Vexen LogoPF-360-09-1CWi Presence Detector
Instruction ManualVexen PF 360 09 1CWi Presence DetectorPF-360-09-1CWiVexen PF 360 09 1CWi Presence Detector - Symbol

PF-360-09-1CWi Presence Detector

PART OF THE LENS SHIELD IS USED.

Vexen PF 360 09 1CWi Presence Detector - SHIELDVexen PF 360 09 1CWi Presence Detector - included *Optional – not included!Vexen PF 360 09 1CWi Presence Detector - Product codeMore sensitive of movement walking across the detector
Less sensitive of movement directly towards to detectorVexen PF 360 09 1CWi Presence Detector - detectorMore information on our web page:

Safety instructions

Electric Warning Icon WARNING
Life-threatening danger from electric shock!
Should only be installed by a professional electrician!

  • To avoid injury, the device should only be connected and installed by a professional electrician.
  • Before installing the product, turn off the main power supply.
  • Before installing the device, install a circuit breaker (250 V AC, 10 A) type C as specified by EN 60898-1.
  • When some types of lamps burn out, it can cause the switch-on current to be high which can permanently damage the detector.
  • Follow national regulations and safety instructions.
  • All warranties and conditions expire if the device is altered or manipulated in any way

Follow these instructions to ensure proper and safe functioning of this device.

Information about the device

Description
The presence detector uses passive infrared sensors (PIR sensors). It regulates the connected loads according to whether persons are present (movement detection) and according to the ambient brightness.
The built-in light sensor continuously measures the strength of daylight and the system compares this against the set lux value.

  • The light remains switched on for as long as movement and insufficient daylight are detected.
  • After the last movement is detected, the lighting remains switched on for the set run-on time.
  • The lighting switches off automatically as soon as sufficient ambient brightness is reached, even if movement is detected during this time.

Intended use

  • Suitable for automatic lighting control with presence detection.
  • The presence detector can be used inside buildings such as offices, class- rooms, working areas or meeting rooms, hotel rooms or sport halls.
  • Suitable for ceiling insulation (flush-mounted installation).

Technical data

Dimensions (mm) Ø 75 x 78
Supply voltage Switching capacity 210-250V 50/60HZ
– Incandescent lamp load max. 2000 W
– Halogen lamp load (AC) max. 1000 W
– Halogen lamp load (LV) max. 1000 VA / 600 W (conventional)
max. 1000 VA / 900 W (electronic)
– Fluorescent lamp load max. 900 VA/100 μF
25 x (1 x 18 W); 12 x (2 x 18 W); 15 x (1 x 36 W); 7 x (2 x 36 W); 10 x (1 x 58 W); 5 x (2 x 58 W); max. 1000VA/600W
– LED lamp max. 400 W
– Energy-saving lamp max. 600 VA / 400 W (incl. CFL and PL lamp)
Energy consumption < 1 W (in standby mode)
Detection angle 360°
Detection range approx. 9 m at an installation height of 2.5 m
Time setting approx. 5 sec. to 30 min.;Vexen PF 360 09 1CWi Presence Detector - Symbol 2Test
Light level 000 approx. 10 –  Vexen PF 360 09 1CWi Presence Detector - Symbol 3(Vexen PF 360 09 1CWi Presence Detector - Symbol 4) Lux;  Vexen PF 360 09 1CWi Presence Detector - Symbol 5 = “teach”30m
Ambient temperature II
Protection class IP44

Installation and assembly

Dimensions (FIG. 1)
Location/installation (FIG. 2)

  • Do not install the presence detector close
    – to sources of heat, fan heaters, air conditioning or other devices that can interfere with the sensor).
    – Objects with shiny surfaces (such as mirrors)
    – Objects that can be moved by the wind (such as curtains, large plants)
  • Keep out of direct sunlight.
  • The recommended installation height is 2.5 m.
  • The distance between the sensor and the seated person should be about 1 m.
    This ensures the greatest detection reliability.

Connection layout (FIG. 3)
Warning icon Life-threatening danger from electric shock!
Should only be installed by a professional electrician!
FIG.3A A lighting device is controlled by a presence detector.
FIG. 3B The lighting device is turned on for an adjustable time either by the presence detector or the stair timed light switch.
The “TIME” knob needs to be set at Vexen PF 360 09 1CWi Presence Detector - Symbol 2.
(a) button (N.O. type),
(b) = lighting device (light),
(c) = stair timed light switch

  • It may be necessary to use a fuse in the case of noise filters (such as relays, contactors, quenching circuit).
  • A maximum of six units can be parallel-connected.

Installation (FIG. 4)
NOTE: Disconnect the power and secure against being accidentally turned on!
For the procedure, see fig . 4.
On-wall mounting (FIG. 5)
The presence detector can be mounted on the wall using the VSMB10 on-wall box.

