Uplink 5530M Interlogix NX-8
Contents
hide
CAUTION
- It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
- Do not route any wiring over circuit board.
- Full panel testing, and signal confirmation, must be completed by the installer.
NEW FEATURE: For 5530M Communicators, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialer. Therefore, wiring the white wire and programming of the status PGM of the panel is optional.
IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the initial pairing procedure.
Wiring the 5530M communicators to Inter logix NX-8
Wiring the 5530M with UDM to Inter logix NX-8 for remote upload/download
Programming the Inter logix NX-8 Alarm Panel via the Keypad
Enable Contact ID reporting:
LED | Keypad Entry | Action Description |
LEDSs of Ready, Power Steady ON | *8 9713 | To enter programming mode |
Service LED blinks | 0# | To go to main panel programming menu |
Service LED blinks, Armed LED steady ON | 0# | To enter phone number menu |
Service LED blinks, Ready LED steady ON | 15*1*2*3*4*5*6*# | 15* (to choose phone dialing), followed by your desired phone number (123456 is just an example) each figure is followed by *, # to save and go back |
Service LED blinks, Armed LED steady ON | 1# | To go to account number menu |
Service LED blinks, Ready LED steady ON | 1*2*3*4*# | Enter the desired account number (1234 is an example), # to save and go back |
Service LED blinks, Armed LED steady ON | 2# | To go to communication format |
Service LED blinks, Ready LED steady ON | 13* | To choose Contact ID, * to save |
All Zone LEDs are ON | 4# | To go to events reported to phone 1 |
All Zone LEDs are ON | * | To confirm all events reporting and go to next section |
All Zone LEDs are ON | * | To confirm all events reporting and go back |
Service LED blinks, Armed LED steady ON | 23# | To go to feature report section |
Service LED blinks, Ready LED steady ON | ** | To go to section 3 of the toggle options menu |
Ready Led steady ON | 1* | To enable Open/Close reporting |
Service LED blinks, Armed LED steady ON | Exit, Exit | Press “Exit” two times to exit programming mode |
Program Key switch zone and output:
LED | Keypad Entry | Action Description |
LEDSs of Ready, Power Steady ON | *8 9713 | To enter programming mode |
Service LED blinks | 0# | To go to main panel programming menu |
Service LED blinks | 25# | To go to zone type menu |
Service LED blinks, Ready LED steady ON | 11*# | To set Zone 1 as a Momentary Key switch, *# to save and go back |
Service LED blinks, Armed LED steady ON | 47# | To go to AUX 1 Output events and time menu |
Service LED blinks, Ready LED steady ON | 21* | To choose armed state event as an event that will activate the AUX 1 |
Service LED blinks, Ready LED steady ON | 0* | To disable the output timer (the hold status) |
Service LED blinks, Armed LED steady ON | Exit, Exit | Press “Exit” two times to exit programming mode |
Programming the GE Inter logix NX-8 Alarm Panel via the Keypad for remote Upload/Download (UDL)
Program the Panel for Upload/Download (UDL):
Display | Keypad Entry | Action Description |
System ready | *89713 | Enter programming mode. |
Enter device address | 00# | To go to main edit menu. |
Enter location | 19# | Start configuring “Download Access Code”. By default, it is “84800000”. |
Loc#19 Seg# | 8, 4, 8, 0, 0, 0, 0, 0, # | Set the Download Access Code to its default value. Press # to save and go back. IMORTANT! This code should match the one set in the “DL900” software. |
Enter location | 20# | To go to “Number of rings to answer” menu. |
Loc#20 Seg# | 1# | Set number of rings to answer to 1. Press # to save and go back. |
Enter location | 21# | Go to “Download control” toggle menu. |
Loc#21 Seg# | 1, 2, 3, 8, # | All of these (1,2,3,8) should be OFF in order to disable “AMD” and “Call back”. |
Enter location | Exit, Exit | Press “Exit” twice to exit programming mode. |
Documents / Resources
![]() |