VEVOR-logo

VEVOR JCS-C Industrial Counting Scale

VEVOR-JCS-C-Industrial-Counting-Scale-product

Product Information

Specifications:

  • Model: JCS-C
  • Weighing Units: Kg, grams, lb, ounces, carat
  • Intended Use: Weighing, counting, and formula scale for factories and laboratories
  • Non-trade use only

Technical Support and E-Warranty Certificate
www.vevor.com/support

We continue to be committed to provide you tools with competitive price. “Save Half”, “Half Price” or any other similar expressions used by us only represents an estimate of savings you might benefit from buying certain tools with us compared to the major top brands and does not necessarily mean to cover all categories of tools offered by us. You are kindly reminded to verify carefully when you are placing an order with us if you are actually saving half in comparison with the top major brands.

(The picture is for reference only, please refer to the actual object)

NEED HELP? CONTACT US!

Have product questions? Need technical support? Please feel free to contact us:
Technical Support and E-Warranty Certificate
www.vevor.com/support

This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won’t inform you again if there are any technology or software updates on our product.

Power On Display

  1. The JCS-C precision scale boasts exceptional industrial quality and innovative design concepts for SMT production counting. It offers outstanding performance and can meet a variety of work requirements in different environments. This product serves as a weighing, counting, and formula scale for use in factories and laboratories. It is intended for non-trade use.
  2. Multiple weighing units: Kg, grams, lb, ounces, carat and other custom weighing units are available.
  3. Enhanced micro-weighing for precise sample additions: Utilizing the latest digital processing technology, it maintains stability in reading while significantly improving response speed for micro additions. This ensures consistency between the sample added and the scale’s reading.
  4. Automatic zero stability setting: Environmental changes can cause zero drift in the display. The automatic zero stability setting ensures that the scale maintains weighing from the minimum weighing value even with minor environmental fluctuations.VEVOR-JCS-C-Industrial-Counting-Scale-fig-1

Common Functions

  1. Keypads (4 in total):
    【CAL】、【PCS】、【UNIT】、【ZERO/TARE】
  2. Simple functions:
    1. Zero-setting range: ±2%.
    2. Tare range: 2%~100%. When using【ZERO/TARE】, it functions as zero-setting within the zero-setting range, otherwise, it tares.
    3. Default function: Simple weighing, but can also be switched to the desired function or setting as needed.
    4. Overload: When exceeding 100%FS + 9d, it displays【-DE-】。
    5. Counting: When exceeding 999999, it displays【——————】。
    6. Low voltage:
      Below 3.55V, it continuously displays the voltage value.
      Above 3.55V but below 3.65V, it intermittently indicates low voltage.
    7. When displaying internal codes after startup, it prompts for recalibration or servicing.
  3. Indicator lights
    Zero, Tare, PCS, Kg, g, lb, oz, ct, AC.VEVOR-JCS-C-Industrial-Counting-Scale-fig-2
  4. Unit conversion
    Press the【UNIT】key to switch between Kg/g/Lb/oz/ct units; the unit change is not saved.
  5. Counting FunctionVEVOR-JCS-C-Industrial-Counting-Scale-fig-3
    1. If sampling has been done previously, pressing the【UNIT】key allows direct switching to counting mode.
      A. To resample if necessary, long-press the【PCS】key to reselect the sampling quantity.
      B. While counting, pressing the【UNIT】key allows exit.
    2. If no previous sampling has been done, press the【UNIT】 key until the PCS indicator light is on to enter the sampling quantity selection mode:VEVOR-JCS-C-Industrial-Counting-Scale-fig-4A. Press the【CAL】key to choose a quantity value of 10/20/50/100/200/500, place the object, press the【PCS】key to confirm, and proceed to the next step.
      B. During the selection of the sampling quantity, you can press the【UNIT】key to exit.
      Note: If the weight is zero or negative, it will display【-Erro-】and return to the sampling quantity selection.
      If the single weight is less than 50% of the scale division value, it will display 【-SLAC-】before entering counting mode.
      If the sampled weight is less than 40 scale division values, it will display 【-CSL-】before entering counting mode.

User Calibration

  1. Access user calibration:
    In weighing mode, long-press the【CAL】key for 2 seconds to access user calibration, displaying:VEVOR-JCS-C-Industrial-Counting-Scale-fig-5
  2. Obtain the calibration zero point:
    displaying:VEVOR-JCS-C-Industrial-Counting-Scale-fig-6After obtaining the zero point, press any key proceed to the next step.
  3. Choose the calibration weight value, with a blinking display of the calibration weightVEVOR-JCS-C-Industrial-Counting-Scale-fig-7
    1. A. If no change in calibration weight value is needed,press any key once, displaying the weight of weight,place the calibration weight, press the
      【ZERO/TARE】key to complete the calibration.
    2. B. If a change in calibration weight value is needed:
      1. Press the【PCS】key to move the digits (starting from the highest digit), with the currently modified digit blinking.
      2. Press the【ZERO/TARE】key to change the current digit value (cycling from 0 to 9).
      3. Press the【UNIT】key to confirm the calibration weight value and display the entire calibration weight value blinking.
      4. After confirming the calibration weight value, place the calibration weight and press the【ZERO/TARE】key to complete the calibration.

