Product Information
Specifications:
- Frequency Range: HF/50/144/430MHz
- Mode: All Mode
- Control Interface: CAT (Computer Aided Transceiver) System
- USB Connectivity: USB to Dual UART Bridge
Product Usage Instructions:
CAT Operation:
The CAT (Computer Aided Transceiver) System in the FTX-1 series
transceiver allows control of frequency, VFO, memory, and other
settings using an external personal computer.
Using the USB Cable (CAT-1 / CAT-2):
The FTX-1 transceiver has a built-in USB to Dual UART Bridge for
direct connection to a computer using a USB cable. Follow these
steps:
- Connect the transceiver and PC with a USB cable (type-C).
- Install the Virtual COM port driver from the Yaesu
website. - Confirm successful installation by checking the COM Port Number
in Windows Device Manager.
Communications (Frequency and Communication Mode
Settings):
When configuring software port settings, use the confirmed COM
port numbers for each function. Set frequency, communication mode,
and PTT control from the software. Disable PTT control by RTS or
DTR when using a standard COM port for CAT communication.
FAQ:
How do I update the MAIN firmware for CAT operation?
To update the MAIN firmware to Ver. 1.08 or later for CAT
operation, follow these steps:
- Press and hold the [FUNC] knob.
- Touch [EXTENSION SETTING] on the screen.
- If not displayed, touch [FWD] to show [EXTENSION SETTING] and
then touch it. - Touch [SOFT VERSION] to view firmware versions on the TFT
screen.
How do I confirm successful installation of the Virtual COM
port driver?
To confirm the Virtual COM port driver installation, follow
these steps:
- Turn on the transceiver by pressing and holding the power
switch. - Connect the transceiver and PC with a USB cable.
- Open Windows Device Manager and double-click on Port (COM &
LPT) to view installed COM ports. - Look for Silicon Labs Dual CP210x USB to UART Bridge entries
with COM port numbers for communication.
HF/50/144/430MHz ALL MODE TRANSCEIVER
CAT Operation Reference Manual
Important Notes
The CAT operation does not work with MAIN Firmware before Ver. 1.08. Please update the MAIN firmware to Ver. 1.08 or later. How to Confirm the Firmware Version 1. Press and hold the [FUNC] knob.
2. Touch [EXTENSION SETTING]. If [EXTENSION SETTING] is not displayed, touch [FWD] to display [EXTENSION SETTING] and then touch it.
3. Touch [SOFT VERSION]. The versions of each firmware will be displayed on the TFT screen.
Current MAIN firmware version
CAT (Computer Aided Transceiver) Operation
Overview
The CAT (Computer Aided Transceiver) System in the FTX-1 series transceiver provides control of frequency, VFO, memory, and other settings using an external personal computer. This allows multiple control operations to be fully automated with single mouse clicks, or keystroke operations on the computer keyboard.
YAESU MUSEN does not produce CAT System operating software due to the wide variety of personal computers and operating systems in use today. However, the information provided in this chapter explains the serial data structure and opcodes used by the CAT system. This information, along with the short programming examples, is intended to help you start writing programs on your own. As you become more familiar with CAT operation, you can customize programs for your operating needs and utilize the full operating potential of this system.
Using the USB Cable (CAT-1 / CAT-2)
The FTX-1 transceiver has a built-in USB to Dual UART Bridge, allowing direct connection from the side-panel USB jack to the USB jack of a computer without the need for an interface device, simply use a USB cable to connect to the USB jack on the computer.
PC
To connect to a PC using a USB cable, a Virtual COM port driver must be installed on the PC. Visit the Yaesu website http://www.yaesu.com/ to download the Virtual COM port driver and Installation Manual.
USB
USB Cable USB type-C
FTX-1 field
How to Confirm the Installation, and the COM Port Number After the FTX-1 and computer are connected, confirm that the virtual COM driver has been installed successfully: 1. Press and hold the power switch to turn the transceiver ON. 2. Connect the transceiver and PC with a commercially available USB cable (type-C). 3. Open the “Device Manager” screen in Windows. 4. On the Device Manager screen, double-click “Port (COM & LPT)”.
“Silicon Labs Dual CP210x USB to UART Bridge : Enhanced COM Port (COM**)” “Silicon Labs Dual CP210x USB to UART Bridge : Standard COM Port (COM**)”
*(The number in the “(COM**)” portion may vary from computer to computer.) The above example indicates that COM5 can be used for CAT communications (CAT-1), while COM6 can be used for TX control (PTT, CW Keying, Digital Mode Operation) or CAT communications (CAT-2). When performing software port configuration, select the COM port numbers that were confirmed using the procedure above.
If a “!” or “X” is displayed for the port on the Device Manager, uninstall and reinstall the virtual COM driver.
1
CAT (Computer Aided Transceiver) Operation
The FTX-1 contains two virtual COM ports, an Enhanced COM Port and a Standard COM Port. These ports offer the following functions: · Enhanced COM Port (CAT-1): CAT Communications (Frequency and Communication Mode Settings) · Standard COM Port (CAT-2): TX Controls (PTT control, CW Keying, Digital Mode Operation) or CAT
Communications (Frequency and Communication Mode Settings)*
When performing software port configuration, select the COM port numbers that were confirmed using the procedure above, use the two confirmed COM port numbers for each software function. The frequency and communication mode and PTT control can be set from the software, and CW keying, digital communication, etc. can be performed simultaneously.
*NOTE: (When using a standard COM port (CAT-2) for CAT communication (setting frequency, communication mode, etc.) and using hardware flow control by RTS or DTR, be sure to set the following menu items to “OFF” (factory default) to disable PTT control by RTS or DTR.)
Menu Item RADIO SETTING
CW SETTING PRESET
MODE SSB MODE AM MODE FM MODE DATA MODE RTTY
MODE CW
PRESET1 – 5
Menu Function RPTT SELECT RPTT SELECT RPTT SELECT RPTT SELECT RPTT SELECT RPTT SELECT PC KEYING RPTT SELECT
Available Settings (Default: Bold) OFF / RTS / DTR OFF / RTS / DTR OFF / RTS / DTR OFF / RTS / DTR OFF / RTS / DTR OFF / RTS / DTR OFF / RTS / DTR OFF / RTS / DTR
· If a transceiver with a different serial number is connected and turned on, different COM port numbers will be assigned to it, making it possible to perform individual COM port configurations for separate transceivers.
· When using the USB cable for TX control, the transceiver may switch to the transmit mode when the computer is started.
· Always close the application on the computer before disconnecting the USB cable.
2
CAT (Computer Aided Transceiver) Operation
Using the UART (CAT-3)
The TUNER/LINEAR jack on the rear panel of the FTX-1 field head can be used for CAT communication (5V CMOS level serial communication). Set to “CAT-3” in the setting menu [OPERATION SETTING] [GENERAL] [TUN/LIN PORT SELECT]. (Factory setting: OPTION)
· Since the serial communication of this jack is 5V CMOS level, it cannot be directly connected to the RS-232C terminal of the PC.
· The connection cable must be prepared by yourself using the optional band data cable T9207451A (mini DIN 10-pin to DIN 10-pin).
· CAT communication cannot be used simultaneously with an external antenna tuner or linear amplifier.
+13.8V TX D
GND
RX D
Pin Name +13V GND TXD RXD
I/O Output Input
Function 13 VDC output linked to radio ON
Signal Ground Outputs the Serial Data from the transceiver to the PC (5V TTL) Inputs the Serial Data from the PC to the transceiver (5V TTL)
Communication Parameters
· Asynchronous communication · Baud rate: 38400bps* (CAT-1, CAT-3 terminals) or 4800bps* (CAT-2 terminal) · Start bit: 1 · Data bits: 8 · Stop bits: 1 or 2* (CAT-2: 1 (Fixed)) · Paritybits: None
*(Factory default)
CAT communication settings can be changed using the following menu items.
Menu Item OPERATION SETTING
GENERAL
Menu Function
CAT-1 RATE CAT-1 TIME OUT TIMER CAT-1 CAT-3 STOP BIT CAT-2 RATE CAT-2 TIME OUT TIMER CAT-3 RATE CAT-3 TIME OUT TIMER
Available Settings (Default: Bold) 4800 / 9600 / 19200 / 38400 / 115200 (bps) 10 / 100 / 1000 / 3000 (msec) 1bit / 2bit 4800 / 9600 / 19200 / 38400 / 115200 (bps) 10 / 100 / 1000 / 3000 (msec) 4800 / 9600 / 19200 / 38400 / 115200 (bps) 10 / 100 / 1000 / 3000 (msec)
3
CAT (Computer Aided Transceiver) Operation
Control Command
A computer control command is composed of an alphabetical command, various parameters, and the terminator that signals the end of the control command.
Example: Set the MAIN-side frequency to 14.250000 MHz.
FA
014250000 ;
Command Parameter Terminator
There are three commands for the FTX-1 as shown below:
Set command: Set a particular condition Read command: Reads an answer Answer command: Transmits a condition
(to the FTX-1) (from the FTX-1) (from the FTX-1)
For example, note the following case of the FA command (Set the MAIN-side frequency):
To set the MAIN-side frequency to 14.250000 MHz, the following command is sent from the computer to the transceiver: “FA014250000;” (Set command)
To read the MAIN-side frequency, the following command is sent from the computer to the transceiver: “FA;” (Read command)
When the Read command above has been sent, the following command is returned to the computer: “FA014250000;” (Answer command)
Alphabetical Commands
A command consists of 2 alphabetical characters.
You may use either lower or upper case characters. The commands available for this transceiver are listed in the “PC Control Command Tables” on the following pages.
Parameters
Parameters are used to specify information necessary to implement the desired command.
The parameters to be used for each command are predetermined. The number of digits assigned to each parameter is also predetermined. Refer to the “Control Command List” and the “Control Command Tables” to configure the appropriate parameters.
When configuring parameters, be careful not to make the following mistakes.
For example, when the correct parameter is “IS00+1000” (IF SHIFT):
IS001000; Not enough parameters specified (No direction (+) given for the IF shift)
IS00+100; Not enough digits (Only three frequency digits given)
IS00_+_1000; Unnecessary characters between parameters
IS00+10000; Too many digits (Five frequency digits given)
Note: If a particular parameter is not applicable to the FTX-1, the parameter digits should be filled using any character except the ASCII control codes (00 to 1Fh) and the terminator (;).
Terminator
To signal the end of a command, it is necessary to use a semicolon (;). The digit where this special character must appear differs depending on the command used.
4
CAT (Computer Aided Transceiver) Operation
CAT Control Command List
Command
Function
Set Read Ans. AI
AB MAIN-side to SUB-side
AC
ANTENNA TUNER CONTROL
AG AF GAIN
OXXX OOOO OOOO
AI
AUTO INFORMATION
AM
MAIN-side to MEMORY CHANNEL
AO AMC OUTPUT LEVEL
OOOX OXXX OOOO
BA SUB-side to MAIN-side
OXXX
BC AUTO NOTCH (DNF)
OOOO
BD BAND DOWN
OXXX
BI
BREAK-IN
BM
SUB-side to MEMORY CHANNEL
BP
MANUAL NOTCH
OOOO OXXX OOOO
BS
BAND SELECT
OXXX
BU BAND UP
OXXX
CF CLAR (Clarifier)
OOOO
CH CHANNEL UP/DOWN
OXXX
CN CTCSS NUMBER
OOOO
CO CONTOUR/APF
OOOO
CS
CW SPOT
OOOO
CT CTCSS
OOOO
DA LCD CONTRAST/DIMMER O O O X
DN DOWN
OXXX
DT
DATE AND TIME
OOOX
EX MENU
OOOO
FA FREQUENCY MAIN-side
OOOO
FB
FREQUENCY SUB-side
OOOO
FN FINE TUNING
OOOO
FR
FUNCTION RX
OOOO
FT
FUNCTION TX
OOOO
GP
GP OUT A/B/C/D
OOOX
GT AGC FUNCTION
OOOO
ID
IDENTIFICATION
XOOX
IF
INFORMATION (MAINside)
IS
IF SHIFT
XOOO OOOO
KM KEYER MEMORY
OOOX
KP
KEY PITCH
OOOO
KR KEYER
OOOO
KS
KEY SPEED
OOOO
KY
CW KEYING MEMORY PLAY
LK
LOCK
OXXX OOOO
LM LOAD MESSAGE
MA
MEMORY CHANNEL to MAIN-side
MB
MEMORY CHANNEL to SUB-side
OOOX OXXX OXXX
MC MEMORY CHANNEL
OOOX
MD MODE
OOOO
MG MIC GAIN
OOOO
ML MONITOR LEVEL
OOOO
Command
Function
Set Read Ans. AI
MR MEMORY READ
XOOX
MS METER SW
MT
MEMORY CHANNEL WRITE/TAG
MW MEMORY WRITE
OOOO OOOX OXXX
MX MOX SET
OOOO
MZ SPLIT MEMORY
OOOO
NA NARROW
OOOO
NL
NOISE BLANKER LEVEL
OOOO
OI
OPPOSITE BAND (SUB-side) INFORMATION
X
O
O
O
OS
OFFSET (Repeater Shift)
OOOO
PA
PRE-AMP (IPO)
OOOO
PB
PLAY BACK
OOOX
PC
POWER CONTROL
PL
SPEECH PROCESSOR LEVEL
PR
SPEECH PROCESSOR
OOOO OOOO OOOO
PS
POWER SWITCH
OOOX
QI
QMB STORE
OXXX
QR QMB RECALL
OXXX
RA RF ATTENUATOR
OOOO
RG RF GAIN
OOOO
RI
RADIO INFORMATION
XOOO
RL
NOISE REDUCTION (DNR) LEVEL
O
O
O
O
RM READ METER
XOOO
SC
SCAN
SD
SEMI BREAK-IN DELAY TIME
OOOO OOOO
SF
SUB DIAL
OOOO
SH
WIDTH
OOOO
SM S METER
XOOX
SQ SQUELCH LEVEL
OOOO
SS
SPECTRUM SCOPE
OOOO
ST
SPLIT
OOOO
SV
SWAP VFO
OXXX
TS
TXW
OOOO
TX TX SET
OOOO
UP
UP
OXXX
VD
VOX DELAY TIME
OOOO
VE FIRMWARE VERSION
XOOX
VG VOX GAIN
OOOO
VM [V/M(MW)] KEY FUNCTION O X X X
VM [V/M(MW)] KEY FUNCTION O O O O
VS
VFO SELECT
OOOO
VX VOX
OOOO
ZI
ZERO IN
OXXX
5
CAT (Computer Aided Transceiver) Operation
AB Set Read
MAIN-side to SUB-side
1 2 3 4 5 6 7 8 9 10
AB ;
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Answer
AC
ANTENNA TUNER CONTROL
12345678
Set A C P1 P2 P3 ;
Read
12345678
AC ;
12345678
Answer A C P1 P2 P3 ;
9 10 P1 0: Internal Antenna Tuner (FTX-1 optima) 1: External Antenna Tuner
P2 0: External Antenna Tuner
1: –
2: ATAS
9 10 P3 P2=0 (Antenna Tuner):
0: Tuner “OFF” (Tuning Stop)
1: Tuner “ON”
2: –
9 10
3: Tuning Start P2=2 (ATAS):
0: Tuning Stop
1: Tuning frequency up (50 msec)
2: Tuning frequency down (50 msec)
3: Tuning Start
AG
AF GAIN
Set Read
1 2 3 4 5 6 7 8 9 10 P1 0: MAIN-side
A G P1 P2 P2 P2 ;
1: SUB-side
1 2 3 4 5 6 7 8 9 10 P2 000 – 255
A G P1 ;
1 2 3 4 5 6 7 8 9 10
Answer A G P1 P2 P2 P2 ;
AI
AUTO INFORMATION
1 2 3 4 5 6 7 8 9 10 P1 0: Auto Information “OFF”
Set A I P1 ;
1: Auto Information “ON”
Read
1 2 3 4 5 6 7 8 9 10 NOTES:
AI ;
· When the status of the radio changes, the Read value of the AI applicable command (see “CAT Control Command List” (page 5)) is automatically sent to the PC.
