VEVOR SPP200E Fixed Speed Pool Pump Instruction Manual
VEVOR SPP200E Fixed Speed Pool Pump Instruction Manual

FIXED SPEED POOL PUMP

This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won’t inform you again if there are any technology or software updates on our product.

Read iconWarning-To reduce the risk of injury, user must read instructions manual carefully.

disposal icon This product is subject to the provision of European Directive 2012/19/EC. The symbol showing a wheelie bin crossed through indicates that the product requires separate refuse collection in the European Union. This applies to the product and all accessories marked with this symbol. Products marked as such may not be discarded with normal domestic waste, but must be taken to a collection point for recycling electrical and electronic devices

MATTERS NEED ATTENTION

  1. The installation must be according to the normal power indicated on the label.
  2. The amperage must not at any time exceed the value indicated on the label.
  3. It is recommended that you consult a state-registered electrician.
  4. Place the pump in a dry area with good ventilation.
  5. The ambient temperature must not exceed 40°C.
  6. The pumps are only suitable for counter-clockwise rotation when viewing from the pump end. Three phase motors can rotate in either direction.Interchanging any of the cables on a three-phase motor will reverse the rotation. Momentarily start, or bump the motor without water in the tank,to check the rotation of the pump shaft.
  7. Before disconnecting electrical connections, shut off electricity at its source. Never work on pump without making certain the power is OFF.
  8. This appliance is not intended for use by persons, including children with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a responsible for their safety.
  9. Children should be supervised to ensure that they do not play with the appliance.

APPEARANCE AND NAME OF PARTS
product overview

NO. Name NO. Name
1 Pump body 14 Before cover
2 Transparent cover 15 Back cover
3 O size circle 16 Fan blade
4 Filter basket 17 Fan cover
5 Basement 18 Capacitor
6 O size circle 19 Terminal box
7 Diffuser drive pipe 20 Thread cap
8 Big diffuser 21 Bearing
9 Impeller 22 Cover of terminal box
10 Shaft 23 Bracket cover
11 Circle 24 Motor shell
12 Stator module 25 Mechanical Seal
13 Rotator module 26 O Size circle

SPECIFICATION PARAMETER

Model SPP200E
Input (Voltage/Frequency) AC220-240V 50Hz
Max power 1100W (1.5 HP) or 1300W (1.75 HP)
Max Flow Rate (Q max) 28800 L/H (or 33,600 L/H depending on specific model variation)
Max Head (H max) 17m (approx. 55 ft)
Max Suction 2.5m-4m
Operating temperature 0-50°C (Liquid)
Hose joint 50mm (2″)
Inlet/outlet caliber G 2 1/4 (External thread)

CHECKING POINTS BEFORE INSTALLATION

  • Install the pump just over the well as possible as you can.
  • But when the pump must be installed away from the well because of thecircumstances, the maximum distance of the pipe from the well to the pump is limited according to the suction lift.

GUIDE FOR INSTALLATION

  • Electrical supply:Single-phase 220 – 240VAC, 50Hz. Three-phase 380 – 400VAC, 50Hz.
  • The pump must be installed in a place where there is easy access to the terminal box.
  • The pump has to be mounted on a fixed and firm base by means of bolts.
  • Class1 appliances must be permanently connected to fixed wiring.
  • If the supply cord is damaged,it must be replaced by the manufacturer or its service agent or similarly qualified person in order to avoid a hazard.

Connection diagram for three phase motors
daymention

HOW TO OPERATE THE PUMP
Locate the pump as close as possible to the pool.Provide the necessary space around and below the pump for further inspection and servicing of the unit.
The pump suction line should not be smaller than the pressure line.All
piping must be airtight The threads on the pump must be sealed with Teflon Tape or Silicone,when the pump unions are screwed on.Tighten the pump unions only as much as is required to ensure a tight connection.Excessive torque is un-necessary and may cause damage to the pump.
The weight of the piping should be supported independently and not carried by the pump.The pump motor must be wired for the proper voltage and rotation,in accordance with the wiring diagram.Voltage,phases,ampere draw,and cycles are given on the pump nameplate.
Fill the pump tank with water before starting.This may be done through the tank lid.The LIQUIDUS pumps prime themselves providing the pump tank is filled with water.Should you lose this liquid from the tank accidentally or by draining purposely,it will be necessary to refill it before starting.
High suction lifts,or long suction lines,require additional time and reduce the performance of the pump.Should you have difficulty,refer to the” Troubleshooting Guide”.
The water being pumped cools and lubricates the seal.Running the pump dry will damage the seal.Always keep liquid in the pump tank.No further lubrication of the pump end is necessary.
After the pump tank has been filled with water,and the motor started,allow a few moments for the pump to start delivering water.Be sure that all suctions and discharge valves are open when pump is running.Operating the pump with a closed valve in the system can cause pump damage.If flow does not start within ten minutes,stop the motor and determine cause(See “Troubleshooting Guide”). 

