1. Ifihan
This manual provides essential instructions for the proper installation, operation, and maintenance of the Protech 61-104025-15 Service Valve. Adhering to these guidelines will ensure safe and efficient performance of the valve. Please read this manual thoroughly before proceeding with any procedures.
2. Ọja Ipariview
The Protech 61-104025-15 Service Valve is a component designed for various industrial and plumbing applications, particularly within HVAC and refrigeration systems. It facilitates isolation and control of fluid flow, allowing for system servicing without complete depressurization or drainage. This valve is compatible with models such as raka, rakb, ralc, rama, ramb, ramc, ramm, ranc, rand, ranl, rapa, rapb, rapc, rapl, rapm, rara, rarl, rasl, rpka, rpkb, rpla, rplb, rpmb, rpmc, rpmd, rpmm, rpne, rpnk, rpnl, rppb, rppc, rppl, rpql, rprl, saka, sakb, spkb.

Nọmba 1: The Protech 61-104025-15 Service Valve. This image displays the brass-colored valve body, featuring two 3/4-inch sweat ODF connections on opposing sides and a hexagonal cap at the top for manual operation.
3. Eto ati fifi sori
Installation of the Protech 61-104025-15 Service Valve requires careful attention to connection types and proper sealing techniques. It is recommended that installation be performed by a qualified technician.
3.1 Asopọmọra alaye
- Upper Connection Size: 3/4 inch
- Upper Connection Type: Sweat ODF (Outer Diameter Flare)
- Lower Connection Size: 3/4 inch
- Lower Connection Type: Sweat ODF (Outer Diameter Flare)
3.2 Ilana fifi sori ẹrọ
- Aabo Lakọkọ: Rii daju pe eto naa jẹ irẹwẹsi ati imugbẹ ṣaaju ki o to bẹrẹ fifi sori ẹrọ. Wọ ohun elo aabo ti ara ẹni ti o yẹ (PPE).
- Mura awọn isopọ: Clean the ends of the pipes and the valve's sweat connections thoroughly to remove any dirt, grease, or oxidation. Apply appropriate flux to both surfaces.
- Gbe àtọwọdá naa si ipo: Place the valve in the desired position, ensuring proper alignment with the piping.
- Awọn isopọ Solder: Using a suitable heat source and solder, create strong, leak-free sweat joints. Allow the joints to cool naturally.
- Idanwo Leki: After installation, pressurize the system and carefully check all connections for leaks using an approved leak detection method.
4. Isẹ
The Protech 61-104025-15 Service Valve is designed for straightforward manual operation to control or isolate fluid flow within a system.
4.1 Opening and Closing the Valve
- Si ṣii the valve, turn the hexagonal cap counter-clockwise until the desired flow is achieved or the valve is fully open.
- Si sunmo the valve, turn the hexagonal cap clockwise until the valve is fully closed and flow is stopped. Do not overtighten.
Always operate the valve smoothly and avoid sudden, forceful movements to prevent damage to the valve or system components.
5. Itọju
Regular maintenance ensures the longevity and reliable performance of your Protech 61-104025-15 Service Valve.
- Ayewo Igbakọọkan: Visually inspect the valve and its connections regularly for any signs of wear, corrosion, or leaks.
- Ninu: Keep the exterior of the valve clean. Avoid using harsh chemicals that could damage the valve material.
- Iwari ti o jo: Periodically check for leaks around the valve body and connections, especially after any system pressure changes.
- Ṣíṣàyẹ̀wò Iṣẹ́: Cycle the valve (open and close) periodically to ensure smooth operation and prevent seizing, particularly in systems where the valve remains in one position for extended periods.
6. Laasigbotitusita
This section addresses common issues that may arise with the service valve.
6.1 Wọpọ Oran ati Solusan
| Isoro | Owun to le Fa | Ojutu |
|---|---|---|
| Jijo ni awọn asopọ | Improper soldering; damaged pipe or valve connection | Depressurize system, repair or re-solder connection. Replace valve or pipe if damaged. |
| Àtọwọdá soro lati tan | Internal corrosion or debris; lack of lubrication | Do not force. Depressurize system and inspect. If internal, valve replacement may be necessary. |
| No flow or restricted flow when open | Valve not fully open; internal obstruction | Ensure valve is fully open. Depressurize system and inspect for internal debris. |
Fun awọn ọran ti ko ṣe atokọ tabi ti awọn ojutu ko ba yanju iṣoro naa, kan si onimọ-ẹrọ iṣẹ ti o peye.
7. Awọn pato
| Sipesifikesonu | Ẹ̀kúnrẹ́rẹ́ |
|---|---|
| Brand | ProTech |
| Nọmba awoṣe | 61-104025-15 |
| Upper Connection Size | 3/4 inch |
| Upper Connection Type | Sweat ODF |
| Lower Connection Size | 3/4 inch |
| Lower Connection Type | Sweat ODF |
| Ipari ode | Irin ti ko njepata |
| Nọmba ti Ports | 2 |
| Pato sipesifikesonu | ASME B16.34 |
| Iwọn Nkan | 11.2 iwon |
| Awọn iwọn Ọja (L x W x H) | 3.8 x 3.2 x 4.3 inches |
| UPC | 662766520378 |
8. atilẹyin ọja Information
Unless otherwise noted, all Protech items carry a one-year limited warranty from the date of purchase. Please retain your proof of purchase for warranty claims.
9. Atilẹyin
For technical assistance, replacement parts, or further inquiries regarding the Protech 61-104025-15 Service Valve, please contact a qualified HVAC or plumbing professional. For general product information, you may visit the Ile itaja ProTech lori Amazon.