1234
Answer A I P1 ;
5
6
7
8
9 10 · Set ON/OFF for each CAT-1, CAT-2, and CAT-3. · This parameter is set to “0” (OFF) automatically when the transceiver is turned “OFF”.
AM Set Read
MAIN-SIDE TO MEMORY CHANNEL
1 2 3 4 5 6 7 8 9 10
AM ;
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Answer
AO
AMC OUTPUT LEVEL
Set
1 2 3 4 5 6 7 8 9 10 P1 001-100: AMC OUTPUT LEVEL A O P1 P1 P1 ;
Read
1 2 3 4 5 6 7 8 9 10
AO ;
1 2 3 4 5 6 7 8 9 10
Answer A O P1 P1 P1 ;
BA Set Read
SUB-side to MAIN-side
1 2 3 4 5 6 7 8 9 10
BA ;
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Answer
6
CAT (Computer Aided Transceiver) Operation
BC
AUTO NOTCH (DNF)
Set Read
1 2 3 4 5 6 7 8 9 10 P1 0: MAIN-side
B C P1 P2 ;
1: SUB-side
1 2 3 4 5 6 7 8 9 10 P2 0: Auto Notch “OFF”
B C P1 ;
1: Auto Notch “ON”
1 2 3 4 5 6 7 8 9 10
Answer B C P1 P2 ;
BD Set Read
BAND DOWN
1 2 3 4 5 6 7 8 9 10 P1 0: MAIN-side
B D P1 ;
1: SUB-side
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Answer
BI
BREAK-IN
Set
1 2 3 4 5 6 7 8 9 10 P1 0: Break-in “OFF”
B I P1 ;
1: Break-in “ON”
Read
1 2 3 4 5 6 7 8 9 10
BI ;
1 2 3 4 5 6 7 8 9 10
Answer B I P1 ;
BM Set Read
SUB-side to MEMORY CHANNEL
1 2 3 4 5 6 7 8 9 10
BM ;
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Answer
BP
MANUAL NOTCH
12345678
Set B P P1 P2 P3 P3 P3 ;
Read
12345678
B P P1 P2 ;
12345678
Answer B P P1 P2 P3 P3 P3 ;
9 10 P1 0: MAIN-side
1: SUB-side
P2 0: Manual NOTCH “ON/OFF”
9 10
1: Manual NOTCH Frequency
P3 P2=0
000: “OFF”
9 10
001: “ON” P2=1
001 – 320 (NOTCH Frequency : x 10 Hz )
BS
BAND SELECT
Set
1 2 3 4 5 6 7 8 9 10 P1 0: MAIN-side
B S P1 P2 P2 ;
1: SUB-side
Read
1 2 3 4 5 6 7 8 9 10 P2 00: 1.8 MHz 04: 10 MHz 01: 3.5 MHz 05: 14 MHz
1 2 3 4 5 6 7 8 9 10
Answer
02: 5 MHz 03: 7 MHz
06: 18 MHz 07: 21 MHz
08: 24.5 MHz 09: 28 MHz 10: 50 MHz 11: 70 MHz/GEN
12: AIR 13: 144 MHz 14: 430 MHz
BU Set Read
BAND UP
1 2 3 4 5 6 7 8 9 10 P1 0: MAIN-side
B U P1 ;
1: SUB-side
1 2 3 4 5 6 7 8 9 10
Answer 1 2 3 4 5 6 7 8 9 10
7
CAT (Computer Aided Transceiver) Operation
CF Set Read Answer
CLAR ON/OFF
1 2 3 4 5 6 7 8 9 10
C F P1 P2 P3 P4 P5 P6 P7 P8
1 2 3 4 5 6 7 8 9 10
C F P1 P2 P3 ;
1 2 3 4 5 6 7 8 9 10
C F P1 P2 P3 P4 P5 P6 P7 P8
11 P1 0: MAIN-side 1: SUB-side
; P2 0: (Fixed) P3 0: CLAR Setting
11
1: CLAR Frequency
P3=0 (CLAR Setting):
P4
0: RX CLAR OFF
1: RX CLAR ON
11
P5
0: TX CLAR OFF
1: TX CLAR ON
;
P6-P8 0: (Fixed)
P3=1 (CLAR Frequency):
P4
+ / –
P5-P8 0000 – 9999 Hz
CH Set Read
CHANNEL UP/DOWN
1 2 3 4 5 6 7 8 9 10 P1 0: Memory Channel “UP”
C H P1 ;
1: Memory Channel “DOWN”
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Answer
CN Set Read Answer
CTCSS TONE FREQUENCY / DCS CODE
1 2 3 4 5 6 7 8 9 10
C N P1 P2 P3 P3 P3 ;
1 2 3 4 5 6 7 8 9 10
C N P1 P2 ;
P1 0: MAIN-side 1: SUB-side
P2 0: CTCSS 1: DCS
P3 P2=0 (CTCSS) P2=1 (DCS)
1 2 3 4 5 6 7 8 9 10
C N P1 P2 P3 P3 P3 ;
000 – 049: Tone Frequency Number (See Table 1) 000 – 103: DCS Number (See Table 2)
Table 1 (CTCSS Tone Chart)
000 67.0 Hz 009 91.5 Hz 018 123.0 Hz 027 162.2 Hz 036 189.9 Hz 045 229.1 Hz
001 69.3 Hz 010 94.8 Hz 019 127.3 Hz 028 165.5 Hz 037 192.8 Hz 046 233.6 Hz
002 71.9 Hz 011 97.4 Hz 020 131.8 Hz 029 167.9 Hz 038 196.6 Hz 047 241.8 Hz
003 74.4 Hz 012 100.0 Hz 021 136.5 Hz 030 171.3 Hz 039 199.5 Hz 048 250.3 Hz
004 77.0 Hz 013 103.5 Hz 022 141.3 Hz 031 173.8 Hz 040 203.5 Hz 049 254.1 Hz
005 79.7 Hz 014 107.2 Hz 023 146.2 Hz 032 177.3 Hz 041 206.5 Hz
–
–
006 82.5 Hz 015 110.9 Hz 024 151.4 Hz 033 179.9 Hz 042 210.7 Hz
–
–
007 85.4 Hz 016 114.8 Hz 025 156.7 Hz 034 183.5 Hz 043 218.1 Hz
–
–
008 88.5 Hz 017 118.8 Hz 026 159.8 Hz 035 186.2 Hz 044 225.7 Hz
–
–
Table 2 (DCS Code Chart)
000
023
015
074
030
165
045
261
060
356
075
462
090
627
001
025
016
114
031
172
046
263
061
364
076
464
091
631
002
026
017
115
032
174
047
265
062
365
077
465
092
632
003
031
018
116
033
205
048
266
063
371
078
466
093
654
004
032
019
122
034
212
049
271
064
411
079
503
094
662
005
036
020
125
035
223
050
274
065
412
080
506
095
664
006
043
021
131
036
225
051
306
066
413
081
516
096
703
007
047
022
132
037
226
052
311
067
423
082
523
097
712
008
051
023
134
038
243
053
315
068
431
083
526
098
723
009
053
024
143
039
244
054
325
069
432
084
532
099
731
010
054
025
145
040
245
055
331
070
445
085
546
100
732
011
065
026
152
041
246
056
332
071
446
086
565
101
734
012
071
027
155
042
251
057
343
072
452
087
606
102
743
013
072
028
156
043
252
058
346
073
454
088
612
103
754
014
073
029
162
044
255
059
351
074
455
089
624
–
–
CO
CONTOUR
123456789
Set C O P1 P2 P3 P3 P3 P3 ;
Read
123456789
C O P1 P2 ;
123456789
Answer C O P1 P2 P3 P3 P3 P3 ;
10 P1 0: MAIN-side
P3 P2=0 0000: CONTOUR “OFF”
1: SUB-side
0001: CONTOUR “ON”
10
P2 0: CONTOUR “ON/OFF” 1: CONTOUR FREQ
P2=1 0010 – 3200 (CONTOUR Frequency:10 – 3200Hz)
2: APF “ON/OFF”
P2=2 0000: APF “OFF”
10
3: APF FREQ
0001: APF “ON”
P2=3 0000 – 0050 (APF Frequency: -250 – 250 Hz )
8
CAT (Computer Aided Transceiver) Operation
CS
CW SPOT
Set
1 2 3 4 5 6 7 8 9 10 P1 0: CW SPOT “OFF”
C S P1 ;
1: CW SPOT “ON”
Read
1 2 3 4 5 6 7 8 9 10
CS ;
1 2 3 4 5 6 7 8 9 10
Answer C S P1 ;
CT
SQL TYPE
1 2 3 4 5 6 7 8 9 10 P1 0: MAIN-side
Set C T P1 P2 ;
1: SUB-side P2 0: CTCSS “OFF”
Read
1 2 3 4 5 6 7 8 9 10
C T P1 ;
1: CTCSS ENC “ON” / DEC “OFF” 2: CTCSS ENC “ON” / DEC “ON”
1 2 3 4 5 6 7 8 9 10
Answer C T P1 P2 ;
3: DCS “ON” 4: PR FREQ 5: REV TONE
DA Set Read Answer
DIMMER
1 2 3 4 5 6 7 8 9 10
D A P1 P1 P2 P2 P3 P3 P4 P4
1 2 3 4 5 6 7 8 9 10
DA ;
1 2 3 4 5 6 7 8 9 10
D A P1 P1 P2 P2 P3 P3 P4 P4
11 P1 00: (Fixed) ; P2 00 – 20: TFT Display Contrast 11 P3 00 – 20: TFT Display Brightness Level
P4 00 – 20: LED Indicators Brightness Level
11
;
DN Set Read
MIC DOWN
1 2 3 4 5 6 7 8 9 10
DN ;
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Answer
DT
DATE AND TIME
Set Read
1 2 3 4 5 6 7 ~ n-1 n P1 0: Date
D T P1 P2 P2 P2 P2 ~ P2 ;
1: Time (Local)
1 2 3 4 5 6 7 8 9 10 P2 P1=0 yyyymmdd (Year/Month/Date)
D T P1 ;
P1=1 hhmmss (Hour/Minute/Second, 24 hour time system)
1
Answer D
234567
T P1 P2 P2 P2 P2
~ n-1 ~ P2
n
;
EO Set Read Answer
ENCODER OFFSET
123456789
E O P1 P2 P3 P4 P5 P5 P5
123456789
123456789
10 P1 0: MAIN-side
;
1: SUB-side
10
2: MAIN-side and SUB-side P2 0: MAIN dial
1: FUNC knob
10 P3 +: Up
-: Down
P4 P2=0 0: Hz 1: kHz 2: MHz
P2=1 0: fix
P5 000 – 999
EX
MENU
Set Read
1 2 3 4 5 6 7 8 9 ~ nn ** P1 : 01 – 07
E X P1 P1 P2 P2 P3 P3 P4 ~ P4 ; P2 : 01 – 07
1 2 3 4 5 6 7 8 9 10 nn ** P3 : 01 – 26
E X P1 P1 P2 P2 P3 P3 ;
P4 : Parameter (See Table 3)
Answer
1
E
23456789
X P1 P1 P2 P2 P3 P3 P4
~ nn ** ~ P4 ;
9
CAT (Computer Aided Transceiver) Operation
P1
01 (RADIO SETTING)
P2 01 (MODE SSB)
02 (MODE AM)
03 (MODE FM)
Table 3 (MENU Chart)
P3
Function
P4
01 AF TREBLE GAIN
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
02 AF MIDDLE TONE GAIN
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
03 AF BASS GAIN
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
04 AGC FAST DELAY
20 – 4000 msec (P4= 0020 – 4000, 20 msec/step)
05 AGC MID DELAY
20 – 4000 msec (P4= 0020 – 4000, 20 msec/step)
06 AGC SLOW DELAY
20 – 4000 msec (P4= 0020 – 4000, 20 msec/step)
07 LCUT FREQ
00: OFF 01: 100 Hz – 19: 1000 Hz (50 Hz steps)
08 LCUT SLOPE
0: 6 dB/oct 1: 18 dB/oct
09 HCUT FREQ
00: OFF 01: 700 Hz – 67: 4000 Hz (50 Hz steps)
