VETEK HL318PLUS SSC LCD Indicator
INTRODUCTION
Technical parameters
6-digit 1.6-inch LCD, various indicating lamps, long service life and good shock resistance
- 7 buttons, simple operation
- Protection level: IP5x
- Excitation voltage: +5VDC
- Load capacity of sensor: at most four 350Ω simulation sensors
- Input signal range at null point: 0~5mV
- Input signal range at full scale: 1~10 mV
- Inner resolution: 1 million
- Display division: 1000~30000
- A/D sampling rate: 120times/sec
- Power supply mode
- Battery: 7.4V/4AH lithium battery
- Adaptor: input voltage 100-240VAC; output voltage 8.4V/1.2A; frequency: 50-60Hz
- RS232
- Working temperature: -10℃-40℃, relative humidity: below 85 %
- Storage temperature: -20℃-60℃, relative humidity: below 85 %
Main Functions
- Basic functions: zero and tare
- Totalization, counting
- Auto power-save
- Parameter redundancy backup
- Real-time clock
- Auto power-off
Dimension
Model
HL318 Plus SSC
Interface
Power supply
RS232
- 1Pin: TXD
- 2Pin: RXD
- 3Pin: GND
Load cell
- 1Pin: +V
- 2Pin: +SN
- 3Pin: +S
- 4Pin:
- 5Pin: -S
- 6Pin: -V
- 7Pin: -SN
Operation
Indicating Lamps
Sign | Meaning | Specification |
![]() |
Dynamic/static | When the scale is dynamic the lamp is on;otherwise, the lamp is off. |
![]() |
Zero-center | When the absolute weight value is less than |
±d/4 the lamp is on; otherwise, the lamp isoff. | ||
Net | Gross/net weight | The lamp is on at net weight and off atgross weight. |
kg | Weight unit | The lamp indicates the weight unit in use. |
Total | Totalization | When the to talizaton function is in use the lamp is on. |
Buttons
Setting
Setting Entry
Normally press 〖CAL〗 until shows. Press〖ON/OFF〗 to enter into the menu setting interface to set parameters from F1~F5. Normally, press 〖GROSS〗 until
shows. Press 〖ON/OFF〗 to enter into the menu setting interface to set parameters from F2~F5. Below shows where the 〖CAL〗 button is.
Detailed Parameter Setting
F1 Scale Parameter Setting
F1.1 Capacity
Selectable parameters:3~200000(default: 6) F1.2 Decimal
Selectable parameters: 0——-no decimal
- 1—— 1 decimal
- 2——–2 decimals
- 3——-3 decimals (default)
- 4——-4 decimals
F1.3 Division
Selectable parameters: 1 (default), 2, 5, 10, 20, 50
Note: when F1.2, F1.3 or F1.4 is being set, division value should not be beyond 10000.
F1.4 Zero Calibration
remove weights off scale and press 『ON/OFF』. The indicator shows
and it decreases to
. Finally,
appears for one second and zero calibration ends.
- F1.5 Load Calibration
add weights Add weights to scale and make sure: full capacity *50% ≤ weights ≤ full capacity. Press『ON/OFF』.
Enter the same value as the weights. Wait until the scale is stable and press 『ON/OFF』. The indicator shows
and it decreases to
Finally,
appears for one second and load calibration ends.
- F1.6 Auto zero-tracking rate
- Selectable parameters: OFF, 0.5d (default)
- At net weight status, zero-tracking is ineffective.
- F1.7 Auto zeroing range at power-on
- Selectable parameters: OFF (default), ±2 %, ±10 %
- F1.8 Zeroing range by button
- Selectable parameters:OFF (default), ±2 %
- F1.9 Digital filter
- Selectable parameters: 0~9, default: 5
- F1.10 Scale function setting
- Selectable parameters: 0——–Totalization (default)
- 1——–Counting
- F 1.11 Restoring factory default
- Selectable parameters: 0——–No restore
- 1——–Restore parameters from F1 to F4 while scale parameters unaffected
F 2 Applicable Parameter Setting
F 2.1 Sampling method
Selectable parameters: 0—-weight on scale sampling (default) 1—–manual input
F 3 Indicator Parameter Setting
F 3.1 Date format setting
Selectable parameters: 0—–year.month.day (default)
- 1—–month.day.year
- 2—–day.month.year
F 3.2 Date setting (see F 3.1)
- F 3.3 Time setting (format: hour.minute.second)
- F 3.4 Overtime backlight shutdown time setting Selectable parameters: 0~999 second (default: 0) If 0 is set, this function is shutdown.
