WEINMANN C16 WiFi Built-in Digital Room Thermostat
Specifications
- Voltage: 86-51V
- Max. load: 11- 9A
- Standby voltage: 26V
- Temperature range: 86-52°C
- Housing: Standard DIN formats
- Standard colour: 59
- Sensor: Display, Touch-sensitive keys
- Warranty: Manufacturer approval
Product Usage Instructions
Assembly
- Connect the thermostat according to the connection diagram provided.
- Put the frame on it and click the display back into place.
Startup Menu
- The startup menu will be updated automatically after connection.
- Options available in the menu include Clock (CLK), Current temperature, Heating Percentage, Current period (Smart Mode), Key lock, Frost protection mode, and Manual mode.
Wiring Diagram
Keep the maximum load around 90% of the 16A to extend the service life. Follow the wiring diagram provided in the manual for proper installation.
WiFi Connection (C16 WiFi version only)
- Download the App via the QR code or by searching for Warmme in the App Store or Google Play store.
- Create or log in with an existing account in the App.
- Simultaneously press Up and Down on the thermostat.
- Click on Add device in the App after connecting to the thermostat.
- Click Done after the connection is complete.
Function and Operation
- Temporary Temperature: Press Up or Down on the main screen to set a temporary temperature until the next heating period.
- Modes: Press Set up on the main screen to select Smart mode or Manual mode.
Introduction
Study this manual carefully and keep it with the warranty documents. Connection must be carried regulations. Before mounting or dismounting in the meter cupboard. This thermostat can be deeply standard DIN formats. These regulations describe the C16 Basic and the C16 WiFi version.
Technicalspecification
- Voltage : 230V – 50/60 Hz
- Max. load: Max. 16 Amp / 230V
- Standby voltage : C16 Basic: 1W / C16 WiFi: 2W
- Temp. range: +5/+40ºC
- Housing IP21
- Standard colour Polar white (RAL 9010)
- Sensor: Floor sensor and built-in sensor
- Warranty: 2 years manufacturer’s warranty
- Approvals FI / CE
- Manufacturer: MHGroup B.V., Netherlands
Assembly
- Press with your fingers at the top of the display and pull it towards you.
- Connect the thermostat according to the connection diagram (point 4).
- Mount the thermostat on the flush-mounting box.
- Put the frame on it and click the display back into place.
Wiring diagram
Connection must be carried out by a qualified fitter inbyocal regulations. Before mounting or dismounting the thermostat, always switch off the electricity in the meter cupboard.
Recommendation
Keep the maximum load around 90% of the 16A to extend the service life.
FLOOR SENSOR
Floor sensor connection
ROOM OUT SENSOR
External room sensor connection
N1
Heating cable connection wire
L1
Heating cable connection wire
N
Power supply (Neutral)
L
Power supply (Phase)
EARTH
Connect the earth of the heating cable and the earth of the power supply outside the thermostat using the supplied terminal block.
Order
L1 or N1 does not apply.
Explanation of symbols
When the thermostat is connected, turn the on/off switch down to turn the thermostat on. The thermostat is operated using the 3 touch-sensitive buttons on the bottom of the screen and has a series of fixed symbols in the display.
At the first startup, the following settings need to be entered. With the WiFi version it will be updated automatically after connection.
Sensor selection
- Floor sensor
- Room sensor
- Room sensor with a floor sensor limit
- External room sensor
- External room sensor with a floor sensor limit
Limit the floor temperature
For tiled floors up to 35 degrees.
PLEASE NOTE: For wooden floors, set to a maximum of 28 degrees!
Home or office situation (00 – Home 01 -Office)
WiFi Connection (C16 WiFi version only)
- Download the App via the QR code or by searching for “Warmme” in the App Store or Google Play store.
- Start the App and create or log in with an existing account.
- On thermostat: Simultaneously press
and
hold for 5 seconds and check if the WiFi symbol on the thermostat is flashing.
- Click on “Add device” at the bottom of the screen.
- Fill in the WiFi network password on the smartphone and click “Confirm”.
- Click “Done” after the App has connected to the thermostat and the connection is complete.
- You can check, adjust or set the current temperature, turn the thermostat on or off and perform other operations from the main screen on your smartphone.
