UNI-T-LOGO

UNI-T UTi320V Plus Thermal Imager

UNI-T UTi320V-Plus-Thermal-Image-PRODUCT-IMAGE

PREFACE
Thank you for purchasing the new UTi320V+ thermal imager. In order to use this product safely and correctly, please read this manual thoroughly, especially the cautions part.
After reading this manual, it is recommended to keep the manual at an easily accessible place, preferably close to the device, for future reference.

LIMITED WARRANTY AND LIABILITY
Uni-Trend guarantees that the product is free from any defect in material and workmanship within one year from the purchase date. This warranty does not apply to damages caused by accident, negligence, misuse, modification, contamination and improper handling. The dealer shall not be entitled to give any other warranty on behalf of Uni-Trend. If you need warranty service within the warranty period, please contact your seller directly.
This warranty is the only compensation you can obtain. Uni-Trend will not be responsible for any special, indirect, incidental or subsequent damage or loss caused by any reason or speculation. As some areas or countries do not allow limitations on implied warranties and incidental or subsequent damage, the above limitation of liability and stipulation may not apply to you.

cautions

  1. Use or store the product at specified operating or storage temperatures. Otherwise, the device may be damaged.
  2.  Do not direct the product at high intensity thermal radiation sources, such as the sun, laser device, spot-welder, etc.
  3. Do not knock, toss, or shake the product and accessories.
  4. Do not place the battery in a high temperature environment or near high temperature objects. Do not short-circuit the positive and negative electrodes of the battery. Do not place the battery in a humid environment or water.
  5. Do not expose the device to dusty or damp environment. When used in an environment with water, avoid water splashing on the product.
  6. Do not use dissolved or similar liquids on the product or cables, as it may cause device damage.
  7. Please follow the following instructions when wiping the device:
    Non-optical surface: If necessary, use a clean and soft cloth to wipe the non-optical surface of the thermal imager.
    Optical surface: Do not stain the optical surface of the lens when using the thermal imager. Be especially careful not to touch the lens with hands, as sweat from hands will leave marks on the lens glass and may erode the optical coating layer on the glass surface. When the optical surface is stained, carefully wipe it with a special lens paper.
  8. When using the device, please try to keep it stable and avoid violent shaking.
  9. Please close the lens cover and put the product and its accessories into the carrying box when it is not used.
  10. Please do not disassemble the device to avoid product damage and loss of warranty rights.
  11. Due to different batches, the materials and details of actual products may be slightly different from the graphic information. Please refer to the goods received.
  12. The experimental data in the manual are theoretical values and all from Uni-Trend’s internal laboratories, for reference only. Customers cannot use them as bases for placing orders. If users have any questions, please contact customer service.
  13. When the temperature is close to the scale switching critical point (about 150’C), due to the sensor’s own factors, the temperature measurement accuracy may exceed +/-2%, which is normal.

SpecificationsUNI-T-UTi320V-Plus-Thermal-Imager-18

PC analysis software (real-time image, photo download, real-time oontrol and analysis)
Smartphone APP iOS, Android
LED flashlight (two LEDs, white light)
Image modes Thermal, digital, T-Mix fusion.PIP
Image capture mode Photo capture, time-lapse photography, video recording
Image saving format JPG
QR code scanning
Audio Built-in speaker and microphone
Touch screen
Certificates CE,FCC,UKCA,ROHS
Operating temperature -10°C-50°C (14°F-122°F)
Storage temperature -20°C-60°C (-4°F-140°F)
Operating humidity 10%-95%RH (non-condensing)
Battery Detachable Li-ion battery pack with 5200mAh (UT-M17)
Auto power off OFF,5min,10min,20min,30min.45min,60min.90min
Operating time > 4h
Charging time < 5h
Charging voltage/current 5V/2A
Image storage Micro SD card
IP rating IP54
Drop proof 2m
Altitude < 2000m (indoor use)

