UT-PA2000 Active Single Ended Probe
“
Specifications:
- Product Name: UT-PA2000/1000 Active single-ended probe
- Model: UT-PA2000UT-PA1000
- Document Version: UT-PA2000/1000-V2.0
- Manufacturer: UNI-TREND TECHNOLOGY(CHINA) CO., LTD.
Product Usage Instructions:
Foreword
Thank you for choosing the UNI-T instrument. To ensure safe and
proper use of this instrument, please read the manual carefully,
especially the safety instructions section. Keep the manual in a
convenient location for future reference.
Safety Instructions
This section contains essential information and warnings that
must be followed to operate the instrument safely. Always operate
the instrument under safe conditions and adhere to accepted safety
procedures.
Safety Precautions
Warning: Follow safety guidelines to prevent
electric shock and personal safety risks. Only professional users
and responsible organizations should use this device for
measurement purposes. Indoor use is recommended unless otherwise
specified in the manual.
Safety Signs:
- Warning: Indicates a hazard that may result in
personal injury or death. Follow all instructions carefully. - Caution: Indicates a hazard that may cause
product damage or data loss. Pay attention to all
instructions.
FAQ (Frequently Asked Questions):
Q: Can this probe be used with any oscilloscope?
A: The UT-PA2000/1000 Active single-ended probe
is designed for use with compatible devices. Ensure compatibility
with your oscilloscope before use.
Q: Is it safe to use this probe for high-voltage
measurements?
A: For safety reasons, avoid using this probe
for high-voltage measurements beyond its specified range. Refer to
the manual for voltage limitations.
“`
UT-PA2000/1000 Active single-ended probe
2GHz | 175ps | 10:1 | ± 4V | 1.3pF
User Manual REV.2.0
April 2025
UT-PA2000UT-PA1000 Active single-ended probe
Copyright Information
All rights reserved by UNI-Trend Technology (China) Co., Ltd. If the original purchaser sells or transfers the product to a third party within three years from the date of purchase, the warranty period shall be three years from the date the original purchaser purchased the product from UNI-T or an authorized Uni-T distributor. Probes and other accessories and fuses are not covered by this warranty. If a defect in the product is proven during the applicable warranty period, UNI-T may, at its sole discretion, either repair the defective product without charge for parts and labor or replace the defective product with an equivalent product (as determined by UNI-T). Parts, modules and replacement products used by Uni-T for warranty purposes may be new or repaired to have performance equivalent to new products. All replaced parts, modules and products shall become the property of UNI-T. The “customer” referred to below means the individual or entity claiming the rights stipulated in this warranty. To obtain the services promised under this warranty, the “customer” must notify UNI-T of the defect within the applicable warranty period and make appropriate arrangements for the performance of the service. The customer is responsible for packing the defective product and shipping it to the repair center designated by UNI-T, and prepaying the shipping cost and providing a copy of the original purchaser’s proof of purchase. If the product is to be returned to a location within the country where the UNI-T repair center is located, UNI-T shall bear the cost of returning the product to the customer. If the product is returned to any other location, the customer shall be responsible for all shipping costs, duties, taxes and any other expenses. This warranty does not apply to any defect, malfunction or damage caused by accident, normal wear and tear of machine parts, use or improper use outside the scope specified in the product, or improper or inadequate maintenance. UNI-T is under no obligation under the terms of this warranty to provide the following services:
a) Repair damage caused by installation, repair or maintenance of the product by a person other than UNI-T service representative;
b) repair damage caused by improper use or connection with incompatible devices c) repair any damage or malfunction caused by the use of a power supply that does not
meet the requirements of this manual; d) Repair products that have been altered or integrated with other products (if this
alteration or integration would increase the time or difficulty of repairing the product). This warranty is made by UNI-T for this product and is used in lieu of any other express or implied warranties that UNI-T and its distributors disclaim Make any implied warranties of merchantability or fitness for a particular purpose. In the event of a breach of this warranty, NUIT’s responsibility to repair or replace the defective product is the sole and exclusive remedy available to the customer. In no event shall UNI-T and its distributors be liable for any indirect, special, incidental or consequential damages, whether or not they have been advised of the possibility of such damages.
www.instruments.uni-trend.com
2
Trademark Information
UT-PA2000UT-PA1000 Active single-ended probe
is UNI-TREND TECHNOLOGY(CHINA) CO., LTD. Registered trademarks.
