UNI-T LM320D Angle Meter User Manual
UNI-T LM320D Angle Meter

PREFACE

Thank you for purchasing the new Angle Meter. In order to use this product safely and correctly, please read this manual thoroughly.
After reading this manual, it is recommended to keep the manual at an easily accessible place, preferably close to the device, for future reference.

LIMITED WARRANTY AND LIABILITY

Uni-Trend guarantees that the product is free from any defect in material and workmanship within one year from the purchase date. This warranty does not apply to damages caused by accident, negligence, misuse, modification, contamination and improper handling. The dealer shall not be entitled to give any other warranty on behalf of Uni-Trend. If you need warranty service within the warranty period, please contact authorized service center or send the product back with problem description .This warranty is the only compensation you can obtain. Uni-Trend will not be responsible for any special ,indirect, incidental or subsequent damage or loss caused by any reason or speculation. As some areas or countries do not allow imitations on implied warranties and incidental or subsequent damage, the above limitation of liability and stipulation may not apply to you.

Product Structure

Product Structure

  1. Laser ON/OFF Button(only LM320E, LM320F)
  2. -/+ Display Icon
  3. Angle Direction Icon
  4. Absolute/Relative Value Switch
  5. ( in / f * t, mm / m . %,°)Unit Switch
  6. Angle Display
  7. Absolute/ Relative Value Display
  8. Unit Switch/Sound ON/OFF
  9. Battery Display
  10. Mute Icon
  11. Data-Hold Display
  12. POWER/Data Lock Button
  13. Laser Emission Hole (only LM320E, LM320F)
  14. Type-C Charging Port

Operations:

Power On: In power-off state, long press Buttons button to power on.
Power Off: In power-on state, long press Buttons button to power off.

Laser ON/OFF (LM320E)
In power-on state, short press Buttons button to make all lasers on, and short press Buttons side. Short press Buttons button again to make the laser off on the right button again, the laser on the left side is off, and then short press Buttons button again to make all lasers off.

Laser ON/OFF (LM320F)
In power-on state, short press Buttons button to make all lasers on, and short press Buttons button again to make the laser off on the top side. Short press Buttons button again, the laser on the left side is off, and then short press Buttons button again to make the laser off on the right side; Short press Buttons button again to make all lasers off.
Operations

Angle Measurement
In power- on state, place the device on the inclined plane, the show value on the screen is the angle value between the inclined plane and the horizontal plane.
Operations

REF (Relative Value Mode):
In the measurement mode, short press Buttons button to enter the Relative Value mode (Set the current value to 0), and short press it again to exit the mode.
Angle Measurement
Angle Measurement
Angle Measurement

Calibration Mode

Place the device on the absolute horizon, continuously long press Buttons button for three times to enter the self-calibration mode (see figure 1); CALO flashes on the screen, short press Buttons button to confirm to enter the auto zero calibration (see figure 2).
Rotate the device 90 degrees, press Buttons flashes on the screen; short press Buttons button and CAL1 button to confirm to enter the auto zero calibration (see figure 3). Rotate the device 90 degrees, press Buttons short press button Buttons and CAL2 flashes on the screen; button to confirm to enter the auto zero calibration (see figure 4). Rotate the device 90 degrees, press and CAL3 flashes on the screen; short press Buttons button button to confirm to enter the auto zero calibration (see figure 5). The the calibration, and recover the use of is after power-on.

Figure 1
Calibration Mode

Figure 2
Calibration Mode

Figure 3
Calibration Mode

Figure 4
Calibration Mode

Figure 5
Calibration Mode

Data Lock
In the measurement mode, short press button to lock the current measured data; short press again to unlock the data.
Data Lock

Unit Switch & Sound ON/OFF

For LM320E/LM320F, long press Buttons button to switch the unit (in unit by default), mm/m,%, or in/ft. In in/ft unit display, when ‘-‘icon shows on the screen, the range of measured value is within ‘measured value – 1/8 ~ measured value’; when+’icon shows, the range of measured value is within ‘measured value ~ measured value 1 / (8’) For example, 11.7/8 display means 11 and 7/8; 9 – 3/8 display means 9 and 3/8.
For LM320D, short press UNIT button to switch the unit. For LM320E/LM320F, short press Buttons button to make the sound button to make indication on/off; For LM320D, short press Buttons the sound indication on/off.
Unit Switch

Charge
When low battery icon Battery Icon shows on the screen, please charge the device with charging cable in the accessories. In the power-off state, battery is fully charged when its icon stops flashing and not showed on the screen any more.
Charge

Technical Parameters

  Models LM320D LM320E LM320F
Measurement Range 4*90° 4*90° 4*90°
Resolution ±0.05° ±0.05° ±0.05°
Angle Accuracy ±0.2° ±0.2° ±0.2°
Repeatability ±0.2° ±0.2° ±0.2°
Unit Angle; Percentage; Metric system of mm/m; British system of in/ft.
Laser Lines N 2 lines 13 lines
Laser Accuracy N ±3mm/5m
Magnetic Base Two-sided magnetic Two-sided magnetic I Four Fished magnetic
Relative/Absolute Angle Measurement
Angle Hold
Screen Rotation
Power Off No operations in 5 minutes.
Materials Al-alloy frame +ABS
Power Supply 3.7V 1000mAh lithium battery
Working Temperature 0°C – + 50 °C
Laser Class N Class 2
Laser Life N 630-670n m, <1mW
Battery Life 14 h 8h 1             6h
Size 83.5* 70 * 35.5mm
Package Angle Meter*1, Type-C Cable*1, Gift Box*1, User Manual*1

Cautions:

  1. Do not use organic solvents to wash the percision equipment. Take it far away from water and corrosives.
  2. Do not damage the surface of device; use soft cloth towipe the dust for its accuracy.
  3. For power saving, the device will be auto power off if no operations in 5 minutes.

LASER RADIATION
DO NOT STARE INTO BEAM CLASS 2 CONSUMER LASER PRODUCT Compliance with IEC/EN 60825-1, EN 50689.
Cautions
Cautions

The manual is subject to change without prior notice!

Due to different batches, the materials and details of actual products may be slightly different from the graphic information, please refer to the actual product received. Experimental data provided in the page is from internal laboratory of UNI-T, but it should not be a reference for customer to place orders. Any questions, please contact the customer service, thanks

UNI-TREND TECHNOLOGY (CHINA) CO., LTD.
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone, Dongguan City, Guangdong Province, China Tel: (86-769) 8572 3888
www.uni-trend.com
P/N:110401113327X
UNI-T Logo

Documents / Resources

UNI-T LM320D Angle Meter [pdf] User Manual
LM320D, LM320E, LM320F, LM320D Angle Meter, LM320D, Angle Meter, Meter
UNI-T LM320D Angle Meter [pdf] User Manual
LM320D, LM320E, LM320F, LM320D Angle Meter, LM320D, Angle Meter

References

Leave a comment

Your email address will not be published. Required fields are marked *