Structure

UNI-T-UTi320V-Plus-Thermal-Imager-01

UNI-T-UTi320V-Plus-Thermal-Imager-19

LCD Indicators/IconsUNI-T-UTi320V-Plus-Thermal-Imager-02

UNI-T-UTi320V-Plus-Thermal-Imager-20

Power on/off
Long press the Power button for 5s to turn on the thermal imager (it needs 30 minutes warm-up time when the device is just turned on or not used for a long time, or the measurement environment changes). Long press the Power button for 3s, “Shutdown?” will show on the screen. Select “OK” to turn off the thermal imager. Long press the Power button for 8s to power off directly. When the battery is low, a low battery indicator will show on the screen, which means the thermal imager should be turned off and the battery should be charged. When the thermal imager is in low battery status for a long time, it will automatically shut down.

UNI-T UTi320V Plus Thermal Imager User Manual Featured Image: No file chosen Update Post Add MediaVisualText Paragraph P Close dialog Add media Actions Upload filesMedia Library Filter mediaFilter by type Uploaded to this post Filter by date All dates Search Media list Showing 4 of 4 media items UPLOADING 4 / 18 – UNI-T-UTi320V-Plus-Thermal-Imager-04.PNG ATTACHMENT DETAILS UNI-T-UTi320V-Plus-Thermal-Imager-03.png July 29, 2023 104 KB 294 by 203 pixels Edit Image Delete permanently Alt Text Learn how to describe the purpose of the image(opens in a new tab). Leave empty if the image is purely decorative.Title UNI-T-UTi320V-Plus-Thermal-Imager-03 Caption Description File URL: https://manuals.plus/wp-content/uploads/2023/07/UNI-T-UTi320V-Plus-Thermal-Imager-03.png Copy URL to clipboard ATTACHMENT DISPLAY SETTINGS Alignment Center Link To None Size Full Size – 294 × 203 Selected media actions 18 items selected Edit SelectionClear Insert into post No file chosenMenu Bar UNI-T UTi320V Plus Thermal Imager User Manual Featured Image: No file chosen Update Post Add MediaVisualText Paragraph P Close dialog Add media Actions Upload filesMedia Library Filter mediaFilter by type Uploaded to this post Filter by date All dates Search Media list Showing 5 of 5 media items UPLOADING 5 / 18 – UNI-T-UTi320V-Plus-Thermal-Imager-05.PNG ATTACHMENT DETAILS UNI-T-UTi320V-Plus-Thermal-Imager-04.png July 29, 2023 119 KB 463 by 162 pixels Edit Image Delete permanently Alt Text Learn how to describe the purpose of the image(opens in a new tab). Leave empty if the image is purely decorative.Title UNI-T-UTi320V-Plus-Thermal-Imager-04 Caption Description File URL: https://manuals.plus/wp-content/uploads/2023/07/UNI-T-UTi320V-Plus-Thermal-Imager-04.png Copy URL to clipboard ATTACHMENT DISPLAY SETTINGS Alignment Center Link To None Size Full Size – 463 × 162 Selected media actions 18 items selected Edit SelectionClear Insert into post No file chosen

  1. Press the SET button in the main interface or tap the menu bar icon to open the main menu.
  2.  Press the Left/Right and SET buttons or tap a submenu icon to open the selected submenu.
  3.  In the submenu, press the Left/Right button or tap its icon to select an option.
  4.  Press the SET button or tap the icon to confirm and save the selection. The thermal imager returns to the main interface.

Submenu

UNI-T-UTi320V-Plus-Thermal-Imager-05

Markup Display/hide the center spot, Hi/Lo spot and the value
Image Select the thermal, digital, fusion or PIP mode or add the QR code
 

Palette

Switch between lronbow, Rainbow, Black Hot, White Hot, Red Hot, Lava, Rainbow HC
Measure Add point, line, rectangle or circle for temperature analysis
 

Isotherm

 

Switch between Auto, Ratio, Below, Above, Section or Manual

Settings System settings

PIP
After the PIP mode is enabled, users can press the Left/Right and SET buttons or tap the screen to select Move, Stretch or Mix to change the PIP position and size and to adjust the fusion ratio.