10 HCUT SLOPE
0: 6 dB/oct 1: 18 dB/oct
11 USB OUT LEVEL
000 – 100
12 TX BPF SEL
0: 50 – 3050 1: 100 – 2900 2: 200 – 2800 3: 300 – 2700 4: 400 – 2600 (Hz)
13 MOD SOURCE
0: MIC 1: USB 2: Bluetooth 3: AUTO
14 USB MOD GAIN
000 – 100
15 RPTT SELECT
0: OFF 1: RTS 2: DTR
16 NAR WIDTH
00: 300 01: 400 02: 600 03: 850 04: 1100 05: 1200 06: 1500 07: 1650 08: 1800 09: 1950 10: 2100 11: 2250 12: 2400 13: 2450 14: 2500 15: 2600 16: 2700 17: 2800 18: 2900 19: 3000 20: 3200 21: 3500 22: 4000 (Hz)
17 CW AUTO MODE
0: OFF 1: 50MHz 2: ON
01 AF TREBLE GAIN
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
02 AF MIDDLE TONE GAIN
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
03 AF BASS GAIN
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
04 AGC FAST DELAY
20 – 4000 msec (P4= 0020 – 4000, 20 msec/step)
05 AGC MID DELAY
20 – 4000 msec (P4= 0020 – 4000, 20 msec/step)
06 AGC SLOW DELAY
20 – 4000 msec (P4= 0020 – 4000, 20 msec/step)
07 LCUT FREQ
00: OFF 01: 100 Hz – 19: 1000 Hz (50 Hz steps)
08 LCUT SLOPE
0: 6 dB/oct 1: 18 dB/oct
09 HCUT FREQ
00: OFF 01: 700 Hz – 67: 4000 Hz (50 Hz steps)
10 HCUT SLOPE
0: 6 dB/oct 1: 18 dB/oct
11 USB OUT LEVEL
000 – 100
12 TX BPF SEL
0: 50 – 3050 1: 100 – 2900 2: 200 – 2800 3: 300 – 2700 4: 400 – 2600
13 MOD SOURCE
0: MIC 1: USB 2: Bluetooth 3: AUTO
14 USB MOD GAIN
000 – 100
15 RPTT SELECT
0: OFF 1: RTS 2: DTR
01 AF TREBLE GAIN
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
02 AF MIDDLE TONE GAIN
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
03 AF BASS GAIN
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
04 AGC FAST DELAY
20 – 4000 msec (P4= 0020 – 4000, 20 msec/step)
05 AGC MID DELAY
20 – 4000 msec (P4= 0020 – 4000, 20 msec/step)
06 AGC SLOW DELAY
20 – 4000 msec (P4= 0020 – 4000, 20 msec/step)
07 LCUT FREQ
00: OFF 01: 100 Hz – 19: 1000 Hz (50 Hz steps)
08 LCUT SLOPE
0: 6 dB/oct 1: 18 dB/oct
09 HCUT FREQ
00: OFF 01: 700 Hz – 67: 4000 Hz (50 Hz steps)
10 HCUT SLOPE
0: 6 dB/oct 1: 18 dB/oct
11 USB OUT LEVEL
000 – 100
12 MOD SOURCE
0: MIC 1: USB 2: Bluetooth 3: AUTO
13 USB MOD GAIN
000 – 100
14 RPTT SELECT
0: OFF 1: RTS 2: DTR
15 RPT SHIFT
0: – 1: SIMPLEX 2: + 3: ARS
16 RPT SHIFT(28MHz)
0 – 1000 kHz (P4 = 0000 – 1000, 10 kHz/step)
17 RPT SHIFT(50MHz)
0 – 4000 kHz (P4 = 0000 – 4000, 10 kHz/step)
18 RPT SHIFT(144MHz)
0 – 100MHz (P4 = 0000 – 0100, 50 kHz/step)
19 RPT SHIFT(430MHz)
0 – 100MHz (P4 = 0000 – 0100, 50 kHz/step)
20 SQL TYPE
0: OFF 1: ENC 2: TSQ 3: DCS 4: PR FREQ 5: REV TONE
21 TONE FREQ
00: 67.0 – 49: 254.1Hz
22 DCS CODE
00: 023 – 103: 754
23 DCS RX REVERS
0: NORMAL 1: REVERS 2: BOTH
24 DCS TX REVERS
0: NORMAL 1: REVERS
25 PR FREQ
300 – 3000 Hz (P4= 0300 – 3000, 100 Hz/step)
26 DTMF DELAY
0: 50 1: 250 2: 450 3: 750 4: 1000 (ms)
27 DTMF SPEED
0: 50 1: 100 (ms)
28 DTMF MEMORY1
0 – 9, A, B, C, D, *, #, – (space) (Up to 16 characters)
29 DTMF MEMORY2
0 – 9, A, B, C, D, *, #, – (space) (Up to 16 characters)
30 DTMF MEMORY3
0 – 9, A, B, C, D, *, #, – (space) (Up to 16 characters)
31 DTMF MEMORY4
0 – 9, A, B, C, D, *, #, – (space) (Up to 16 characters)
32 DTMF MEMORY5
0 – 9, A, B, C, D, *, #, – (space) (Up to 16 characters)
33 DTMF MEMORY6
0 – 9, A, B, C, D, *, #, – (space) (Up to 16 characters)
34 DTMF MEMORY7
0 – 9, A, B, C, D, *, #, – (space) (Up to 16 characters)
35 DTMF MEMORY8
0 – 9, A, B, C, D, *, #, – (space) (Up to 16 characters)
36 DTMF MEMORY9
0 – 9, A, B, C, D, *, #, – (space) (Up to 16 characters)
37 DTMF MEMORY10
0 – 9, A, B, C, D, *, #, – (space) (Up to 16 characters)
Digits 3 3 3 4 4 4 2 1 2 1 3 1 1 3 1
2
1 3 3 3 4 4 4 2 1 2 1 3 1 1 3 1 3 3 3 4 4 4 2 1 2 1 3 1 3 1 1 4 4 4 4 1 2 2 1 1 4 1 1 16 16 16 16 16 16 16 16 16 16
10
CAT (Computer Aided Transceiver) Operation
P1
01 (RADIO SETTING)
02 (CW SETTING)
P2
04 (MODE DATA)
05 (MODE RTTY)
06 (DIGITAL)
01 (MODE CW)
02 (KEYER)
Table 3 (MENU Chart)
P3
Function
P4
01 AF TREBLE GAIN
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
02 AF MIDDLE TONE GAIN
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
03 AF BASS GAIN
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
04 AGC FAST DELAY
20 – 4000 msec (P4= 0020 – 4000, 20 msec/step)
05 AGC MID DELAY
20 – 4000 msec (P4= 0020 – 4000, 20 msec/step)
06 AGC SLOW DELAY
20 – 4000 msec (P4= 0020 – 4000, 20 msec/step)
07 LCUT FREQ
00: OFF 01: 100 Hz – 19: 1000 Hz (50 Hz steps)
08 LCUT SLOPE
0: 6 dB/oct 1: 18 dB/oct
09 HCUT FREQ
00: OFF 01: 700 Hz – 67: 4000 Hz (50 Hz steps)
10 HCUT SLOPE
0: 6 dB/oct 1: 18 dB/oct
11 USB OUT LEVEL
000 – 100
12 TX BPF SEL
0: 50 – 3050 1: 100 – 2900 2: 200 – 2800 3: 300 – 2700 4: 400 – 2600
13 MOD SOURCE
0: MIC 1: USB 2: Bluetooth 3: AUTO
14 USB MOD GAIN
000 – 100
15 RPTT SELECT
0: OFF 1: RTS 2: DTR
16 NAR WIDTH
00: 50 01:100 02: 150 03: 200 04: 250 05: 300 06: 350 07: 400 08: 450 09: 500 10: 600 11: 800 12: 1200 13: 1400 14: 1700 15: 2000 16: 2400 17: 3000 18: 3200 19: 3500 20: 4000 (Hz)
17 PSK TONE
0: 1000Hz 1: 1500Hz 2: 2000Hz
18 DATA SHIFT (SSB)
0 – 3000 Hz (P4 = 0000 – 3000, 10 Hz steps)
01 AF TREBLE GAIN
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
02 AF MIDDLE TONE GAIN
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
03 AF BASS GAIN
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
04 AGC FAST DELAY
20 – 4000 msec (P4= 0020 – 4000, 20 msec/step)
05 AGC MID DELAY
20 – 4000 msec (P4= 0020 – 4000, 20 msec/step)
06 AGC SLOW DELAY
20 – 4000 msec (P4= 0020 – 4000, 20 msec/step)
07 LCUT FREQ
00: OFF 01: 100 Hz – 19: 1000 Hz (50 Hz steps)
08 LCUT SLOPE
0: 6 dB/oct 1: 18 dB/oct
09 HCUT FREQ
00: OFF 01: 700 Hz – 67: 4000 Hz (50 Hz steps)
10 HCUT SLOPE
0: 6 dB/oct 1: 18 dB/oct
11 USB OUT LEVEL
000 – 100
12 RPTT SELECT
0: OFF 1: RTS 2: DTR
13 NAR WIDTH
00: 50 01:100 02: 150 03: 200 04: 250 05: 300 06: 350 07: 400 08: 450 09: 500 10: 600 11: 800 12: 1200 13: 1400 14: 1700 15: 2000 16: 2400 17: 3000 18: 3200 19: 3500 20: 4000 (Hz)
14 MARK FREQUENCY
0: 1275 Hz 1: 2125 Hz
15 SHIFT FREQUENCY
0: 170 Hz 1: 200 Hz 2: 425 Hz 3: 850 Hz
16 POLARITY-TX
0: NOR 1: REV
01 DIGITAL POPUP
00: OFF 01: 2 sec – 59: 60sec 60: CONTINUE
02 LOCATION SERVICE
0: OFF 1: ON
03 STANDBY BEEP
0: OFF 1: ON
04 DP-ID LIST
05 RADIO ID
01 AF TREBLE GAIN
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
02 AF MIDDLE TONE GAIN
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
03 AF BASS GAIN
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
04 AGC FAST DELAY
20 – 4000 msec (P4= 0020 – 4000, 20 msec/step)
05 AGC MID DELAY
20 – 4000 msec (P4= 0020 – 4000, 20 msec/step)
06 AGC SLOW DELAY
20 – 4000 msec (P4= 0020 – 4000, 20 msec/step)
07 LCUT FREQ
00: OFF 01: 100 Hz – 19: 1000 Hz (50 Hz steps)
08 LCUT SLOPE
0: 6 dB/oct 1: 18 dB/oct
09 HCUT FREQ
00: OFF 01: 700 Hz – 67: 4000 Hz (50 Hz steps)
10 HCUT SLOPE
0: 6 dB/oct 1: 18 dB/oct
11 USB OUT LEVEL
000 – 100
12 RPTT SELECT
0: OFF 1: RTS 2: DTR
13 NAR WIDTH
00: 50 01:100 02: 150 03: 200 04: 250 05: 300 06: 350 07: 400 08: 450 09: 500 10: 600 11: 800 12: 1200 13: 1400 14: 1700 15: 2000 16: 2400 17: 3000 18: 3200 19: 3500 20: 4000 (Hz)
14 PC KEYING
0: OFF 1: RTS 2: DTR
15 CW BK-IN TYPE
0: SEMI 1: FULL
16 CW FREQ DISPLAY
0: DIRECT FREQ 1: PITCH OFFSET
17 QSK DELAY TIME
0: 15 msec 1: 20 msec 2: 25 mesc 3: 30 msec
18 CW INDICATOR
0: OFF 1: ON
01 KEYER TYPE