Document version
UT-PA2000/1000-V2.0
Statement
UNI-T products are protected by patents in China or other countries, including patents obtained or pending.
The Company reserves the right to change product specifications and prices. All rights reserved. The Licensed Software Products are owned by UNI-T and its subsidiaries
or suppliers and are protected by national copyright laws and international treaty provisions. The information in this article supersedes the information in all previously published materials. Technical data are subject to change without notice.
Foreword
Thank you for choosing this UNI-T instrument. For safe and proper use this instrument, please read this manual carefully, especially the safety instructions section. After reading this manual, it is recommended to keep the manual in a convenient location, preferably near the device, for future reference.
Safety Instructions
This chapter contains information and warnings that must be observed. Ensure that the
instrument is operated under the safe conditions. In addition to the safety precautions indicated
in this chapter, you must also follow accepted safety procedures.
Safety Precautions
Warning
Please follow these guidelines to avoid possible electric shock and risk to personal safety.
Users must adhere to the following conventional safety precautions in operation, service, and maintenance of this device. UNI-T will not
www.instruments.uni-trend.com
3
Safety Statements Warning
Caution Note
Safety Signs
UT-PA2000UT-PA1000 Active single-ended probe
be liable for any personal safety and property loss caused by the user’s failure following the safety precautions. This device is designed for professional users and responsible organizations for measurement purposes. Do not use this device in any manner not specified by the manufacturer. This device is intended for indoor use only, unless otherwise stated in the product manual.
“Warning” indicates the presence of a hazard. It warns users to pay attention to a certain operation process, operation method or similar. Personal injury or death may occur if the rules in the “Warning” statement are not properly executed or observed. Do not proceed to the next step until you fully understand and meet the conditions stated in the “Warning” statement.
“Caution” indicates the presence of a hazard. It warns users to pay attention to a certain operation process, operation method or similar. Product damage or loss of important data may occur if the rules in the “Caution” statement are not properly executed or observed. Do not proceed to the next step until you fully understand and meet the conditions stated in the “Caution” statement.
“Note” indicates important information. It reminds users to pay attention to procedures, methods, and conditions, etc. The contents of “Note” should be highlighted if necessary.
Danger Warning Caution
Note
It indicates danger of electric shock, which may cause personal injury or death.
It indicates that there are factors you should be cautious of to prevent personal injury or product damage.
It indicates danger, which may cause damage to this device or other equipment if you fail to follow a certain procedure or condition. If the “Caution” sign is present, all conditions must be met before you proceed to operation.
It indicates potential problems, which may cause failure of this device if you fail to follow a certain procedure or condition. If the “Note” sign is present,
www.instruments.uni-trend.com
4
UT-PA2000UT-PA1000 Active single-ended probe
all conditions must be met before this device will function properly.
Certification CE indicates a registered trademark of EU.
Waste
Do not place equipment and accessories in the trash. Items must be properly disposed of in accordance with local regulations.
EEUP
This environment-friendly use period (EFUP) mark indicates that dangerous or toxic substances will not leak or cause damage within this indicated time period. The environmentally friendly use period of this product is 40 years, during which it can be used safely. Upon expiration of this period, it should enter the recycling system.
Safety Requirements
Warning
Static electricity can cause damage to the instrument and should be tested in an anti-static zone whenever possible. Before connecting the cable to the instrument, its inner and outer conductors should Anti-static protection be briefly grounded to release static electricity. This equipment has a protection level of 4kV in contact discharge and 8kV in air discharge.
This device is intended for indoor use in a clean and dry Working environment environment with an ambient temperature range of 0°C – 40°C. The
appliance must not be operated in explosive, dusty, or humid air.
Do not operate in a humid environment
Avoid the risk of short circuits or electric shock in the internal circuits of the instrument, and do not operate the instrument in a humid environment.
Do not operate in a flammable or explosive environment
To avoid damage to the instrument or personal injury, do not operate the instrument in a flammable or explosive environment.
