FEATURES

Power supply 120-240 V~ ± 10% 50/60 Hz
Output relay with clean change-over contact 4 A 250 V~ cos φ 1 N.O. (NO SELV)
Typical absorption 25 mA – 120 V~
40 mA – 240 V~
Operating temperature -5 °C – +35 °C
indoor use

CONTROLLABLE LOADS AT 120-240 V~

Cycles

Resistive loads 4 A
Motors cos φ 0.6 2 A

INSTALLATION RULES

The relay output power supply circuit must be protected against overcurrent’s by installing a device, a fuse with a rated breaking capacity of 1500 A or a type-C circuit breaker, with rated current not exceeding 10 A.

REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead

DEVICE DETAILS, CONFIGURATION AND WEEE INFORMATION CAN BE DOWNLOADED IN PDF FORMAT FROM THE PRODUCT DATA SHEET ON www.vimar.com (the QR code opens the data sheet of art. 30403.B, which shares the same instructions sheet as art. 30403.x).

VIMAR 30403 G LINEA Smart Switch - QR Code 1https://www.vimar.com/en/int/catalog/product/index/code/30403.B