VEVOR DB-6, DB-8 Wall Vent User Manual
MODEL:DB-6/DB-8
This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won’t inform you again if there are any technology or software updates on our product.
Safety Instructions
Read and understand this entire manual before assembling,installing, operating, or servicing this product.Failure to follow these warnings and instructions can cause personal injury or damage to valuable property.
WARNING: Please carefully read the following instructions in order to reduce the risk of injuries, accidents or damage to the product by itself.
- Products shall be installed by adults;
- Products are installed away from children and pets;
- Please wear gloves to install the product to avoid hand injury;
LIST OF COMPONENTS
PARAMETER LIST
Installation Guide
1.1.Put the cover into the base;
1.2.The screws are fixed with M4×8 screws on both sides and behind the lid, a total of 3 screws.
2. A round hole should be opened at the roof installation position, and the inner diameter of the round hole is 5mm larger than the outer diameter of the ventilation pipe.
3. Place the wall vent in the circular hole, mark four points on the roof according to the screw holes of the mounting plate, drill holes with a diameter of 6mm and a depth of 40mm at the marked points, and finally install M4 expansion screws in the four small holes.
4. If you are connecting the exhaust fan, please refer to the outer diameter of the product ventilation pipe and purchase flexible duct and duct clamp by yourself. First, fix the flexible duct on the ventilation pipe of the wall vent.
5. Then put the wall ventilation port into the middle of the large hole, and align the screw hole of the mounting plate with the expansion screw; fix the product with ST4×35 self-tapping screws, and complete the installation;
6. The ventilation opening in the wall is installed in the same way on other vertical walls.
Note: When the flexible duct is connected with the wall exhaust port and the exhaust fan, if the two ends are not completely sealed, the airflow will produce turbulence, which will cause noise in the wall exhaust port!!!
Manufacturer: Shanghaimuxinmuyeyouxiangongsi
Address: Shuangchenglu 803nong11hao1602A-1609shi, baoshanqu,
shanghai 200000 CN.
Imported to AUS: SIHAO PTY LTD. 1 ROKEVA STREETEASTWOOD
NSW 2122 Australia
Imported to USA: Sanven Technology Ltd. Suite 250, 9166 Anaheim
Place, Rancho Cucamonga, CA 91730
Read More About This Manual & Download PDF:
Documents / Resources
![]() |
VEVOR DB-6, DB-8 Wall Vent [pdf] User Manual DB-6, DB-8, DB-6 DB-8 Wall Vent, DB-6 DB-8, Wall Vent, Vent |