Caution
Abnormality
If this device may be faulty, please contact the authorized maintenance personnel of UNI-T for testing. Any maintenance, adjustment or parts replacement must be done by the relevant personnel of UNI-T.
handling safety
In order to avoid the instrument slipping down during handling, resulting in damage to the buttons, interfaces and other components on the instrument, please pay attention to the safety of handling.
www.instruments.uni-trend.com
5
Maintain proper ventilation
Keep clean and dry Note
Calibration
UT-PA2000UT-PA1000 Active single-ended probe
Poor ventilation can cause the temperature of the instrument to rise, which may further lead to damage to the instrument. Good ventilation should be maintained during use. Avoid dust or moisture in the air affecting the performance of the instrument, and keep the surface of the product clean and dry.
The recommended calibration period is one year. Calibration should only be conducted by qualified personnel.
www.instruments.uni-trend.com
6
UT-PA2000 Overview
UT-PA2000UT-PA1000 Active single-ended probe
The UT-PA2000 and UT-PA1000 are active single-ended probes designed for high-frequency measurements, incorporating many of the features required for today’s general-purpose highspeed probes. Active single-ended probes are widely used in high-speed digital circuits, bus analysis, signal integrity analysis and many other high-speed fields, which can obtain signal information in the circuit more accurately and quickly, which helps to improve the work efficiency and accuracy of engineers. Unless otherwise noted, the illustrations used in this manual are MSO7000X-series oscilloscopes and UT-PA2000 probes.
Excellent
Electrical properties: High bandwidth – Accurately measure high-speed serial
signals UT-PA2000 bandwidth: 2GHz UT-PA1000 bandwidth: 1GHz Extremely high signal fidelity UT-PA2000 rise time: 175ps UT-PA1000 rise time: 350ps Low load: 1M input impedance, 1.3pF input capacitance Dynamic range: ±4V Bias range: ±4V
Compatibility
Oscilloscopes MSO7000XMSO8000HDUPO7000L MSO5000HDMSO3000HDMSO3000X
Accessibility
Probe functions:
Probe front light on/off button Control the oscilloscope to run/stop Clear the currently displayed waveforms and
measurement values on the oscilloscope Control the oscilloscope to perform a forced
trigger
Outstanding
Machine design: A compact probe head used for testing small circuit
components Various accessories for flexible connection to the DUT
(Device Under Test) A special probe headlight design
www.instruments.uni-trend.com
7
Quick Start Guide
UT-PA2000UT-PA1000 Active single-ended probe
General Inspection
Before you use a new active single-ended probe, it is recommended that you check the probe as follows. 1. Check whether there is any damage caused by transportation
If you notice that the carton or styrofoam protector is severely damaged, please contact your UNI-T distributor. 2. Check the attachments Please check the random accessories according to the packing list, if there is damage or missing, if the accessories are missing or damaged, please contact your UNI-T dealership. 3. Check the whole machine If you notice that the probe is cosmetially damaged, not working properly, or failing performance testing, please contact your UNI-T dealer. If the instrument is damaged due to shipping, please keep the packaging and notify the shipping department and contact your UNI-T distributor.
Probe Dimensions
www.instruments.uni-trend.com
8
Supplied Accessories
UT-PA2000UT-PA1000 Active single-ended probe
This section lists the UT-PA2000 and UT-PA1000 probe kits and standard accessories. Parts listed can be ordered through consultation with UNI-T and distributors.
Accessory
Gold-plated aircraft hook (Red) Gold-plated aircraft hook (Black) Offset blade Ground blade Ground flexible tip Rigid tip Flexible tip Two-wire socket adapter (9cm) Straight-through grounding wire (5cm) Straight-through grounding wire (5cm) Single-conductor copper foil sheet (with adhesive backing), 2*2cm Tip box Accessory box Ceramic tweezers Identification ring
Quantity
×2 ×2 ×1 ×5 ×2 ×20 ×2 ×1 ×2 ×2
×10
×1 ×1 ×1 ×8
Description
Optional UT-PA-F01, bandwidth of 1GHz Standard UT-PA-F01, bandwidth of 1GHz Optional UT-PA-F02, bandwidth of 1GHz Standard UT-PA-F03, bandwidth of 1GHz Standard UT-PA-F04, bandwidth of 1GHz Standard UT-PA-F05, bandwidth of 2GHz Optional UT-PA-F06, bandwidth of 1GHz Optional UT-PA-F07, bandwidth of 1GHz Standard UT-PA-F08, bandwidth of 1GHz Standard UT-PA-F09, bandwidth of 1GHz Optional UT-PA-F10, bandwidth of 1GHz
Standard UT-PF01 Standard UT-PF02 Standard PT05-003 Standard UT-PF03
www.instruments.uni-trend.com
9
Probe
UT-PA2000UT-PA1000 Active single-ended probe
The rear end of the probe can be connected to MSO7000X, MSO8000HD, UPO7000L and other series of oscilloscopes, and the probe can be powered through the oscilloscope channel. The front end can be flexibly inserted into the measured point according to the user’s needs.