- F 3.6 Auto power-off time setting
- Selectable parameters: 0~60min (default: 0)
- If 0 is set, this function is shutdown.
- F 4 Serial Communication
F 4.1 Method
- Selectable parameters:0—–no output (default)
- 1—–serial output (only when the scale is stable)
- 2——printing output (see Appendix Ⅲ) F4.2 Data and verification setting
- Selectable parameters: 8_N_1 —-8 digits, no verification (default)
- 7_E_1—–7 digits, odd verification
- 7_O_1 —-7 digits, even verification
- 8_E_1 —-8 digits, odd verification
- 8_O_1—–8 digits, even verification
- F 4.3 Baud rate
- Selectable parameters: 2400, 4800, 9600 (default), 19200
- F 4.4 New line
- Selectable parameters: 0~9 (default: 0)
F 5 Maintenance and Service
F 5.1 Button test
- When the indicator displays
, press〖ON/OFF〗〖ZERO〗〖TARE〗〖GROSS〗 〖PRINT〗and〖COUNT〗in order and the indicator displays “on.off” “Zero” “Tare” “Gross” “Print” and “Count”. Press 〖TOTAL〗to exit.
F 5.3 Inner code
The indicator shows the after-filtering inner code. Press 〖COUNT〗or〖ON/OFF〗to exit.
Functions
Totalization
F 1.10=0
Operation: Normally add weights to scale and press 〖TOTAL〗. The screen shows “Add-” and returns to the main weighing interface. Remember to zero the scale before putting things on scale every time; otherwise, there is no totalization.
Check and clear: Normally long press 〖TOTAL〗and “TOTAL ” shows for one second. Then the total quantity interface “Cn xxx” and the total weight interface “t xx.xx” show. Press〖Print〗or 〖GROSS〗 to switch between the above two interfaces. Press 〖ZERO〗 to clear the total quantity or the total weight value. Press 〖ON/OFF〗 to confirm and press 〖COUNT〗to exit.
Counting
F 1.10=1
Operation: Normally press 〖COUNT〗to switch between the weight and quantity display. Sampling: Long press 〖COUNT〗 until “SAMPLE” shows. Press 〖ON/OFF〗 and as “Sn XXX” shows, put in the correct quantity. If F 2.4=0, put the corresponding quantity on scale and press 〖ON/OFF〗to confirm the sample quantity and weight; if F 2.4=1, press 〖ON/OFF〗 and as “XXXXXX” shows, put in the corresponding weight and press 〖ON/OFF〗 to confirm the sample quantity and weight.
Appendix Ⅰ Indicator Prompt Message
Normally the indicator is stable and reliable. If the indicator fails, restart it first. Find out what the error is before repairing it. Repair the indicator according to the error codes.
Appendix Ⅱ Serial output format
Serial output format HEAD1:OL overload, underload or no zeroing at start-up
- ST the scale is stable
- US the scale is unstable
- HEAD2:GS gross weight
- NT net weight
- DATA: data display
- UNIT: kg/lb
- CR/LF: New line
Example 1: stable, gross weight: 18.000kg, sp = space.
S | T | , | G | S | , | sp | sp | 1 | 8 | . | 0 | 0 | 0 | k | g | 0d | 0a |
Example 2: unstable, net weight: -0.200kg, sp = space.
U | S | , | N | T | , | – | s p | s p | 0 | . | 2 | 0 | 0 | k | g | 0d | 0a |
Appendix Ⅲ Printing Output Format
FAQ
- Q: How do I perform zero calibration?
A: Remove weights off the scale and press ON/OFF. The indicator shows… Finally, … appears for one second and zero calibration ends. - Q: How do I perform load calibration?
A: Add weights to the scale and make sure… Press ON/OFF… Enter the same value as the weights… Wait until the scale is stable…