Features & Specifications

Features

  • Count up or down.
  • Count input trough on-board push buttons or by external pulses.
  • Display modes : Normal or time (hh:mm and mm:ss).
  • An internal oscillator allows time measurement.
  • Programmable pre-set value with equal output.
  • Self diagnostic at power up.
  • Comes whit easy board to wire connector (20cm wire).
  • Comes in handy for people counting, part counting, score keeping,

Specifications

  • Counter Input : 3…12 VDC (normal dry contact also possible)
  • EQUAL Output : 5VDC / max 50mA
  • Max. Counting speed : 200 / sec. (2 / sec. with long debounce delay)
  • Max. Count : 4 Digits (9999 / 23h59m / 59m59s)
  • Power supply : 9…12 VDC or transformer 2 x 9 VAC type : 209005
  • Power consumption : 150mA max.
  • Dimensions : 125 x 75 x 18mm (4,9”x3”x0,7”)

Assembly (Skipping this can lead to troubles ! )

Ok, so we have your attention. These hints will help you to make this project successful. Read them carefully.

Make sure you have the right tools: 

Tools

  • A good quality soldering iron (25-40W) with a small tip.
  • Wipe it often on a wet sponge or cloth, to keep it clean; then apply solder to the tip, to give it a wet look. This is called ‘thinning’ and will protect the tip, and enables you to make good connections. When solder rolls off the tip, it needs cleaning.
    Tools
  • Thin raisin-core solder. Do not use any flux or grease.
  • A diagonal cutter to trim excess wires. To avoid injury when cutting excess leads, hold the lead so they 6k09 cannot fly towards the eyes.
    Tools
  • Needle nose pliers, for bending leads, or to hold components in place.
  • Small blade and Phillips screwdrivers. A basic range is fine.

For some projects, a basic multi-meter is required, or might be handy
Tools

Lite Icon Assembly Hints

  • Make sure the skill level matches your experience, to avoid disappointments.
  • Follow the instructions carefully. Read and understand the entire step before you perform each operation.
  • Perform the assembly in the correct order as stated in this manual
  • Position all parts on the PCB (Printed Circuit Board) as shown on the drawings.
  • Values on the circuit diagram are subject to changes.
  • Values in this assembly guide are correct*
  • Use the check-boxes to mark your progress.
  • Please read the included information on safety and customer service

Typographical inaccuracies excluded. Always look for possible last minute manual updates, indicated as ‘NOTE’ on a separate leaflet

Soldering Hints :

  1. Mount the component against the PCB surface and carefully solder the leads
    Soldering Hints
  2. Make sure the solder joints are cone-shaped and shiny
    Soldering Hints
  3. Trim excess leads as close as possible to the solder joint
    Soldering Hints

REMOVE THEM FROM THE TAPE ONE AT A TIME !

Soldering Hints

AXIAL COMPONENTS ARE TAPED IN THE CORRECT MOUNTING SEQUENCE !

Jumpers

  • J : 10x
    Jumpers

 

Diodes. Watch the polarity !

  • D1: 1N4007
  • D2: 1N4007
  • D3: 1N4148
  • D4: 1N4148
  • D5: 1N4148
  • D6: 1N4148
  • D7: 1N4148
    Wirning Instrcutions

Zener diode. Watch the polarity !

  •  ZD1 : 4V7
  • ZD2 : 4V
    Wirning Instrcutions

Resistors

  • R9 : 10K (1-0-3-B)
  • R10 : 10K (1-0-3-B)
  • R11 : 10K (1-0-3-B)
  • R12 : 10K (1-0-3-B)
  • R13 : 10K (1-0-3-B)
  • R14 : 2K2 (2-2-2-B)
  • R15 : 2K2 (2-2-2-B)
  • R16 : 2K2 (2-2-2-B)
  • R17 : 2K2 (2-2-2-B)
  • R18 : 4K7 (4-7-2-B)
  • R19 : 4K7 (4-7-2-B)
  • R20 : 10K (1-0-3-B)
  • R21 : 10K (1-0-3-B)
  • R22 : 10K (1-0-3-B)
  • R23 : 10K (1-0-3-B)
  • R24 : 10K (1-0-3-B)
  • R25 : 10K (1-0-3-B)
  • R26 : 10K (1-0-3-B)
  • R27 : 10K (1-0-3-B)
  • R28 : 390 (3-9-1-B)
    Wirning Instrcutions

Pushbuttons

  • SW1: KRS1243
  • SW2: KRS1243
  • SW3: KRS1243
  • SW4: KRS1243
    Wirning Instrcutions

Voltage Regulator.

  • VR1: UA7805
    Wirning Instrcutions

IC sockets. Watch the position of the notch!

  • IC1 : 28P
  • DY1 : 14P
  • DY2 : 14P
  • DY3 : 14P
  • DY4 : 14P
    Wirning Instrcutions

LED. Watch the polarity!