0: OFF 1: BUG 2: ELEKEY-A 3: ELEKEY-B 4: ELEKEY-Y 5: ACS
02 KEYER DOT/DASH
0: NOR 1: REV
03 CW WEIGHT
2.5 – 4.5 (P4 = 25 – 45)
04 NUMBER STYLE
0: 1290 1: AUNO 2: AUNT 3: A2NO 4: A2NT 5: 12NO 6: 12NT
05 CONTEST NUMBER
0001 – 9999
06 CW MEMORY 1
0: TEXT 1: MESSAGE
07 CW MEMORY 2
0: TEXT 1: MESSAGE
08 CW MEMORY 3
0: TEXT 1: MESSAGE
09 CW MEMORY 4
0: TEXT 1: MESSAGE
10 CW MEMORY 5
0: TEXT 1: MESSAGE
11 REPEAT INTERVAL
1 – 60 sec (P4 = 01 – 60)
Digits 3 3 3 4 4 4 2 1 2 1 3 1 1 3 1
2
1 4 3 3 3 4 4 4 2 1 2 1 3 1
2
1 1 1 2 1 1 3 3 3 4 4 4 2 1 2 1 3 1
2
1 1 1 1 1 1 1 2 1 4 1 1 1 1 1 2
11
CAT (Computer Aided Transceiver) Operation
P1
P2
01 (GENERAL)
02 (BAND-SCAN)
03 (RX-DSP)
03 (OPERATION SETTING)
04 (TX AUDIO)
05 (TX GENERAL)
06 (KEY/DIAL)
Table 3 (MENU Chart)
P3
Function
P4
01 BEEP LEVEL
000 – 100
02 RF/SQL VR
0: RF 1: SQL 2:SQL (FM MODE only)
03 TUN/LIN PORT SELECT
0: EXT-TUNER 1: LINEAR 2: CAT-3 3: GPO
04 TUNER SELECT
0: INT 1: INT (FAST) 2: EXT 3: ATAS
05 CAT-1 RATE
0: 4800 bps 1: 9600 bps 2: 19200 bps 3: 38400 bps 4:115200 bps
06 CAT-1 TIME OUT TIMER
0: 10 msec 1: 100 msec 2: 1000 msec 3: 3000 msec
07 CAT-1 CAT-3 STOP BIT
0: 1 bit 1: 2 bit
08 CAT-2 RATE
0: 4800 bps 1: 9600 bps 2: 19200 bps 3: 38400 bps 4:115200 bps
09 CAT-2 TIME OUT TIMER
0: 10 msec 1: 100 msec 2: 1000 msec 3: 3000 msec
10 CAT-3 RATE
0: 4800 bps 1: 9600 bps 2: 19200 bps 3: 38400 bps 4:115200 bps
11 CAT-3 TIME OUT TIMER
0: 10 msec 1: 100 msec 2: 1000 msec 3: 3000 msec
12 TX TIME OUT TIMER
00: OFF 01: 01 min – 30: 30 min (P4= 00 – 30)
13 REF FREQ ADJ
-25 – +00 (or -00) – +25 (P4= -25 – +00 or -00 – +25)
14 CHARGE CONTROL
0: OFF 1: ON
15 SUB BAND MUTE
0: OFF 1: ON
16 SPEAKER SELECT
0: Auto 1: INT 2: BOTH
17 DITHER
0: OFF 1: ON
01 QMB CH
0: 5ch 1: 10ch
02 BAND STACK
0: OFF 1: ON
03 BAND EDGE
0: OFF 1: ON
04 SCAN RESUME
0: BUSY 1: HOLD 2: 1sec 3: 3sec 4: 5sec
01 IF NOTCH WIDTH
0: NARROW 1: WIDE
02 NB REJECTION
0: LOW 1: MID 2: HIGH
03 NB WIDTH
0: NARROW 1: MEDIUM 2: WIDE
04 APF WIDTH
0: NARROW 1: MEDIUM 2: WIDE
05 CONTOUR LEVEL
-40 – -00 (or +00) – +20 (P4 = -40 – -00 or +00 – +20)
06 CONTOUR WIDTH
01 – 11
01 AMC RELEASE TIME
0: FAST 1: MID 2: SLOW
02 PRMTRC EQ1 FREQ
00 : OFF 01: 100 Hz – 07: 700 Hz (100 Hz steps)
03 PRMTRC EQ1 LEVEL
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
04 PRMTRC EQ1 BWTH
00 – 10
05 PRMTRC EQ2 FREQ
00: OFF 01: 700 Hz – 09: 1500 Hz (100 Hz steps)
06 PRMTRC EQ2 LEVEL
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
07 PRMTRC EQ2 BWTH
00 – 10
08 PRMTRC EQ3 FREQ
00 : OFF 01: 1500 Hz – 18: 3200 Hz (100 Hz steps)
09 PRMTRC EQ3 LEVEL
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
10 PRMTRC EQ3 BWTH
00 – 10
11 P PRMTRC EQ1 FREQ
00 : OFF 01: 100 Hz – 07: 700 Hz (100 Hz steps)
12 P PRMTRC EQ1 LEVEL
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
13 P PRMTRC EQ1 BWTH
00 – 10
14 P PRMTRC EQ2 FREQ
00: OFF 01: 700 Hz – 09: 1500 Hz (100 Hz steps)
15 P PRMTRC EQ2 LEVEL
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
16 P PRMTRC EQ2 BWTH
00 – 10
17 P PRMTRC EQ3 FREQ
00 : OFF 01: 1500 Hz – 18: 3200 Hz (100 Hz steps)
18 P PRMTRC EQ3 LEVEL
-20 – -00 (or +00) – +10 (P4 = -20 – -00 or +00 – +10)
19 P PRMTRC EQ3 BWTH
00 – 10
01 MAX POWER (BAT)
005 – 060 (P4 = 005 – 060)
02 QRP MODE
0: OFF 1: ON
03 HF MAX POWER
005 – 010 (P4 = 005 – 010)
04 50M MAX POWER
005 – 010 (P4 = 005 – 010)
05 70M MAX POWER
005 – 060 (P4 = 005 – 060)
06 144M MAX POWER
005 – 100 (P4 = 005 – 100)
07 430M MAX POWER
005 – 100 (P4 = 005 – 100)
08 AM HF/50 MAX POWER
005 – 025 (P4 = 005 – 025)
09 AM V/U MAX POWER
005 – 025 (P4 = 005 – 025)
10 VOX SELECT
0: MIC 1: USB 2: Bluetooth
11 EMERGENCY FREQ TX
0: OFF 1: ON
12 TX INHIBIT
0: OFF 1: ON
13 METER DETECTOR
0: AVERAGE 1: PEAK
01 SSB/CW DIAL STEP
0: 5 1: 10 2: 20 (Hz)
02 RTTY/PSK DIAL STEP
0: 5 1: 10 2: 20 (Hz)
03 FM DIAL STEP
0: 5 1: 6.25 2: 10 3: 12.5 4: 20 5: 25 (kHz) 6: Auto
04 CH STEP
0: 1 1: 2.5 2: 5 3: 10 (kHz)
05 AM CH STEP
0: 2.5 1: 5 2: 9 3: 10 4: 12.5 5: 25 (kHz)
06 FM CH STEP
0: 5 1: 6.25 2: 10 3: 12.5 4: 20 5: 25 (kHz)
07 MAIN STEPS PER REV.
0: 50 1: 100 2: 200
08 MIC P1
09 MIC P2 10 MIC P3 11 MIC P4 12 MIC UP 13 MIC DOWN
00:LOCK 05:VOX/MOX 10:NAR 15:BAND UP 20:AGC
01:QMB 06:MODE 11:NB 16:BAND DOWN
02:>/< 07:ZIN/SPOT 12:DNR 17 ATT
03:V/M 08:SPLIT 13:FREQ UP 18:IPO
04:TUNER 09:FINE 14:FREQ DOWN 19:DNF
14 MIC SCAN
0: OFF 1: ON
Digits 3 1 1 1 1 1 1 1 1 1 1 2 3 1 1 1 1 1 1 1 1 1 1 1 1 3 2 1 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 2 3 2 3 1 3 3 3 3 3 3 3 1 1 1 1 1 1 1 1 1 1 1
2
1
12
CAT (Computer Aided Transceiver) Operation
P1
P2
03 (OPERATION SETTING)
07 (OPTION)
01 (DISPLAY)
04 (DISPLAY SETTING)
02 (UNIT)
03 (SCOPE)
04 (VFO IND COLOR)
01 (DATE&TIME)
01 (MY POSITION)
05 (EXTENSION SETTING)
02 (SD CARD)
03 (SOFT VERSION)
04 (CALIBRATION)
05 (RESET)
05 (CERTIFICATION)
Table 3 (MENU Chart)
P3
Function
P4
01 TUNER TYPE SEL ANT1
0: INT 1: INT(FAST) 2: EXT 3: ATAS
02 TUNER TYPE SEL ANT2
0: INT 1: INT(FAST) 2: EXT 3: ATAS
03 ANT2 OPERATION
0: TRX 1: TX-ANT1, RX-ANT2 2: TRX-ANT1, RX-ANT2
04 HF ANT SELECT
0: ANT1 1: ANT2
05 HF MAX POWER
005 – 100 (P4 = 005 – 100)
06 50M MAX POWER
005 – 100 (P4 = 005 – 100)
07 70M MAX POWER
005 – 050 (P4 = 005 – 050)
08 144M MAX POWER
005 – 050 (P4 = 005 – 050)
09 430M MAX POWER
005 – 050 (P4 = 005 – 050)
10 AM MAX POWER
005 – 025 (P4 = 005 – 025)
11 AM V/U MAX POWER
005 – 013 (P4 = 005 – 013)
12 GPS
0: OFF 1: ON
13 GPS PINNING
0: OFF 1: ON
14 GPS BAUDRATE
0: 4800 1: 9600 2: 19200 3: 38400 4: 115200 (bps)
15 BLUETOOTH
01 MY CALL
Up to 10 characters
02 MY CALL TIME
0: OFF 1: 1 2: 2 3: 3 4: 4 5: 5 (sec)
03 POP-UP TIME
0: FAST 1: MID 2: SLOW
04 SCREEN SAVER
0: OFF 1: 1 2: 2 3: 5 4: 15 5: 30 6: 60 (min)
05 SCREEN SAVER(BAT)
0: OFF 1: 1 2: 2 3: 5 4: 15 5: 30 6: 60 (min)
06 SAVER TYPE
0: Logo 1: DIMMER 2: DISP OFF
07 AUTO POWER OFF
0: OFF 1: 0.5 – 24: 12 (hour)
08 LED DIMMER
00 – 20
01 POSITION UNIT
0: dd°MM.mm’. 1: dd°mm’ss”
02 DISTANCE UNIT
0: km 1: mile
03 SPEED UNIT
0: km/h 1: knot 3: mph
04 ALTITUDE UNIT
0: m 1: ft
05 TEMP UNIT
0: °C 1: °F
06 RAIN UNIT
0: mm 1: INCH
07 WIND UNIT
0: m/s 2: mph
01 RBW
0: HIGH 1: MID 2: LOW
02 SCOPE CTR
0: FILTER 1: CARRIER
03 2D DISP SENSITIVITY
0: NORMAL 1: HI
04 3DSS DISP SENSITIVITY
0: NORMAL 1: HI
05 AVERAGE
0: OFF 1: 2 2: 4 3: 8
01 VMI COLOR VFO
0: BLUE 1: GREEN 2: WHITE 3: NONE
02 VMI COLOR MEMORY
0: BLUE 1: GREEN 2: WHITE 3: NONE
03 VMI COLOR CLAR
0: RED 1: NONE
01 TIME ZONE
-12 (-120) – 0 – +14 (+140) (h) (0.5h steps)
02 DAY
03 MONTH
04 YEAR
05 HOUR
06 MINUTE
07 GPS TIME SET
0: AUTO 1: MANUAL
08 MY POSITION
0: GPS 1: MANUAL
09 MY POSITION LATITUDE
Latitude: x xx°xx’ xx”
10 MY POSITION LONGITUDE Longitude: x xxx°xx’ xx”
01 MEM LIST LOAD
02 MEM LIST SAVE
03 MENU LOAD
04 MENU SAVE
05 INFORMATIONS
06 FIRMWARE UPDATE
07 FORMAT
01 SOFT VERSION
01 CALIBRATION
01 MEMORY CLEAR
02 MENU CLEAR
03 ALL RESET
04 CERTIFICATION
Digits 1 1 1 1 3 3 3 3 3 3 3 1 1 1 10 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4 1 1 –
–
–
–
–
13
CAT (Computer Aided Transceiver) Operation
P1 06 (APRS SETTING)
07 (APRS BEACON)
08 (APRS FILTER)
P2
01 (GENERAL)
02 (MSG TEMPLATE)
03 (MY SYMBOL)
04 (DIGI PATH)
01 (BEACON SET.)
02 (AUTO BEACON)
03 (SmartBeac.)
04 (BEACON TEXT)
01 (LIST SETTING)
02 (STATION LIST)
03 (POPUP)
04 (RINGER)
06 (MSG FIL.)
