HOCHIKI-LOGO

HOCHIKI DCP-SOM-AI sinf A nazorat qilinadigan chiqish moduli

HOCHIKI-DCP-SOM-AI-sinfi-nazorat qilinadigan-chiqish-modul-mahsulot

Texnik xususiyatlari

  • Nominal diapazon: 25.3 ~ 39 VDC
  • Signalning ishlashi:
    • Signal LED yoniq:
      • SOM-AI: 7.5 mA
      • SOM-A: 7.3 mA
    • Oddiy operatsiya:
      • SOM-AI: 520uA
      • SOM-A: 320uA
  • Yordamchi amaliy jildtage: 24VDC
  • Yordamchi oqim iste'moli: maksimal chiqish oqimi
    (OUT+/OUT-, IN+/IN-): 2A @ 24VDC
  • OUT+ & OUTSCI uchun EOL qurilmasi: HOCHIKI AMERICA CORP. EOL
    Qism NO. 0400-03180 10K, 1/4 Vt, 1/4 dyuym
  • Qarshilik bo'yicha: SCI xatosini aniqlash chegarasi
  • SCI izolyatsiya oqimi (qisqa tutashuv holati): Maksimal
    Har bir tsikl uchun miqdor vizual ko'rsatkichi (status LED)
  • Ishlash harorati oralig'i: Saqlash harorati Maks. Qarindosh
    Namlik muhiti
  • Olchamlari: 4.2WX 4.7HX 1.0D
  • Og'irligi: Taxminan 3.0 untsiya

Mahsulotdan foydalanish bo'yicha ko'rsatmalar

Umumiy tavsif

A sinfidagi nazorat qilinadigan chiqish moduli (SOM-A va SOM-AI) DCP-mos keladigan signalizatsiya liniyasiga (SLC) ulanish uchun mo'ljallangan. U shoxlar, qo'ng'iroqlar va stroblar kabi ovozli va vizual yong'in signalizatsiya qurilmalari uchun nazorat qilinadigan 24VDC quvvatni ta'minlaydi, shuningdek, ochiq va qisqa tutashuv holatlarini nazorat qilishni taklif qiladi.

LED holati

Modulda chiqish modulining ish holatini ko'rsatadigan holat LED mavjud.

O'rnatishga qo'yiladigan talablar

DCP-SOM-A nazorat qilinadigan chiqish modulini o'rnatish bo'yicha yo'riqnomaning 2-betidagi rasmlarda ko'rsatilganidek o'rnating.

Simlarni ulash bo'yicha ko'rsatmalar

  1. Ish chizmalariga va tegishli ulanish sxemalariga muvofiq modul simlarini o'rnating.
  2. Modulni UL ro'yxatidagi elektr qutisiga mahkamlang.
  3. Qopqoq plitani ulashdan oldin moduldagi manzilni o'rnating.

Ogoh bo'ling

Panel ko'rsatmalariga muvofiq modulni faqat mos keluvchi yong'inni boshqarish paneliga ulab, to'g'ri ishlashini ta'minlang. Mavjud tizimga o'rnatayotgan bo'lsangiz, o'rnatishdan oldin operatorga xabar bering va boshqaruv panelidagi quvvatni uzing.

Eslatma

Yong'in signalizatsiyasi moslamalarini o'rnatish vaqtida ularni potentsial radiochastota yoki elektromagnit manbalariga yaqin joyda joylashtirishdan saqlaning. SLC sxemasini elektr uzatish liniyalari bilan bir xil quvurda ishlatmang. Shovqinli muhitda o'ralgan juftlik va ekranlangan simdan foydalaning.

DCP-SOM-AI, DCP-SOM-A SINFLARINI O‘RNATISH BO‘YICHA KO‘RSATMALAR BOSHQARILGAN CHIKARISh MODULI

Ushbu o'rnatish yo'riqnomasida keltirilgan ma'lumotlar tezkor ma'lumotnomadir. Tizim haqida batafsil ma'lumot olish uchun panel ishlab chiqaruvchisining o'rnatish qo'llanmasiga qarang. Ushbu ko'rsatma maxsus dasturlash tartibini ko'rib chiqmaydi.

UMUMIY TAVSIF

Ushbu ko'rsatma DCP-mos keladigan signalizatsiya liniyasiga (SLC) ulanishi kerak bo'lgan A sinfidagi nazorat qilinadigan chiqish moduli (SOM-A va SOM-AI) uchun amal qiladi. Odatda ilovalar shoxlar, qo'ng'iroqlar, stroblar va boshqalar kabi ovozli va vizual yong'in signalizatsiya qurilmalarini boshqarish uchun nazorat ostida 24VDC quvvat bilan ta'minlashdir. Bildirishnoma qurilmasi chiqishi ochiq va qisqa tutashuv holatlarini nazorat qiladi. Qurilmaning ishlashi va signalizatsiya qurilmalarini quvvatlantirish uchun yordamchi quvvat kiritishidan foydalanadi.

