veratron J1939 Adapter Cable

Product Information
Specifications
- Model: XYZ-2000
- Power: 120V, 60Hz
- Dimensions: 10 x 8 x 6 inches
- Weight: 5 lbs
- Material: Stainless Steel
INTRODUCTION
SYSTEM COMPONENTS
LinkUp Gateway
B000424
- This device will translate all your engine data, which is transmitted on a SAE J1939 CAN bus, to the NMEA2000@ standard, making all the information available for any display,
- Wireless configurable, the LinkUp gateway can be easily set up with your smartphone and the LinkUp Configurator App.

THE LINKUP GATEWAY CONCEPT
- The LinkUp J1939 provides an easy method to convert engine or vessel information to N MEA 2000. The Link Up installation is very easy and quickly done.
- The data is then available for being displayed on any VM H, OceanLink, AcquaLink, or more in general on any glass cockpit NM EA 2000 display device.
- Configuring LinkUp gateways is simple using a smartphone and the companion LinkUp Configurator App for Android or iOS.
- Each device has a built-in, passive NFC antenna, so the parameters of the engine, such as engine instances or the alarm settings, are wirelessly configured on the mobile device which is then “tapped” against the LinkUp device for instant data download.
DESIGN AND FUNCTION
- The LinkUp gateway has a simple but yet effective design.
- The potted housing allows the unit to be installed in engine rooms, making it compliant to the ISO 8846:1990 as requested by the directive 2013-53(EC).
- The standard NM EA 2000@ M12 plug allows for a plug-and-play installation to the network backbone.
- To interface the CAN J1939 connection a Deutsch DT04-6P 6-pole connector provided,
SAFETY INFORMATION
WARNING
No smoking! No open fire or heat sources!
- The product was developed, manufactured and inspected according to the basic safety requirements of EC Guidelines and state-of- the-art technology.
- The instrument is designed for use in grounded vehicles and machines as well as in pleasure boats, including non-classified commercial shipping.
- Use our product only as intended. Use of the product for reasons other than its intended use may lead to personal injury, property damage or environmental damage. Before installation, check the vehicle documentation for vehicle type and any possible special features!
- Use the assembly plan to learn the location of the fuel/hydraulic/compressed air and electrical lines!
- Note possible modifications to the vehicle, which must be considered during installation!
- To prevent personal injury, property damage or environmental damage, basic knowledge of motor vehicle/shipbuilding electronics and mechanics is required.
- Make sure that the engine cannot start unintentionally during installation!
- Modifications or manipulations to veratron products can affect safety. Consequently, you may not modify or manipulate the product!
- When removing/installing seats, covers, etc., ensure that lines are not damaged and plug- in connections are not loosened!
- Note all data from other installed instruments with volatile electronic memories
SAFETY DURING INSTALLATION
- During installation, ensure that the product’s components do not affect or limit vehicle functions, Avoid damaging these components!
- Only install undamaged parts in a vehicle!
- During installation, ensure that the product does not impair the field of vision and that it cannot impact the driver’s or passenger’s head!
- A specialized technician should install the product. If you install the product yourself, wear appropriate work clothing, Do not wear loose clothing, as it may get caught in moving parts, Protect long hair with a hair net.
- When working on the on-board electronics, do not wear metallic or conductive jewelry such as necklaces, bracelets, rings, etc.
- If work on a running engine is required, exercise extreme caution. Wear only appropriate work clothing as you are at risk of personal injury, resulting from being crushed or burned.
- Before beginning, disconnect the negative terminal on the battery, otherwise you risk a short circuit, If the vehicle is supplied by auxiliary batteries, you must also disconnect the negative terminals on these batteries!
- Short circuits can cause fires, battery explosions and damages to other electronic systems. Please note that when you disconnect the battery, all volatile electronic memories lose their input values and must be reprogrammed.