P3
Function
01 MODEM SELECT
02 MODEM TYPE
03 APRS AF MUTE
Table 3 (MENU Chart)
0: OFF 1: AUTO 2: MAIN 0: 1200bps 1: 9600bps 0: OFF 1: ON
P4 3: SUB
Digits 1 1 1
04 APRS TX DELAY
0: 100ms 1: 200ms 2: 300ms 3: 400ms 4: 500ms 5: 750ms 6: 1000ms
1
05 CALLSIGN(APRS)
xxxxxx-xx
8
09 APRS DESTINATION
APYX01 (fix)
6
01 MESSAGE TEXT1
Up to 16 characters (ASCII)
16
02 MESSAGE TEXT2
Up to 16 characters (ASCII)
16
03 MESSAGE TEXT3
Up to 16 characters (ASCII)
16
04 MESSAGE TEXT4
Up to 16 characters (ASCII)
16
05 MESSAGE TEXT5
Up to 16 characters (ASCII)
16
06 MESSAGE TEXT6
Up to 16 characters (ASCII)
16
07 MESSAGE TEXT7
Up to 16 characters (ASCII)
16
08 MESSAGE TEXT8
Up to 16 characters (ASCII)
16
01 MY SYNBOL
0: ICON1 1: ICON2 2: ICON3 3: USER
1
02 ICON1
See Table 4 (see page 16)
2
03 ICON2
See Table 4 (see page 16)
2
04 ICON3
See Table 4 (see page 16)
2
05 USER
See Table 4 (see page 16)
2
01 PATH SELECT
0: OFF 1: WIDE1-1 2: WIDE1-1.WIDE2-1
1
01 BEACON TYPE 02 INFO AMBIGUITY 03 INFO SPEED/COURSE 04 INFO ALTITUDE
05 POSITION COMMENT
06 EMERGENCY BEACON
01 INTERVAL TIME
02 PROPORTIONAL 03 DECAY 04 AUTO LOW SPEED 05 BEACON DELAY 01 SMART LOW SPEED 02 SMART HIGH SPEED 03 SMART SLOW RATE 04 SMART FAST RATE 05 SMART TURN ANGLE 06 SMART TURN SLOPE 07 SMART TURN TIME 01 STATUS TEXT SELECT 02 TX RATE 03 BEACON FREQUENCY 04 STATUS TEXT1 05 STATUS TEXT2 06 STATUS TEXT3 07 STATUS TEXT4 08 STATUS TEXT5
0: OFF 1: AUTO 2: SMART
1
0: OFF 1: 1dig 2: 2dig 3: 3dig 4: 4dig
1
0: OFF 1: ON
1
0: OFF 1: ON
1
00: Off duty 01: En Route 02: In Service 03: Returning 04: Committed
05: Special 06: Priority
07: Custom 0 08: Custom 1 09: Custom 2
2
10: Custom 3 11: Custom 4 12: Custom 5 13: Custom 6 14: EMERGENCY!
0: OFF 1: ON
1
0:30sec / 1:1min / 2:2min / 3:3min / 4:5min / 5:10min / 6:15min / 7:20min / 8:30min / 9:60min
1
0: OFF 1: ON
1
0: OFF 1:ON
1
01 – 99 (km/h or mph (1km or 1mph/Step)
2
005 – 180 (sec)
3
02 – 30 (km/h or mph (1km or 1mph/Step)
2
03 – 90 (km/h or mph (1km or 1mph/Step)
2
001 – 100 (min) (1min/step)
3
010 – 180 (sec) (1sec/step)
3
05 – 90 (degree) (1degree/step)
2
001 – 255 (1/step)
3
005 – 180 (sec) (1sec/step)
3
0: OFF 1: TEXT1 2: TEXT2 3: TEXT3 4: TEXT4 5: TEXT5
1
0: 1/1 1: 1/2 2: 1/3 3: 1/4 4: 1/5 5: 1/6 6: 1/7 7: 1/8
1
0: None 1: FREQUENCY 2: FREQ & SQL & SHIFT
1
Up to 60 characters (ASCII)
60
Up to 60 characters (ASCII)
60
Up to 60 characters (ASCII)
60
Up to 60 characters (ASCII)
60
Up to 60 characters (ASCII)
60
01 STATION LIST SORT
0: TIME 1: CALLSIGN 2: DISTANCE
1
01 Mic-E
0: OFF 1: ON
1
02 POSITION
0: OFF 1: ON
1
03 WEATHER
0: OFF 1: ON
1
04 OBJECT
0: OFF 1: ON
1
05 ITEM
0: OFF 1: ON
1
06 STATUS
0: OFF 1: ON
1
07 OTHER
0: OFF 1: ON
1
08 ALTNET
0: OFF 1: ON
1
01 BEACON
0: OFF 1: 3sec 2: 5sec 3: 10sec 4: HOLD
1
02 MESSAGE
0: OFF 1: 3sec 2: 5sec 3: 10sec 4: HOLD
1
03 MY PACKET
0: OFF 1: ON
1
01 TX BEACON
0: OFF 1: ON
1
02 RX BEACON
0: OFF 1: ON
1
03 TX MESSAGE
0: OFF 1: ON
1
04 RX MESSAGE
0: OFF 1: ON
1
07 MY PACKET
0: OFF 1: ON
1
01 MESSAGE GROUP1
Up to 9 characters (ASCII)
9
02 MESSAGE GROUP2
Up to 9 characters (ASCII)
9
03 MESSAGE GROUP3
Up to 9 characters (ASCII)
9
04 MESSAGE GROUP4
Up to 9 characters (ASCII)
9
05 MESSAGE GROUP5
Up to 9 characters (ASCII)
9
06 MESSAGE GROUP6
Up to 9 characters (ASCII)
9
07 BULLETIN 1
Up to 9 characters (ASCII)
9
08 BULLETIN 2
Up to 9 characters (ASCII)
9
09 BULLETIN 3
Up to 9 characters (ASCII)
9
14
CAT (Computer Aided Transceiver) Operation
P1
09 (PRESET)
P2 01 (PRESET1)
02 (PRESET2)
03 (PRESET3)
04 (PRESET4)
05 (PRESET5)
Table 3 (MENU Chart)
P3
Function
P4
01 PRESET NAME
Up to 12 characters
02 CAT-1 RATE
0: 4800 bps 1: 9600 bps 2: 19200 bps 3: 38400 bps 4:115200 bps
03 CAT-1 TIME OUT TIMER
0: 10 msec 1: 100 msec 2: 1000 msec 3: 3000 msec
04 CAT-1 CAT-3 STOP BIT
0: 1 bit 1: 2 bit
05 AGC FAST DELAY
20 – 4000 (P4 = 0020 – 4000, 20 msec steps)
06 AGC MID DELAY
20 – 4000 (P4 = 0020 – 4000, 20 msec steps)
07 AGC SLOW DELAY
20 – 4000 (P4 = 0020 – 4000, 20 msec steps)
08 LCUT FREQ
00: OFF 01: 100 Hz – 19: 1000 Hz (50 Hz steps)
09 LCUT SLOPE
0: 6dB/oct 1: 18dB/oct
10 HCUT FREQ
00: OFF 01:700Hz – 67:4000Hz (50 Hz steps)
11 HCUT SLOPE
0: 6dB/oct 1: 18dB/oct
12 USB OUT LEVEL
000 – 100
13 TX BPF SEL
0: 50 – 3050 1: 100 – 2900 2: 200 – 2800 3: 300 – 2700 4: 400 – 2600 Hz
14 MOD SOURCE
0: MIC 1: USB 2: REAR (RTTY/DATA Jack) 3: AUTO
15 USB MOD GAIN
000 – 100
16 RPTT SELECT
0: OFF 1: RTS 2:DTR 3:DAKY (RTTY/DATA Jack)
01 PRESET NAME
Up to 12 characters
02 CAT-1 RATE
0: 4800 bps 1: 9600 bps 2: 19200 bps 3: 38400 bps 4:115200 bps
03 CAT-1 TIME OUT TIMER
0: 10 msec 1: 100 msec 2: 1000 msec 3: 3000 msec
04 CAT-1 CAT-3 STOP BIT
0: 1 bit 1: 2 bit
05 AGC FAST DELAY
20 – 4000 (P4 = 0020 – 4000, 20 msec steps)
06 AGC MID DELAY
20 – 4000 (P4 = 0020 – 4000, 20 msec steps)
07 AGC SLOW DELAY
20 – 4000 (P4 = 0020 – 4000, 20 msec steps)
08 LCUT FREQ
00: OFF 01: 100 Hz – 19: 1000 Hz (50 Hz steps)
09 LCUT SLOPE
0: 6dB/oct 1: 18dB/oct
10 HCUT FREQ
00: OFF 01:700Hz – 67:4000Hz (50 Hz steps)
11 HCUT SLOPE
0: 6dB/oct 1: 18dB/oct
12 USB OUT LEVEL
000 – 100
13 TX BPF SEL
0: 50 – 3050 1: 100 – 2900 2: 200 – 2800 3: 300 – 2700 4: 400 – 2600 Hz
14 MOD SOURCE
0: MIC 1: USB 2: REAR (RTTY/DATA Jack) 3: AUTO
15 USB MOD GAIN
000 – 100
16 RPTT SELECT
0: OFF 1: RTS 2:DTR 3:DAKY (RTTY/DATA Jack)
01 PRESET NAME
Up to 12 characters
02 CAT-1 RATE
0: 4800 bps 1: 9600 bps 2: 19200 bps 3: 38400 bps 4:115200 bps
03 CAT-1 TIME OUT TIMER
0: 10 msec 1: 100 msec 2: 1000 msec 3: 3000 msec
04 CAT-1 CAT-3 STOP BIT
0: 1 bit 1: 2 bit
05 AGC FAST DELAY
20 – 4000 (P4 = 0020 – 4000, 20 msec steps)
06 AGC MID DELAY
20 – 4000 (P4 = 0020 – 4000, 20 msec steps)
07 AGC SLOW DELAY
20 – 4000 (P4 = 0020 – 4000, 20 msec steps)
08 LCUT FREQ
00: OFF 01: 100 Hz – 19: 1000 Hz (50 Hz steps)
09 LCUT SLOPE
0: 6dB/oct 1: 18dB/oct
10 HCUT FREQ
00: OFF 01:700Hz – 67:4000Hz (50 Hz steps)
11 HCUT SLOPE
0: 6dB/oct 1: 18dB/oct
12 USB OUT LEVEL
000 – 100
13 TX BPF SEL
0: 50 – 3050 1: 100 – 2900 2: 200 – 2800 3: 300 – 2700 4: 400 – 2600 Hz
14 MOD SOURCE
0: MIC 1: USB 2: REAR (RTTY/DATA Jack) 3: AUTO
15 USB MOD GAIN
000 – 100
16 RPTT SELECT
0: OFF 1: RTS 2:DTR 3:DAKY (RTTY/DATA Jack)
01 PRESET NAME
Up to 12 characters
02 CAT-1 RATE
0: 4800 bps 1: 9600 bps 2: 19200 bps 3: 38400 bps 4:115200 bps
03 CAT-1 TIME OUT TIMER
0: 10 msec 1: 100 msec 2: 1000 msec 3: 3000 msec
04 CAT-1 CAT-3 STOP BIT
0: 1 bit 1: 2 bit
05 AGC FAST DELAY
20 – 4000 (P4 = 0020 – 4000, 20 msec steps)
06 AGC MID DELAY
20 – 4000 (P4 = 0020 – 4000, 20 msec steps)
07 AGC SLOW DELAY
20 – 4000 (P4 = 0020 – 4000, 20 msec steps)
08 LCUT FREQ
00: OFF 01: 100 Hz – 19: 1000 Hz (50 Hz steps)
09 LCUT SLOPE
0: 6dB/oct 1: 18dB/oct
10 HCUT FREQ
00: OFF 01:700Hz – 67:4000Hz (50 Hz steps)
11 HCUT SLOPE
0: 6dB/oct 1: 18dB/oct
12 USB OUT LEVEL
000 – 100
13 TX BPF SEL
0: 50 – 3050 1: 100 – 2900 2: 200 – 2800 3: 300 – 2700 4: 400 – 2600 Hz
14 MOD SOURCE
0: MIC 1: USB 2: REAR (RTTY/DATA Jack) 3: AUTO
15 USB MOD GAIN
000 – 100
16 RPTT SELECT
0: OFF 1: RTS 2:DTR 3:DAKY (RTTY/DATA Jack)
01 PRESET NAME
Up to 12 characters
02 CAT-1 RATE
0: 4800 bps 1: 9600 bps 2: 19200 bps 3: 38400 bps 4:115200 bps
03 CAT-1 TIME OUT TIMER
0: 10 msec 1: 100 msec 2: 1000 msec 3: 3000 msec
04 CAT-1 CAT-3 STOP BIT
0: 1 bit 1: 2 bit
05 AGC FAST DELAY
20 – 4000 (P4 = 0020 – 4000, 20 msec steps)
06 AGC MID DELAY
20 – 4000 (P4 = 0020 – 4000, 20 msec steps)
07 AGC SLOW DELAY
20 – 4000 (P4 = 0020 – 4000, 20 msec steps)
08 LCUT FREQ
00: OFF 01: 100 Hz – 19: 1000 Hz (50 Hz steps)
09 LCUT SLOPE
0: 6dB/oct 1: 18dB/oct
10 HCUT FREQ
00: OFF 01:700Hz – 67:4000Hz (50 Hz steps)
11 HCUT SLOPE
0: 6dB/oct 1: 18dB/oct
12 USB OUT LEVEL
000 – 100
13 TX BPF SEL
0: 50 – 3050 1: 100 – 2900 2: 200 – 2800 3: 300 – 2700 4: 400 – 2600 Hz
14 MOD SOURCE
0: MIC 1: USB 2: REAR (RTTY/DATA Jack) 3: AUTO
15 USB MOD GAIN
000 – 100
16 RPTT SELECT
0: OFF 1: RTS 2:DTR 3:DAKY (RTTY/DATA Jack)
15
Digits 12 1 1 1 4 4 4 2 1 2 1 3 1 1 3 1 12 1 1 1 4 4 4 2 1 2 1 3 1 1 3 1 12 1 1 1 4 4 4 2 1 2 1 3 1 1 3 1 12 1 1 1 4 4 4 2 1 2 1 3 1 1 3 1 12 1 1 1 4 4 4 2 1 2 1 3 1 1 3 1
CAT (Computer Aided Transceiver) Operation
Table 3 (MENU Chart)
P1
P2
P3
Function
P4
01 Bluetooth
0: OFF 1: ON
11 (BLUETOOTH)
01
02 Device Name : Status
(Bluetooth)
03 DEVICE LIST
04 AUDIO
0: AUTO 1: FIX
Digits 1 1 1
Table 4 (MY SYMBOL Chart)
P4
ICON
P4
ICON
P4
ICON
P4
ICON
/ 0
Circle
/ _ Weather Station / j
Jeep
/ u
Bus
/ ‘
Small Aircraft / <
Motorcycle
/ K
School
/ V
ATV
/ – House QTH (VHF) / = Railroad Engine / k
School
/ v
ATV
/ #
DIGI
/ >
Car
/ m Mic-E Repeater / W
NWS Site
/ & HF Gateway / a
Ambulance
/ O
Balloon
/ X
Helicopter
/ .