Probe Front-end
The front end of the probe adopts a fixed pitch single-ended grounding pin, the front probe lamp design, and the front oscilloscope control button design makes it easy to control the oscilloscope during measurement.
Front View Side View 2
www.instruments.uni-trend.com
Side View 1
10
Using Probe
UT-PA2000UT-PA1000 Active single-ended probe
When using a probe, the correct use of the probe can ensure probe performance, extend the life of the probe and guarantee the validity of the signal measurement results.
Connect the oscilloscope Use of the front end of the hand-held single-ended probe Replace the probe accessory Use the probe button Calibrate the probe
Connecting the oscilloscope
After the probe is properly connected to the UNI-T MSO7000X, UPO7000L, MSO8000HD, etc., the oscilloscope automatically recognizes the probe and provides power to the probe through the oscilloscope channel. In this case, you can adjust the offset voltage and calibrate the probe through the oscilloscope front panel menu (the MSO7000X-series oscilloscope is used as an example below). 1 Connect one end of the active probe to the oscilloscope channel input connector and push
to the closed position.
www.instruments.uni-trend.com
11
UT-PA2000UT-PA1000 Active single-ended probe
2 When you need to disconnect the probe from the oscilloscope, first push the probe’s locking knuckle in reverse to the slack position, unplug the connector from the oscilloscope, and release the latch
Note: Do not rotate the probe on oscilloscope’s BNC connector; otherwise, the probe may be damaged. 3 Probe recognition
Once the probe is inserted, the oscilloscope will automatically recognize the probe information, including the manufacturer, model, serial number, probe magnification, and more. You can click on the oscilloscope vertical channel and click input in the vertical channel control menu to view it.
4 Automatically adjust probe multiple The probe is fixed at 10X, and when the probe is connected to an oscilloscope, the oscilloscope’s probe magnification will be fixed at 10X and cannot be changed.
5 Automatically set impedance
www.instruments.uni-trend.com
12
UT-PA2000UT-PA1000 Active single-ended probe
The probe has a fixed output impedance of 50, and when the probe is connected to an oscilloscope, the oscilloscope’s impedance setting is fixed at 50 and cannot be changed.
Using the front-end of the handheld single-ended probe
The UT-PA2000 probe has an effective bandwidth of up to 2GHz on the front end and the UTPA1000 probe has an effective bandwidth of up to 1GHz on the front end, and the probe tip and ground pin can be replaced and can be used with a variety of flexible accessories to extend probe life. Using the front end of the handheld single-ended probe, the users can conveniently measure single-ended signals. When performing signal measurement, the single-ended ground pin needs to be grounded.
Probe Tip and Ground Tip Connect to DUT Note: Due to the fixed spacing of the probe tip, ensure the ground connection is made as close as possible to the probe tip.
Use probe accessories
The probe is available with a variety of test accessories for different scenarios, and when using these accessories, it is necessary to replace the standard probe pin or the ground pin. 1. Replace the probe tip
Carefully replace the probe tip, handle the replacement process cautiously to avoid damaging the connection and compromising the probe’s performance. Replacement Method Disconnect the active probe from the oscilloscope. Insert the new probe tip vertically into the active probe.
www.instruments.uni-trend.com
13
2. Replace single-ended ground sheet
UT-PA2000UT-PA1000 Active single-ended probe
When replacing the single-ended ground sheet, ensure that it is securely connected to the
copper pipe to maintain the probe’s performance.