 QR Code
Users can manually input or scan the QR code. Select “Cancel” to return to the main interface. After a QR code is input or scanned, it can be saved to a classified folder. After saving, a QR code symbol will be displayed in the upper right corner of the main interface. At this time, all the photos/videos taken will be marked with this OR code and these photos/ videos will be saved to the corresponding classified folder. Enter the QR code interface again to cancel the current QR code.

UNI-T-UTi320V-Plus-Thermal-Imager-06

 Measure (On Screen Analyzer)
In the “Measure” submenu, press the Left/Right and SET buttons or tap the screen to add an analysis object (point, line, rectangle or circle), choose an object (this function can only be used if an object is added), clear or preset. UNI-T UTi320V Plus Thermal Imager User Manual Featured Image: No file chosen Update Post Add MediaVisualText Paragraph P Close dialog Add media Actions Upload filesMedia Library Filter mediaFilter by type Uploaded to this post Filter by date All dates Search Media list Showing 8 of 8 media items UPLOADING 8 / 18 – UNI-T-UTi320V-Plus-Thermal-Imager-08.PNG ATTACHMENT DETAILS UNI-T-UTi320V-Plus-Thermal-Imager-07.png July 29, 2023 63 KB 227 by 170 pixels Edit Image Delete permanently Alt Text Learn how to describe the purpose of the image(opens in a new tab). Leave empty if the image is purely decorative.Title UNI-T-UTi320V-Plus-Thermal-Imager-07 Caption Description File URL: https://manuals.plus/wp-content/uploads/2023/07/UNI-T-UTi320V-Plus-Thermal-Imager-07.png Copy URL to clipboard ATTACHMENT DISPLAY SETTINGS Alignment Center Link To None Size Full Size – 227 × 170 Selected media actions 18 items selected Edit SelectionClear Insert into post No file chosen

After adding an analysis object, a submenu will appear. The optional functions in the submenu are choose, move, stretch (this function cannot be applied to point objects), difference (point objects can only be compared with point objects; the comparison information will be displayed on the right side), delete (delete the selected object). The temperature information of the added object will be displayed on the left. When a line object is selected, its temperature change graph will be displayed in the lower left comer.

UNI-T-UTi320V-Plus-Thermal-Imager-08

When the “Clear” function is enabled, all the added analysis objects will be cleared. When the “Preset” function is enabled, a prompt “Save tool” will pop up. Select “OK” to save the current object. The preset tool can be used directly next time. If there is no analysis object in the main interface, enable the “Preset” function, and a prompt “Read tool” will pop up. Select “OK”, and the preset tool saved last time will be added to the main interface.

UNI-T UTi320V Plus Thermal Imager User Manual Featured Image: No file chosen Update Post Add MediaVisualText Paragraph P Close dialog Add media Actions Upload filesMedia Library Filter mediaFilter by type Uploaded to this post Filter by date All dates Search Media list Showing 10 of 10 media items UPLOADING 10 / 18 – UNI-T-UTi320V-Plus-Thermal-Imager-10.PNG ATTACHMENT DETAILS UNI-T-UTi320V-Plus-Thermal-Imager-09.png July 29, 2023 111 KB 435 by 160 pixels Edit Image Delete permanently Alt Text Learn how to describe the purpose of the image(opens in a new tab). Leave empty if the image is purely decorative.Title UNI-T-UTi320V-Plus-Thermal-Imager-09 Caption Description File URL: https://manuals.plus/wp-content/uploads/2023/07/UNI-T-UTi320V-Plus-Thermal-Imager-09.png Copy URL to clipboard ATTACHMENT DISPLAY SETTINGS Alignment Center Link To None Size Full Size – 435 × 160 Selected media actions 18 items selected Edit SelectionClear Insert into post No file chosen

Note
The maximum number of point objects that can be added is 5 (line: 1; rectangle: 3; circle: 3). The total number of objects added cannot exceed 6. When it exceeds the specified number, a prompt “XX outnumber” will pop up.