- If working on gasoline boat motors, let the motor compartment fan run before beginning work.
- Pay attention to how lines and cable harnesses are laid so that you do not drill or saw through them!
- Do not install the product in the mechanical and electrical airbag area!
- Do not drill holes or ports in load-bearing or stabilizing stays or tie bars!
- When working underneath the vehicle, secure it according to the specifications from the vehicle manufacturer,
- Drill small ports; enlarge and complete them, if necessary, using taper milling tools, saber saws, keyhole saws or files, Deburr edges, Follow the safety instructions of the tool manufacturer.
- Use only insulated tools, if work is necessary on live parts,
- Use only the multimeter or diode test lamps provided, to measure voltages and currents in the vehicle/machine or boat, Use of conventional test lamps can cause damage to control units or other electronic systems.
- The electrical indicator outputs and cables connected to them must be protected from direct contact and damage, The cables in use must have enough insulation and electric strength and the contact points must be safe from touch,
- Use appropriate measures to also protect the electrically conductive parts on the connected consumer from direct contact, Laying metallic, uninsulated cables and contacts is prohibited,
SAFETY AFTER INSTALLATION
- Connect the ground cable tightly to the negative terminal of the battery.
- Reenter/reprogram the volatile electronic memory values.
- Check all functions.
- Use only clean water to clean the components. Note the Ingress Protection (I P) ratings (IEC 60529)
ELECTRICAL CONNECTION
- Note cable cross-sectional area!
- Reducing the cable cross-sectional area leads to higher current density, which can cause the cable cross-sectional area in question to heat up!
- When installing electrical cables, use the provided cable ducts and harnesses; however, do not run cables parallel to ignition cables or to cables that lead to large electricity consumers.
- Fasten cables with cable ties or adhesive tape. Do not run cables over moving parts, Do not attach cables to the steering column!
- Ensure that cables are not subject to tensile, compressive or shearing forces,
- If cables are run through drill holes, protect them using rubber sleeves or the like.
- Use only one cable stripper to strip the cable.
- Adjust the stripper so that stranded wires are not damaged or separated,
- Use only a soft soldering process or commercially available crimp connector to solder new cable connections!
- Make crimp connections with cable crimping pliers only. Follow the safety instructions of the tool manufacturer,
- Insulate exposed stranded wires to prevent short circuits.
- Caution: Risk of short circuit if junctions are faulty or cables are damaged. Short circuits in the vehicle network can cause fires, battery explosions and damages to other electronic systems. Consequently, all power supply cable connections must be provided with weldable connectors and be sufficiently insulated.
- Ensure ground connections are sound.
- Faulty connections can cause short circuits.
- Only connect cables according to the electrical wiring diagram,
- If operating the instrument on power supply units, note that the power supply unit must be stabilized and it must comply with the following standard: DIN EN 61000, Parts 6-1 to 6-4,
INSTALLATION
WARNING
Before beginning, disconnect the negative terminal on the battery, otherwise you risk a short circuit. If the vehicle is supplied by auxiliary batteries, you must also disconnect the negative terminals on these batteries! Short circuits can cause fires, battery explosions and damage to other electronic systems. Please note that when you disconnect the battery, all volatile electronic memories lose their input values and must be reprogrammed.
BEFORE THE ASSEMBLY
- Before beginning, turn off the ignition and remove the ignition key, If necessary, remove the main circuit switch
- Disconnect the negative terminal on the battery. Make sure the battery cannot unintentionally restart.
- Place the device at least 500 mm away from any magnetic compass.