Settings Mode

Press the【ZERO/TARE】 key when powering on to enter the settings mode, displaying XXXXXX (default 102063).

  • Use the【PCS】key to move the digits (starting from the highest digit), with the currently modified digit blinking.
  • Use the【ZERO/TARE】key to change the current digit value (cycling from 0 to 9).
  • Press the【UNIT】key to confirm and return to weighing.VEVOR-JCS-C-Industrial-Counting-Scale-fig-8
  1. Option C represents brightness settings (range: 1~3), default is 2: LED: 1 – Lowest, 2 – Medium, 3 – Highest.
  2. Option D represents zero tracking range (range: 0~9), default is 1:
    1. a) Zero tracking range = (D value) × 0.5d.
    2. b) For example, 0 represents auto, 1 represents 0.5d, 2 represents 1d, and so on.
  3. Option E represents linear compensation range, default is 0:
    a) 1~9 represents 1~9d.
  4. Option F represents the power-on default unit (range 1~3), default value is consistent with the model setting:
    1. a) 1 represents default unit: kg.
    2. b) 2 represents default unit: Lb.
    3. c) 3 represents default unit: g.
    4. d) 4 represents default unit: oz.
    5. e) 5 represents default unit: ct.
      Note:
      If the weight decimal point is >= 3 digits and the unit is set to g in the model setting, changing to kg/Lb is ineffective (default switches to more than 5 decimal places).
      After changing the model, the default unit becomes consistent with the model unit setting. For example, if the model was set to kg, and the power-on default unit was set to Lb, but the unit was changed to g during the model change, the power-on default unit becomes g.

Model Setting Mode

  • Press the【CAL】+【UNIT】keys when powering on to enter the model setting mode, displaying (default 03000.1).VEVOR-JCS-C-Industrial-Counting-Scale-fig-9
  • This represents the model as follows: Maximum weighing value of 3000.0, 1 decimal place, division value of 1, unit in g.
  • Use the【PCS】key to move digits (from the 6th digit to the 2nd digit), selecting the decimal point, division value (rightmost digit), and unit.
  • Use the【ZERO/TARE】key to change digits, decimal places, division value, and unit.
  • Use the【UNIT】key to confirm changes and return to weighing.
  1. Change the maximum weighing value:
    Use the【PCS】key to move digits (from the 6th digit to the 2nd digit) and use the【ZERO/TARE】key to update digits.
  2. Change the division value:
    Use the【PCS】key to move to the 1st digit (rightmost digit) and use the
    【ZERO/TARE】key to switch division values (1/2/5).
  3. Change the decimal places:
    Use the【PCS】key to move to the blinking decimal point and use the
    【ZERO/TARE】key to switch between 0~5 decimal places.
  4. Change the unit for the model:
    Use the【PCS】key to move to the unit symbol blinking, and use the
    【ZERO/TARE】key to switch between Kg/g.

Metrological Performance

Specifications Calibration Division Value (e) Display Division Value (d=e) Maximum Weighing (Max) Minimum Weighing (Min 20e) Zero-setting Range (±2% Max) Tare Range (+100%

Max)

Display Limit (Max+9E)
10kg 0.1g 0.1g 10kg 2g ±200g +10kg 10000.9

Choice of power source:

  1. North America plug:AC110V 60Hz
  2. European plug:AC220-240V 50Hz
  3. Australian plug:AC220-240V 50Hz

Environmental Requirements:

  • Humidity: Relative humidity not exceeding 90%
  • Temperature: Storage temperature -10°C to +50°C
  • Operating temperature 0°C to +40°C
  • Humidity: Storage humidity <70%RH (no frost)
  • Operating humidity <90%RH (no condensation)

Common trouble shooting

No TROUBLE MEANS REASON ADVISE
 

1

Turn

on ,show“LB”and alarm

LOW   BATTERY(POWE

R)

Battery no power RECHARGING
Battery broken change the battery
 

 

 

2

 

 

 

Turn

on ,show“ED”

 

 

 

WEIGHING ERROR

LOAD CELL LINE

SEALING -OFF

RE-SEALING
LOAD CELL TOUCH

WITH SOMETHING

CHECKING
LOAD CELL BROKEN CHANGE THE LOAD

CELL

PCB BROKEN CHANGE THE PCB
 

 

 

 

 

 

3

 

 

 

 

 

 

Turn on ,hop counting

 

 

 

 

 

The weight window number on changing,cannot weighing

too WET DRY the PCB and load

cell

 