Adjusting and Setting

Adjusting knobs (FIG. 5)
Detection range METER (Vexen PF 360 09 1CWi Presence Detector - Symbol 6)
Use the “METER” knob to adjust the range of the presence detector.
Light level LUX (Vexen PF 360 09 1CWi Presence Detector - Symbol 7)
Use the “LUX” knob to set the level of ambient light.
On TIME (Vexen PF 360 09 1CWi Presence Detector - Symbol 8)
Use the “TIME” knob to set the length of time after which the lighting device turns off after motion is detected.

Save light level (Vexen PF 360 09 1CWi Presence Detector - Symbol 5 mode)
In order to save a desired light level (10 – 2000 Lux), proceed as follows:

  1. Set the “LUX” knob to the “Vexen PF 360 09 1CWi Presence Detector - Symbol 5” position when the ambient brightness corresponds to the desired level of light.
  2. If the knob is already at the “Vexen PF 360 09 1CWi Presence Detector - Symbol 5” position, turn it to another position (such as “100”) for approx. 3 seconds, and then turn it back to the “ Vexen PF 360 09 1CWi Presence Detector - Symbol 5” position.
    ▷ This turns off the connected lighting device.
    ▷ The LED on the presence detector starts to flash slowly (training mode active).
  3. It takes about 25 seconds to save the light level.
    ▷ If training has been successful, the lighting device and the LED turn on for 5 seconds, or the LED flashes for 5 seconds and the lighting device is OFF.
    ▷ The presence detector switches back to automatic mode (the LED and lighting device are turned off).

Operating manual

IRSP-11 – service remote control*
General

  • IRSP-11 is a service remote control for commissioning and flexible adjustment of individual parameters. It is suitable for the following presence detectors:
    – SENSA PRO
  • Interventions in and modifications to the device shall result in loss of warranty and guarantee.
  • Read and observe this manual in order to ensure trouble-free functioning of the device and safe work.

Commissioning
Before using the product, remove the protective foil between the battery and the contact (Fig. 7).

Button functions

Vexen PF 360 09 1CWi Presence Detector - Symbol 9 Switching on the lighting device for 8 hours (CH1)
Vexen PF 360 09 1CWi Presence Detector - Symbol 10 Switching off the lighting device for 8 hours (CH1)
Vexen PF 360 09 1CWi Presence Detector - Symbol 11 Locking the buttons
Vexen PF 360 09 1CWi Presence Detector - Symbol 12 Unlocking the buttons
Vexen PF 360 09 1CWi Presence Detector - Symbol 13 Switching between automatic mode/semi-automatic mode
Vexen PF 360 09 1CWi Presence Detector - Symbol 14 Reset (resets presence detector to potentiometers’ settings)
Vexen PF 360 09 1CWi Presence Detector - Symbol 15 Saving and duplicating settings
Vexen PF 360 09 1CWi Presence Detector - Symbol 20. Setting the light sensor value (LUX) (10 – 2000 Lux)
Vexen PF 360 09 1CWi Presence Detector - Symbol 19 Saving the current light sensor value
Vexen PF 360 09 1CWi Presence Detector - Symbol 16 Setting the set on period (TIME1)Vexen PF 360 09 1CWi Presence Detector - Symbol 16Setting the set on period (TIME2)
Vexen PF 360 09 1CWi Presence Detector - Symbol 17 Pulse mode CH1/CH2
Vexen PF 360 09 1CWi Presence Detector - Symbol 18 Test mode

Menu sequence

  1. Unlock the IR receiver.
    The LED on the IR receiver flashes twice.
  2. Select the channel.
  3. Make the desired settings.
  4. Lock the IR receiver.
    The LED on the IR receiver lights up for two seconds.

If no button is pressed for 5 min., the menu sequence is terminated and the IR receiver is locked again.

Technical data

Battery 3 VDC lithium CR2032
Transmission range 10 m (Fig. 8)
Transmission angle 35° (Fig. 8)
Ambient temperature 0°C … +45°C

Vexen PF 360 09 1CWi Presence Detector - eated

Height Walka cross Walka owards Seated
Vexen PF 360 09 1CWi Presence Detector - Height Vexen PF 360 09 1CWi Presence Detector - Walkacross Vexen PF 360 09 1CWi Presence Detector - Walk across 1 Vexen PF 360 09 1CWi Presence Detector - Walkacross 1
2.0m ∅ 8m ∅ 4m ∅ 3m
2.5m ∅ 9m ∅ 4m ∅ 3m
3.0m ∅ 9m ∅ 4m ∅ 3m

Measured according to EN/IEC63180Vexen PF 360 09 1CWi Presence Detector - accordingVexen PF 360 09 1CWi Presence Detector - according 1Vexen PF 360 09 1CWi Presence Detector - according 2

Vexen LogoSIA PAWBOL Baltic
Reg. Nr: 40103888768
VAT: Nr LV40103888768
Katlakalna 9, Riga, Latvia, LV1073
Phone: + 371 62006800
Email: info@vexen.eu

Documents / Resources

Vexen PF-360-09-1CWi Presence Detector [pdf] Instruction Manual
PF-360-09-1CWi Presence Detector, PF-360-09-1CWi, Presence Detector, Detector

References

Leave a comment

Your email address will not be published. Required fields are marked *