Characteristics

Suitable for 2000A SCR pulse train trigger.

Technical Index

  • Installation method:PCB
  • Flame resistance :UL94-V0
  • Operation temperature:-20℃~+50℃
  • Storage temperature:-30℃~+85℃
  • Work frequency:1KHz~50KHz
  • Dielectric strength:Pri/Sec 5KV 50Hz 1min Sec/Sec 500V 50Hz 1min

Schematic DiagramYHDC-KMB519-Universal-SCR-Trigger-Transformer-FIG-1

Electrical parameters

(The following parameters are typical values and actual values will be subject to product testing)

Model Parameter KMB519

-101

KMB519

-201

KMB519

-301

KMB519

-111

KMB519

-211

KMB519

-311

Unit
Vout microsecond integral 800 1500 2400 800 1500 2400 μvs
Input pulse amplitude 8 15 24 8 15 24 V
Output pulse amplitude ≥6 ≥5.5 ≥5.5 ≥5×2 ≥5×2 ≥5×2 V
Turns radio 1:1 2:1 3:1 1:1:1 2:1:1 3:1:1  
Load resistance 7 7 7 7 7 7 Ω
duty ratio 1:2 1:2 1:2 1:2 1:2 1:2  
Pulse width 100 100 100 100 100 100 μs
Leading edge time ≤4 ≤4 ≤4 ≤4 ≤4 ≤4 μs
Main circuit operating voltage 660 660 660 660 660 660 V
Weight 19 19 19 19 19 19 g

Dimensions

(in mm±0.5)YHDC-KMB519-Universal-SCR-Trigger-Transformer-FIG-2