Image Browsing and Editing
In the main interface, press the Image browsing button to enter the multimedia browsing interface. Press the Up/Down and SET buttons or tap the screen to open All photos/videos or other folders. Press the direction and SET buttons or tap to browse a photo or video. Press the Left/Right button or slide the screen to switch between photos/videos.

UNI-T UTi320V Plus Thermal Imager User Manual Featured Image: No file chosen Update Post Add MediaVisualText Paragraph P Close dialog Add media Actions Upload filesMedia Library Filter mediaFilter by type Uploaded to this post Filter by date All dates Search Media list Showing 11 of 11 media items UPLOADING 11 / 18 – UNI-T-UTi320V-Plus-Thermal-Imager-11.PNG ATTACHMENT DETAILS UNI-T-UTi320V-Plus-Thermal-Imager-10.png July 29, 2023 96 KB 258 by 196 pixels Edit Image Delete permanently Alt Text Learn how to describe the purpose of the image(opens in a new tab). Leave empty if the image is purely decorative.Title UNI-T-UTi320V-Plus-Thermal-Imager-10 Caption Description File URL: https://manuals.plus/wp-content/uploads/2023/07/UNI-T-UTi320V-Plus-Thermal-Imager-10.png Copy URL to clipboard ATTACHMENT DISPLAY SETTINGS Alignment Center Link To None Size Full Size – 258 × 196 Selected media actions 18 items selected Edit SelectionClear Insert into post No file chosen

When browsing a photo or video:

  1. Press the SET button or tap the screen to open the submenu.
  2. Press the Left/Right and SET buttons or tap to select Info/Notes/Edit/QR code/ Delete.

UNI-T-UTi320V-Plus-Thermal-Imager-11

 

Info

Create date, modified date, emissivity, HVGA (infrared resolution), QR code (the classified folder where the photo/video is saved}, distance (photos only}, notes (text/voice)
Notes Add text and voice notes to photos/videos (displayed in Info)
 

Edit (photos only)

Perform Markup/Image/ Palette/Measure/ Isotherm/Graffiti function on photos
Play (videos only} Play or pause videos
QR code Add QR code to classify photos/videos
Delete Delete the current photo/video

Edit
After editing a photo, press the direction and SET buttons or tap to restore the photo to its initial state (graffiti cannot be cleared in this way).

UNI-T-UTi320V-Plus-Thermal-Imager-12

Press the Return button after editing a photo, and a prompt “Exit?” will pop up. Select “Exit” to exit the editing interface. Select “Save” and a prompt “Cover?” will pop up. Select “Cover”, the original photo will be changed and saved. Select “New”, the original photo will not be changed and a new photo will be saved.

QR Code
When the QR code function is enabled, users can add existing QR code to classify photos/videos, delete the QR code of photos/videos or add a new QR code. QR codes added here are temporary and will not be saved to the existing QR code classified folders. The classified folders can only be modified in the Settings.

Digital Zoom
In the main interface, press the Up button to zoom in the screen. The current magnification is displayed in the upper right comer of the screen. The magnification steps through 1X, 2X, 4X and 1X.

Settings
After entering the Settings interface, press the Up/Down and SET buttons or tap the screen to select a setting item.

UNI-T UTi320V Plus Thermal Imager User Manual Featured Image: No file chosen Update Post Add MediaVisualText Paragraph P Close dialog Add media Actions Upload filesMedia Library Filter mediaFilter by type Uploaded to this post Filter by date All dates Search Media list Showing 14 of 14 media items UPLOADING 14 / 18 – UNI-T-UTi320V-Plus-Thermal-Imager-14.PNG ATTACHMENT DETAILS UNI-T-UTi320V-Plus-Thermal-Imager-13.png July 29, 2023 17 KB 225 by 175 pixels Edit Image Delete permanently Alt Text Learn how to describe the purpose of the image(opens in a new tab). Leave empty if the image is purely decorative.Title UNI-T-UTi320V-Plus-Thermal-Imager-13 Caption Description File URL: https://manuals.plus/wp-content/uploads/2023/07/UNI-T-UTi320V-Plus-Thermal-Imager-13.png Copy URL to clipboard ATTACHMENT DISPLAY SETTINGS Alignment Center Link To None Size Full Size – 225 × 175 Selected media actions 18 items selected Edit SelectionClear Insert into post No file chosen

