UNI-T UPO1102 Digital Phosphor Oscilloscope
Product Specifications
- Model: UPO1000 Series
- Manufacturer: Uni-Trend Technology (China) Co., Ltd.
- File Version: 20230822-V1.00.0018
- Power Supply: AC
- Certifications: CE, UKCA, UL STD 61010-1, CSA STD C22.2 No.61010-1
Product Usage Instructions
Safety Requirements
This section contains important safety information to ensure the safe operation of the instrument:
- Follow all safety precautions provided by the manufacturer.
- Only use the device indoors unless specified otherwise.
- Check the region’s voltage range for AC and DC operations.
- Properly ground the frame and chassis of the instrument.
Preparation Before Use
Before using the UPO1000 Series Digital Phosphor Oscilloscope, follow these steps:
- Check all terminal-rated values to ensure compatibility.
- Use the power cord provided with the device.
- Properly ground the instrument to prevent electrical hazards.
- Ensure the AC power supply meets the rated voltage of the device.
- Avoid operating the device in humid, flammable, or explosive environments.
Using the Device
When using the UPO1000 Series Oscilloscope, keep these guidelines in mind:
- Utilize measurement accessories correctly with the input/output ports.
- Avoid disassembly and cleaning unless necessary for maintenance.
- Do not use the device to measure main circuits to prevent damage.
Frequently Asked Questions
- Q: Can I use the UPO1000 Series Oscilloscope outdoors?
- A: No, this device is designed for indoor use only unless specified otherwise in the product manual.
- Q: What should I do if I encounter a safety warning while using the oscilloscope?
- A: Stop operation immediately and refer to the safety requirements section of the manual for guidance on addressing warnings.
- Q: How often should I check the power cord and grounding of the instrument?
- A: It is recommended to inspect the power cord and grounding regularly to ensure safe operation of the oscilloscope.
Safety Requirements
This section contains information and warnings that must be followed to keep the instrument operating under safety conditions. In addition, users should also follow the common safety procedures.
Safety Precautions | |
Warning | Please follow the following guidelines to avoid possible electric shock and risk to personal safety. |
Users must follow the following conventional safety precautions in the operation, service, and maintenance of this device. UNI-T will not be liable for any personal safety and property loss caused by the user’s failure to follow the following safety precautions. This device is designed for professional users and responsible organizations for measurement purposes. Do not use this device in any way not specified by the manufacturer. This device is only for indoor use unless otherwise specified in the product manual. | |
Safety Statement | |
Warning | “Warning” indicates the presence of a hazard. It reminds users to pay attention to a certain operation process, operation method, or similar. Personal injury or death may occur if the rules in the “Warning” statement are not properly executed or observed. Do not proceed to the next step until you fully understand and meet the conditions stated in the “Warning” statement. |
Caution | “Caution” indicates the presence of a hazard. It reminds users to pay attention to a certain operation process, operation method, or similar. Product damage or loss of important data may occur if the rules in the “Caution” statement are not properly executed or observed. Do not proceed to the next step until you fully understand and meet the conditions stated in the “Caution” statement. |
Note | “Note” indicates important information. It reminds users to pay attention to procedures, methods conditions, etc. The contents of the “Note” should be highlighted if necessary. |
Safety Sign
Safety Requirements
Warning
Preparation before use | Please connect this device to the AC power supply with the power cable provided; The AC input voltage of the line reaches the rated value of this device. See the product manual for specific rated values.
The line voltage switch of this device matches the line voltage; The line voltage of the line fuse of this device is correct; Not used to measure the main circuit. |
Check all terminal-rated values | Please check all rated values and marking instructions on the product to avoid fire and the impact of excessive current. Please consult the product manual for detailed rated values before connection. |
Use the power cord properly | You can only use the special power cord for the instrument approved by the local and state standards. Please check whether the insulation layer of the cord is damaged or the cord is exposed, and test whether the cord is conductive. If the cord is damaged, please replace it before using the instrument. |
Instrument Grounding | To avoid electric shock, the grounding conductor must be connected to the ground. This product is grounded through the grounding conductor of the power supply.
