Product Information
Product Model | HA5041 |
---|---|
Product Characteristics | Plug-in terminal output, plate installation, wrong wiring will cause product damage, measure the DC and AC pulse current, output in a linear relationship with the primary detection current, the output signal can directly enter the automatic control equipment or PLC port. |
Technical Index | Electrical Parameters: The following parameters are typical values. The actual values shall be subject to the actual measurement of the product.IPn: Rated input – A IPM: Input measurement range – A IOUT: Rated output – mA Wiring diagram: X Accuracy |
Product Picture | ![]() |
Website | www.poweruc.pl |
Product Usage Instructions
To use the HA5041 product, please follow these instructions:
- Ensure proper installation of the product by plugging it into the appropriate terminal.
- Make sure to correctly wire the product to avoid any damage to the device.
- Measure the DC or AC pulse current using the product.
- The output signal of the product is in a linear relationship with the primary detection current.
- The output signal can be directly connected to automatic control equipment or PLC port.
Note:
The product picture printing is for reference only. The actual product may vary.
Product characteristics
Plug-in terminal output, plate installation, wrong wiring will cause product damage,measure the DC and AC pulse current, output in a linear relationship with the primary detection current,the output signal can directly enter the automatic control equipment or PLC port.
Technical index
- Flame resistance: UL94-V0
- Working temperature: -10℃~+70℃
- Storage temperature: -25℃~+70℃
- Dielectric strength: 3.8KV 50Hz 1min
Electrical parameters:
The following parameters are typical values. The actual values shall be subject to the actual measurement of the product.
I Rated input
Pn |
±1000 | A |
I Input measurement range
PM |
±1500(@Vc=±24V) | A |
I Rate d output
OUT |
±200 | mA |
X Accuracy | ±0.5 | % |
ε Linearity
L |
±0.1 | % |
V Supply voltage(±5%)
C |
±15~±24 | V |
I Current consumption
C |
≤28 | mA+Is |
R Load impedance
L |
> 5 | Ω |
IOE Zero offset TA=25℃ | ≤±0.4 | mA |
T Response time
R |
≤1 | μs |
B W Ban d width | DC~100 | KHz |
N.W Weight | – | g |
Dimensions
Dimensions(in mm±0.5):
Wiring diagram
Terminal definition:
- V-
- M
- V+
Detection:
- Choose the auxiliary power supply with a small ripple (≤20mV)
- Switch on the auxiliary power
- The auxiliary power is connected to the sensor
- The sensor detects the primary current
Connector
- VH-3Y spacing 3.96mm
Documents / Resources
![]() |