  • LD1 : 3mm Red.
    Wirning Instrcutions

Ceramic Capacitors 

  • C1 : 18pF (18,18J)
  • C2 : 18pF (18,18J)
  • C3 : 100nF (104)
  • C4 : 100nF (104)
  • C5 : 100nF (104)
  • C6 : 1nF (102)
  • C7 : 1nF (102)
    Wirning Instrcutions

Transistors

  • T1 : BC557C
  • T2 : BC557C
  • T3 : BC557C
  • T4 : BC557C
  • T5 : BC557C
  • T6 : BC547
  • T7 : BC547
    Wirning Instrcutions

Resistors

  • R1 : 150 (1-5-1-B)
  • R2 : 150 (1-5-1-B)
  • R3 : 150 (1-5-1-B)
  • R4 : 150 (1-5-1-B)
  • R5 : 150 (1-5-1-B)
  • R6 : 150 (1-5-1-B)
  • R7 : 150 (1-5-1-B)
  • R8 : 150 (1-5-1-B)

Connector

  • 10p
    Wirning Instrcutions

DIP Switch

  • DS – 4
    Wirning Instrcutions

Quartz crystal

  • X1: 4,1943… MHz.
    Wirning Instrcutions

Electrolytic capacitor. Watch the polarity !

  • C8 : 470µF
  • C9 : 10µF
    Wirning Instrcutions

Display

  • SA39-11EWA
    Wirning Instrcutions

IC, Check the position of the notch !

  • IC1: VK8035 (Programmed PIC16C5
    Wirning Instrcutions

Connection

Wirning Instrcutions

Wirning Instrcutions

1 GND 6 GND
2 + VA 7 + 5V
3 + VB 8 Count Down input (B)
4 GND 9 Count Up input (A)
5 E. OUT 10 GND

Note Icon The grounds are internally connected.

E.out : 5V / 50mA max. output at “equal” pre-set value

Inspect the complete assembly once more before applying power to the unit !

Hook-up when using an adapter

Using Adapter

Hook-up when using a transformer

Using Transformer

Operation

When all connections are made, the four LED displays will light up and the Kit number will appear “8 0 3 5”after which following messages appear :

r x. x x Version number
T E S T Self-test is working
G O O D Internal parts are working correctly

If an irregularity is found during the self-test, an error code will appear, when GOOD appears then the unit is ready for u

Error code Description
Err. 2 Error in the keyboard section.
Err. 3 The switches are in the wrong position. ’DIP SWITCH’
Err. 4 Input A and B are at the same time active
Err. 5 Input A is active during self-test or input A is possibly malfunctioning.
Err. 6 Input B is active during self-test or input B is possibly malfunctioning.

The errors 5 & 6 can appears when during the self-test counter pulses are received, this can be reset by pressing SW4 briefly.

Counting pulses can be applied to the unit in two different ways : 

  1. + 3V to 12V pulses with respect to ground.
  2. Use the + 5V connection for push buttons or relay contacts when there is no power supply from an external source.
  • Press “Reset” button briefly to reset the readout. “0000”.
  • Press the “UP” button to increase the actual value with one.
  • Press the “DOWN” button to decreases the actual value with one.

Setting the Pre-set value:
It is possible to set a number which will continuously be compared with the content of the counter. If both are equal, then the output (Equal OUT) is activated.

  • Press Set/Run (set briefly appears).
  • Press Up or Down to set the value.
  • Press Set/Run to store the value (Run appears).

Counter settings :
The counter can be used for decade or modulo 60 (clock) counting, an internal oscillator can be provided for use in modulo 60-mode

1. COUNTER SETTINGS
FUNCTION DIP SWITCH
OFF ON
Decade counter 1
Modulo 60 : hh:mm (23.59) 2 1
Modulo 60 : mm:ss. (59.59) 1 & 2
2. DEBOUNCE SETTING
Normal debounce 3
Long debounce 3
3. INPUT SETTING
External pulses 4
Internal oscillator 4

Note IconATTENTION : When changing the position of one of the switches, the current counter value and the pre-set value will be erased. (0000)

PCB

PCB INSTRCUCTIONS

Schematic diagram.

Schematic diagram.
Schematic diagram.

VELLEMAN Components NV
Legen Heirweg 33
9890 Gavere
Belgium Europe
www.velleman.be
www.velleman-kit.com

Modifications and typographical errors reserved © Velleman Components nv. H8035IP – 2003 – ED1

velleman Logo

Documents / Resources

velleman K8035 Advanced UP/DOWN Counter [pdf] Installation Guide
K8035 Advanced UP DOWN Counter, K8035, Advanced UP DOWN Counter, UP DOWN Counter, DOWN Counter, Counter

References

Leave a comment

Your email address will not be published. Required fields are marked *