You can use the App to give other people in your family access to or exclude multiple thermostats. Google Assistant or Amazon Alexa Via a Google or Amazon supported speaker you can set the temperature of your thermostat higher or lower or ask what the current temperature is. Connecting to Google Assistant or Amazon Alexa is explained in the App. In the App, go to your “Profile”, choose “More Services” from the menu and follow the steps.
Function and operation
Temporary temperature
On the main screen, press or
to set the temporary temperature. This temporary temperature is active until the start of the next heating period.
Mode
On the main screen, press to select the following modes:
Smart mode: This is the default mode. The thermostat operates based on the set heating schedule to save energy.
Manual mode: The Thermostat operates based on the manually set temperature.
Frost protection mode: The thermostat will operate with the low set temperature. The maximum is 15 °C.
Key lock
Lock all keys to prevent settings from being changed. On the main screen, press
and
simultaneously for 3 seconds to lock or unlock.
Menu
On the main screen press and hold for 3 seconds to activate the menu.
- CLK Set day and time (8.4.1)
- EVE Set schedule (8.4.2)
- READ Read consumption in % (8.4.3)
- SET Advanced settings (8.4.4)
- END Return to main screen
Clock (CLK)
Day, hour and minutes can be adjusted here via or
With the WiFi version it is automatically updated after connection.
Programming periods (EVE)
In MENU, press or select EVE. The standard program can be adjusted on the thermostat via
each, which can be confirmed with.
- First, choose the day via
or
(This can be done per day or as a cluster, Monday to Friday, and Saturday/Sunday separately).
- Then choose an event:
- The next step is to set the (start or end time).
- Then you can choose the desired temperature. The difference between the desired temperature and the lowering temperature may be approx. 3°C as main heating and max. 5°C as auxiliary heating.
Repeat this until all periods and days have been programmed. If you have a WiFi thermostat, you can do this easily via the App.
Standard program for home use
Standard program for office use:
Consumption (READ)
Displays the warm-up time (in percent) within a given period (1.30 or 365 days). In MENU, press or
to select READ.
Press o to view the previous day’s consumption. Press or
to display the consumption of 1 day, 30 days, or 365 days.
Example
The consumption is 20%, and the installed power is 300 watts
- 20% x 300Watt = 60 Watt consumption per hour.
- 60W x 24 hours = 1.440watts oft consumption per day.
- Press
to return to the main menu.
Advanced Settings (SET)
PLEASE NOTE
Settings in this menu may only be adjusted in consultation with the supplier/installer to prevent unwanted results.
In MENU, press or
to select SET.
- Sensor selection
- Room temp. calibration
- Floor temperature calibration
- Floor temperature limit
- Schedule selection
- Used for heating or cooling
- Intelligent function. This function ensures that the requested temperature has already been reached when the period starts.
- Location: Select Home or Office
- Reset to factory settings
Each setting can be adjusted via or
and confirmed with
O.
Full schedule:
No. | Function | Default setting | Options |
1. |
Sensor selection |
00: Floor sensor |
00: Floor sensor
01: Room sensor 03: External room sensor |
2. | Room temperature calibration | 0.0oC | -5.0oC – 5.0oC |
3. | Floor temperature calibration | 0.0oC | -5.0oC – 5.0oC |
4. | 35.0oC | 20.0oC – 50.0oC | |
5. |
Schedule |
00: 7 days |
00: 7 days
01: Mon to Fri + Sat + Sun |
6. |
Used for |
00: Heating |
00: Heating
01: Cooling (only water-based systems) |
7. |
Intelligent function |
00: On |
00: On |
8. |
Location |
00: Home |
00: Home |
9. |
Reset |
00: No |
00: No
01: Reset |
Open window detection
This function only works if the room sensor or the room sensor with floor sensor limit is connected and selected (see point 6). This function switches the thermostat off automatically for 15 minutes when it detects a rapid drop in temperature.
Error messages
E1: Room sensor fault
E2: Floor sensor fault
E3: Sensor error, external sensor
FAQs
Q: How do I connect the external room sensor?
A: Connect the external room sensor following the instructions provided in the manual. Make sure to select the correct sensor option from the menu during installation.
Q: Can I control multiple thermostats with the App?
A: Yes, you can use the App to control multiple thermostats and give access to other family members for temperature adjustments.
Documents / Resources
![]() |