Please be sure to ground this product before it is powered on. |
AC power supply | Please use the AC power supply specified for this device. Please use the power cord approved by your country and confirm that the insulation layer is not damaged. |
Electrostatic prevention | This device may be damaged by static electricity, so it should be tested in the
anti-static area if possible. Before the power cable is connected to this device, the internal and external conductors should be grounded briefly to release static electricity. The protection grade of this device is 4KV for contact discharge and 8KV for air discharge. |
Measurement accessories | Measurement accessories are of the lower class and do not apply to main power supply measurement, CAT II, CAT III, or CAT IV circuit measurement.
Probe assemblies and accessories within the scope of IEC 61010-031 and current sensors within the scope of IEC 61010-2-032 shall meet their requirements. |
Use the input/output port of this device properly | Please use the input/output ports correctly provided by this device. Do not load any input signal at the output port of this device. Do not load any signal that does not reach the rated value at the input port of this device. The probe or other connection accessories should be effectively grounded to avoid product damage or abnormal function. Please refer to the product manual for the rated value of the input/output port of this device. |
Power fuse | Please use the power fuse of the specified specification. If the fuse needs to be replaced, it must be replaced with another one that meets the specified specifications by the maintenance personnel authorized by UNI-T. |
Disassembly and cleaning | There are no components available to operators inside. Do not remove the protective cover.
Maintenance must be carried out by qualified personnel. |
Service environment | This device should be used indoors in a clean and dry environment with ambient temperature from 0 ℃ – 40 ℃.
Do not use this device in explosive, dusty, or humid air. |
Do not operate in a humid environment | Do not use this device in a humid environment to avoid the risk of internal short circuits or electric shock. |
Do not operate in a flammable and explosive environment | Do not use this device in a flammable and explosive environment to avoid product damage or personal injury. |
Caution |
Abnormality | If this device may be faulty, please contact the authorized maintenance personnel of UNI-T for testing. Any maintenance, adjustment, or parts replacement must be done by the relevant personnel of UNI-T. |
Cooling | Do not block the ventilation holes at the side and back of this device;
Do not allow any external objects to enter this device via ventilation holes; Please ensure adequate ventilation, and leave a gap of at least 15 cm on both sides, front and back of this device. |
Safe transportation | Please transport this device safely to prevent it from sliding, which may damage the buttons, knobs, or interfaces on the instrument panel. |
Proper ventilation | Poor ventilation will cause the device temperature to rise, thus causing damage to this device. Please keep proper ventilation during use, and regularly check the vents and fans. |
Keep clean and dry | Please take action to avoid dust or moisture in the air affecting the performance of this device. Please keep the product surface clean and dry. |
Note | |
Calibration | The recommended calibration period is one year. Calibration should only be carried out by qualified personnel. |
Environmental Requirements
- This instrument is suitable for the following environment.
- Indoor use
- Pollution degree 2
- In operating: altitude lower than 3000 meters; in non-operating: altitude lower than 15000 meters
- Unless otherwise specified, the operating temperature is 0 to +40℃; the storage temperature is -20 to﹢70℃
- In operating, humidity temperature below to +35℃, ≤90% relative humidity;
- In non-operating, humidity temperature +35℃to +40℃, ≤60% relative humidity
- There are ventilation openings on the rear panel and side panel of the instrument. So please keep the air flowing through the vents of the instrument housing.
- To prevent excessive dust from blocking the vents, please clean the instrument housing regularly.
- The housing is not waterproof, please disconnect the power supply first and then wipe the housing with a dry cloth or a slightly moistened soft cloth.
Connecting Power Supply
- The specification of input AC power.
Voltage Range | Frequency | Maximum Power |
100-240 VAC (fluctuant: ±10%) | 50/60 Hz | 75 W |
100-120 VAC (fluctuant: ±10%) | 400 Hz |
- Please use the attached power cable to connect to the power port.
Connecting to service cable
- This instrument is a Class I safety product. The supplied power lead has good performance in terms of case ground.
