VEVOR HS110 Mini Split Pad
Overview
The HS110 mini split stand is a metal support frame designed to hold a mini split unit with a specified maximum load. Assembly requires multiple poles, bases, and hardware components as listed in the package and instructions.
Specifications
| Product name | Mini Split Stand |
| Model | HS110 |
| Product size (mm) | 710~1200 × 550 × 360 |
| Max load (kg) | 250 |
Package list (components)
- Side pole: 2
- Horizontal pole: 4
- Base: 4
- Bolt M8*16: 12
- Washer 18*1mm: 24
- Spring washer M8: 12
- Self-locking nut M8: 8
- Cap nut: M8: 4
- Bolt M8*25: 4
- Buffer pad 40*10: 4
- Open end wrench 10-13: 2
- Expansion screw M8*70: 4
- Manual: 1
Quick Setup & Use
- Insert four bases into the side poles, then assemble using 4 sets of M8 washers and M8 self-locking nuts.
- Install two horizontal poles: use an M8 washer, an M8*16 bolt, an M8 cup nut, and an M8 spring washer.
- Install the other two horizontal poles using the same hardware set as in Step 2.
- Install the buffer pads using 4 sets of M8 washers, M8*25 bolts, and M8 self-locking nuts.
This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won’t inform you again if there are any technology or software updates on our product.
IMPORTANT SAFEGUARDS
WARNING
Read and understand this entire manual before
operating or servicing this product. Failure to follow these warnings and instructions can cause personal injury or damage to valuable property. Avoid children using the product. And this product is not a toy. Do not allow children to play.
TECHNICAL PARAMETER

PACKAGE LIST


ASSEMBLY INSTRUCTIONS
Step1:
Insert four bases into the side poles, assemble them with 4 sets of M8 washers, M8 self-locking nuts.

Step 2
Install two horizontal poles with M8 washer, M8*16 bolt, M8 cup nut and M8 spring washer.

Step 3
Install another two horizontal poles with M8 washer, M8 spring washer, M8*16 bolt, M8 cup nut and M8 spring washer.

Step 4
Install the buffer pads, with 4 sets of M8 washers, M8*25 bolts and M8 self-locking nuts.

Troubleshooting
- If parts do not align during assembly, re-check that bases are inserted into the side poles before installing horizontal poles (Steps 1–2).
- If a horizontal pole connection feels loose, confirm the correct sequence of hardware for that pole (M8 washer → M8*16 bolt → M8 cup nut → M8 spring washer as stated in the instructions).
- If buffer pads are not mounting securely, verify you are using the specified hardware for Step 4 (M8 washers, M8*25 bolts, and M8 self-locking nuts).