The accessories for the test are as follows: The test connection diagrams illustrate the configurations of specific probe accessories and the probe’s front end.
Right-angle Ground Wire
Ground Spring Tip
Grounding knife
Using probe buttons
The front end of the probe is designed with buttons for the control of the oscilloscope and the probe headlamp, and the use of the probe button during the test can effectively improve the testing efficiency of the tester. The probe control buttons contain functions such as probe headlight control, oscilloscope run/stop, clear display, forced trigger, no operation, etc., and can be used when the UT-PA2000 and UT-PA1000 are used with MSO7000X, UPO7000L, MSO8000HD, and other series of oscilloscopes.
www.instruments.uni-trend.com
14
Control button
UT-PA2000UT-PA1000 Active single-ended probe
Probe Headlight Control When the probe is connected to the oscilloscope, click the oscilloscope vertical channel setting, and select the headlight in the input settings – > probe button option, then the probe button can be set to turn on/off the headlight function, in the test scene of low light, the probe headlamp can provide you with a light source to ensure an effective connection between your probe and the test specimen
.
The following is the test chart of the probe headlight control, when the headlight is on, press the probe button to turn the headlight off. When the headlight is off, press the probe button to turn the headlight on
www.instruments.uni-trend.com
15
UT-PA2000UT-PA1000 Active single-ended probe
Run/Stop When the probe is connected to the oscilloscope, click the oscilloscope vertical channel settings, and select Run/Stop in the Input Settings – > Probe button options, you can set the probe button to control the oscilloscope run/stop function, during the test, you can free one hand to stop and start the oscilloscope in time when the key signal is captured. When the oscilloscope is running, press the probe button to stop it. When the oscilloscope is stopped, press the probe button to run it. Clear Display When the probe is connected to the oscilloscope, click the oscilloscope vertical channel setting, and select Clear Display in the Input Settings – > Probe button option, you can set the probe button to control the oscilloscope clear display function, during the test, you can control the oscilloscope to clear the measured value, refresh the acquisition trace, etc. Forced Trigger When the probe is connected to the oscilloscope, click the oscilloscope vertical channel setting, and select the forced trigger in the input settings-> probe button option, you can set the probe button to control the oscilloscope forced trigger function No operation When the probe is connected to the oscilloscope, click the oscilloscope vertical channel settings, and select No operation in the Input Settings -> Probe button option, you can set the probe button to no operation, and the probe button will have no effect.
www.instruments.uni-trend.com
16
Calibrating the probe
UT-PA2000UT-PA1000 Active single-ended probe
Before using the probe, you need to calibrate the probe, and the probe calibration will effectively adjust the zero offset of the probe, which will ensure the integrity of the measured signal. 1. Connecting the oscilloscope
Refer to the first section Connecting the oscilloscope . After completing the connection, the probe needs to be warmed up for 15 minutes to ensure that the probe enters a stable working state. 2. Access the oscilloscope’s channel menu and click Input Settings > Auto Calibration to perform the probe calibration.
3. Before calibration, you need to make sure that the probe is not connected to any DUT, insert the probe into the oscilloscope channel, connect the probe to the square wave terminal, and then click Auto-Calibration.
www.instruments.uni-trend.com
17
UT-PA2000UT-PA1000 Active single-ended probe
4. Wait for the calibration to be completed. The calibration time depends on the degree of zero offset of the probe, approximately 40 seconds. If this is the first time calibrating the probe, the process may take longer. When calibration is complete, the oscilloscope will display either “Probe Calibration Completed” or “Probe Calibration Failed” based on the results. If the prompt displays “Probe Calibration Failed,” please retry the calibration steps. If calibration fails multiple times, contact UNI-T distributor for assistance.
www.instruments.uni-trend.com
18
UT-PA2000UT-PA1000 Active single-ended probe
Appendix A Maintenance and Cleaning
(1) General Maintenance Keep the probe and its accessories away from the direct sunlight. CautionAvoid contact with sprays, liquids, or solvents to prevent probe damage.