TOO DURTY

take down the PCB, using Alcohol cleaning

first ,then dry it

LOAD CELL TOUCH

WITH SOMETHING

CHECKING
LOAD CELL LINE

SEALING -OFF

RE-SEALING
LOAD CELL BROKEN CHANGE THE LOAD

CELL

PCB BROKEN CHANGE THE PCB
 

 

4

 

When charging ,counting

The weight window number on changing,cannot

charging

 

 

Adaptor

 

 

change the adaptor

 

 

5

 

 

Digital 8 not full show

 

 

Digital 8 not full show ,or less

electronic circuit short using rubber-insulated

wire link together

LED Broken change the LED
Drive broken change the display

board

 

 

 

 

6

 

 

 

key can not working

 

 

 

press the key can not working

the key be stucked checking
the key can not spring

back

changing the key
key electronic circuit

short

using rubber-insulated

wire link together

PCB BROKEN CHANGE THE PCB
KEY BOARD

CORRODE

CHANGE THE KEY

BOARD

 

 

 

7

 

 

 

NO WEIGHT

 

 

 

no any weight

the load cell line and

PCB link broken

checking
LOAD CELL LINE

SEALING -OFF

RE-SEALING
LOAD CELL BROKEN CHANGE THE LOAD

CELL

PCB BROKEN CHANGE THE PCB
 

 

 

 

 

8

 

 

 

 

 

can not turn on

 

 

 

press the on/off button ,can not turn on

the ON/OFF BUTTON

BROKEN

CHANGE THE ON/OFF

BUTTON

CHECK THE BATTERY POWER IS

ENOUGH

LOW

VOLT ,RECHARGE

  BATTERY BROKEN CHANGE IT ,V<5.6V
PCB BROKEN CHANGE THE PCB
 

 

 

9

 

 

when turn on DI DI DI sound all the time

 

 

when turn on DI DI DI sound all the time

CHECK THE BATTERY POWER IS

ENOUGH

LOW

VOLT ,RECHARGE

  BATTERY BROKEN

CHANGE IT ,V<5.6V

PCB BROKEN CHANGE THE PCB
 

 

10

turn on the sound normal,but no words turn on the sound normal,but no words check the displaybord

to PCB link is ok

turn off , relink the

display board link

display board broken change the display

board

 

 

 

11

 

 

turn on show“8”all the time

when turn on the scale,all the window show 8,can not weighing,and the

sound it is normal

check the displaybord

to PCB link is ok

turn off , relink the

display board link

 

 

display board broken

 

change the display board

 

 

 

 

 

 

12

 

 

 

 

 

 

can not recharge

When charging AC light is working,but

can not charge

Adaptor change the adaptor
Battery broken change the battery
 

 

 

When charging AC light is not working,

adaptor change the adaptor
adaptor plug take down recharging
charging connect

broken

change the connect part
the charging connect

to the PCB link off

re sealing
PCB BROKEN CHANGE THE PCB
Battery broken change the battery
  Items Description
1 Sales territory North America
2 Name Counting Scale
3 Model JCS-C
4 Parameter Rating(s): AC110V/60Hz,Capacity: 10kg,Division: 0.1g

 

  Items Description
1 Sales territory Europe
2 Name Counting Scale
3 Model JCS-C
4 Parameter Rating(s): AC220-240V/50Hz,Capacity: 10kg,Division: 0.1g
  Items Description
1 Sales territory Australia
2 Name Counting Scale
3 Model JCS-C
4 Parameter Rating(s): AC220-240V/50Hz,Capacity: 10kg,Division: 0.1g

Manufacturer: Shanghaimuxinmuyeyouxiangongsi
Address: Shuangchenglu 803nong11hao1602A-1609shi, baoshanqu, shanghai 200000 CN.
Imported to AUS: SIHAO PTY LTD. 1 ROKEVA STREETEASTWOOD NSW 2122 Australia
Imported to USA: Sanven Technology Ltd. Suite 250, 9166 Anaheim Place, Rancho Cucamonga, CA 91730

VEVOR-JCS-C-Industrial-Counting-Scale-fig-10 E-CrossStu GmbHv Mainzer Landstr.69, 60329 Frankfurt am Main.

VEVOR-JCS-C-Industrial-Counting-Scale-fig-11 YH CONSULTING LIMITED. C/O YH Consulting Limited Office 147, Centurion House, London Road, Staines-upon-Thames, Surrey, TW18 4AX

Technical Support and E-Warranty Certificate
www.vevor.com/support

FAQ

  • Q: What should I do if the scale displays low voltage?
    A: When the scale displays low voltage (below 3.55V), consider replacing the batteries or recharging them to ensure proper functionality.
  • Q: How can I switch between different weighing units?
    A: Press the UNIT key to cycle through different units such as Kg, grams, lb, ounces, and carat on the display.

Documents / Resources

VEVOR JCS-C Industrial Counting Scale [pdf] User Manual
JCS-C Industrial Counting Scale, JCS-C, Industrial Counting Scale, Counting Scale, Scale

References

Leave a comment

Your email address will not be published. Required fields are marked *