, if not, correct it;
  3. If the cable and connection are both correct, check the connected lines from the communication terminal to the main board are corrected or not, if not, correct it
  4. If all the above steps are done, still not solved change the indoor or outdoor main board

E1: Outdoor unit failure

  • Check the details of the failure at the outdoor unit.

E2: Indoor ambient temp. sensor fault (T1 sensor) Solution:

  1. Check the T1 sensor connection is loosened or not, and inset it firmly, if not solved, go to next step;
  2. Take out the sensor, and measure the resistance of the sensor, it is about 5KΩ at 25℃, if not, replace it; if resistance normally, change the indoor main board.

E3: Indoor evaporator pipe temperature sensor (T2) failure Solution:

  1. Check the T2 sensor connection is loosened or not, and inset it firmly, if not solved, go to next step;
  2. Take out the sensor, and measure the resistance of the sensor, it is about 5KΩ at 25℃, if not, replace it; if the resistance is normal, change the indoor main board

E5: Condenser pipe temperature sensor (T3) failure Solution:

  1. Check the T3 sensor connection is loosened or not, and inset it firmly, if not solved, go to next step;
  2. Take out the sensor, and measure the resistance of the sensor, it is about 5KΩ at 25℃, if not, replace it; if the resistance is normal, change the main board

F2: Outdoor unit protection

  • Solution:
  • Follow the F3/F4/F8/F9.

F3: High pressure protection
Solution:

  1. If the unit does not have a high-pressure switch, change the outdoor main board; if it has, go to next step
  2. Take out the high-pressure switch, and measure its resistance, it is about 0Ω, if not, replace it; otherwise, go to next step;
  3. Short-connect the high-pressure switch port on the outdoor board, if it still shows P1, replace the outdoor main board; otherwise, go tothe  next step;
  4. Connect the pressure gauge to test the high pressure, if it is really too high, may be caused by too much refrigerant or other gas getting inside the system

F4: Low pressure protection
Solution:

  1. If the unit does not have a low-pressure switch, change the outdoor main board; if it has, go to the next step
  2. Take out the low-pressure switch, measure its resistance, and confirm whether it is about 0Ω, if not, replace it; otherwise, go to the next step;
  3. Short-connect the low-pressure switch port on the outdoor board, if it still shows P2, replace the outdoor main board; otherwise, go to the next step;
  4. Connect the pressure gauge to test the low pressure, if it is really too low, may be caused by a lack of refrigerant or leakage in the refrigerant system

F5: Water fulfilled protection (Alarm of condensing water overflow)
Solution:

  1. If the unit does not have a water drainage pump:
    • a) Check whether the water level switch short short-connected or not, if not, short-connect it, if it is still not solved, change the main board
  2. If the unit has a water drainage pump:
    • a)Check the water level switch if it is connected well, inset it firmly; then check if the switch is blocked or not, if it is blocked, replace it, otherwise go to the next step
    • b) Check the connection between the pump and the main board if it is 220-240V, if it is, change the water pump; if not, change the indoor main board

F7:Ourdoor overcurrent protection
Solution:

  1. Check the dial switches is setting corrected or not according to the wiring diagram, if not, set it corrected; if correct, go to the next step
  2. Check the condenser whether it is in good ventilation, if not, remove the blockage; otherwise, go to the next step.
  3. Measure the current with a multimeter, and check the current via the unit check data also, compare these two data, if they are quite different, change the outdoor main board;
  4. If all the above steps are done normally, it may cause the damaged compressor or refrigerant system blocked or dirty or other gas to get inside the system

F8: Outdoor unit exhaust temperature over-high protection
Solution:

  1. Check whether the T5 sensor connection is loosened or not, and  inset it firmly, if not solved, go to next step;
  2. Take out the exhaust sensor (T5) from the main board, and measure its resistance, it is about 50KΩ at 25℃, if not, change the sensor; if it is, go to the next step
  3. Remove the sensor from the compressor, if it is still not solved, change the main board
  4. If all the above steps are done normally, it may be caused lack of refrigerant or damaged compressor or refrigerant system being blocked or dirty or other gas get inside the system.

F9: Three-phase electricity power phase sequence failure
Solution:

  1. Check whether the 3-phase power connection lines are connected well or not
  2. Using the meter to measure the voltage (L1&N, L2&N, L3&N), all of them should be 220V, if not, correct the power supply, otherwise go to next step;
  3. If the power supply is corrected, change the main board

P6: EEPROM failure

  • Change the indoor mainboard

FAQ

  • Q: Can this product be connected with ducts to another room?
    • A: Yes, this product has interfaces in the body that can be connected with ducts to another room for improved air quality.
  • Q: What is the minimum height required for installation?
    • A: The minimum height required for installation is only 230mm due to the ultra-thin body design of the unit.
  • Q: Is the wireless controller included with the standard package?
    • A: Yes, a wireless controller is included as standard; however, a wired controller is optional.