- This spectrum analyzer is equipped with a three-prong power cable that meets international safety standards.
- It provides good case grounding performance for the specification of your country or region.
- Please install the AC power cable as follows.
- Ensure the power cable is in good condition.
- Leave enough space for connecting the power cord.
- Plug the attached three-prong power cable into a well-grounded power socket.
Electrostatic Protection
- Electrostatic discharge may cause damage to components. Components can be damaged invisibly by electrostatic discharge during transportation, storage, and use.
- The following measures can reduce the damage of electrostatic discharge.
- Testing in the anti-static area as far as possible.
- Before connecting the power cable to the instrument, the inner and outer conductors of the instrument should be briefly grounded to discharge static electricity.
- Ensure all the instruments are properly grounded to prevent the accumulation of static.
Introduction of UPO1000
UPO1000 series digital phosphor oscilloscope includes three models.
Model | Analog Bandwidth | Analog Channel | Sampling Rate |
UPO1204 | 200 MHz | 4 | 2 GSa/s |
UPO1104 | 100 MHz | 4 | 2 GSa/s |
UPO1054 | 50 MHz | 4 | 2 GSa/s |
- UPO1000 series digital phosphor oscilloscope adopts UNI-T 3D technique Ultra Phosphor 2.0 with a new appearance upgrade and the function of deep storage, high waveform capture rate, real-time waveform recording, and playback,k and 256-level grayscale display.
- The series is equipped with three levels of bandwidth of 50 MHz/100 MHz/200 MHz, and a real-time sampling rate of up to 2 GSa/s.
- The whole series is equipped with 4 channels, the maximum storage depth is 56Mpts, up to 500,000wfms/s in Fast Acquire mode.
- Hardware real-time waveform uninterrupted recording and waveform analysis up to 120,000 waveform frames; support DVM module, rich trigger, and bus decoding functions, and full memory hardware real-time decoding.
- It is widely used in many fields, including communication, semiconductor, computer, IC design, instrumentation, industrial electronics, consumer electronics, automotive electronics, field maintenance, and R&D/education.
Getting Started Guide
- This chapter introduces using the oscilloscope for the first time, the front and rear panels, the user interface, as well as the built-in help system.
General Inspection
- It is recommended to inspect the instrument by following the steps below before using the UPO1000 series for the first time.
- Check for Damages caused by Transport
- If the packaging carton or the foam plastic cushions are severely damaged, please contact the UNI-T distributor of this product immediately.
- Check Attachment
- Please check the appendix for the list of accessories. If any of the accessories are missing or damaged, please contact UNI-T or local distributors of this product.
- Machine Inspection
- If the instrument appears to be damaged, not working properly, or has failed the functionality test, please contact UNI-T or local distributors of this product.
- If the equipment is damaged due to shipping, please keep the packaging and notify both the transportation department and UNI-T distributors, UNI-T will arrange maintenance or replacement.
- Check for Damages caused by Transport
Before Use
- To perform a quick verification of the instrument’s normal operations, please follow the steps below.
- Connecting to the Power Supply
- AC power specification of UPO1000 series digital storage oscilloscope refers to the Connecting Power Supply section. Use the assembled power line or other power line that meets the local country standards to connect the oscilloscope.
- The power soft indicator
in the left bottom on the front panel is extinguished and this soft switch key has no effect when the power switch on the rear panel is not opened.
- The power soft indicator
in the left bottom of the front panel is illuminated with red and then press the soft switch key to enable the oscilloscope.
- Boot Check
- Press the soft power key
and the indicator should change from red to green. The oscilloscope will show a boot animation, and then enter the normal interface.
- Press the soft power key
- Connecting Probe
- Use the BNC of the port to connect to the BNC of CH1 of the oscilloscope.
- Connecting the probe to the “probe compensation signal connection clip” and connecting the ground alligator clip to the “ground terminal” under the “probe compensation signal connection clip”.
- The output of the probe compensation signal connection clip is the amplitude about 3Vpp and the frequency defaults to 1 kHz.
