Uponor Base thermostat digital programmable T-26, 230 V
Guick guide
Pos A | Pos B |
Floor sensor (optional) | Remote sensor (optional) |
Icons
![]() |
Heat on |
![]() |
Frost protection on |
![]() |
Key lock |
![]() |
Floor set temperature |
Time & temperature schedule
Default screen
- Press
twice
- Use
to adjust time
- Press H to accept
- Use
to adjust day of the week
- Press A to exit
- Press
once
- Use
to adjust wake time
- Use H to accept
- Use
to adjust temperature
- Press H to accept
- Press
to adjust leave time
- Press H to accept
- Use
to adjust temperature
- Press H to accept
N.B. Uponor recommend reducing the occupied temperature by 4 °C
- Use
to adjust return time
- Press H to accept
- Use
to adjust temperature
- Press H to accept
- Use
to adjust sleep time
- Press H to accept
- Use
to adjust temperature
- Press H to accept
- Repeat page 8 to 15 for weekend time and temperature schedule
- Press A at end of sequence to store and exit
Standby mode
- Press and hold
to switch off
Settings
- Press and hold
to switch off
- Press and hold
until the screen shown above is displayed
Sensor selection
- Select function 06 by pressing
- Use
to select sensor mode
00 = built in air sensor only
01 = remote air sensor only
02 = floor sensor only
03 = floor sensor and built in air sensor
04 = floor and remote air sensor - Press A to store and exit
- Press
to return to main screen
Floor limiting sensor
- Select function 07 by pressing
- Use
to adjust floor temperature
- Press A to store and exit
- Press
to return to main screen
Temperature set-point
- Press
to adjust temperature
- Press A to accept
- Temperature is now set until the next scheduled change
Floor temperature
- Press and hold A to view floor temperature
- Floor temperature will display for 5 seconds
Frost protection
Press to enable frost protection
Press to disable frost protection
Feature | Description | Setting |
1 | Temperature format | 00 = °C 01 = °F |
2 | Switching differential |
01-03 °C (01 °C default) |
3 | Frost mode | 00 = enabled (default) 01 = disabled |
4 | Output delay | 00-15 minutes (00 default) |
5 | Up/down temp. limit | 00-10 °C (00 °C default) |
6 | Sensor selection | 00 = built in air sensor (default) 01 = remote air sensor 02 = floor sensor only 03 = floor sensor and built in air sensor 04 = floor sensor and remote air sensor |
7 | Floor limiting sensor | 20-45 °C (27 °C default) |
8 | Optimum start | 00-03 (00 hours default) |
9 | Rate of change | Minutes to raise by 1 °C |
10 | Mode select | 00 = 5/7 day programming (default) 01 = 7 day programming 02 = 24 h programming |
11 | Thermostat mode | 00 = manual 01 = programmable (default) |
Uponor reserves the right to make changes, without prior notification, to the specification of incorporated components in line with its policy of continuous improvement and development.
Ref: UPN PRT-EV2
Uponor GmbH
Industriestraße 56,
D-97437 Hassfurt, Germany
1095608 v5_04_2022_INT
Production: Uponor/ELO
www.uponor.com
Documents / Resources
![]() |
Uponor T-26 Base Thermostat Digital Programmable [pdf] User Guide T-26, T-26 Base Thermostat Digital Programmable, Base Thermostat Digital Programmable, Thermostat Digital Programmable, Digital Programmable |