VIZULO Crocus LED Luminaire Instruction Manual
VIZULO Crocus LED Luminaire

Dimensions

Dimensions

Netto Weight

Netto Weight

Warning icon The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 3.25 m is not expected.

The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.

Warning icon Caution, risk of electrical shock

Warning icon WARNING!

  • Do not touch LED modules!
  • Do not put any tools or other items on LED modules!
  • In case any LED is physically damaged (example shown below) the warranty is void.
    WARNING
  1. Inductions
  2. Inductions
  3. Inductions

Direction of light for asymmetric lens

Direction
Direction

MCB/Inrush current table

Tridonic LED driver (No dim/ Midnight dimming/ DALI)
Standard/High density In-rush current (peak/duration) B10A B13A B16A B20A B25A B32A B40A C10A C13A C16A C20A C25A C32A C40A
6-12 LED, 8-26W 15 A (226 μs) 19 25 30 37 46 59 74 31 41 50 61 76 97 122
12-20 LED, 20-43W 25 A (236 μs) 12 16 20 26 32 41 52 20 26 33 43 53 68 86
20-28 LED, 30-64W 32 A (335 µs) 6 8 10 13 16 20 26 10 13 16 21 26 33 42
28-48 LED, 45-96W 42 A (238 µs) 6 8 10 13 16 20 26 10 13 17 22 27 35 44
48-64 LED, 70-144W 65 A (268 µs) 3 4 5 6 7 9 12 5 7 8 10 12 16 20
64-108 LED, 100-211W 80 A (225 µs) 4 6 8 10 12 16 20 6 10 13 16 20 25 32
108-128 LED, 135-288W 130 A (268 µs) 1 2 2 3 3 4 6 2 3 4 5 6 8 10
128-160 LED, 200-380W 160 A (225 µs) 2 3 4 5 6 8 10 3 5 6 8 10 12 16
 
Eco   B10A B13A B16A B20A B25A B32A B40A C10A C13A C16A C20A C25A C32A C40A
4-4 LED, 9-20W 15 A (226 μs) 19 25 30 37 46 59 74 31 41 50 61 76 97 122
4-8 LED, 20-38W 25 A (236 μs) 12 16 20 26 32 41 52 20 26 33 43 53 68 86
8-12 LED, 30-57W 32 A (335 µs) 6 8 10 13 16 20 26 10 13 16 21 26 33 42
12-24 LED, 45-96W 42 A (238 µs) 6 8 10 13 16 20 26 10 13 17 22 27 35 44
24-32 LED, 70-144W 65 A (268 µs) 3 4 5 6 7 9 12 5 7 8 10 12 16 20
32-52 LED, 100-211W 80 A (225 µs) 4 6 8 10 12 16 20 6 10 13 16 20 25 32
52-64 LED, 135-288W 130 A (268 µs) 1 2 2 3 3 4 6 2 3 4 5 6 8 10
64-96 LED, 200-380W 160 A (225 µs) 2 3 4 5 6 8 10 3 5 6 8 10 12 16
 
Tridonic LED driver (Zhaga)
Standard/High density In-rush current

(peak/duration)

B10A B13A B16A B20A B25A B32A B40A C10A C13A C16A C20A C25A C32A C40A
6-12 LED, 8-26W 15 A (316 μs) 16 21 25 33 41 52 66 26 35 41 55 68 88 110
12-20 LED, 20-43W 20 A (346 μs) 11 14 17 22 27 35 44 18 23 28 36 45 57 72
20-28 LED, 30-64W 28 A (270 µs) 10 13 16 20 25 32 40 16 21 26 33 41 52 66
28-48 LED, 45-96W 38 A (280 µs) 6 8 10 13 16 20 26 10 13 16 21 26 33 42
48-64 LED, 70-144W 56 A (277 µs) 3 4 5 6 7 9 12 5 6 8 10 12 16 20
64-108 LED, 100-211W 85 A (215 µs) 3 4 5 6 7 9 12 5 6 8 10 12 16 20
108-128 LED, 135-288W 112 A (277 µs) 1 2 2 3 3 4 6 2 3 4 5 6 8 10
128-160 LED, 200-380W 170 A (215 µs) 1 2 2 3 3 4 6 2 3 4 5 6 8 10
                               