- Function Check
- Press the AUTO key, and a 3 Vpp, 1 kHz square wave should appear on the screen. Repeat step 3 to check all channels.
- Probe Compensation
- When the probe is connected to any input channel for the first time, this step might be adjusted to match the probe and the input channel.
- Probes that are not compensated may lead to measurement errors or mistakes. Please follow the following steps.
- Set the attenuation coefficient in the probe menu to 10x and the switch of the probe to 10x, and connect the probe of the oscilloscope to CH1. If use the probe’s hook head, make sure it stably touches the probe.
- Connecting the probe to the “probe compensation signal connection clip” and connecting the ground alligator clip to the “ground terminal” under the “probe compensation signal connection clip”. Open CH1 and press the AUTO key.
- View the displayed waveform, as shown in Figure 4-2.
- If the displayed waveform looks like the above “Insufficient Compensation” or “Excessive Compensation”, use a non-metallic screwdriver to adjust the probe’s variable capacitance until the display matches the “Correct Compensation” waveform.
- Warning: To avoid electric shock when using the probe to measure high voltage, please ensure that the probe insulation is in good condition and avoid physical contact with any metallic part of the probe.
- Connecting to the Power Supply
Front Panel
Table 1 Function Key of Front Panel
No, | Function Key | No, | Function Key |
1 | Screen display area | 9 | Horizontal control area (HORIZONTAL) |
2 | Multipurpose rotary knob | 10 | Analog channel input port |
3 | Navigation function area | 11 | Vertical control area (VERTICAL) |
4 | Functional menu key | 12 | Menu control soft key |
5 | Run/Stop control key | 13 | Probe compensation signal connection clip and ground terminal |
6 | Single trigger control key | 14 | USB HOST port |
7 | Auto setting control key | 15 | Power switch soft key |
8 | Trigger control area (TRIGGER) |
Rear Panel
Table 1 Function Key of Rear Panel
No, | Function Key | No, | Function Key |
1 | EXT Trig | 5 | Power switch |
2 | AUX Out (output port) and arbitrary waveform signal output | 6 | AC Power input socket refers to the Connecting Power Supply |
3 | LAN interface | 7 | Safety lock |
4 | USB Device interface |
User Interface
Table 3 Icon of User Interface
No. | Description | No. | Description |
1 | Trigger status | 9 | Next page /System time/USB icon/LAN icon |
2 | Horizontal time base | 10 | CH4 state label |
3 | Horizontal offset | 11 | CH3 state label |
4 | Waveform indicator | 12 | CH2 state label |
5 | Trigger position | 13 | CH1 state label |
6 | Sampling rate and Storage depth | 14 | Analog channel label and waveform |
7 | Trigger information | 15 | Time base scale, volts/div scale popup |
8 | Operation menu |
- Press any soft key to activate the corresponding menu, the following symbol may display in the menu.
represents the use of the multipurpose rotary knob to select the parameter and adjust the parameter value.
represents the current menu has several options.
represents the current menu has a next menu.
represents the use numerical keyboard to input the parameter.
represents the current page can be page up and page down.
represents the use of the multipurpose rotary knob or press
in the Navigation bar to open the numerical keyboard and adjust the parameter value.
Remote Control
- UPO1000 series digital phosphor oscilloscope supports communication with a computer through a USB interface and LAN interface, to realize remote control.
- Remote control is based on SCPI (Standard Commands for Programmable Instruments).
- UPO1000 series digital phosphor oscilloscope supports three methods for remote control.
- User-defined programming
- Users can program control the instrument by SCPI. The details can be to in the UPO Series Programming Manual.
- PC software (instrument manager)
- Users can send the command via PC software to remote control the instrument. It is recommended to use the UNI-T PC software instrument manager.
- You can log in to UNI-T’s official website (https://www.uni-trend.com) to download the software. Operation Steps
- Setup the communication between the instrument and the computer
- Running the instrument manager and searching instrument source
- Open the remote command control panel to send a command. This instrument supports communication with the computer via USB, LAN, and RS232 interface, to realize remote control. The remote control is based on SCPI to realize.