O'RNATISH TALABLARI

DCP-SOM-A nazorat qilinadigan chiqish moduli ushbu yo'riqnomaning 2-betidagi 2-rasmda ko'rsatilganidek o'rnatilgan.

Elektr simlari

ESLATMA: Barcha simlar mahalliy qonunlar, qoidalar va qoidalarga muvofiq bo'lishi kerak

  1. Modul simlarini ish chizmalariga va tegishli ulanish sxemasiga muvofiq o'rnating (3 va 4-rasmga qarang).
  2. 2-rasmda ko'rsatilganidek, modulni UL ro'yxatidagi elektr qutisiga (o'rnatuvchi tomonidan taqdim etiladi) mahkamlang.
  3. Qopqoq plitasi biriktirilgunga qadar modulda manzil o'rnatilishi kerak (1-rasmga qarang).

DIQQAT

  • TO'G'RI ISHLATILISHINI TA'MINLASH UCHUN USHBU MODULNI FAQAT MUVOFIQ YONG'INNI BOSHQARISH PANELiga ulaning. TO'G'RI ULLANISH VA MUVOFIQLIK UCHUN PANEL KO'RSATMALARIGA O'RING.
  • AGAR USHBU MODUL MAVJUR AMALIYOT TIZIMGA O'RNATISA, TIZIM VAQINCHA XIZMAT TO'XTIRISHI HAQIDA operator va mahalliy hokimiyatga xabar bering. MODULNI O‘RNATISHDAN OLDIN BOSHQARUV PANELI QUVVATNI UZING.

ESLATMA: Yong'in signalizatsiyasi qurilmalarini o'rnatayotganda, qurilmalarni yoki simlarni potentsial radio chastotasi yoki elektromagnit manbalariga yaqin qo'ymang. SLC sxemasini elektr uzatish liniyalari bilan bir xil quvurda ishlatishdan saqlaning. Haddan tashqari shovqin kutilayotgan muhitda o'ralgan juftlik va ekranlangan simdan foydalaning.

XUSUSIYATLAR
SLC Applied Voltage Nominal diapazon 25.3 ~ 39 VDC
SLC joriy iste'moli Signalning ishlashi Signal LED yoniq: SOM-AI: 7.5mA, SOM-A: 7.3mA Oddiy ish SOM-AI: 520uA, SOM-A: 320uA
Yordamchi amaliy jildtage Nominal 24VDC
24VDC yordamchi oqim iste'moli 50 A (odatiy)
Maksimal chiqish oqimi (OUT+/OUT-, IN+/IN-) 2A @ 24VDC
OUT+ va OUT- uchun EOL qurilmasi HOCHIKI AMERICA CORP. EOL Qism №. 0400-03180 10KŌ, 1/4 Vt, 1/4 dyuym
Qarshilik bo'yicha SCI 60mŌ maksimal (normal holat)
SCI xatosini aniqlash chegarasi 12 volt (odatiy)
SCI izolyatsiya oqimi (qisqa tutashuv holati) 10mA (odatiy)
Har bir tsikl uchun maksimal miqdor 127
Vizual indikator (status LED) Ikki rangli LED - yashil va qizil

Rang va rejim - Boshqarish paneli dasturi tomonidan tanlangan va dasturlashtirilgan

Ishlash harorati oralig'i 0°C (32°F) ~ 49°C (120°F)
Saqlash harorati -30°C (-22°F) ~ 70°C (158°F)
Maks. Nisbiy namlik 90% gacha RH Kondensatsiz
Atrof-muhit Faqat bino ichida quruq foydalanish
O'lchamlari 4.2″WX 4.7″HX 1.0″D
Og'irligi Taxminan 3.0 untsiya

MODELLAR

DCP-SOM-AI o'rnatilgan SCI qisqa tutashuv izolyator sxemasiga ega. DCP-SOM-A SCI qisqa tutashuv izolyatori sxemasini o'z ichiga olmaydi.