X
/ b
Bycycle
/ P
Police
/ Y Yacht(sailboat)
/ :
Fire
/ C
Canoe
/ R
REC.Vehicle
/ y Yacht(sailboat)
/ ;
Campground / E
Eyeball
/ r
REC.Vehicle
0
Circle
/ [ Human/Person / f
Fire Truck
/ s Ship(powerboat) –
House (HF)
/
Triangle(DF)
/ g
Glider
/ T
SSTV
# Overlay DIGI
/ ^ Large Aircraft / I
TCP/IP
/ U
Bus
& Overlay Gate
P4
ICON
P4
ICON
.
Ambiguous
u Overlayed Truck
; Park/Picnic Area v Overlayed Van
^
Aircraft
W
NWS Site
_
WX Site
x
Obstruction
=
APRStt
Y Radios & Devices
> Overlayed Car E 0
EchoLink
A
APRStt
I 0
IRLP
K Kenwood HT K Y Kenwood Radios
m Value Signpost W 0
WIRES
n Overlay Triangle Y Y Yaesu Radios
s Overlayed Ship
FA Set Read Answer
FREQUENCY VFO MAIN-SIDE 1 2 3 4 5 6 7 8 9 10 11 12 P1 000030000 – 470000000 (Hz) F A P1 P1 P1 P1 P1 P1 P1 P1 P1 ;
1 2 3 4 5 6 7 8 9 10 11 12
FA ;
1 2 3 4 5 6 7 8 9 10 11 12
F A P1 P1 P1 P1 P1 P1 P1 P1 P1 ;
FB Set Read Answer
FREQUENCY VFO SUB-SIDE 1 2 3 4 5 6 7 8 9 10 11 12 P1 000030000 – 470000000 (Hz) F B P1 P1 P1 P1 P1 P1 P1 P1 P1 ;
1 2 3 4 5 6 7 8 9 10 11 12
FB ;
1 2 3 4 5 6 7 8 9 10 11 12
F B P1 P1 P1 P1 P1 P1 P1 P1 P1 ;
FN
FINE TUNING
Set Read
1 2 3 4 5 6 7 8 9 10 P1 0: “OFF”
F N P1 ;
1: Fine Tuning “ON”
1 2 3 4 5 6 7 8 9 10
2: Fast Tuning “ON”
FN ;
1 2 3 4 5 6 7 8 9 10
Answer F N P1 ;
FR
FUNCTION RX
Set
1 2 3 4 5 6 7 8 9 10 P1 00: Dual receive
F R P1 P1 ;
01: Single receive
Read
1 2 3 4 5 6 7 8 9 10
FR ;
1 2 3 4 5 6 7 8 9 10
Answer F R P1 P1 ;
FT
FUNCTION TX
Set
1 2 3 4 5 6 7 8 9 10 P1 0: MAIN-side Transmitter
F T P1 ;
1: SUB-side Transmitter
Read
1 2 3 4 5 6 7 8 9 10
FT ;
1 2 3 4 5 6 7 8 9 10
Answer F T P1 ;
16
CAT (Computer Aided Transceiver) Operation
GP Set
Read
GP OUT
1 2 3 4 5 6 7 8 9 10 P1 0: GP OUT A “LOW”
1: GP OUT A “HIGH”
G P P1 P2 P3 P4 ;
P2 0: GP OUT B “LOW”
1: GP OUT B “HIGH”
1 2 3 4 5 6 7 8 9 10 P3 0: GP OUT C “LOW”
1: GP OUT C “HIGH”
GP ;
P4 0: GP OUT D “LOW”
1: GP OUT D “HIGH”
1 2 3 4 5 6 7 8 9 10 *5V CMOS Level, Max. 3 mA
+13.8V GP OUT A
GND GP OUT D
GP OUT B GP OUT C
Answer G P P1 P2 P3 P4 ;
Set to “GPO” in the setting menu [OPERATION SETTING] [GENERAL] [TUN/LIN PORT SELECT]. (Factory setting: “OPTION”)
GT
AGC FUNCTION
Set
1 2 3 4 5 6 7 8 9 10 P1 0: MAIN-side
G T P1 P2 ;
1: SUB-side P2 0: AGC “OFF”
Read
1 2 3 4 5 6 7 8 9 10
G T P1 ;
1: AGC “FAST” 2: AGC “MID”
1 2 3 4 5 6 7 8 9 10
Answer
3: AGC “SLOW” 4: AGC “AUTO”
G T P1 P3 ;
P3 0: AGC “OFF” 1: AGC “FAST” 2: AGC “MID” 3: AGC “SLOW” 4: AGC “AUTO – FAST” 5: AGC “AUTO – MID” 6: AGC “AUTO – SLOW”
ID
IDENTIFICATION
Set
1 2 3 4 5 6 7 8 9 10 P1 0840 (Fixed)
Read
1 2 3 4 5 6 7 8 9 10
ID;
1 2 3 4 5 6 7 8 9 10
Answer I D P1 P1 P1 P1 ;
IF Set Read
Answer
INFORMATION VFO MAIN-SIDE
1 2 3 4 5 6 7 8 9 10 P1 00000: VFO or MT or QMB (5 Bytes) 00001 – 00999: (Memory Channel)
P-01L – P-50U: (PMS)
50001 – 50020: (5MHz BAND)
1 2 3 4 5 6 7 8 9 10
EMGCH: (EMERGENCY CH)
P2 VFO Frequency (Hz) (9 Bytes)
IF;
P3 Clarifier Direction +: Plus Shift, -: Minus Shift (1 Bytes) Clarifier Offset: 0000 – 9990 (Hz) (4 Bytes)
1 2 3 4 5 6 7 8 9 10 P4 0: RX CLAR “OFF” 1: RX CLAR “ON” P5 0: TX CLAR “OFF” 1: TX CLAR “ON”
I
F
P1
P1
P1
P1
P1
P2
P2
P2
P6 MODE 0:5: AM
1: LSB 6: RTTY-L
2: USB 7: CW-L
3: CW-U 8: DATA-L
4: FM 9: RTTY-U
11 12 13 14 15 16 17 18 19 20
A: DATA-FM B: FM-N F: DATA-FM-N G: –
C: DATA-U D: AM-N
E: PSK
H: C4FM-DN I: C4FM-VW J: –
P2
P2
P2
P2
P2
P2
P3
P3
P3
P3
P7 0: VFO 4: –
1: Memory Channel 5: PMS
2: Memory Tune
3: Quick Memory Bank (QMB)
P8 0: OFF 1: CTCSS ENC/DEC 2: CTCSS ENC 3: DCS 4: PR FREQ
21 22 23 24 25 26 27 28 29 30
5: REV TONE
P9 00: (Fixed) P3 P4 P5 P6 P7 P8 P9 P9 P10 ; P10 0: Simplex 1: Plus Shift 2: Minus Shift
IS Set Read Answer
IF-SHIFT
123456789
I S P1 P2 P3 P4 P4 P4 P4
123456789
I S P1 ;
123456789
I S P1 P2 P3 P4 P4 P4 P4
10 P1 0: MAIN-side
;
1: SUB-side
10 P2 0: (Fixed) P3 + / –
P4 0000 – 1200 Hz (20 Hz steps) 10
;
KM
KEYING MEMORY
Set
1 2 3 4 5 6 7 ~ n-1 n P1 1 – 5 : Keyer Memory Channel Number K M P1 P2 P2 P2 P2 ~ P2 ; P2 Message Characters (up to 50 characters)
Read
1 2 3 4 5 6 7 8 9 10
K M P1 ;
Answer
1
K
234567
M P1 P2 P2 P2 P2
~ n-1 ~ P2
n
;
17
CAT (Computer Aided Transceiver) Operation
KP
KEY PITCH FREQUENCY
Set
1 2 3 4 5 6 7 8 9 10 P1 00: 300 Hz – 75: 1050 Hz (10Hz steps) K P P1 P1 ;
Read
1 2 3 4 5 6 7 8 9 10
KP ;
Answer
1
K
234
P P1 P1
5
;
6
7
8
9 10
KR
KEYER
Set
1 2 3 4 5 6 7 8 9 10 P1 0: CW KEYER “OFF”
K R P1 ;
1: CW KEYER “ON”
Read
1 2 3 4 5 6 7 8 9 10
KR ;
1 2 3 4 5 6 7 8 9 10
Answer K R P1 ;
KS
KEYER SPEED
Set
1 2 3 4 5 6 7 8 9 10 P1 004 – 060 (WPM) K S P1 P1 P1 ;
Read
1 2 3 4 5 6 7 8 9 10
KS ;
1 2 3 4 5 6 7 8 9 10
Answer K S P1 P1 P1 ;
KY
CW KEYING MEMORY PLAY
Set Read
1 2 3 4 5 6 7 8 9 10 P1 0: CW TEXT Memory 1: CW MESSAGE Memory
K Y P1 P2 ;
P2 0: STOP
1 2 3 4 5 6 7 8 9 10
1: CW TEXT/MESSAGE Memory “1” Playback 2: CW TEXT/MESSAGE Memory “2” Playback
3: CW TEXT/MESSAGE Memory “3” Playback
1 2 3 4 5 6 7 8 9 10
Answer
4: CW TEXT/MESSAGE Memory “4” Playback 5: CW TEXT/MESSAGE Memory “5” Playback
LK
LOCK
Set
1 2 3 4 5 6 7 8 9 10 P1 0: Lock “OFF”
L K P1 ;
1: Lock “ON”
Read
1 2 3 4 5 6 7 8 9 10
LK ;
Answer
1
L
23
K P1
4
;
5
6
7
8
9 10
LM
LOAD MESSAGE
1 2 3 4 5 6 7 8 9 10 P1 0: MESSAGE (DVS) 1: RECORD
Set
P2 P1=0 (MESSAGE)
L M P1 P2 ;
0: Play Stop/ Recording Stop
1: Select CH “1”
1 2 3 4 5 6 7 8 9 10
2: Select CH “2”
Read
L M P1 ;
3: Select CH “3” 4: Select CH “4”
5: Select CH “5”
1 2 3 4 5 6 7 8 9 10
P1=1 (RECORD)
Answer
0: Recording Stop
L M P1 P2 ;
1: Recording Start
MA Set Read Answer
MEMORY CHANNEL to VFO MAIN-SIDE
1 2 3 4 5 6 7 8 9 10
MA ;
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
18
CAT (Computer Aided Transceiver) Operation
MB Set Read Answer
MEMORY CHANNEL to VFO SUB-SIDE
1 2 3 4 5 6 7 8 9 10
MB ;
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
MC
MEMORY CHANNEL
123456789
Set
M C P1 P2 P2 P2 P2 P2 ;
Read
123456789
MC ;
123456789
Answer M C P1 P2 P2 P2 P2 P2 ;
10 P1 0: MAIN-side
1: SUB-side
10 P2 00001 – 00099: (Memory Channel) P-01L – P-50U: (PMS)