(2) Cleaning Check the probe frequently according to the operating condition. Follow these steps to clean the external surface of the probe: Use a soft cloth to remove dust from the probe. Disconnect the power supply and clean the probe with mild detergent or water. Do not use abrasive or chemical cleaners, as they may damage the probe. WarningPlease confirm that the instrument is completely dry before use, to avoid electrical shorts or even personal injury caused by moisture.
www.instruments.uni-trend.com
19
UT-PA2000UT-PA1000 Active single-ended probe
Appendix B Technical Specifications
Technical Specifications
UT-PA2000
UT-PA1000
Bandwidth (-3dB) Rise Time DC Attenuation Ratio Input Dynamic Range Maximum Input Voltage Input Offset Range DC Offset ErrorOutput is 0 Input Capacitance Input Resistance Transmission Delay
Flatness (25)
Probe Noise (Equivalent to input end) Output Impedance ESD (Electrostatic Discharge) Power Loss
2GHz
1GHz
175ps
350ps
10:1±5%
±4VDC or peak AC
±12VNon-working voltage
±4V
±2mV
1.3pF
1M ±1%
7ns
Typical 0.5dB(100kHz – 500MHz)
Typical 1dB(500MHz – 1GHz)
<7mV ACrms
50
8kV HBM
0.5W
General Specifications
Weight Wire Length
Probe Dimension
Compatible Oscilloscopes
Environmental characteristics Operating temperature Non-operating temperature Operating humidity Non-operating humidity Working altitude Non-operating altitude
<100g 1.2m front 110mmx18.3mmx20mm back end 106.6mmx24mmx27mm MSO7000X,MSO8000HD,UPO7000L,MSO3000HD, MSO3000X, MSO5000HD
040 -4070 95% RH @40 95% RH @65 4600m 15300m
www.instruments.uni-trend.com
20
UT-PA2000UT-PA1000 Active single-ended probe
Appendix C Limited Warranty and Liability
UNI-T guarantees that the Instrument product is free from any defect in material and workmanship within three years from the purchase date. This warranty does not apply to damages caused by accident, negligence, misuse, modification, contamination, or improper handling. If you need a warranty service within the warranty period, please contact your seller directly. UNI-T will not be responsible for any special, indirect, incidental, or subsequent damage or loss caused by using this device. For the probes and accessories, the warranty period is one year. Visit instrument.uni-trend.com for full warranty information.
Learn more at: www.uni-trend.com
Register your product to confirm your ownership. You will also get product notifications, update alerts, exclusive offers and all the latest information you need to know.
www.instruments.uni-trend.com
21
Appendix D Statement and Contact Us
is the licensed trademark of UNI-TREND TECHNOLOGY (CHINA) CO., Ltd. UNI-T products are protected under patent laws in China and internationally, covering both granted and pending patents. Licensed software products are the properties of UNI-Trend and its subsidiaries or suppliers, all rights reserved. This manual contains information that replaces all earlier published versions. The product information in this document subject to update without notice. For more information on UNI-T Test & Measure Instrument products, applications, or service, please contact UNI-T instrument for support, the support center is available on www.unitrend.com ->instruments.uni-trend.com
https://instruments.uni-trend.com/ContactForm/
Headquarter
UNI-TREND TECHNOLOGY (CHINA) CO., Ltd. Address: No.6, Industrial North 1st Road, Songshan Lake Park, Dongguan City, Guangdong Province, China Tel: (86-769) 8572 3888
Europe
UNI-TREND TECHNOLOGY EU GmbH Address: Affinger Str. 1286167 Augsburg Germany Tel: +49 (0) 821 8879980
North America
Uni-Trend TECHNOLOGY US INC. Address: 3171 Mercer Ave STE 104, Bellingham, WA 98225 Tel: +1-888-668-8648
Copyright © 2024 by UNI-Trend Technology (China) Co., Ltd. All rights reserved.
PN110401113361X
1
2
3
4
5
6
7
DWH
CHK
APPRO
:148×210±1mm. 128G 60g ,…
REV.0 MODEL UT-PA2000/1000 Part NO. 110401113361X
() UNI-TREND TECHNOLOGY (CHINA) CO.,LTD
Documents / Resources
![]() |
UNI-T UT-PA2000 Active Single Ended Probe [pdf] User Manual UT-PA2000, UT-PA2000 Active Single Ended Probe, Active Single Ended Probe, Single Ended Probe |