Eco   B10A B13A B16A B20A B25A B32A B40A C10A C13A C16A C20A C25A C32A C40A
4-4 LED, 9-20W 15 A (316 μs) 16 21 25 33 41 52 66 26 35 41 55 68 88 110
4-8 LED, 20-39W 20 A (346 μs) 11 14 17 22 27 35 44 18 23 28 36 45 57 72
8-12 LED, 30-57W 28 A (270 µs) 10 13 16 20 25 32 40 16 21 26 33 41 52 66
12-24 LED, 45-96W 38 A (280 µs) 6 8 10 13 16 20 26 10 13 16 21 26 33 42
24-32 LED, 70-144W 56 A (277 µs) 3 4 5 6 7 9 12 5 6 8 10 12 16 20
32-52 LED, 100-211W 85 A (215 µs) 3 4 5 6 7 9 12 5 6 8 10 12 16 20
52-64 LED, 135-288W 112 A (277 µs) 1 2 2 3 3 4 6 2 3 4 5 6 8 10
64-96 LED, 200-380W 170 A (215 µs) 1 2 2 3 3 4 6 2 3 4 5 6 8 10

Energy efficiency class of contained light source(s)

Energy efficiency

Standard

CRI
70 80 90
CCT 1800 F    
2200 E    
2500 E    
2700 D E F
3000 D E F
4000 C D E
5000 C D E
5700 C D E
6500 C   E

Eco

  CRI
70 80 90
CCT 2200 E F  
2700 E E F
3000 E E F
4000 D E F
5000 D E F
5700 D E F
6500 D E  

Terms of use and maintenance

Before luminaire is turned on, it should be mounted according with this mounting instruction or any other applicable regulations.

Mounting instructions

Mounting of luminaire must be performed by a qualied person according with following instructions:

  • The warranty of luminaire does not apply, if the mounting of luminaire has been performed in precipitation (rain, snow, hail).
  • The warranty of luminaire does not apply, if a control system unauthorized by VIZULO or an inapplicable LED driver has been used to drive the luminaire.
  • The warranty of luminaire does not apply, if it has been used in an unsuitable ambient temperature or has been supplied by voltage outside of the specied range.
  • The warranty of luminaire does not apply, if the LED driver program has been changed in any way.
  • The warranty of the luminaire does not apply, if the logged history data of the LED driver has been deleted without the permission of VIZULO.
  • The warranty of luminaire does not apply, if it has been mounted in unspecied angles or upside down (luminaire glass directed up), or it has been completely submerged under water.

Safety instructions

Any actions with the luminaire must be performed by a qualified person, who is certified according with national regulations and requirements.
To prevent any accidents person installing the luminaire must follow national safety requirements and following instructions:

  • The label containing technical parameters of the luminaire has to be studied before the work on it has begun.
  • Any luminaire build or design changes are prohibited.
  • The luminaire must be used in good technical condition and according with this instruction.
  • Only VIZULO authorized spare parts and accessories can be used to repair the luminaire.
  • The repair of luminaire has to be performed by a qualified and certified person.

Maintenance and repair

Luminaire has to be disconnected from electrical grid before it is opened and/or repaired!

  • The person working with the luminaire must follow national regulations and legislations that apply to maintenance and testing of electrical or electronic appliances.
  • The luminaire may need to be cleaned depending on its environment. Only a damp cloth or a sponge may be used to clean the luminaire. Use only household detergents diluted by water.
  • Only VIZULO authorized spare parts may be used for the luminaire.
  • Instruction for changing spare parts must be requested from VIZULO and studied before the repair is attempted.
  • LED modules, lens and LED drivers can be changed on an installed luminaire, but it is advised to perform this task indoor to avoid water entering the luminaire.
  • Spare parts (lens, LED modules and drivers) should be ordered from the information available on the luminaire label.

Logo

Documents / Resources

VIZULO Crocus LED Luminaire [pdf] Instruction Manual
Crocus LED Luminaire, Crocus LED, Luminaire

References

Leave a comment

Your email address will not be published. Required fields are marked *