50000 – 50020: (5MHz BAND)
10
EMGCH: (EMERGENCY CH)
MD
OPERATING MODE
Set
1 2 3 4 5 6 7 8 9 10 P1 0: MAIN-side
M D P1 P2 ;
1: SUB-side
Read
1 2 3 4 5 6 7 8 9 10 P2 MODE 0:-
1: LSB
M D P1 ;
5: AM
6: RTTY-L
A: DATA-FM B: FM-N
1 2 3 4 5 6 7 8 9 10
Answer M D P1 P2 ;
F: DATA-FM-N G: –
2: USB 7: CW-L C: DATA-U H: C4FM-DN
3: CW-U 8: DATA-L D: AM-N I: C4FM-VW
4: FM 9: RTTY-U E: PSK J: –
MG
MIC GAIN
Set
1 2 3 4 5 6 7 8 9 10 P1 000 – 100 M G P1 P1 P1 ;
Read
1 2 3 4 5 6 7 8 9 10
MG ;
1 2 3 4 5 6 7 8 9 10
Answer M G P1 P1 P1 ;
ML
MONITOR LEVEL
Set Read
1 2 3 4 5 6 7 8 9 10 P1 0: MONI “ON/OFF”
M L P1 P2 P2 P2 ;
1: MONI Level
1
2
3
4
5
6
7
8
9
10
P2 P1=0 000: MONI “OFF”
M L P1 ;
001: MONI “ON”
1 2 3 4 5 6 7 8 9 10
Answer M L P1 P2 P2 P2 ;
P1=1 000 – 100
MR Set Read
Answer
MEMORY CHANNEL READ
1234567
1234567
M R P0 P0 P0 P0 P0
1234567
M R P1 P1 P1 P1 P1
11 12 13 14 15 16 17
P2 P2 P2 P2 P2 P2 P3
21 22 23 24 25 26 27
P3 P4 P5 P6 P7 P8 P9
8 9 10
8 9 10
;
8 9 10
P2 P2 P2
18 19 20
P3 P3 P3
28 29 30
P9 P10 ;
P0 00000: VFO or MT or QMB (5 Bytes)
00001 – 00999: (Memory Channel)
P-01L – P-50U: (PMS)
50001 – 50020: (5MHz BAND)
EMGCH: (EMERGENCY CH)
P1 00000: VFO or MT or QMB (5 Bytes)
00001 – 00999: (Memory Channel)
P-01L – P-50U: (PMS)
50001 – 50020: (5MHz BAND)
EMGCH: (EMERGENCY CH)
P2 VFO Frequency (Hz) (9 Bytes)
P3 Clarifier Direction +: Plus Shift, -: Minus Shift (1 Bytes)
Clarifier Offset: 0000 – 9990 (Hz) (4 Bytes)
P4 0: RX CLAR “OFF” 1: RX CLAR “ON”
P5 0: TX CLAR “OFF” 1: TX CLAR “ON”
P6 MODE 0:-
1: LSB
2: USB
3: CW-U
4: FM
5: AM
6: RTTY-L 7: CW-L
8: DATA-L 9: RTTY-U
A: DATA-FM B: FM-N
C: DATA-U D: AM-N
E: PSK
F: DATA-FM-N G: –
H: C4FM-DN I: C4FM-VW J: –
P7 0: VFO 1: Memory Channel 2: Memory Tune 3: Quick Memory Bank (QMB)
4: –
5: PMS
P8 0: OFF 1: CTCSS ENC/DEC 2: CTCSS ENC 3: DCS 4: PR FREQ
5: REV TONE
P9 00: (Fixed)
P10 0: Simplex 1: Plus Shift 2: Minus Shift
19
CAT (Computer Aided Transceiver) Operation
MS
METER SW
Set Read
1 2 3 4 5 6 7 8 9 10 P1 MAIN-side
M S P1 P2 ;
0: PO 1: COMP 2: ALC 3: VDD 4: ID 5: SWR
1 2 3 4 5 6 7 8 9 10 P2 SUB-side 0: PO 1: COMP 2: ALC 3: VDD 4: ID 5: SWR
MS ;
1 2 3 4 5 6 7 8 9 10
Answer M S P1 P2 ;
MT
MEMORY CHANNEL TAG WRITE
Set Read
1 2 3 4 5 6 7 8 9 10 P0 00001 – 00099: (Memory Channel)
M T P0 P0 P0 P0 P0 P1 P1 P1
P-01L – P-50U: (PMS)
11 12 13 14 15 16 17 18 19
P1 P1 P1 P1 P1 P1 P1 P1 P1
20
;
50001 – 50009: (5MHz BAND) EMGCH: (EMERGENCY CH) P1 TAG Characters (up to 12 characters) (ASCII)
1 2 3 4 5 6 7 8 9 10
M T P0 P0 P0 P0 P0 ;
1 2 3 4 5 6 7 8 9 10
Answer M T P0 P0 P0 P0 P0 P1 P1 P1
11 12 13 14 15 16 17 18 19 20
P1 P1 P1 P1 P1 P1 P1 P1 P1 ;
MW Set
Read Answer
MEMORY CHANNEL WRITE
1234567
M W P1 P1 P1 P1 P1
11 12 13 14 15 16 17
P2 P2 P2 P2 P2 P2 P3
21 22 23 24 25 26 27
P3 P4 P5 P6 P7 P8 P9
1234567
1234567
8 9 10
P2 P2 P2
18 19 20
P3 P3 P3
28 29 30
P9 P10 ;
8 9 10
8 9 10
P1 00000: –
00001 – 00999: (Memory Channel)
P-01L – P-50U: (PMS)
P2 VFO Frequency (Hz) (9 Bytes)
P3 Clarifier Direction +: Plus Shift, -: Minus Shift (1 Bytes)
Clarifier Offset: 0000 – 9990 (Hz) (4 Bytes)
P4 0: RX CLAR “OFF” 1: RX CLAR “ON”
P5 0: TX CLAR “OFF” 1: TX CLAR “ON”
P6 MODE 0:-
1: LSB
2: USB
3: CW-U
4: FM
5: AM
6: RTTY-L 7: CW-L
8: DATA-L 9: RTTY-U
A: DATA-FM B: FM-N
C: DATA-U D: AM-N
E: PSK
F: DATA-FM-N G: –
H: C4FM-DN I: C4FM-VW J: –
P7 0: VFO 1: Memory Channel 2: Memory Tune 3: Quick Memory Bank (QMB)
4: –
5: PMS
P8 0: OFF 1: CTCSS ENC/DEC 2: CTCSS ENC 3: DCS 4: PR FREQ
5: REV TONE
P9 00: (Fixed)
P10 0: Simplex 1: Plus Shift 2: Minus Shift
MX
MOX
Set
1 2 3 4 5 6 7 8 9 10 P1 0: MOX “OFF”
M X P1 ;
1: MOX “ON”
Read
1 2 3 4 5 6 7 8 9 10
MX ;
1 2 3 4 5 6 7 8 9 10
Answer M X P1 ;
MZ
SPLIT MEMORY
Set Read
1 2 3 4 5 6 7 8 9 10 P1 00000: VFO, MT, QMB mode
M Z P1 P1 P1 P1 P1 P2 P3 P3
00001 – 00999: Memory channel
11 12 13 14 15 16 17 18 19 20
P-01L – P-50U: PMS channel (P-01L, P-01U, P-02L, P-02U —— P-50L, P50U)
P3 P3 P3 P3 P3 P3 P3 ;
P2 0: SPLIT memory “OFF” 1: SPLIT memory “ON”
1 2 3 4 5 6 7 8 9 10 P3 000030000 – 470000000 Hz
M Z P1 P1 P1 P1 P1 ;
1 2 3 4 5 6 7 8 9 10
Answer M Z P1 P1 P1 P1 P1 P2 P3 P3
11 12 13 14 15 16 17 18 19 20
P3 P3 P3 P3 P3 P3 P3 ;
NA
NARROW
Set Read
1 2 3 4 5 6 7 8 9 10 P1 0: MAIN-side
N A P1 P2 ;
1: SUB-side
1 2 3 4 5 6 7 8 9 10 P2 0: NARROW “OFF”
N A P1 ;
1: NARROW “ON”
Answer
1
N
234
A P1 P2
5
;
6
7
8
9 10
20
CAT (Computer Aided Transceiver) Operation
NL
NOISE BLANKER LEVEL
Set Read
1 2 3 4 5 6 7 8 9 10 P1 0: MAIN-side
N L P1 P2 P2 P2 ;
1: SUB-side
1 2 3 4 5 6 7 8 9 10 P2 000: OFF
N L P1 ;
001 – 010: (NB Level)
1 2 3 4 5 6 7 8 9 10
Answer N L P1 P2 P2 P2 ;
OI Set Read
Answer
OPPOSITE BAND INFORMATION (SUB-SIDE)
1 2 3 4 5 6 7 8 9 10 P1 00000: VFO or MT or QMB (5 Bytes) 00001 – 00999: (Memory Channel)
P-01L – P-50U: (PMS)
50001 – 50020: (5MHz BAND)
1 2 3 4 5 6 7 8 9 10
EMGCH: (EMERGENCY CH)
P2 VFO Frequency (Hz) (9 Bytes)
OI ;
P3 Clarifier Direction +: Plus Shift, -: Minus Shift (1 Bytes) Clarifier Offset: 0000 – 9990 (Hz) (4 Bytes)
1 2 3 4 5 6 7 8 9 10 P4 0: RX CLAR “OFF” 1: RX CLAR “ON” P5 0: TX CLAR “OFF” 1: TX CLAR “ON”
O
I
P1
P1
P1
P1
P1
P2
P2
P2
P6 MODE 0:5: AM
1: LSB 6: RTTY-L
2: USB 7: CW-L
3: CW-U 8: DATA-L
4: FM 9: RTTY-U
11 12 13 14 15 16 17 18 19 20
A: DATA-FM B: FM-N F: DATA-FM-N G: –
C: DATA-U D: AM-N
E: PSK
H: C4FM-DN I: C4FM-VW J: –
P2
P2
P2
P2
P2
P2
P3
P3
P3
P3
P7 0: VFO 4: –
1: Memory Channel 5: PMS
2: Memory Tune
3: Quick Memory Bank (QMB)
P8 0: OFF 1: CTCSS ENC/DEC 2: CTCSS ENC 3: DCS 4: PR FREQ
21 22 23 24 25 26 27 28 29 30
5: REV TONE
P9 00: (Fixed) P3 P4 P5 P6 P7 P8 P9 P9 P10 ; P10 0: Simplex 1: Plus Shift 2: Minus Shift
OS
OFFSET (REPEATER SHIFT)
Set Read
1 2 3 4 5 6 7 8 9 10 P1 0: MAIN-side
O S P1 P2 ;
1: SUB-side
1
2
3
4
5
6
7
8
9
10
P2 0: Simplex 1: Plus Shift (+ Offset)
O S P1 ;
2: Minus Shift (- Offset)
12345
Answer O S P1 P2 ;
6
7
8
9 10
3: ARS (Automatic Repeater Shift)
*: This command can be activated only with an FM mode.