CONNECT TO THE NMEA 2000 NETWORK
- Connect the LinkUp to the NMEA 2000 network using the round connector. Please ensure to tighten the
- M12 connector by screwing it onto its cou nterpart, so to preserve the water tightness.
- Refer to the N MEA 2000@ standard for a proper network design.
- If power from the N MEA 2000@ network is received, the green LED on the LinkUp housing will start flashing depending on the device’s status. (See section “Troubleshooting” if LED is not constantly on).
- Make sure the NMEA backbone is terminated with two resistors and the bus is powered by a 12V voltage source.

CONNECT TO THE J1939 NETWORK
- The J1939 bus consists of four wires. Next to the two data transmission lines (CAN High and CAN Low) there are two power lines (V+ and ground).
- The data transmission lines must be terminated by resistors.
- It is required to power the LinkUp also from the J1939-side as the two sides of the LinkUp are completely galvanically separated, It is recommended to use the power lines provided by the J1939 bus to power the LinklJp Gateway.
- If possible, use the provided Deutsch connector to interface the LinkUp Gateway to your vessel.
- If the vessels engine is not equipped with the matching counterpart it is possible to either crimp the fitting female connector on it (connector details in section “Technical Data”), or simply cut-off the plug on the LinkUp and manually connect the wires, For this, refer to the pinout description, provided in the section “Technical Data”.
- Additional adapter cables can be purchased as accessories to interface the typical installations of Volvo Penta (B001027) and Yanmar (B001028) engines without the need to manually confection cables.
CONNECTION ON VOLVO PENTA ENGINES
- Installations on Volvo Penta engines with EVC support can be done easily with the accessory adapter cable (B001027).
- These engines require an additional connection to the two remaining pins on the 6 pin Deutsch connector.
- A connection between the pins “CAN Low I” with “CAN Low 2” and another one between “CAN High I” and” CAN High 2″.
- The adapter cable comes with a termination plug, This plug can be on the adapter instead of making the connection mentioned above manually.
- Make sure to use the Deutsch connector with only four wires to connect the LinkUp.
- The end with all six wires is meant for the termination connector (if no other devices are connected to the bus) or for connecting additional devices to the bus (e.g. original Volvo Penta instrumentation),

CONFIGURATION
LINKUP CONFIGURATOR APP
To configure your system, some parameters must be calibrated through the LinkUp gateway, These parameters are:
- number of engines, which should be analyzed through this gateway
- the engine instances of these engines
- which alarms you want to receive on your dashboard
- This is possible through the “LinkUp Configurator” smartphone App, which can be downloaded free of charge from the stores of both Android and iOS devices.
- A simple and detailed explanation of the configuration process is also available as in-app instructions.
- Thanks to the passive embedded NFC receiver, the LinkUp gateway can be configured, as described below, without the need for a power supply.

GATEWAY CONFIGURATION
- Launch the “Link Up Configurator” App and read the actual configuration of the LinkUp device by “tapping” the smartphone onto the LinkUp wireless area (indicated by the red arrow),
- NOTE: The antenna position on the smartphone depends on the model. Please refer to the smartphone manufacturer manual.

- NOTE: The antenna position on the smartphone depends on the model. Please refer to the smartphone manufacturer manual.
- After the readout, the App will show the “Configuration Summary”, which displays all the current settings of the device,
To modify the configuration, press the “Change Configuration” button.
Select whether you’ve got one or two engines on your vessel.
- Then choose for each engine its source number that is used in the J1939 system as well as the instance which should be used in the NMEA 2000 network.

- After that, you can choose, which alarms you want to show up on your dashboard.
Once the settings are completed, press the “Write Configuration” button to prepare the download,
See the “Supported Alarms” section of this manual for the complete list of supported alarms.
- To download the configuration, simply “tap” the smartphone again onto the LinkUp wireless area, as described on step 1,
The configuration is instantaneously transferred to the device, and the new “Configuration Summary” is displayed.
SUPPORTED DATA

SUPPORTED ALARMS
LED NOTIFICATION
TECHNICAL DATA
DATASHEET
DIMENSIONS

PINOUTS

TROUBLESHOOTING

REVISION HISTORY
- veratron AG
- Industriestrasse 18
- 9464 Rüthi, Switzerland
- T +41 71 7679111
- info@veratron.com
- veratron.com
Any distribution, translation or reproduction, partial or total, of the document is strictly prohibited unless with prior authorization in writing from veratron AG, except for the following actions:
- Printing the document in its original format, totally or partially.
- Copying contents without any modifications and stating Veratron AG as copyright owner.
- Veratron AG reserves the right to make modifications or improvements to the relative documentation without notice.
- Requests for authorization, additional copies of this manual or technical information on the latter, must be addressed to veratron AG.
Frequently Asked Questions
Can this product be used for outdoor purposes?
No, this product is designed for indoor use only.
How often should I clean the product?
It is recommended to clean the product after each use to maintain hygiene and performance.
What should I do if the product malfunctions?
If you encounter any issues with the product, refer to the troubleshooting section in the user manual or contact customer support for assistance.
Documents / Resources
![]() |
veratron J1939 Adapter Cable [pdf] User Manual B001030, J1939 Adapter Cable, J1939, Adapter Cable, Cable |