CARE AND MAINTENANCE
The strainer basket built into the pump tank should be inspected and cleaned at regular intervals.These strainer baskets are easy to clean.Remove the tank lid to expose the strainer basket.Remove the basket and clean.Inspect the lid o-ring,if damaged,replace.Replace the strainer basket and re-install the lid.Tightening by hand only.
If your pool is deactivated until next season,care must be taken to protect the pump part from damage.Drain completely by removing the drain plug provided at bottom of pump tank.Do not replace the plug,but store it in the strainer basket for the winter.An alternative is to remove the pump and store it indoors in a warm dry location.
If the pump is used with seawater it is necessary to flush it with clean water.We also recommend that the seals are changed before next season.
It is also possible to leave the pump wet end and piping intact and only remove and store the motor and impeller assembly.In this case remove the motor to tank screws.Protect the remaining pump parts that are attached to the system,from a build-up of liquid from rain and snow.
When activating the pump again,reverse the above procedure.Replace the body O-ring between the tank and the back plate if damaged.Install drain plug.Check the pump shaft for free movement.Prime the pump as above and check the rotation of pump shaft.

TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE
SYMPTOMS PROBABLE CAUSES RECOMMENDED ACTION
1.Pump will not prime 1a.Suction air leak e sure water in pool is high enough to flow through skimmer Make sure lid o-ring is clean and properly positioned Hand tighten tank lid down snugly Tighten all pipes and unions on suction of pump Remove and replace pump seal
1b.No water in pump Make sure pump tank is full of water
1c.Closed valves or blocked lines Open all valves in system Clean skimmer and pump strainer basket Open Pump and check for clogging
2.Motor does not turn 2a.No power to motor Check that all power switches are on Be sure fuse or circuit breaker is properly set Timer properly set? Check timer for
proper operation Check motor wiring at terminals
2b.Pump jammed With power off turn shaft-it should spin freely .If not electrician should disassemble and repair
3.Low flow 3a.Dirty filterv Back wash filter when filter pressure is “high”
3b.Dirty skimmer basket Clean skimmer and pump strainer baskets
3c.Suction air leak (See problem 1)
3d.Closed valves or blocked lines (See problem 1)
4.Motor runs hot These motors will run “hot” to the touch. However this is normal, they are designed that way.Thermal overload protector will function to turn them off if there is an overload or high Wiring to be corrected by licensed electrician
temperature problem. Excessive heat can be caused by: 4a.Low or incorrect voltage
4b.Installed in direct sun. Shield motor from sunrays
4c.Poor ventilation Do not cover or enclose motor
5.Noisy operation of motor 5a.Bad bearings Ask an electrician to replace bearings in motor
6.Noisy operation of pump 6a.Air leak in suction line.Bubbles in water returning to pool at inlet Repair leak Check suction pipe Is lid o-ring clean?
6b.Restricted suction line due to blockage or undersized pipe.Indicated by high vacuum reading at pump suction Have serviceman remove blockage or increase suction pipe size. Make sure strainer basket is clean Are all suction valves fully open?
6c.Foreign matter(gravel,metal etc)in pump impeller Ask electrician to disassemble pump and remove foreign matter from impeller
6d.Cavitation Improve suction conditions(reduce suction lift,reduce number of fittings,increase pipe size) Increase discharge pressure and reduce flow by throttling discharge valve
7.Motor overload protection “kick out” 7a.Motor is improperly connected Ask electrician to check wiring diagram on motor
7b.Low voltage due to undersized wire or low incoming voltage Ask electrician to check with volt meter Increase size of supply wire Report low supply voltage to power company Voltage of motor must be within 6% of motor nameplate voltage
8.Pump is leaking 8a.Seals are worn out The seal is a wear part that must be changed occasionally.The seal must especially be changed more often if the pump is used with sea water,and not flushed with clean water when drained

Manufacturer: Shanghaimuxinmuyeyouxiangongsi
Address: Shuangchenglu 803nong11hao1602A-1609shi, baoshanqu,
shanghai 200000 CN.

Manufacturer: Shanghaimuxinmuyeyouxiangongsi
Address: Shuangchenglu 803nong11hao1602A-1609shi, baoshanqu,
shanghai 200000 CN.
UK REP

Documents / Resources

VEVOR SPP200E Fixed Speed Pool Pump [pdf] Instruction Manual
SPP200E, SPP200E Fixed Speed Pool Pump, Fixed Speed Pool Pump, Speed Pool Pump, Pool Pump, Pump

References

Leave a comment

Your email address will not be published. Required fields are marked *