PA
PRE-AMP (IPO)
1 2 3 4 5 6 7 8 9 10 P1 0: HF/50MHz band
Set
1: VHF band
P A P1 P2 ;
2: UHF band
Read
P2 P1=0 0: IPO (HF/50)
1 2 3 4 5 6 7 8 9 10
1: AMP1 (HF/50)
P A P1 ;
2: AMP2 (HF/50) P1=1 0: VHF Pre AMP “OFF”
1 2 3 4 5 6 7 8 9 10
Answer P A P1 P2 ;
1: VHF Pre AMP “ON” P1=2 0: UHF Pre AMP “OFF”
1: UHF Pre AMP “ON”
PB
PLAY BACK
Set Read
1 2 3 4 5 6 7 8 9 10 P1 0: (Fixed) P2 0: MESSAGE Playback / Recording Stop
P B P1 P2 ;
1: MESSAGE CH “1” Playback Start
1 2 3 4 5 6 7 8 9 10
2: MESSAGE CH “2” Playback Start 3: MESSAGE CH “3” Playback Start
P B P1 ;
4: MESSAGE CH “4” Playback Start 5: MESSAGE CH “5” Playback Start
1 2 3 4 5 6 7 8 9 10
Answer P B P1 P2 ;
PC
POWER CONTROL
Set Read
1 2 3 4 5 6 7 8 9 10 P1 1: FTX-1 field head
P C P1 P2 P2 P2 ;
2: SPA-1
1 2 3 4 5 6 7 8 9 10 P2 P1=1: 005 – 010 (W)
PC ;
P1=2: 005 – 100 (W)
Answer
1
P
23456
C P1 P2 P2 P2
7
;
8
9 10
21
CAT (Computer Aided Transceiver) Operation
PL Set Read Answer
SPEECH PROCESSOR LEVEL
12345678
P L P1 P1 P1 ;
12345678
PL ;
12345678
P L P1 P1 P1 ;
9 10 P1 000: “OFF”, 001 -100 9 10 9 10
PR
SPEECH PROCESSOR
Set Read
1 2 3 4 5 6 7 8 9 10 P1 0: Speech Processor
P R P1 P2 ;
1: Parametric Microphone Equalizer
1 2 3 4 5 6 7 8 9 10 P2 1: “OFF”
P R P1 ;
2: “ON”
1 2 3 4 5 6 7 8 9 10
Answer P R P1 P2 ;
PS
POWER SWITCH
Set
1 2 3 4 5 6 7 8 9 10 P1 0: POWER “OFF” P S P1 ;
Read
1 2 3 4 5 6 7 8 9 10
PS ;
Answer
1
P
23
S P1
4
;
5
6
7
8
9 10
QI Set Read
QMB STORE
1 2 3 4 5 6 7 8 9 10
QI ;
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Answer
QR Set Read
QMB RECALL
1 2 3 4 5 6 7 8 9 10
QR ;
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Answer
RA
RF ATTENUATOR
Set Read
1 2 3 4 5 6 7 8 9 10 P1 0: (Fixed)
R A P1 P2 ;
P2 0: “OFF”
1 2 3 4 5 6 7 8 9 10
1: “ON”
R A P1 ;
1 2 3 4 5 6 7 8 9 10
Answer R A P1 P2 ;
RG
RF GAIN
Set Read
1 2 3 4 5 6 7 8 9 10 P1 0: MAIN-side
R G P1 P2 P2 P2 ;
1: SUB-side
1 2 3 4 5 6 7 8 9 10 P2 000 – 255
R G P1 ;
Answer
1
R
23456
G P1 P2 P2 P2
7
;
8
9 10
RI Set Read Answer
RADIO INFORMATION
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
R I P1 ;
1 2 3 4 5 6 7 8 9 10
R I P1 P2 P3 P4 P5 P6 P7 P8
11 P1 0: (Fixed) P2 0: Normal 1: Hi-SWR P3 0: Stop 1: Recording 2: Playing
11 P4 0: RX 1: TX 2: TX INHIBIT P5 0: (Fixed) P6: 0: Antenna tuner: Tuning stopped 1:Antenna tuner: Tuning
11 P7: 0: Scan Stop 1:Scanning 2:Scan Pause ; P8: 0: SQL Closed 1: SQL Open (BUSY)
22
CAT (Computer Aided Transceiver) Operation
RL
NOISE REDUCTION LEVEL (DNR)
123456789
Set
R L P1 P2 P2 ;
Read
123456789
R L P1 ;
123456789
Answer R L P1 P2 P2 ;
10 P1 0: MAIN-side 1: SUB-side
10 P2 00: “OFF”, 01 -10
10
RM Set Read Answer
READ METER
123456789
123456789
R M P1 ;
123456789
R M P1 P2 P2 P2 P3 P3 P3
10 P1=0
P2: Meter 000 – 255 (MAIN-side)
10
P3: Meter 000 – 255 (SUB-side)
P1= 1: S (Main-side) 2: S (SUB-side) 3: COMP
6: SWR
7: IDD
8: VDD
10
P2: 000 – 255
;
P3: 000 (Fixed)
4: ALC
5: PO
SC
SCAN
Set
1 2 3 4 5 6 7 8 9 10 P1 0: MAIN-side
S C P1 P2 ;
1: SUB-side
Read
1 2 3 4 5 6 7 8 9 10 P2 0: Scan “OFF”
SC ;
1: Scan “ON” (UP ward) 2: Scan “ON” (DOWN ward)
Answer
1
S
234
C P1 P2
5
;
6
7
8
9 10
SD
CW BREAK-IN DELAY TIME
Set
1 2 3 4 5 6 7 8 9 10 00: 30
01: 50
02: 100
S D P1 P1 ;
06: 300 – 33: 3000 (msec)
Read
1 2 3 4 5 6 7 8 9 10 NOTE: 06 to 33: 100 msec steps SD ;
1 2 3 4 5 6 7 8 9 10
Answer S D P1 P1 ;
03: 150
04: 200
05: 250
SF
FUNC KNOB FUNCTION
Set
1 2 3 4 5 6 7 8 9 10 P1 0: FUNC knob
S F P1 P2 ;
P2 0: –
1: SCOPE LEVEL 2: PEAK
3: COLOR
Read
1 2 3 4 5 6 7 8 9 10
S F P1 ;
1 2 3 4 5 6 7 8 9 10
Answer S F P1 P2 ;
4: CONTRAST 8: PROC LEVEL C: G: CW PITCH
5: DIMMER 9: AMC LEVEL D: RF POWER H: BK-DELAY
6: A: VOX GAIN E: MONI LEVEL
7: MIC GAIN B: VOX DELAY F: CW SPEED
23
CAT (Computer Aided Transceiver) Operation
SH
WIDTH
Set Read
1 2 3 4 5 6 7 8 9 10 P1 0: MAIN-side
S H P1 P2 P3 P3 ;
1: SUB-side
1 2 3 4 5 6 7 8 9 10 P2 0: (Fixed)
S H P1 ;
P3 00 – 23 (See Table 5)
1 2 3 4 5 6 7 8 9 10
Answer S H P1 P2 P3 P3 ;
Command
P3
00 (Default) 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
LSB / USB
(Default)* 300 Hz 400 Hz 600 Hz 850 Hz 1100 Hz
1200 Hz 1500 Hz 1650 Hz 1800 Hz 1950 Hz 2100 Hz 2250 Hz 2400 Hz 2450 Hz 2500 Hz 2600 Hz 2700 Hz 2800 Hz 2900 Hz 3000 Hz 3200 Hz 3500 Hz 4000 Hz
Table 5 (Bandwidth Chart)
Bandwidth
CW-L / CW-U / DATA-L / DATA-U / RTTY-L / RTTY-U
PSK
AM-N
(Default)* 50 Hz
6000 Hz (Fixed)
100 Hz
–
150 Hz
–
200 Hz
–
250 Hz
–
300 Hz
–
350 Hz
–
400 Hz
–
450 Hz
–
500 Hz
–
600 Hz
–
800 Hz
–
1200 Hz
–
1400 Hz
–
1700 Hz
–
2000 Hz
–
2400 Hz
–
3000 Hz
–
3200 Hz
–
3500 Hz
–
4000 Hz
–
–
–
–
–
AM / FM-N / DATA-FM-N
FM / DATA-FM
9000 Hz (Fixed) –
16000 Hz (Fixed) –
*(The default bandwidth varies depending on the selected mode.)
SM
S-METER READING
Set
1 2 3 4 5 6 7 8 9 10 P1 0: MAIN-side 1: SUB-side
Read
1 2 3 4 5 6 7 8 9 10 P2 000 – 255 S M P1 ;
1 2 3 4 5 6 7 8 9 10
Answer S M P1 P2 P2 P2 ;
SQ
SQUELCH LEVEL
Set Read
1 2 3 4 5 6 7 8 9 10 P1 0: MAIN-side
S Q P1 P2 P2 P2 ;
1: SUB-side
1 2 3 4 5 6 7 8 9 10 P2 000 – 255
S Q P1 ;
1 2 3 4 5 6 7 8 9 10
Answer S Q P1 P2 P2 P2 ;
24
CAT (Computer Aided Transceiver) Operation
SS Set Read Answer
SPECTRUM SCOPE
123456789
S S P1 P2 P3 P4 P5 P6 P7
123456789
S S P1 P2 ;
123456789
S S P1 P2 P3 P4 P5 P6 P7
10 P1 0: (Fixed)
; P2 0: SPEED 1: PEAK 2: MARKER 3: COLOR 4: LEVEL 5: SPAN
10
6: MODE 7: AF-FFT/OSCILLOSCOPE
P2=0 (SPEED):
10
P3 0: SLOW1 1: SLOW2 2: FAST1 3: FAST2 4: FAST3 5: STOP P4 – P7: 0: (Fixed)
;
P2=1 (PEAK):
P3 0: LV1 1: LV2 2: LV3 3: LV4 4: LV5
P4 – P7: 0: (Fixed)
P2=2 (MARKER): P3 0: MARKER “OFF” 1: MARKER “ON”
P4 – P7: 0: (Fixed)
P2=3 (COLOR):
P3 0: COLOR-1 – A: COLOR-11
P4 – P7: 0: (Fixed)
P2=4 (LEVEL):
P3 – P7: -30.0 – -00.0 or +00.0 – +30.0 (0.5 dB steps, 5 bytes)
P2=5 (SPAN):
P3 0: –
1: –
2: 5 kHz 3: 10 kHz 4: 20 kHz 5: 50 kHz
6: 100 kHz 7: 200 kHz 8: 500 kHz 9: 1 MHz
P4 – P7: 0: (Fixed)
P2=6 (MODE): P3 0: 3DSS CENTER
1: 3DSS CURSOR
2: 3DSS FIX
3: –
4: W/F CENTER (NORMAL) 5: –
6: –
7: W/F CURSOR (NORMAL) 8: –
9: –
A: W/F FIX (NORMAL)
B: –
P4 – P7: 0: (Fixed)
P2=7 (AF-FFT/OSCILLOSCOPE):
P3 0: AF-FFT (ATT=0dB) 1: AF-FFT (ATT=10dB) P4 0: OSC Level RX (0dB) 1: OSC Level RX (10dB) P5 0: OSC Time (1 msec) 1: OSC Time (3 msec)
2: AF-FFT (ATT=20dB) 2: OSC Level RX (20dB) 2: OSC Time (10 msec)
3: OSC Time (30 msec) 4: OSC Time (100 msec) P6 0: OSC Level TX (0dB) 1: OSC Level TX (10dB) P7 0: (Fixed)
5: OSC Time (300 msec) 2: OSC Level TX (20dB)
ST
SPLIT
Set
1 2 3 4 5 6 7 8 9 10 P1 0: SPLIT “OFF”
S T P1 ;
1: SPLIT “ON”
Read
1 2 3 4 5 6 7 8 9 10
ST ;
1 2 3 4 5 6 7 8 9 10
Answer S T P1 ;
SV Set Read
SWAP VFO 1 2 3 4 5 6 7 8 9 10 Changes the MAIN-side and SUB-side SV ;
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Answer
TS
TXW
Set
1 2 3 4 5 6 7 8 9 10 P1 0: TXW “OFF”
T S P1 ;
1: TXW “ON”
Read
1 2 3 4 5 6 7 8 9 10
TS ;
1 2 3 4 5 6 7 8 9 10
Answer T S P1 ;
TX
TX SET
Set Read
1 2 3 4 5 6 7 8 9 10 P1 0: RADIO TX “OFF”, CAT TX “OFF”
T X P1 ;
1: RADIO TX “OFF”, CAT TX “ON”
1 2 3 4 5 6 7 8 9 10
2: RADIO TX “ON”, CAT TX “OFF” (Answer)
TX ;
1 2 3 4 5 6 7 8 9 10
Answer T X P1 ;
25
CAT (Computer Aided Transceiver) Operation
UP Set Read
MIC UP
1 2 3 4 5 6 7 8 9 10
UP ;
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Answer
VD Set Read Answer
VOX DELAY TIME / DATA VOX DELAY TIME
1 2 3 4 5 6 7 8 9 10 P1 00: 30 msec 01: 50 msec 02: 100 msec 03: 150 msec 04: 200 msec
V D P1 P1 ;
05: 250 msec 06: 300 msec – 33: 3000 msec (06 – 33: 10 msec multiples)
1 2 3 4 5 6 7 8 9 10 NOTE: VD command sets individual parameter values with the setting values “MIC” and
VD ;
“USB or BLUETOOTH” in the menu items [OPERATION SETTING] [TX GNRL]
1 2 3 4 5 6 7 8 9 10 [VOX SELECT].
V D P1 P1 ;
VE
FIRMWARE VERSION
12345678
Set
Read
12345678
V E P1 ;
12345678
Answer V E P1 P2 P2 P2 P2 ;
9 10 P1 0: MAIN CPU 1: DISPLAY CPU 2: SDR 3: DSP 4: SPA-1 5: FC-80 P2 XX-XX (Binary Coded Decimal)
9 10
9 10
VG
VOX GAIN
Set
1 2 3 4 5 6 7 8 9 10 P1 000 – 100 V G P1 P1 P1 ;
Read
1 2 3 4 5 6 7 8 9 10
VG ;
1 2 3 4 5 6 7 8 9 10
Answer V G P1 P1 P1 ;
VM Set Read
MAIN-SIDE TO MEMORY CHANNEL
1 2 3 4 5 6 7 8 9 10
VM ;
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Answer
VM
VFO / MEMORY CHANNEL
Set Read
1 2 3 4 5 6 7 8 9 10 P1 0: MAIN-side
V M P1 P2 P2 ;
1: SUB-side
1 2 3 4 5 6 7 8 9 10 P2 00: VFO
V M P1 ;
21: P-01L – P-50U
1 2 3 4 5 6 7 8 9 10
Answer V M P1 P2 P2 ;
10: MT 51: 5MHz Band Memory
11: Memory 91: EMG
20: PMS
VS
VFO SELECT
Set
1 2 3 4 5 6 7 8 9 10 P1 0: MAIN-side TX/RX, SUB-side RX
V S P1 ;
;
1: MAIN-side RX, SUB-side TX/RX
Read
1 2 3 4 5 6 7 8 9 10
VS ;
1 2 3 4 5 6 7 8 9 10
Answer V S P1 ;
VX
VOX STATUS
Set
1 2 3 4 5 6 7 8 9 10 P1 0: VOX “OFF”
V X P1 ;
;
1: VOX “ON”
Read
1 2 3 4 5 6 7 8 9 10
VX ;
Answer
1
V
23
X P1
4
;
5
6
7
8
9 10
26
CAT (Computer Aided Transceiver) Operation
ZI Set Read
ZERO IN
1 2 3 4 5 6 7 8 9 10 (CW AUTO ZERO IN Function)
Z I P1 ;
P1 0: MAIN-side
1 2 3 4 5 6 7 8 9 10
1: SUB-side
1 2 3 4 5 6 7 8 9 10
Answer
27
Copyright 2025 YAESU MUSEN CO., LTD. All rights reserved.
No portion of this manual may be reproduced without the permission of YAESU MUSEN CO., LTD.
YAESU MUSEN CO., LTD.
Omori Bellport Building D-3F 6-26-3 Minami-Oi, Shinagawa-ku, Tokyo, 140-0013, Japan
YAESU USA
6125 Phyllis Drive, Cypress, CA 90630, U.S.A.
YAESU UK
Unit 4, Concorde Park, Concorde Way, Segensworth North, Fareham, Hampshire PO15 5FG, United Kingdom
2507-A
Documents / Resources
![]() |
YAESU FTX-1 Series Field Operation and 100W Base Station [pdf] Instruction Manual FTX-1 Series Field Operation and 100W Base Station, FTX-1 Series, Field Operation and 100W Base Station, Operation and 100W Base Station, 100W Base Station, Base Station |