Camera mode Single show VIDEO /Time-lapse (10s-1000s)
Units Temperature: ·c, K, “F; Distance: m, ft
Parameter Adjust the emissivity (refer to the emissivity table) and object distance (manual/auto)
Hi/Lo alert Hi/Lo/LED/audible alert
QR code Change the name of classified folders and reset OR codes
Language Switch between English/Chinese
Date & Time Modify time-format/date/time
Wi-Fi Turn on/off the hotspot, modify hotspot information when it is on
USB mode USB storage/USS projection
Brightness Adjust the brightness (1-100)
Volume Adjust the volume (1-100)
Laser distance measure Laser distance measure mode: single/continue measurement
Shutdown

(auto power off)

Off/5 min/10 min/20 min/30 min/45 min/60 min/90 min
Factory reset Restore the factory settings
Format Format the SD Card
 

About

Display product model, HVGA (infrared resolution), SWV (software version), HWV {hardware version), SYSV (system version), SD card capacity

Hi/Lo alert
After entering the settings interface, press the Up/Down and SET buttons or tap the screen to select “Hi/Lo alert”. In the submenu, users can select Hi/Lo/LED/audible alert. When Hi/ Lo alert is enabled, press the Up/Down and SET buttons or slide the screen to adjust the Hi/Lo value. When the measured temperature exceeds the Hi value, a red triangle will pop up in the main interface. When the measured temperature is lower than the Lo value, a green inverted triangle will pop up. (If the LED alert is enabled, the alerts will be accompanied by flashing lights. If the audible alert is enabled, a sound will be emitted.)

UNI-T-UTi320V-Plus-Thermal-Imager-14

Wi-Fi
After entering the settings interface, press the Up/Down and SET buttons or tap the screen to select “Wi-Fi”. Press the SET button or tap the screen to turn on the Wi-Fi Hotspot. Press the Up/Down and SET buttons or tap to change the AP bands, ID or password.

Laser Distance Measure
In the main interface, press the “Laser distance measure” button to take measurements. If “Single” is selected in the settings interface, press and hold the “Laser distance measure” button until the distance value appears. Release the button to exit. If “Continue” is selected in the settings interface, long press the “Laser distance measure” button until the distance value appears. Release the button and move the thermal imager to take continuous measurements. Press the button again to exit the measurement.

SD Card
The device can be inserted into a Micro SD card to store images. To avoid affecting the device operating speed, please copy the backup data regularly and clean up the SD card in time. Do not insert or remove the SD card repeatedly; otherwise the data in it may be abnormal. If the SD card is removed when users are viewing or editing images, a prompt “SD lost” will pop up. UNI-T-UTi320V-Plus-Thermal-Imager-15

Maintenance
Use a wet cloth or weak soap solution to clean the outer housing of the device. Do not use abradant, isopropyl alcohol or solvents to clean the housing or lens.

Notes
This device complies with Part 15 of the FCC Rules.

Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received .including interference that may cause undesired operation.
    Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Product label UNI-T-UTi320V-Plus-Thermal-Imager-16

Emissivity Table

Material Emissivity Material Emissivity
Wood 0.85 Black paper 0.86
Water 0.96 Polycarbonate 0.8
Brick 0.75 Concrete 0.97
Stainless steel 0.14 Copper oxide 0.78
Tape 0.96 Cast iron 0.81
Aluminum plate 0.09 Rust 0.8
Copper plate 0.06 Gypsum 0.75
Black aluminum 0.95 Oil paint 0.9
Human skin 0.98 Rubber 0.95
Asphalt 0.96 Soil 0.93
PVC plastic 0.93

The contents of this manual are subject to change without notice.

UNl-“‘I’:UNI-TRENDTECHNDLDGV (CHINA) CD.,LTD.
No. 6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial
Development Zone, Dongguan City, Guangdong Province, China