INTEGRATSION SCI QISQA tutashuv izolyatorining ishlashi

DCP-SOM-AI o'rnatilgan SCI sxemasiga ega. S-SC liniyasida qisqa tutashuv sodir bo'lgan taqdirda, SCI davri o'zining Sariq LED indikatorini faollashtiradi va SOM-AI moduli qisqa tutashuv holati haqida Yong'inni boshqarish paneliga xabar beradi.
SCI tez javob berish vaqtiga ega, ammo Boshqaruv paneli SCI zanjiri uzilishidan oldin qisqa vaqtni aniqlaydi, agar qisqa vaqt normal ish paytida ro'y bersa. Biroq, agar S-SC liniyasi yoqishdan oldin qisqa bo'lsa, Boshqarish paneli faqat ochiq tsiklni aniqlaydi, chunki SCI o'tish davri hech qachon yopilmaydi. Bunday holda, u qisqacha hisobot berish uchun SOM-AIga tayanadi.
SCI sxemasi qisqa tutashuv sodir bo'lgan taqdirda butun tsiklning ishdan chiqishini oldini oladi. Qisqa holatni olib tashlangandan so'ng, SCI avtomatik ravishda butun tsiklni normal ish holatiga qaytaradi.

HOCHIKI-DCP-SOM-AI-A-sinfi-nazorat qilinadigan-chiqish-modul-FIG-2 HOCHIKI-DCP-SOM-AI-A-sinfi-nazorat qilinadigan-chiqish-modul-FIG-3

ESLATMA

  • SLC qurilmalarining har bir tsikli uchun o'rtacha 6.75 mA (aloqa oqimi) panel batareyasining zaxira hisob-kitoblariga kiritilishi kerak.
  • NAC o'rnatish simlari 2 ohmdan oshmasligi kerak (14-18 AWG)
  • SLC sxemasi S va SC ga tegishli

HOCHIKI-DCP-SOM-AI-A-sinfi-nazorat qilinadigan-chiqish-modul-FIG-4

HOCHIKI-DCP-SOM-AI-A-sinfi-nazorat qilinadigan-chiqish-modul-FIG-9

HOCHIKI-DCP-SOM-AI-A-sinfi-nazorat qilinadigan-chiqish-modul-FIG-7 HOCHIKI-DCP-SOM-AI-A-sinfi-nazorat qilinadigan-chiqish-modul-FIG-8

Bir yillik Cheklangan Kafolat

Hochiki America (HA) oʻzining raqamli aloqa modullarini oʻzining rejalari va texnik xususiyatlariga muvofiqligini hamda yetkazib berilgan kundan boshlab bir (1) yil davomida normal foydalanish va xizmat koʻrsatish sharoitida materiallar va mahoratdagi nuqsonlardan xoli boʻlishini kafolatlaydi. Barcha kafolatlar o'z kuchini yo'qotadi va HA boshqalar tomonidan ta'mirlangan, suiiste'mol qilingan, noto'g'ri o'rnatilgan, o'zgartirilgan yoki boshqa tarzda noto'g'ri foydalanilgan yoki shikastlangan yoki mahsulot spetsifikatsiyalaridan tashqari sharoitlarga duchor bo'lgan uskunani ta'mirlash yoki almashtirishga majbur emas. HA demontaj, qayta yig'ish yoki qayta o'rnatish uchun to'lovlar uchun javobgar bo'lmaydi. Iltimos, da'volar va tovarni qaytarishning tegishli tartibi uchun HA savdo bo'limiga murojaat qiling. Ushbu kafolat ifodalangan yoki nazarda tutilgan barcha boshqa kafolatlar o'rniga.

TSS

Savol: DCP-SOM-A modulini har qanday yong'inni boshqarish paneliga o'rnatishim mumkinmi?

Javob: Yo'q, to'g'ri ishlash bo'yicha ko'rsatmalarda aytib o'tilganidek, ushbu modulni faqat mos keluvchi yong'inni boshqarish paneliga ulaganingizga ishonch hosil qiling.

Savol: Moduldagi manzilni qanday o'rnatishim mumkin?

Javob: Qopqoq plitani ulashdan oldin manzil modulga o'rnatilishi kerak. Portlash uchun 1-rasmga qarang view manzilni dasturlash vilkasi va ulagichi.

Hujjatlar / manbalar

HOCHIKI DCP-SOM-AI sinf A nazorat qilinadigan chiqish moduli [pdf] Qo'llanma
DCP-SOM-AI, DCP-SOM-A, DCP-SOM-AI sinfi nazorat qilinadigan chiqish moduli, DCP-SOM-AI, nazorat ostidagi chiqish moduli A sinfi, nazorat qilinadigan chiqish moduli, chiqish moduli, modul

Ma'lumotnomalar

Fikr qoldiring

Sizning elektron pochta manzilingiz nashr etilmaydi. Majburiy maydonlar belgilangan *