- Web Control
- Open the Web via IP, use the user name and password to log in, and remote control the instrument. It supports remote control of the instrument by using a local network or outer network.
- User-defined programming
Troubleshooting
- When press the button, the oscilloscope is a black screen.
- a. Check whether the power is correctly connected and whether the power supply is normal or not.
- b. Check whether the power switch is really on, press the front panel power key, and confirm the green light and a relay sound are present.
- c. If there is a relay sound, it indicates that the oscilloscope starts normally. Try the following operations: press the DEFAULT key, then press F1, if the device returns to normal, it means the backlight brightness is too low.
- d. After completing the above steps, restart the oscilloscope.
- e. If you still cannot use this product normally, please contact UNI-T.
- After signal acquisition, the waveform of the signal does not appear in the picture.
- a. Check whether the two ends of the BNC line are connected properly.
- b. Check whether the output channel of the signal source is opened.
- c. Check whether the input channel of the oscilloscope is opened.
- d. Check whether the signal in the signal source has a DC offset.
- e. Plug out the input signal, and check whether the baseline is in the center of the screen (if the baseline is not in the center of the screen, it should be self-calibration.)
- f. If you still cannot use this product normally, please contact UNI-T.
- The measured voltage amplitude value is 10 times larger or 10 times smaller than the actual value: Check whether the channel probe attenuation coefficient settings are consistent with the used probe attenuation rate.
- There is a waveform display but not stable.
- a. Check the trigger settings in the trigger menu whether is consistent with the actual signal input channel.
- b. Check the trigger type: general signals should use the “Edge” trigger. Only when the proper trigger type is used, the waveform can be displayed stably.
- c. Try to change trigger coupling to HF rejection or LF rejection to filter out the high-frequency or low-frequency noise that interferes with the trigger.
- No waveform display after pressing the RUN/STOP key.
- a. Check whether the trigger mode in the trigger menu is “Normal” or “Single” and whether the trigger level exceeds the waveform range.
- b. If it exceeds, set the trigger level to the middle or set the mode to “Auto”.
- c. The above settings can be completed automatically by pressing the AUTO key.
- Waveform refresh is very slow.
- a. Check whether the acquisition method is average and the average times are large.
- b. Check whether the storage depth is the maximum.
- c. Check whether the trigger hold-off time is greater.
- d. Check whether the trigger is normal and the current time base is slow.
- e. All the above reasons will lead to a slow refresh of the waveform. It is recommended to restore the factory settings, and the waveform can be refreshed normally.
Appendix Contact Us
- If the use of this product has caused any inconvenience, if you are in mainland China you can contact UNI-T company directly.
- Service support: 8 am to 5.30 pm (UTC+8), Monday to Friday or via email. Our email address is infosh@uni-trend.com.cn
- For product support outside mainland China, please contact your local UNI-T distributor or sales center.
- Many UNI-T products have the option of extending the warranty and calibration period, please contact your local UNI-T dealer or sales center.
- Test Equipment Depot 8005178431
- TestEquipmentDepot.com
Copyright
- Copyright © Uni-Trend Technology (China) Co., Ltd. All rights reserved.
Trademark
- UNI-T is the registered trademark of Uni-Trend Technology (China) Co., Ltd.
File Version
- 20230822-V1.00.0018
Statement
- UNI-T products are protected by patent rights in China and foreign countries, including issued and pending patents.
- UNI-T reserves the rights to any product specification and pricing changes.
- UNI-T reserves all rights. Licensed software products are properties of Uni-Trend and its subsidiaries or suppliers, which are protected by national copyright laws and international treaty provisions.
- Information in this manual supersedes all previously published versions.
- Technical data are subject to change without prior notice.
Documents / Resources
![]() |
UNI-T UPO1102 Digital Phosphor Oscilloscope [pdf] User Guide UPO1102, UPO1102 Digital Phosphor Oscilloscope, Digital Phosphor Oscilloscope, Phosphor Oscilloscope, Oscilloscope |